Bio-Medical Factors and External Hazards in Space Station Design

The design of space-station configurations is influenced by many factors, Probably the most demanding and critical are the biomedical and external hazards requirements imposed to provide the proper environment and supporting facilities for the crew and the adequate protective measures necessary to provide a configuration in which the crew can live and work efficiently in relative comfort and safety. The major biomedical factors, such as physiology, psychology, nutrition, personal hygiene, waste management, and recreation, all impose their own peculiar requirements. The commonality and integration of these requirements demand the utmost ingenuity and inventiveness be exercised in order to achieve effective configuration compliance. The relationship of biomedical factors for the internal space-station environment will be explored with respect to internal atmospheric constituency, atmospheric pressure levels, oxygen positive pressure, temperature, humidity, CO2 concentration, and atmospheric contamination. The range of these various parameters and the recommended levels for design use will be analyzed. Requirements and criteria for specific problem areas such as zero and artificial gravity and crew private quarters will be reviewed and the impact on the design of representative solutions will be presented. In the areas of external hazards, the impact of factors such as meteoroids, radiation, vacuum, temperature extremes, and cycling on station design will be evaluated. Considerations with respect to operational effectiveness and crew safety will be discussed. The impact of such factors on spacecraft design to achieve acceptable launch and reentry g levels, crew rotation intervals, etc., will be reviewed. Examples of configurations, subsystems, and internal a arrangement and installations to comply with such biomedical factor requirements will ber presented. The effects of solutions to certain biomedical factors on configuration weight, operational convenience, and program costs will be compared.

Olling, Edward H.↗

Design and Testing of a 2-Hour Oxygen Prebreathe Protocol for Space Walks from the International Space Station

To develop and test a 2-hour prebreathe protocol for performing extravehicular activities (EVAs) from the International Space Station (ISS). Combinations of adynamia (non-walking), prebreathe exercise, and space suit donning options (10.2 vs. 14.7 psi) were evaluated, against timeline and consumable contraints to develop an operational 2- hour prebreathe protocol. Prospective accept/reject criteria were defined for decompression sickness (DCS) and venous gas emboli (VGE) from analysis of historical DCS data, combined with risk management of DCS under ISS mission circumstances. Maximum operational DCS levels were defined based on protecting for EVA capability with two crew-members at 95% confidence, throughout ISS lifetime (within the constraints of NASA DCS disposition policy JPG 1800.3). The accept/reject limits were adjusted for greater safety based on analysis of related medical factors. Monte-Carlo simulation was performed to design a closed sequential, multi-center human trial. Protocols were tested with 4 different prebreathe exercises (Phases I-IV), prior to exposure to 4.3 psi for 4 hrs. Subject selection, Doppler monitoring for VGE, test termination criteria, and DCS definitions were standardized. Phase I: upper and lower body exercises using dual-cycle ergometry (75% VO2 max for 10 min). Phase II: ergometry plus 24 min of light exercise (simulating space-suit preparations). Phase III: same 24 min of light exercise but no ergometry, and Phase IV: 56 min of light exercise without ergometry. A prebreathe procedure was accepted if, at 95% confidence, the incidence of DCS was less than 15% (with no Type II DCS), and Grade IV VGE was less than 20%.

Gernhardt, Michael L.↗

Inductively-Coupled RF Powered O2 Plasma as a Sterilization Source

Low-temperature or cold plasmas have been shown to be effective for the sterilization of sensitive medical devices and electronic equipment. Low-temperature plasma sterilization procedures possess certain advantages over other protocols such as ethylene oxide, gamma radiation, and heat due to the use of inexpensive reagents, the insignificant environmental impacts and the low energy requirements. In addition, plasmas may also be more efficacious in the removal of robust microorganisms due to their higher chemical reactivity. Together, these attributes render cold plasma sterilization as ideal for the surface decontamination requirements for NASA Planetary Protection. Hence, the work described in this study involves the construction, characterization, and application of an inductively-coupled, RF powered oxygen (O2) plasma.

Sharma, S. P.↗

Unique cell culture systems for ground based research

The horizontally rotating fluid-filled, membrane oxygenated bioreactors developed at NASA Johnson for spacecraft applications provide a powerful tool for ground-based research. Three-dimensional aggregates formed by cells cultured on microcarrier beads are useful for study of cell-cell interactions and tissue development. By comparing electron micrographs of plant seedlings germinated during Shuttle flight 61-C and in an earth-based rotating bioreactor it is shown that some effects of microgravity are mimicked. Bioreactors used in the UAH Bioreactor Laboratory will make it possible to determine some of the effects of altered gravity at the cellular level. Bioreactors can be valuable for performing critical, preliminary-to-spaceflight experiments as well as medical investigations such as in vitro tumor cell growth and chemotherapeutic drug response; the enrichment of stem cells from bone marrow; and the effect of altered gravity on bone and muscle cell growth and function and immune response depression.

Lewis, Marian L.↗

Multisensor Instrument for Real-Time Biological Monitoring

The figure schematically depicts an instrumentation system, called a fiber optic-based integration system (FOBIS), that is undergoing development to enable real-time monitoring of fluid cell cultures, bioprocess flows, and the like. The FOBIS design combines a micro flow cytometer (MFC), a microphotometer (MP), and a fluorescence-spectrum- or binding-force-measuring micro-sensor (MS) in a single instrument that is capable of measuring multiple biological parameters simultaneously or sequentially. The fiber-optic-based integration system is so named because the MFC, the MP, and the MS are integrated into a single optical system that is coupled to light sources and photometric equipment via optical fibers. The optical coupling components also include a wavelength-division multiplexer and diffractive optical elements. The FOBIS includes a laserdiode- and fiber-optic-based optical trapping subsystem (optical tweezers ) with microphotometric and micro-sensing capabilities for noninvasive confinement and optical measurement of relevant parameters of a single cell or other particle. Some of the measurement techniques implemented together by the FOBIS have long been used separately to obtain basic understanding of the optical properties of individual cells and other organisms, the optical properties of populations of organisms, and the interrelationships among these properties, physiology of the organisms, and physical processes that govern the media that surround the organisms. For example, flow cytometry yields information on numerical concentrations, cross-sectional areas, and types of cells or other particles. Micro-sensing can be used to measure pH and concentrations of oxygen, carbon dioxide, glucose, metabolites, calcium, and antigens in a cell-culture fluid, thereby providing feedback that can be helpful in improving control over a bioprocess. Microphotometry (including measurements of scattering and fluorescence) can yield further information about optically trapped individual particles. In addition to the multifunctionality not previously available in a single biological monitoring system, the FOBIS offers advantages of low mass, sensitivity, accuracy, portability, low cost, compactness (the overall dimensions of the fully developed FOBIS sensor head are expected to be less than 1 by 1 by 2 cm), and immunity to electromagnetic interference at suboptical frequencies. FOBIS could be useful in a variety of laboratory and field settings in such diverse endeavors as medical, veterinary, and general biological research; medical and veterinary diagnosis monitoring of industrial bioprocesses; and analysis of biological contaminants in air, water, and food.

Zhang, Sean (Zhanxiang)↗

Monitoring Astronaut Health at the Nanoscale Cellular Level Through the Eye

A user friendly goggles-like head-mounted device equipped with a suite of instruments for several non-invasive and quantitative medical evaluation of the eye, skin, and brain is desired for monitoring the health of astronauts during space travel and exploration of neighboring and distant planets. Real-time non-invasive evaluation of the different structures within the above organs can provide indices of the health of not just these organs, but the entire body. The techniques such as dynamic light scattering (for the early detection of uveitis, cholesterol levels, cataract, changes in the vitreous and possibly Alzheimer's disease), corneal autofluorescence (to assess extracellular matrix biology e.g., in diabetes), optical activity measurements (of anterior ocular fluid to evaluate blood-glucose levels), laser Doppler velocimetry (to assess retinal, optic nerve, and choroidal blood flow), reflectometry/oximetry (for assessing ocular and central nervous system oxygen metabolism), optical coherence tomography (to determine retinal tissue microstructure) and possibly scanning laser technology (for intraocular tissue imaging and scanning) will he integrated into this compact device. Skin sensors will also be mounted on the portion of the device in contact with the periocular region. This will enable monitoring of body temperature, EEG, and electrolyte status. This device will monitor astronaut health during long-duration space travel by detecting aberrations from pre-established "nonns", enabling prompt diagnosis and possibly the initiation of early preventative/curative therapy. The non-invasive nature of the device technologies permits frequent repetition of tests, enabling real-time complete crew health monitoring. This device may ultimately be useful in tele-medicine to bring modern healthcare to under-served areas on Earth as well as in so-called "advanced" care settings (e.g. diabetes in the USA).

Ansari, Rafat R.↗

Volume Ice Radiolysis in the Outer Solar System

The primary energy flux of charged particle components of the heliospheric and magnetospheric environments of the solar system is primarily carried by highly penetrating energetic particles. Although laboratory experiments on production of organics and oxidants typically only address effects on very thin surface layers, energy deposition occurs on surfaces of icy bodies of the outer solar system to meters in depth. Time scales for significant radiolytic deposition vary from thousands of years at millimeter depths on Europa to billions of years in the meters-deep regolith of Kuiper Belt Objects. Radioisotope decay (e.g., K-40) also contributes to volume radiolysis as the only energy source at much greater depths. Radiolytic oxygen is a potential resource for life within Europa and a partial source of oxygen for Saturn's magnetosphere and Titan's upper atmosphere. Interactions of very high energy cosmic rays with ices at Titan's surface may provide one of the few sources of oxidants in that highly reducing environment. The red colors of low-inclination classical Kuiper Belt Objects at 40-50 AU, and Centaur objects originating from this same population, may arise from volume radiolysis of deep ice layers below more refractory radiation crusts eroded away by surface sputtering and micrometeoroid impacts. A variety of techniques are potentially available to measure volume radiolysis products and have been proposed for study as part of the new Space Physics of Life initiative at NASA Goddard Space Flight Center. The technique of Electron Paramagnetic Resonance (EPR) has been used in medical studies to measure oxidant production in irradiated human tissue for cancer treatment. Other potential techniques include optical absorption spectroscopy and standard wet chemical analysis. These and other potential techniques are briefly reviewed for applicability to problems in solar system ice radiolysis and astrobiology.

Cooper, John F.↗

The physiological cost of wearing the propellant handler's ensemble at the Kennedy Space Center

The potential for exposure to toxins used in the propulsion systems of spacecraft dictates the use of a whole body protective suit, the Propellant Handler's Ensemble (PHE) during preflight preparation and launching. The weight, structure, and operating parameters of the PHE may be expected to have a significant impact upon the metabolic, cardiovascular, and thermal responses of the user, especially during ambient temperature extremes and high workload situations. Four male subjects participated in tests in -7, 23, and 43 C (20, 74, and 110 F) environments in two versions of the PHE, the autonomous backpack (BP) and the hoseline (HL) supplied configuration. Measurements included heart rate (HR) rectal temperature, four skin temperatures, oxygen (O2), and carbon dioxide (CO2) in the helmet area, interior suit temperature, and suit pressure. Exercise metabolism was estimated from HR, PHE weight, and treadmill speed and grade. The HR responses between each PHE configuration were not statistically different. As a percentage of HR maximum, the mean values were 79 percent (COLD), 84 percent (LAB), and 90 percent (HOT). Helmet O2 and CO2 levels were correlated with percent HR max (P less than 0.001). Rectal temperatures were similar for each PHE configuration, except in the HOT exposure where the BP version exceeded the HL configuration (P less than 0.05). In nearly every instance the HR was driven to moderately high levels, the supplied respiratory gases were not optimum, and thermal adversity was a primary stressor. Our findings suggest that medical and physical fitness standards, along with operational restrictions, should be imposed upon PHE users to avoid situations that could adversely affect the worker.

Schonfeld, Brian R.↗

Suited Ground Vacuum Chamber Testing Decompression Sickness Tiger Team Report

Suited vacuum chamber testing is critical to flight crew training, sustaining engineering, and development engineering. Most suited vacuum chamber testing at NASA’s Johnson Space Center (JSC) involves crewmembers or human test subjects working at a hypobaric pressure of 4.3 psia, which requires that an oxygen prebreathe be performed prior to decompression to reduce the risk of decompression sickness (DCS). Since 1986, NASA’s policy has been to require a 4-hour resting prebreathe for hypobaric chamber exposures of 4.2 psia lasting greater than 30 minutes. There have been no reports of Type II (i.e., serious, potentially life-threatening) DCS at NASA while using this prebreathe protocol. Several chamber runs, believed to be approximately 5% of all runs, are believed to have been terminated due to Type I DCS symptoms that were performance impairing; however, detailed records of DCS symptoms during suited vacuum chamber runs are not available. The adequacy of the 4-hour prebreathe protocol, as well as the processes by which prebreathe protocols and policies are established, became the subject of significant discussion in April 2018 when medical planning was initiated for chamber runs that were scheduled to occur later in 2018 that would last 8 hours or more with high metabolic rates.

Abercromby, Andrew F. J.↗

Measurement of Charged Particle Interactions in Spacecraft and Planetary Habitat Shielding Materials

Accurate models of health risks to astronauts on long-duration missions outside the geomagnetosphere will require a full understanding of the radiation environment inside a spacecraft or planetary habitat. This in turn requires detailed knowledge of the flux of incident particles and their propagation through matter, including the nuclear interactions of heavy ions that are a part of the Galactic Cosmic Radiation (GCR). The most important ions are likely to be iron, silicon, oxygen, and carbon. Transport of heavy ions through complex shielding materials including self-shielding of tissue modifies the radiation field at points of interest (e.g., at the blood-forming organs). The incident flux is changed by two types of interactions: (1) ionization energy loss, which results in reduced particle velocity and higher LET (Linear Energy Transfer); and (2) nuclear interactions that fragment the incident nuclei into less massive ions. Ionization energy loss is well understood, nuclear interactions less so. Thus studies of nuclear fragmentation at GCR-like energies are needed to fill the large gaps that currently exist in the database. These can be done at only a few accelerator facilities where appropriate beams are available. Here we report results from experiments performed at the Brookhaven National Laboratory s Alternating Gradient Synchrotron (AGS) and the Heavy Ion Medical Accelerator in Chiba, Japan (HIMAC). Recent efforts have focused on extracting charge-changing and fragment production cross sections from silicon beams at 400, 600, and 1200 MeV/nucleon. Some energy dependence is observed in the fragment production cross sections, and as in other data sets the production of fragments with even charge numbers is enhanced relative to those with odd charge numbers. These data are compared to the NASA-LaRC model NUCFRG2. The charge-changing cross section data are compared to recent calculations using an improved model due to Tripathi, which accurately predicts the observed (slight) energy dependence. An additional set of data will be presented from an analysis of shielding material performance in the 1 GeV/nucleon iron beam at the AGS. A wide variety of candidate materials for spacecraft construction, as well as elemental targets, have been placed in this beam and their effects on transmitted dose and dose equivalent measured. The results support a prediction by J. Wilson et al. that hydrogen-loaded materials give the greatest dose reduction per unit mass.

Zeitlin, Cary J.↗

Design of a 2-Hour Prebreathe Protocol for Space Walks (EVAs) from the International Space Station (ISS)

The majority of extravehicular activities (EVAs) performed from the shuttle use a 10.2 psi staged decompression. The International Space Station (ISS) will operate at 14.7 psi, requiring crews to "campout" in the airlock at 10.2 psi. The constraints associated with campout (crew isolation, oxygen usage, and waste management), provided the rationale to develop a 2-hour prebreathe protocol from 14.7 psi. Previous studies on the affect of microgravity and exercise during prebreathe suggested the feasibility of this approach. Various combinations of adynamia (nonwalking subjects), prebreathe exercise doses, and space suit donning options (10.2 vs. 14.7 psi) were analyzed against timeline and consumable constraints. Prospective decompression sickness (DCS) and venous gas emboli (VGE) accept/reject criteria were defined from statistical analysis of historical DCS data, combined with risk management of DCS under ISS mission circumstances. Maximum operational DCS levels were defined based on protecting for EVA capability with two crew members at 95% confidence, throughout ISS lifetime (within the constraints of NASA DCS disposition policy JPG 1800.3). The accept / reject limits were adjusted for greater safety (including Grade IV VGE criteria) based on analysis of related medical factors. Monte-Carlo simulation was performed to design a closed sequential, multi-center laboratory trial, including the capability of rejecting the primary protocol and testing at least one alternate exercise dose, within the 2-hour prebreathe. The 2-hour protocol incorporates 0, breathing for 5 0 min at 14.7 psi, including 10 min dual cycle ergometry at 75%VO(2max). It requires an additional 30 minO2breathing during depress from 14.7 to 10.2 psi, followed by a 30-60 min suit donning break at 10.2 psi/26.5% O2. It concludes with a 40 min in-suit O2 prebreathe. The protocol would be accepted for operations, if the incidence of DCS was less than 15% and Grade IV VGE less than 20%, both at 95% confidence. The above protocol and accept/reject limits were implemented in a multi-center study.

Gernhardt, M. L.↗

NASA Tech Briefs, March 2006

Topics covered include: Medical Signal-Conditioning and Data-Interface System; Instruments for Reading Direct-Marked Data-Matrix Symbols; Processing EOS MLS Level-2 Data; Ground Processing of Data From the Mars Exploration Rovers; Estimating Total Electron Content Using 1,000+ GPS Receivers; NASA Solar Array Demonstrates Commercial Potential; Improved Control of Charging Voltage for Li-Ion Battery; Programmable Pulse-Position-Modulation Encoder; Wavelength-Agile External-Cavity Diode Laser for DWDM; Pattern-Recognition Processor Using Holographic Photopolymer; Submicrosecond Power-Switching Test Circuit; Three-Function Logic Gate Controlled by Analog Voltage; Integrated System for Autonomous Science; Montage Version 3.0; Utilizing AI in Temporal, Spatial, and Resource Scheduling; Satellite Image Mosaic Engine; Architecture for Control of the K9 Rover; HFGMC Enhancement of MAC/GMC; Automated Activation and Deactivation of a System Under Test; Cleaning Carbon Nanotubes by Use of Mild Oxygen Plasmas; Generating Aromatics From CO2 on Mars or Natural Gas on Earth; Attaching Thermocouples by Peening or Crimping; Heat Treatment of Friction-Stir-Welded 7050 Aluminum Plates; Generating Breathable Air Through Dissociation of N2O; High-Performance Scanning Acousto-Ultrasonic System; Correction for Thermal EMFs in Thermocouple Feedthroughs; Using Quasiparticle Poisoning To Detect Photons; Estimating Resolution Lengths of Hybrid Turbulence Models; Education and Training Module in Alertness Management; Cargo-Positioning System for Next-Generation Spacecraft; Micro-Imagers for Spaceborne Cell-Growth Experiments; Holographic Solar Photon Thrusters; Plasma-Based Detector of Outer-Space Dust Particles; and Generation of Data-Rate Profiles of Ka-Band Deep-Space Links.

Source record↗

Elastomeric Sensing of Pressure with Liquid Metal and Wireless Inductive Coupling

This project describes resistance-based soft sensors filled with liquid metal, which permit measurements of large strains (0 percent to 110 percent), associated with small forces of less than 30 Newtons. This work also demonstrates a methodology for wireless transfer of these strain measurements without connected electrodes. These sensors allow intermittent detection of pressure on soft membranes with low force. Adapting these sensors for passive wireless pressure sensing will eliminate the need for embedded batteries, and will allow the sensors to transmit pressure data through non-conductive materials including glass and acrylic. The absence of batteries allows us to embed these sensors into materials for long-term use because the sensors only use passive analog circuit elements. We found the oxidation of the liquid metal (eutectic gallium indium) plays a role in the repeatability of the soft sensors. We investigated how the oxidation layer affected the behavior of the sensor by encapsulating materials (silicone, fluorosilicone, and PVC) with varied permeabilities to oxygen. We measured the effects of mechanical loading on the oxidation layer and the effects of wireless inductive coupling on the oxidation layer. We concluded our research by investigating the effects of embedding self-resonant circuits into polydimethylsiloxane (PDMS). Efforts to design engineered systems with soft materials are a growing field with progress in soft robotics, epidermal electronics, and wearable electronics. In the field of soft robotics, PDMS-based grippers are capable of picking up delicate objects because their form-fitting properties allow them to conform to the shape of objects more easily than conventional robotic grippers. Epidermal devices also use PDMS as a substrate to hold electronic components such as radios, sensors, and power supply circuits. Additionally, PDMS-based soft sensors can monitor human motion with liquid metal embedded within micro-channels. Passive wireless sensors have applications in structural health monitoring and medical health monitoring. Doctors can take wireless blood pressure measurements inside arteries to monitor the progression of heart disease. Glaucoma patients can use this technology to monitor the pressure in their eyes to track the progression of the disease.

Dick, Jacob↗

Pulmonary decompression sickness at altitude: early symptoms and circulating gas emboli

INTRODUCTION: Pulmonary altitude decompression sickness (DCS) is a rare condition. 'Chokes' which are characterized by the triad of substernal pain, cough, and dyspnea, are considered to be associated with severe accumulation of gas bubbles in the pulmonary capillaries and may rapidly develop into a life-threatening medical emergency. This study was aimed at characterizing early symptomatology and the appearance of venous gas emboli (VGE). METHODS: Symptoms of simulated-altitude DCS and VGE (with echo-imaging ultrasound) were analyzed in 468 subjects who participated in 22 high altitude hypobaric chamber research protocols from 1983 to 2001 at Brooks Air Force Base, TX. RESULTS: Of 2525 subject-exposures to simulated altitude, 1030 (41%) had symptoms of DCS. Only 29 of those included DCS-related pulmonary symptoms. Of these, only 3 subjects had all three pulmonary symptoms of chokes; 9 subjects had two of the pulmonary symptoms; and 17 subjects had only one. Of the 29 subject-exposures with pulmonary symptoms, 27 had VGE and 21 had severe VGE. The mean onset times of VGE and symptoms in the 29 subject-exposures were 42 +/- 30 min and 109 +/- 61 min, respectively. In 15 subjects, the symptoms disappeared during recompression to ground level followed by 2 h of oxygen breathing. In the remaining 14 cases, the symptoms disappeared with immediate hyperbaric oxygen treatment. CONCLUSIONS: Pulmonary altitude DCS or chokes is confirmed to be a rare condition. Our data showed that when diagnosed early, recompression to ground level pressure and/or hyperbaric oxygen treatment was 100% successful in resolving the symptoms.

Non-NASA Center↗

An overview of the issues: physiological effects of bed rest and restricted physical activity

Reduction of exercise capacity with confinement to bed rest is well recognized. Underlying physiological mechanisms include dramatic reductions in maximal stroke volume, cardiac output, and oxygen uptake. However, bed rest by itself does not appear to contribute to cardiac dysfunction. Increased muscle fatigue is associated with reduced muscle blood flow, red cell volume, capillarization and oxidative enzymes. Loss of muscle mass and bone density may be reflected by reduced muscle strength and higher risk for injury to bones and joints. The resultant deconditioning caused by bed rest can be independent of the primary disease and physically debilitating in patients who attempt to reambulate to normal active living and working. A challenge to clinicians and health care specialists has been the identification of appropriate and effective methods to restore physical capacity of patients during or after restricted physical activity associated with prolonged bed rest. The examination of physiological responses to bed rest deconditioning and exercise training in healthy subjects has provided significant information to develop effective rehabilitation treatments. The successful application of acute exercise to enhance orthostatic stability, daily endurance exercise to maintain aerobic capacity, or specific resistance exercises to maintain musculoskeletal integrity rather than the use of surgical, pharmacological, and other medical treatments for clinical conditions has been enhanced by investigation and understanding of underlying mechanisms that distinguish physical deconditioning from the disease. This symposium presents an overview of cardiovascular and musculoskeletal deconditioning associated with reduced physical work capacity following prolonged bed rest and exercise training regimens that have proven successful in ameliorating or reversing these adverse effects.

NASA Program Space Physiology and Countermeasures↗

Partitioning of Inorganic Elements Consumed by Humans Between the Various Fractions of Human Wastes: A Review and Analysis of Existing Literature

The nutritional requirements of humans and astronauts are well defined and show consistency, but the same cannot be said of human wastes. Nutrients taken up by humans can be considered to fall into two major categories - organic and inorganic fractions. Carbon, hydrogen, oxygen, nitrogen and sulfur are elements that are associated with the organic fraction. These elements are taken up in large amounts by humans and when metabolized released in wastes often in gaseous forms or as water. On the other hand, a large number of the elements are simply exchanged and can be accounted for in the liquid and solid wastes of humans. These elements fall into three major categories - cationic macroelements (e.g. Ca, K, Na, Mg and Si), anionic macroelements (e.g P, S and Cl), 17 essential microelements, (e.g. Fe, Mn, Cr, Co, Cu, Zn, Se and Sr). When provided in the recommended concentrations to an adult human, these elements should not normally accumulate in humans, but will be excreted in the different human wastes. Knowledge of the partitioning of these elements between the different human waste fractions is fundamental to understanding (a) how these elements can be recovered for reuse in space habitats, and (b) to developing the processors for waste management. The current literature is exhaustive but sometimes also conflicting. We have used the existing knowledge of nutrition and waste from medical literature and NASA documentation to develop a consensus to typify and chemically characterize the various human wastes. The partitioning of these elements has been developed into a functional model.

Wignarajah, K.↗

Biosensors for EVA: Improved Instrumentation for Ground-based Studies

During lunar excursions in the EVA suit, real-time measurement of metabolic rate is required to manage consumables and guide activities to ensure safe return to the base. Metabolic rate, or oxygen consumption (VO2), is normally measured from pulmonary parameters but cannot be determined with standard techniques in the oxygen-rich environment of a spacesuit. Our group has developed novel near infrared spectroscopic (NIRS) methods to calculate muscle oxygen saturation (SmO 2), hematocrit, and pH, and we recently demonstrated that we can use our NIRS sensor to measure VO 2 on the leg during cycling. Our NSBRI project has 4 objectives: (1) increase the accuracy of the metabolic rate calculation through improved prediction of stroke volume; (2) investigate the relative contributions of calf and thigh oxygen consumption to metabolic rate calculation for walking and running; (3) demonstrate that the NIRS-based noninvasive metabolic rate methodology is sensitive enough to detect decrement in VO 2 in a space analog; and (4) improve instrumentation to allow testing within a spacesuit. Over the past year we have made progress on all four objectives, but the most significant progress was made in improving the instrumentation. The NIRS system currently in use at JSC is based on fiber optics technology. Optical fiber bundles are used to deliver light from a light source in the monitor to the patient, and light reflected back from the patient s muscle to the monitor for spectroscopic analysis. The fiber optic cables are large and fragile, and there is no way to get them in and out of the test spacesuit used for ground-based studies. With complimentary funding from the US Army, we undertook a complete redesign of the sensor and control electronics to build a novel system small enough to be used within the spacesuit and portable enough to be used by a combat medic. In the new system the filament lamp used in the fiber optic system was replaced with a novel broadband near infrared LED light source. The compact grating spectrometer was replaced with a chip-scale spectrometer. With this new design, the sensor is 4 in 2 in 0.5 in, weighs 60 g, and no fiber optic cables are needed. The sensor, which contains the light source and the spectrometer, is adhered directly to the skin with medical grade adhesive. The sensor can be powered via the USB port of the laptop computer that controls the sensor operation. Alternatively, for studies in the spacesuit, the sensor can be powered by a small battery pack and operated by an ultra-portable hand-held computer. Both the handheld computer and battery pack will easily fit within the PLSS of the test spacesuit. System automation was significantly improved, to add features suggested by our colleagues in the Cardiovascular Laboratory and the NASA JSC Exercise Physiology and Countermeasures Project. The functionality and portability of this system were demonstrated in our UMass laboratory.

Soller, B.↗

Status of the US Space Station ECLSS and internal TCS

The U.S. Space Station includes many elements and systems. Responsibility for these have been delegated to four NASA centers via a work packaging concept. Marshall Space Flight Center (MSFC) is responsible for work package one (WPOI) which includes the habitation, laboratory modules, the logistic carrier elements, as well as the environmental control and life support system (ECLSS), the internal thermal control system (ITCS), and the internal audio and video systems. Current status of the ECLSS and internal thermal are the subjects of this paper. The ECLSS is composed of six subsystem groups: the temperature humidity control, the atmosphere control and supply, the air revitalization, water reclamation and management, fecal waste management, and the fire detection and suppression subsystems. The internal TCS consists of all WP01 elements of passive and active thermal measures. The ECLSS and ITCS provide services for the permanently orbiting pressurized modules as well as the pressurized and unpressurized logistics carriers. The logistics carriers are used as ground-to-station ferries for both resupply and initial delivery of selected new equipment and later replacement items. Equipment, which cannot be subjected to the rigors of the space environment, will be carried in the pressurized logistic carrier; while an unpressurized carrier is used to resupply other commodities, such as external fluid consumables. The laboratory module houses the equipment for both payloads and subsystem maintenance and repair. The habitation module is dedicated to providing living and sleeping quarters including a galley, sleeping provisions, hygiene facilities, medical services as well as services for exercise and relaxation. The four nodes that join the two modules at their ends also house electronics as well as work stations and outside viewing cupolas. The airlocks, one providing an emergency hyperbaric chamber capability, are also attached. This assembly constitutes the U.S. provided portion of the initial station. Additional international modules and docking provisions for future attached pressurized payload as well as dual logistic module and growth capabilities are also provided. The primary heat rejection mechanism is achieved via a central set of radiators provided by another work package. The interface with the central TCS at the module heat exchangers defines the active control interface boundary of the ITCS with the central TCS. All internal cooling of the permanent orbital elements are provided via internal active fluid loops within the elements utilizing water as the transport media. Cabin and equipment cooling are provided by forced air flow and cold plate heat sinks. A special active cooling loop is provided in the laboratory module to accommodate experiments and other payloads. Coatings and insulation are used in conjunction with the active components to passively limit heat losses/gains. The most challenging ECLSS new technology issues relate to oxygen and water recovery. Closure of the oxygen loop requires the use of new regenerative CO 2 removal and concentration techniques, CO 2 reduction to convert the CO 2 to water with a waste by-product, and the electrolysis of water to produce breathing oxygen for water recovery. For water recovery three separate loops are currently planned. One loop provides potable water by utilizing a combination of recovered condensate and CO 2 reduction water. A second loop purifies hygiene water from waste from the showers, clothes washer, hygiene/hand wash stations and a dishwasher. The third loop provides hygiene water by the reclamation and purification of urine water. This paper outlines the basic services provided by the ECLSS and ITCS and describes the ECLSS functional distribution throughout the pressurized assembly.