Search NASA⌕ Search

SEARCH · Search NASA

Results for “Microchannels”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Flow boiling of R134a in a large surface area microchannel array for high-flux laser diode cooling

Packaging high average power laser diode arrays that generate heat at an area average flux in excess of 1 kW·cm -2 is a significant engineering challenge. While liquid microchannel coolers have demonstrated up to 11.9 kW·cm -2 , two-phase microchannel array coolers have not achieved 1 kW cm -2 due to critical heat flux and flow instabilities. In the current study, flow boiling heat transfer was characterized by a 1 &times; 10 mm heated zone centered over a 5 &times; 10 mm array of 125 very small channels (45 &times; 200 &mu;m) with R134a as the phase change fluid. The high aspect ratio channels (4.4:1) were manufactured using MEMS fabrication techniques, which yielded a large heat transfer surface area to volume ratio. A test facility was used to characterize the heat transfer performance of boiling R134a over a range of saturation temperatures (15&deg;C to 25&deg;C), mass fluxes (735-2230 kg·m -2 ·s -1 ), and heat duties (< 110.3 W). During the tests, the calculated outlet vapor quality exceeded 61%, and the base heat flux at the heater reached a maximum of 1.1 kW·cm -2 . The resulting average experimental flow boiling heat transfer coefficients are found to be as large a 13.4 kW·m -2 ·K -1 over the approximately 3 mm two-phase region, with an average uncertainty of ± 2.72%. A substantial amount of heat was spread downstream via the low thermal resistance silicon floor. Specifically, between 29.5% and 55.1% of the heat dissipated in the two-phase region was dissipated over the heater. Finally, the remaining heat dissipated in the two-phase region was dissipated in the 2 mm of channel downstream of the heater. This suggests that heat spreading from the hotspot played a vital role in dissipating the heat load.

42 ENGINEERING↗

Fluid & Thermal Analysis of a Manifold Microchannel Heat Sink

A three-dimensional (3-D) numerical model has been developed to study the fluid flow and heat transfer through a manifold-microchannel (MMC) heat sink, a microfluidic cooling system designed as a heat dissipation solution for compact, high-powered electronic systems. An MMC consists of a 3-D manifold structure that distributes working fluid through alternating inlet and outlet manifold channels that guide the fluid to and from the microchannels, shortening the flow length and thereby, reducing the pressure drop across the system. Wide bandgap semiconductors such as silicon carbide (SiC) are increasingly utilized due to their ability to enable smaller electronic devices and components to operate more efficiently at higher frequencies. These semiconductors can greatly benefit from the MMC, which can extract all the heat produced by compact, high-powered electronics, enabling them to achieve optimal performance. The MMC also utilizes an embedded cooling approach which allows for fabrication directly within SiC-based electronics, resulting in significant mass and weight savings and lower thermal resistance than conventional heat sink designs. This paper outlines the methods used to conduct fluid and thermal analysis of different MMC configurations for flow parameters such as flow rate and inlet flow conditions. This study involves both steady state and transient thermal analysis as a gradually increasing heat flux is applied to the system over time, which is representative of the heat dissipation from the electronics over a given period. Results from the analysis show that the MMC is capable of effectively dissipating heat flux of ~100 W/cm2 while maintaining considerably low pressure drop (< 1 kPa) and thermal resistance (< 1 K/W) for certain single-phase working fluids.

manifold microchannel↗

Fluid & Thermal Analysis of a Manifold Microchannel Heat Sink

A three-dimensional (3-D) numerical model has been developed to study the fluid flow and heat transfer through a manifold-microchannel (MMC) heat sink, a microfluidic cooling system designed as a heat dissipation solution for compact, high-powered electronic systems. An MMC consists of a 3-D manifold structure that distributes working fluid through alternating inlet and outlet manifold channels that guide the fluid to and from the microchannels, shortening the flow length and thereby, reducing the pressure drop across the system. Wide bandgap semiconductors such as silicon carbide (SiC) are increasingly utilized due to their ability to enable smaller electronic devices and components to operate more efficiently at higher frequencies. These semiconductors can greatly benefit from the MMC, which can extract all the heat produced by compact, high-powered electronics, enabling them to achieve optimal performance. The MMC also utilizes an embedded cooling approach which allows for fabrication directly within SiC-based electronics, resulting in significant mass and weight savings and lower thermal resistance than conventional heat sink designs. This paper outlines the methods used to conduct fluid and thermal analysis of different MMC configurations for flow parameters such as flow rate and inlet flow conditions. This study involves both steady state and transient thermal analysis as a gradually increasing heat flux is applied to the system over time, which is representative of the heat dissipation from the electronics over a given period. Results from the analysis show that the MMC is capable of effectively dissipating heat flux of ~100 W/cm2 while maintaining considerably low pressure drop (< 1 kPa) and thermal resistance (< 1 K/W) for certain single-phase working fluids.

manifold microchannel↗

Slip velocity boundary conditions for the lattice Boltzmann modeling of microchannel flows

Abstract Slip flows in ducts are important in numerous engineering applications, most notably in microchannel flows. Compared to the standard no‐slip Dirichlet condition, the case of slip formulates as a Robin‐type condition for the fluid tangential velocity. Such an increase in mathematical complexity is accompanied by a more challenging numerical transcription. The present work concerns with this topic, addressing the modeling of the slip velocity boundary condition in the lattice Boltzmann method (LBM) applied to steady slow viscous flows inside ducts of nontrivial shapes. As novelty, we extend the newly revised local second‐order boundary (LSOB) Dirichlet fluid flow method [ Philos. Trans. R. Soc. A 378, 20190404 (2020)] to implement the slip velocity condition within the two‐relaxation‐time (TRT) framework. The LSOB follows an in‐node philosophy where its operation principle seeks to explicitly reconstruct the unknown boundary populations in the form of a third‐order accurate Chapman–Enskog expansion, where the wall slip condition is built‐in as a normal Taylor‐type condition. The key point of this approach is that the required first‐ and second‐order momentum derivatives, rather than computed through nonlocal finite difference approximations, are locally determined through a simple local linear algebra procedure, whose formulation is particularly aided by the TRT symmetry argument. To express the obtained derivatives, two approaches are considered, called and , which operate with node and wall variables, respectively. These two formulations are developed to prescribe the physical slip condition over plane and curved walls, including the corners. Their consistency and accuracy characteristics are examined against alternative linkwise strategies to impose the wall slip velocity, such as the kinetic‐based diffusive bounce‐back scheme, the central linear interpolation slip scheme, and the multireflection slip scheme. The several slip schemes are tested over different 3D microchannel configurations, with walls not conforming with the LBM uniform mesh. Numerical tests confirm the advanced accuracy characteristics of the proposed LSOB slip boundary scheme, revealing the added challenge of the wall slip modeling, and that parabolic accuracy is a necessary requirement to reach second‐order accuracy within this problem class.

Silva, Goncalo↗

A remarkable CHF of 345W/cm 2 is achieved in a wicked-microchannel using HFE-7100

Boiling heat transfer of dielectric fluids is a promising cooling technique for thermal management of microelectronic systems. However, the critical heat flux achievable is generally low, because of the poor thermophysical properties of these fluids. Here, to address this dilemma, we propose a new cooling concept to substantially enhance global liquid supply during phase-change process using enhanced capillary-driven force. Additionally, dedicated vapor pathways are designed among a bank of micro-pillars to facilitate vapor removal. In this work, new wicks comprised of silicon micro-pinfin arrays are explored to significantly enhance the flow boiling heat transfer performance. To examine the functionalities of this wick, experiments on HFE-7100 were carried out with mass velocities varying from 247 to 3,465 kg/m 2 s. To explore the enhancement mechanisms and to analyze the capillary-assisted flow boiling process, visualization studies were conducted. The results indicate that sustainable evaporation induced by wick microstructures and efficient liquid supply are the enhancement mechanisms compared to parallel microchannels with solid walls. It is found that the overall heat transfer coefficient is substantially increased up to 75%. Remarkably, a high critical heat flux (CHF) of approximately 345 W/cm 2 is recorded at G = 3,465 kg/m 2 s at coolant inlet temperature of ~20 °C. Equally importantly, this noticeable enhancement of CHF value is associated with drastically decreased pressure drops compared to microchannels decorated with μ-pinfin fences.

36 MATERIALS SCIENCE↗

Tracking rare-isotope beams with microchannel plates

A system of two microchannel-plate detectors has been successfully implemented for tracking projectile-fragmentation beams. The detectors provide interaction positions, angles, and arrival Limes of ions at the reaction target. Furthermore, the current design is an adaptation of an assembly used for low-energy beams (~1.4 MeV/nucleon). In order to improve resolution in tracking high-energy heavy-ion beams, the magnetic field strength between the secondary-electron accelerating foil and the microchannel plate had to be increased substantially. Results from an experiment using a 37-MeV/nucleon 56 Ni beam show that the tracking system can achieve sub-nanosecond timing resolution and a position resolution of ~1 mm for beam intensities up to 5 x 10 5 pps.

43 PARTICLE ACCELERATORS↗

Exopolysaccharide microchannels direct bacterial motility and organize multicellular behavior

The myxobacteria are a family of soil bacteria that form biofilms of complex architecture, aligned multilayered swarms or fruiting body structures that are simple or branched aggregates containing myxospores. Here, we examined the structural role of matrix exopolysaccharide (EPS) in the organization of these surface-dwelling bacterial cells. Using time-lapse light and fluorescence microscopy, as well as transmission electron microscopy and focused ion beam/scanning electron microscopy (FIB/SEM) electron microscopy, we found that Myxococcus xanthus cell organization in biofilms is dependent on the formation of EPS microchannels. Cells are highly organized within the three-dimensional structure of EPS microchannels that are required for cell alignment and advancement on surfaces. Mutants lacking EPS showed a lack of cell orientation and poor colony migration. Purified, cell-free EPS retains a channel-like structure, and can complement EPS - mutant motility defects. In addition, EPS provides the cooperative structure for fruiting body formation in both the simple mounds of M. xanthus and the complex, tree-like structures of Chondromyces crocatus . We furthermore investigated the possibility that EPS impacts community structure as a shared resource facilitating cooperative migration among closely related isolates of M. xanthus .

59 BASIC BIOLOGICAL SCIENCES↗

Microchannel contacting of crystalline silicon solar cells

There is tremendous interest in reducing losses caused by the metal contacts in silicon photovoltaics, particularly the optical and resistive losses of the front metal grid. One commonly sought-after goal is the creation of high aspect-ratio metal fingers which provide an optically narrow and low resistance pathway to the external circuit. Currently, the most widely used metal contact deposition techniques are limited to widths and aspect-ratios of ~40 μm and ~0.5, respectively. In this study, we introduce the use of a micropatterned polydimethylsiloxane encapsulation layer to form narrow (~20 μm) microchannels, with aspect-ratios up to 8, on the surface of solar cells. We demonstrate that low temperature metal pastes, electroless plating and atomic layer deposition can all be used within the microchannels. Further, we fabricate proof-of-concept structures including simple planar silicon heterojunction and homojunction solar cells. While preliminary in both design and efficiency, these results demonstrate the potential of this approach and its compatibility with current solar cell architectures.

14 SOLAR ENERGY↗

Rapid prototyping of microchannels with surface patterns for fabrication of polymer fibers

Microfluidic technology has provided innovative solutions to numerous problems, but the cost of designing and fabricating microfluidic channels is impeding its expansion. In this study, Shrinky-Dink thermoplastic sheets are used to create multilayered complex templates for microfluidic channels. We also used inkjet and laserjet printers to raise a predetermined microchannel geometry by depositing several layers of ink for each feature consecutively. We achieved feature heights over 100 μm, which were measured and compared with surface profilometry. Templates closest to the target geometry were then used to create microfluidic devices from soft-lithography with the molds as a template. These microfluidic devices were, futhermore used to fabricate polymer microfibers using the microfluidic focusing approach to demonstrate the potential that this process has for microfluidic applications. Finally, an economic analysis was conducted to compare the price of common microfluidic template manufacturing methods. We showed that multilayer microchannels can be created significantly quicker and cheaper than current methods for design prototyping and point-of-care applications in the biomedical area.

42 ENGINEERING↗

In situ nuclear magnetic resonance microimaging of live biofilms in a microchannel

Nuclear magnetic resonance (NMR) microimaging and spectroscopy was used to interrogate fluids of biological importance (e.g., water, buffer, medium solution) and live biofilms in a microchannel compatible for analyses at ambient pressure and under vacuum. Studies using buffer, growth medium, and actively growing Shewanella oneidensis biofilms were used to demonstrate in situ NMR microimaging measurement capabilities including velocity mapping, diffusion coefficient mapping, relaxometry, localized spectroscopy, and 2D and 3D imaging within a microchannel suitable for different analytical platforms. This technique is promising for diverse applications of correlative imaging using a portable microfluidic platform.

biofilm↗

Occurrence of Knudsen minima in diverging microchannels

Rarefied gas flow is gaining increasing importance with the emergence of Micro Electro Mechanical Systems (MEMS). Knudsen minima is one of the characteristic feature of such rarefied flows and has been observed in uniform cross section channels such as plane channel, cylindrical tube and annulus. However, data pertaining to gaseous flow in varying cross section channel is relatively sparse. Channels of varying cross section are frequently encountered in MEMS devices and are fundamental to the design of micro-scale nozzles and micro-valves. In this context, rarefied gas flow through a diverging microchannel (divergence angle – 12 degree) is studied experimentally with three different gases (argon, nitrogen and oxygen). The experiments are performed over a wide range with the mean Knudsen number varying from slip to the transitional regime (0.07 to 1.2). It is found that the effect of molecular weight of the gas on the non-dimensional mass flow rate is negligible. The Knudsen minima is experimentally observed for the first time in microchannel of non-uniform cross section.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fabrication of microchannels in fused silica using femtosecond Bessel beams

Extended birefringent waveguiding microchannels up to 15 mm long were created inside fused silica by single-pulse irradiation with femtosecond Bessel beams. The birefringent refractive index change of 2–4 × 10{sup −4} is attributed to residual mechanical stress. The microchannels were chemically etched in KOH solution to produce 15 mm long microcapillaries with smooth walls and a high aspect ratio of 1:250. Bessel beams provide higher speed of material processing compared to conventional multipulse femtosecond laser micromachining techniques and permit simple control of the optical axis direction of the birefringent waveguides, which is important for practical applications [Corrielli et al., “Rotated waveplates in integrated waveguide optics,” Nat. Commun. 5, 4249 (2014)].

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Response of a lead-free borosilicate-glass microchannel plate to 14-MeV neutrons and γ-rays

In microchannel plate applications, such as in space telescopes, night-vision devices, or time-of-flight particle detection, reducing the sensitivity to signals from background sources, such as γ-rays, is beneficial for the system design and performance. The response of a single-stage lead-free borosilicate-glass microchannel plate to 14-MeV neutrons and γ-rays produced via (n, γ) reactions in surrounding structures was investigated at OMEGA. The average efficiency values for secondary electron production were found to be (5.1 ± 0.7) × 10−3 for 14-MeV neutrons and (4.9 ± 1.1) × 10−3 for ⟨1.5⟩-MeV γ-rays.

Parker, C. E. (ORCID:0000000303626984)↗

Spatially-periodic microplasmas in complex microchannel networks: wall-plasma interactions and dynamic behavior

Wall-plasma interactions have been observed for spatially-periodic microplasmas generated in 300–700 µm wide channels fabricated in nanoporous alumina. Examination of Ne microplasma discs produced in a standing-wave pattern in Al 2 O 3 channels illustrates the competition between electron production at the sheath-wall interface and loss by recombination in an atmospheric pressure background. Two topologies of the microplasma arrays are observed. For channel widths (d) less than 450 µm, the microplasmas are generally centered in the channel and sustained by electron generation at both plasma sheath/channel wall interfaces, presumably including the release of charge residing in the hexagonal alumina pores. As d is progressively increased from 300 to 450 µm, the microchannel plasma cross-section is gradually transformed from circular to elliptical, and its surface area declines by as much as 50% so as to minimize e - losses to the background gas. Increasing d above ~450 µm abruptly switches the topology to one in which plasmas having a triangular cross-section attach to one of the channel walls in a pattern that alternates along the channel axis. Microfabricating trapezoidal cross-section channels into complex geometries, including the Cornu spiral and intersecting linear arrays, also reveals dynamic behavior in the propagation of microplasmas. For a common spiral structure, observations of plasma expansion show the wavefront propagates over the corrugated surface or within the channel with radial and azimuthal velocities of 3 ± 1 km s -1 and 8 ± 1.5 km s -1 , respectively. Plasma formation is initiated in each ring of the spiral through electron seeding by streamers propagating radially outward at velocities approaching 200 km s -1 . In addition to electrostatic charge-mediated variations in the mean separation between adjacent microplasmas, the time-dependent interference between two 1D microplasma arrays has been observed during plasma expansion. Reproducible ignition of a microplasma ensemble along ridges micromachined into channels near the intersections of two linear arrays has also been realized. The results reported here demonstrate that microchannels with the walls overcoated with any of a variety of materials provide a promising platform for examining in detail the interaction of low temperature plasma with a surface of arbitrary composition and topography.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A microchannel for in vitro imaging of erythrocyte shape transformations by video microscopic technique

SummaryAn in-house fabricated microfluidic channel was developed using easily available materials (glass slide, transparency shapes, polyvinyl chloride tubes, coverslip, and epoxy) and manual positioning techniques with the aid of a profile projector, in the absence of other fabrication facilities.{sup 2,3,11–15} Despite the limitations of being less accurate and more laborious, manual methods offer an easy, inexpensive, and readily implementable alternative to automated ones. Being economical, they enable testing of newer models and hypothesis, development of new designs, and trail stage/prototype experimentation. Once the effectiveness of the developed channel is established, the manual fabrication method can eventually be automated. So far as erythrocyte deformability is concerned, the microchannel thus fabricated enabled multishape erythrocyte deformability analysis in contrast to the unishape approach by earlier studies.{sup 11–15,19} Though the microchannel in this study has larger width (30 μm) compared to the mean RBC diameter (~8 μm), it allows free orientation of cells and larger variation of shear condition across the channel cross section. Consequently, both asymmetrical and axial shapes were observed during the flow. Hence, it may be concluded that a larger cross section and medium to high flow (10–20 mm/s) may be appropriate for multishape characterization of erythrocytes in dilute suspensions. The issue of determining the DI for several deformed shapes and sorting them from other interacting and nondeforming RBCs could be handled with more flexible software techniques.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Using Membranes with Internal Microchannels to Prevent Drying-out during CO 2 Electrolysis

Scaling up CO 2 electrolysis is a vital aspect in the transition to manufacturing sustainable fuels and chemical compounds, satisfying the demand for chemicals and demand for storing renewable electricity. Depending on the employed catalyst, different products can be produced, such as carbon monoxide and ethylene, by applying a voltage on a CO 2 and H 2 O fed electrolyzer. CO is a desirable product according to techno-economic analysis, because it can be produced selectively using a silver catalyst and is a precursor for hydrocarbons in the Fischer–Tropsch process. In a state-of-the-art CO 2 electrolyzer, two electrodes are directly pressed against an ion-exchange membrane – this is called a zero-gap configuration. Therefore, the membrane is a crucial component for the system, since it has the role of providing a conductive medium between the electrodes. One of the challenges in CO 2 electrolysis is that water is consumed in the reaction. At high current density, this may cause the membrane's surface near the cathode to dry out, lowering efficiency or perhaps stopping the process entirely, since there is no longer a conductive medium. As a result, water management is critical for this process. In this work, we approach the drying-out challenge by studying the novel concept of a membrane with internal microchannels. These channels allow the circulation of water or an electrolyte inside the membrane, which reduces the water diffusion path and affects the membrane’s conductivity. The effects of channel geometry, location, and concentrations of electrolyte inside on water content, conductivity and overall performance are studied in a 2D COMSOL model. In addition, the effect of internal concentration of electrolyte on the membrane’s resistance, on the process performance and the K + cross-over to cathode side were investigated experimentally. Our modeling results prove that the presence of the channels can keep the membrane hydrated. The highest current densities are observed when the channel is closest to the cathode, and with smaller pores. Smaller pores are advantageous due to the trade-off between enhanced membrane conductivity and the lower conductivity of the liquid itself. If water is circulated in a large channel, it increases the membrane’s ionomer conductivity due to hydration but the overall conductivity is decreased since water is not highly conductive. Nonetheless, the results also show that a higher concentration of electrolyte inside the microchannels can significantly increase the total conductivity of the membrane, and therefore the energy efficiency of the process. These effects are most significant at higher current densities. In the experimental results, we’ve observed similar effects in terms of membrane conductivity and current density of the process – the higher the electrolyte concentration the higher the current density. Furthermore, a low concentration decreases the amount of potassium which crosses over to the cathode side, inhibiting salt deposition. We’ve concluded that a small channel, up to 90 µm wide, close to the pore with an electrolyte with a concentration of up to 10 mM could be very beneficial for the water management and energy efficiency of the process. This helps to keep the membrane hydrated at higher current densities, improves the conductivity of the membrane, and it doesn’t have significant impacts on the salt deposition.

Petrov, Kostadin Veselinov↗

Joule-class THz pulses from microchannel targets

Inference of joule-class THz radiation sources from microchannel targets driven with hundreds of joule, picosecond lasers is reported. Here, THz sources of this magnitude are useful for nonlinear pumping of matter and for charged-particle acceleration and manipulation. Microchannel targets demonstrate increased laser–THz conversion efficiency compared to planar foil targets, with laser energy to THz energy conversion up to ~0.9% in the best cases.

47 OTHER INSTRUMENTATION↗

Microchannel Reactor System for Catalytic Hydrogenation

We successfully demonstrated a novel process intensification concept enabled by the development of microchannel reactors, for energy efficient catalytic hydrogenation reactions at moderate temperature, and pressure, and low solvent levels. We designed, fabricated, evaluated, and optimized a laboratory-scale microchannel reactor system for hydrogenation of onitroanisole and a proprietary BMS molecule. In the second phase of the program, as a prelude to full-scale commercialization, we designed and developed a fully-automated skid-mounted multichannel microreactor pilot plant system for multiphase reactions. The system is capable of processing 1 – 10 kg/h of liquid substrate, and an industrially relevant immiscible liquid-liquid was successfully demonstrated on the system. Our microreactor-based pilot plant is one-of-akind. We anticipate that this process intensification concept, if successfully demonstrated, will provide a paradigm-changing basis for replacing existing energy inefficient, cost ineffective, environmentally detrimental slurry semi-batch reactor-based manufacturing practiced in the pharmaceutical and fine chemicals industries.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗