Search NASA⌕ Search

SEARCH · Search NASA

Results for “Microscope and microscopy.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Indium-bump-free antimonide superlattice membrane detectors on silicon substrates

We present an approach to realize antimonide superlattices on silicon substrates without using conventional Indium-bump hybridization. In this approach, PIN superlattices are grown on top of a 60 nm Al0.6Ga0.4Sb sacrificial layer on a GaSb host substrate. Following the growth, the individual pixels are transferred using our epitaxial-lift off technique, which consists of a wet-etch to undercut the pixels followed by a dry-stamp process to transfer the pixels to a silicon substrate prepared with a gold layer. Structural and optical characterization of the transferred pixels was done using an optical microscope, scanning electron microscopy, and photoluminescence. The interface between the transferred pixels and the new substrate was abrupt, and no significant degradation in the optical quality was observed. An Indium-bump-free membrane detector was then fabricated using this approach. Spectral response measurements provided a 100% cut-off wavelength of 4.3 μm at 77 K. The performance of the membrane detector was compared to a control detector on the as-grown substrate. The membrane detector was limited by surface leakage current. The proposed approach could pave the way for wafer-level integration of photonic detectors on silicon substrates, which could dramatically reduce the cost of these detectors.

Zamiri, M. (ORCID:000000020042735X)↗

Hard x-ray scanning microscopy with coherent radiation: Beyond the resolution of conventional x-ray microscopes

We demonstrate x-ray scanning coherent diffraction microscopy (ptychography) with 10 nm spatial resolution, clearly exceeding the resolution limits of conventional hard x-ray microscopy. The spatial resolution in a ptychogram is shown to depend on the shape (structure factor) of a feature and can vary for different features in the object. In addition, the resolution and contrast are shown to increase with increasing coherent fluence. For an optimal ptychographic x-ray microscope, this implies a source with highest possible brilliance and an x-ray optic with a large numerical aperture to generate the optimal probe beam.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nanopore fabrication and characterization by helium ion microscopy

The Helium Ion Microscope (HIM) has the capability to image small features with a resolution down to 0.35 nm due to its highly focused gas field ionization source and its small beam-sample interaction volume. In this work, the focused helium ion beam of a HIM is utilized to create nanopores with diameters down to 1.3 nm. It will be demonstrated that nanopores can be milled into silicon nitride, carbon nanomembranes, and graphene with well-defined aspect ratio. To image and characterize the produced nanopores, helium ion microscopy and high resolution scanning transmission electron microscopy were used. The analysis of the nanopores' growth behavior allows inferring on the profile of the helium ion beam.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Microscopic infrared analysis by X-ray or electron radiation

An infrared (IR) emission spectroscopy and microscopy apparatus with X-ray excitation or electron excitation and an improved process for extending spatial relation of infrared (IR) microscopy and performing microscopic infrared (IR) analysis by X-ray or electron radiation are provided. By utilizing nanometer sized X-ray beams or electron beams to produce IR emission, the spatial resolution of IR microscopy is extended. Simultaneously performing X-ray or electron-based spectroscopy as well as structural studies are enabled.

42 ENGINEERING↗

Atmospheric pressure scanning transmission electron microscopy

Scanning transmission electron microscope (STEM) images of gold nanoparticles (2.1 nm average diameter) at atmospheric pressure have been recorded through a 0.36 mm thick mixture of CO, O2 and He. This was accomplished using a reaction cell consisting of two electron-transparent silicon nitride membranes mounted on a specially designed specimen rod. Gas flow occurred through plastic tubing from the outside of the microscope to the specimen region and back. Gold nanoparticles of a full width half maximum diameter of 1.0 nm were visible above the background noise and the achieved resolution was 0.5 nm in accordance with calculations of the beam broadening.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Improved crystalline properties of laser molecular beam epitaxy grown SrTiO{sub 3} by rutile TiO{sub 2} layer on hexagonal GaN

Epitaxial SrTiO{sub 3} films were fabricated by laser molecular beam epitaxy on bare and TiO{sub 2} buffered GaN(0002), respectively. The whole deposition processes were in situ monitored by reflection high energy electron diffraction (RHEED). X-ray diffraction (XRD) was carried out to study the growth orientation and crystalline quality of STO films. The interfacial characters and epitaxial relationships were also investigated by high revolution transition electron microscope and selected area electron diffraction (SAED). According to the RHEED observation, the lowest epitaxy temperature of STO on TiO{sub 2} buffered GaN was decreased compared with the direct deposited one. The epitaxial relationship was (111)[110]STO//(0002)[1120]GaN in both cases as confirmed by RHEED, XRD, and SAED. The full width at half maximum of omega-scan and PHI-scan of STO on TiO{sub 2} buffered GaN was reduced compared with that deposited on bare GaN, indicating that epitaxial quality of STO film is improved by inserting TiO{sub 2} layer. In summary, the lattice mismatch was reduced by inserting rutile TiO{sub 2}. As a result, the crystalline temperature was reduced and enhanced epitaxial quality of STO thin film was obtained.

36 MATERIALS SCIENCE↗

Characterization Of An EBL System: The Influence Of Process Parameters On Thickness Resist And Engraving Shapes

In LIGA process, the low flexibility due to the use of masks might be overcome using the electron beam of a scansion electron microscope (SEM) instead of the synchrotron radiation. In this way, through the vector control of the beam, it is possible to irradiate a specific path on the resist without using any mask. Anyway, it is important to remark that the Electron Beam Lithography (EBL) can not include all the applications of the X-ray LIGA technique but it could be a valid alternative only for some specific uses. In particular, some limits concerning the impression of high thickness resists are expected. An EBL system based on a SEM was recently implemented by the authors and some tests were carried out to characterize the device performances. Aim of this work is to asses the system performances in terms of maximum impressible thickness resist and shape of the engraved entities. Several tests were carried out by varying the resist thickness and the process parameters.

07 ISOTOPE AND RADIATION SOURCES↗

Correlation in a coherent electron beam

Correlations between successive detections in beams of free electrons are studied with a transmission electron microscope. For incoherent illumination of the detectors, a certain random coincidence probability is observed, indicative for uncorrelated arrival times of the electrons. When the illumination is changed from incoherent to coherent, a reduction of the random coincidence probability is observed, indicative for antibunching in the arrival times of the electrons. However, the amount of reduction is larger than the theoretically expected value calculated from the Pauli principle, forbidding more than one identical fermion to occupy the same quantum state. For a certain coherent illumination of the detectors, where we use magnetic lenses in electron microscopes for magnifications of the coherence length, we find an enhanced coincidence probability, indicative for bunching in the arrival times of the electrons. This originates from correlations in beams of free electrons due to Coulomb interactions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scanning He+ Ion Beam Microscopy and Metrology

The CD-SEM has been the tool of choice for the imaging and metrology of semiconductor devices for the past three decades but now, with critical dimensions at the nanometer scale, electron beam instruments can no longer deliver adequate performance. A scanning microscope using a He+ ion beam offers superior resolution and depth of field, and provides enhanced imaging contrast. Device metrology performed using ion beam imaging produces data which is comparable to or better than that from a conventional CD-SEM although there are significant differences in the experimental conditions required and in the details of image formation. The charging generated by a He+ beam, and the sample damage that it can cause, require care in operation but are not major problems.

36 MATERIALS SCIENCE↗

Fabrication of optical multilayer for two-color phase plate in super-resolution microscope

In super-resolution microscopy based on fluorescence depletion, the two-color phase plate (TPP) is an indispensable optical element, which can independently control the phase shifts for two beams of different color, i.e., the pump and erase beams. By controlling a phase shift of the erase beam through the TPP, the erase beam can be modulated into a doughnut shape, while the pump beam maintains the initial Gaussian shape. To obtain a reliable optical multiplayer (ML) for the TPP, we designed a ML with only two optical layers by performing numerical optimization. The measured phase shifts generated by the fabricated ML using interferometry correspond to the design values. The beam profiles in the focal plane are also consistent with theoretical results. Although the fabricated ML consists of only two optical layers, the ML can provide a suitable phase modulation function for the TPP in a practical super-resolution microscope.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

LiMnPO4·Li3V2(PO4)3 composite cathode material derived from Mn(VO3)2 nanosheet precursor

The LiMnPO4·Li3V2(PO4)3/C composite cathode material was synthesized from Mn(VO3)2 nanosheet precursor, which was prepared by a hydrothermal method. The structure and morphology of the composite were systematically investigated by powder X-ray diffraction (XRD), scanning electron microscopy (SEM), transmission electron microscope (TEM) and scanning transmission electron microscopy (STEM), etc. The LiMnPO4·Li3V2(PO4)3/C composite material exhibits a low polarization and high specific capacity of 150.7 mAh g-1 at 0.1C in voltage range of 2.5–4.5V, and excellent cycle and rate performance for its stable nanocomposite framework. The composite material dominantly exists in the morphological shape of nanograins and nanorods, which increases the surface area and hence facilitate the electrolyte penetration. The nanoparticle components were even further identified in detail.

Lei, Zhihong↗

α-Synuclein amyloid fibrils with two entwined, asymmetrically associated protofibrils [α-Synuclein amyloid fibrils with two entwined, asymmetrically associated, protofibrils and axially stacked metal binding sites]

Parkinson disease and other progressive neurodegenerative conditions are characterized by the intracerebral presence of Lewy bodies, containing amyloid fibrils of α-synuclein. We used cryo-electron microscopy and scanning transmission electron microscopy (STEM) to study in vitro -assembled fibrils. These fibrils are highly polymorphic. Focusing on twisting fibrils with an inter-crossover spacing of 77 nm, our reconstructions showed them to consist of paired protofibrils. STEM mass per length data gave one subunit per 0.47 nm axial rise per protofibril, consistent with a superpleated β-structure. The STEM images show two thread-like densities running along each of these fibrils, which we interpret as ladders of metal ions. These threads confirmed the two-protofibril architecture of the 77-nm twisting fibrils and allowed us to identify this morphotype in STEM micrographs. Some other, but not all, fibril morphotypes also exhibit dense threads, implying that they also present a putative metal binding site. As a result, we propose a molecular model for the protofibril and suggest that polymorphic variant fibrils have different numbers of protofibrils that are associated differently.

59 BASIC BIOLOGICAL SCIENCES↗

The Scanning Electron Microscope As An Accelerator For The Undergraduate Advanced Physics Laboratory

Few universities or colleges have an accelerator for use with advanced physics laboratories, but many of these institutions have a scanning electron microscope (SEM) on site, often in the biology department. As an accelerator for the undergraduate, advanced physics laboratory, the SEM is an excellent substitute for an ion accelerator. Although there are no nuclear physics experiments that can be performed with a typical 30 kV SEM, there is an opportunity for experimental work on accelerator physics, atomic physics, electron-solid interactions, and the basics of modern e-beam lithography.

99 GENERAL AND MISCELLANEOUS↗

Visualizing and Quantifying the Cationic Mobility at {100} Surfaces of Ceria: Application to CO 2 Adsorption/Desorption Phenomena in the Environmental Transmission Electron Microscope

Environmental transmission electron microscopy in a dedicated instrument allows ultimate spatial resolution with chemical analysis capabilities similar to high resolution transmission electron microscopes (HRTEMs), while retaining partial pressures up to 20 mbar around the specimen. Finally, such instruments provide an optimized approach to study the early stages of catalytic reactions, which can start from very low partial pressure, at the atomic-scale.

36 MATERIALS SCIENCE↗

Radiation microscope for SEE testing using GeV ions.

Radiation Effects Microscopy is an extremely useful technique in failure analysis of electronic parts used in radiation environment. It also provides much needed support for development of radiation hard components used in spacecraft and nuclear weapons. As the IC manufacturing technology progresses, more and more overlayers are used; therefore, the sensitive region of the part is getting farther and farther from the surface. The thickness of these overlayers is so large today that the traditional microbeams, which are used for REM are unable to reach the sensitive regions. As a result, higher ion beam energies have to be used (> GeV), which are available only at cyclotrons. Since it is extremely complicated to focus these GeV ion beams, a new method has to be developed to perform REM at cyclotrons. We developed a new technique, Ion Photon Emission Microscopy, where instead of focusing the ion beam we use secondary photons emitted from a fluorescence layer on top of the devices being tested to determine the position of the ion hit. By recording this position information in coincidence with an SEE signal we will be able to indentify radiation sensitive regions of modern electronic parts, which will increase the efficiency of radiation hard circuits.

43 PARTICLE ACCELERATORS↗

Correlation between resistance-change effect in transition-metal oxides and secondary-electron contrast of scanning electron microscope images

Conductive atomic-force microscopy (C-AFM) writing is attracting attention as a technique for clarifying the switching mechanism of resistive random-access memory by providing a wide area filled with filaments, which can be regarded as one filament with large radius. The writing area on a nickel-oxide (NiO) film formed by conductive atomic-force microscopy was observed by scanning electron microscope, and a correlation between the contrast in a secondary-electron image (SEI) and the resistance written by C-AFM was revealed. In addition, the dependence of the SEI contrast on the beam accelerating voltage (V{sub accel}) suggests that the resistance-change effect occurs near the surface of the NiO film. As for the effects of electron irradiation and vacuum annealing on the C-AFM writing area, it was shown that the resistance-change effect is caused by exchange of oxygen with the atmosphere at the surface of the NiO film. This result suggests that the low-resistance and high-resistance areas are, respectively, p-type Ni{sub 1+{delta}}O ({delta} < 0) and insulating (stoichiometric) or n-type Ni{sub 1+{delta}}O ({delta}{>=} 0).

36 MATERIALS SCIENCE↗