Full-scale altitude engine test of a turbofan exhaust-gas-forced mixer to reduce thrust specific fuel consumption

The specific fuel consumption of a low-bypass-ratio, confluent-flow, turbofan engine was measured with and without a mixer installed. Tests were conducted for flight Mach numbers from 0.3 to 1.4 and altitudes from 10,670 to 14,630 meters (35,000 to 48,000 ft) for core-stream-to-fan-stream temperature ratios of 2.0 and 2.5 and mixing-length-to-diameter ratios of 0.95 and 1.74. For these test conditions, the reduction in specific fuel consumption varied from 2.5 percent to 4.0 percent. Pressure loss measurements as well as temperature and pressure surveys at the mixer inlet, the mixer exit, and the nozzle inlet were made.

Cullom, R. R.↗

A 230-GHz radiometer system employing a second-harmonic mixer

A radiometer system for use in the 1.3 mm region has been constructed and used for radio astronomical observations. A second-harmonic mixer employing a single Schottky diode downconverts the incident power to an IF frequency of about 1400 MHz. The measured double-sideband system noise temperature is 6000 K (noise figure = 13 dB) and the double-sideband mixer conversion loss is calculated to be 10 dB. The mixer is tunable over a range of at least 15 GHz.

Goldsmith, P. F.↗

A new mixer design for 140-220 GHz

A new Schottky-diode mixer is described which has low noise and conversion loss in the 140-220-GHz band. At 170 GHz mixer noise temperatures of 1100-1300 K have been measured, with 6.2-7.2-dB single sideboard conversion loss. The design should be usable up to about 300 GHz with appropriate scaling. The mixer has been successfully used in airborne radiometers on the NASA Convair 990 and C-141 aircraft.

Kerr, A. R.↗

A three-dimensional turbulent compressible flow model for ejector and fluted mixers

A three dimensional finite element computer code was developed to analyze ejector and axisymmetric fluted mixer systems whose flow fields are not significantly influenced by streamwise diffusion effects. A two equation turbulence model was used to make comparisons between theory and data for various flow fields which are components of the ejector system, i.e., (1) turbulent boundary layer in a duct; (2) rectangular nozzle (free jet); (3) axisymmetric nozzle (free jet); (4) hypermixing nozzle (free jet); and (5) plane wall jet. Likewise, comparisons of the code with analytical results and/or other numerical solutions were made for components of the axisymmetric fluted mixer system. These included: (1) developing pipe flow; (2) developing flow in an annular pipe; (3) developing flow in an axisymmetric pipe with conical center body and no fluting and (4) developing fluted pipe flow. Finally, two demonstration cases are presented which show the code's ability to analyze both the ejector and axisymmetric fluted mixers.

Rushmore, W. L.↗

Progress on millimeter wave Josephson junction mixers

Preset, recyclable Nb point contacts are tested as low-noise Josephson mixers at a signal frequency of 115 GHz. The best result achieved is a mixer noise temperature (single sideband) of 120 K with unity conversion efficiency (SSB) for a junction at 6 K. Variation of mixer properties with temperature and other parameters is presented.

Taur, Y.↗

Turbofan forced mixer-nozzle internal flowfield. Volume 1: A benchmark experimental study

An experimental investigation of the flow field within a model turbofan forced mixer nozzle is described. Velocity and thermodynamic state variable data for use in assessing the accuracy and assisting the further development of computational procedures for predicting the flow field within mixer nozzles are provided. Velocity and temperature data suggested that the nozzle mixing process was dominated by circulations (secondary flows) of a length scale on the order the lobe dimensions which were associated with strong radial velocities observed near the lobe exit plane. The 'benchmark' model mixer experiment conducted for code assessment purposes is discussed.

Paterson, R. W.↗

Turbofan forced mixer-nozzle internal flowfield. Volume 3: A computer code for 3-D mixing in axisymmetric nozzles

A finite difference method is developed for making detailed predictions of three dimensional subsonic turbulent flow in turbofan lobe mixers. The governing equations are solved by a forward-marching solution procedure which corrects an inviscid potential flow solution for viscous and thermal effects, secondary flows, total pressure distortion and losses, internal flow blockage and pressure drop. Test calculations for a turbulent coaxial jet flow verify that the turbulence model performs satisfactorily for this relatively simple flow. Lobe mixer flows are presented for two geometries typical of current mixer design. These calculations included both hot and cold flow conditions, and both matched and mismatched Mach number and total pressure in the fan and turbine streams.

Kreskovsky, J. P.↗

Static jet noise test results of four 0.35 scale-model QCGAT mixer nozzles

As part of the NASA Quiet Clean General Aviation Turbofan (QCGAT) engine mixer-nozzle exhaust system program, static jet exhaust noise was recorded at microphone angles of 45 to 155 deg relative to the nozzle inlet for a conventional profile coaxial nozzle and three 12-lobed coaxial mixer nozzles. Both flows in all four nozzles are internally mixed before being discharged from a single exhaust nozzle. The conventional profile coaxial nozzle jet noise is compared to the current NASA Lewis coaxial jet noise prediction and after applying an adjustment to the predicted levels based on the ratio of the kinetic energy of the primary and secondary flows, the prediction is within a standard deviation of 0.9 dB of the measured data. The mass average (mixed flow) prediction is also compared to the noise data for the three mixer nozzles with a reasonably good fit after applying another kinetic energy ratio adjustment (standard deviation of 0.7 to 1.5 dB with the measured data). The tests included conditions for the full-scale engine at takeoff (T.O.), cutback (86% T.O.) and approach (67% T.O.).

Groesbeck, D. E.↗

Three-dimensional inviscid flow analysis of turbofan forced mixers

A three-dimensional potential analysis has been formulated and applied to the inviscid flow over a turbofan forced mixer. The method uses a unique small disturbance formulation to analytically uncouple the circumferential flow from the radial and axial flow problem, thereby reducing the analysis to the solution of a series of axisymmetric problems. These equations are discretized using a flux volume formulation along a Cartesian grid. The method extends earlier applications of the Cartesian method to complex cambered geometries. The effects of power addition are also included within the potential formulation. Good agreement is obtained with an alternate small disturbance analysis for a symmetric mixer in a planar duct. In addition calculations showing pressure distributions and induced secondary vorticity fields are presented for practical turbofan mixer configurations, and where possible, comparison has been made with available experimental data.

Barber, T. J.↗

A general numerical analysis program for the superconducting quasiparticle mixer

A user-oriented computer program SISCAP (SIS Computer Analysis Program) for analyzing SIS mixers is described. The program allows arbitrary impedance terminations to be specified at all LO harmonics and sideband frequencies. It is therefore able to treat a much more general class of SIS mixers than the widely used three-frequency analysis, for which the harmonics are assumed to be short-circuited. An additional program, GETCHI, provides the necessary input data to program SISCAP. The SISCAP program performs a nonlinear analysis to determine the SIS junction voltage waveform produced by the local oscillator. The quantum theory of mixing is used in its most general form, treating the large signal properties of the mixer in the time domain. A small signal linear analysis is then used to find the conversion loss and port impedances. The noise analysis includes thermal noise from the termination resistances and shot noise from the periodic LO current. Quantum noise is not considered. Many aspects of the program have been adequately verified and found accurate.

Hicks, R. G.↗

Design and optimization of NbCN/PbBi mixer elements for heterodyne receivers

Superconductor-Insulator-Superconductor (SIS) quantum mixers provide a relatively new approach to millimeter wave mixing potentially offering conversion gain, a low local oscillator power demand and potential mixer temperatures near the quantum limit. This paper presents device modeling and fabrication development for NbCN lead-alloy submicron edge-contact SIS mixers for use at 115 GHz.

Lichtenberger, A. W.↗

Optimization of SIS mixer elements

Superconductor-Insulator-Superconductor (SIS) quantum mixers provide an approach to millimeter wave mixing - potentially offering conversion gain, a low local oscillator power demand, and potential mixer noise temperatures near the quantum limit. The development of a reliable fabrication technology for producing such high quality SIS devices for mixer applications in radio astronomy is the focus of the work.

Mattauch, Robert J.↗

NbN/MgO/NbN SIS tunnel junctions for submm wave mixers

The authors report on the fabrication and testing of all-refractory NbN/MgO/NbN SIS (superconductor-insulator-superconductor) tunnel junctions for use as high-frequency mixers. Progress in the development of techniques for the fabrication of submicron-area tunnel junctions is described. Junction structures which have been investigated include mesa, crossline, and edge geometries. Using reactive sputtering techniques, NbN tunnel junctions with critical currents in excess of 104 A/sq cm have been fabricated with Vm values as high as 65 mV and areas down to 0.1 sq micron. Specific capacitance measurements on NbN/MgO/NbN mesa-type tunnel junctions give values in the range 60-90 fF/sq micron. These SIS tunnel junctions have been integrated with antennas and coupling structures for mixer tests in a waveguide receiver at 207 GHz. Preliminary mixer results are reported.

Stern, J. A.↗

The evaluation of a metered mixer for RTV silicone for RSRM nozzle backfill operations

Metered mixing specifically for the RSRM backfill operation was investigated. Projected advantages were the elimination of waste RTV silicone produced in the operation and the elimination of entrapped air during the mix. Although metered mixing proved to be a viable method for mixing the Dow Corning DC 90-0006 rubber with its catalyst, applying the technology to the RSRM backfill operation has several disadvantages that are decisive. Use of a metered mixer would increase the amount of material that was being scraped for each backfill and increase the amount of time required to clean up the equipment after each operation. Therefore, use of metered static mixers is not recommended for use in the RSRM nozzle backfill operations. Because metered mixers proved to have significant disadvantages other methods of mixing and dispensing the RTV during the backfill operation are being investigated, and will be reported in a separate document.

Wardell, T. C.↗

Energy Efficient Engine exhaust mixer model technology report addendum; phase 3 test program

The Phase 3 exhaust mixer test program was conducted to explore the trends established during previous Phases 1 and 2. Combinations of mixer design parameters were tested. Phase 3 testing showed that the best performance achievable within tailpipe length and diameter constraints is 2.55 percent better than an optimized separate flow base line. A reduced penetration design achieved about the same overall performance level at a substantially lower level of excess pressure loss but with a small reduction in mixing. To improve reliability of the data, the hot and cold flow thrust coefficient analysis used in Phases 1 and 2 was augmented by calculating percent mixing from traverse data. Relative change in percent mixing between configurations was determined from thrust and flow coefficient increments. The calculation procedure developed was found to be a useful tool in assessing mixer performance. Detailed flow field data were obtained to facilitate calibration of computer codes.

Larkin, M. J.↗

Planar doped barrier devices for subharmonic mixers

An overview is given of planar doped barrier (PDB) devices for subharmonic mixer applications. A simplified description is given of PDB characteristics along with a more complete numerical analysis of the current versus voltage characteristics of typical structures. The analysis points out the tradeoffs between the device structure and the resulting characteristics that are important for mixer performance. Preliminary low-frequency characterization results are given for the device structures, and a computer analysis of subharmonic mixer parameters and performance is presented.

Lee, T. H.↗

Modelling and performance of Nb SIS mixers in the 1.3 mm and 0.8 mm bands

We describe the modeling and subsequent improvements of SIS waveguide mixers for the 200-270 and 330-370 GHz bands (Blundell, Carter, and Gundlach 1988, Carter et al 1991). These mixers are constructed for use in receivers on IRAM radiotelescopes on Pico Veleta (Spain, Sierra Nevada) and Plateau de Bure (French Alps), and must meet specific requirements. The standard reduced height waveguide structure with suspended stripline is first analyzed and a model is validated through comparison with scale model and working scale measurements. In the first step, the intrinsic limitations of the standard mixer structure are identified, and the parameters are optimized bearing in mind the radioastronomical applications. In the second step, inductive tuning of the junctions is introduced and optimized for minimum noise and maximum bandwidth. In the 1.3 mm band, a DSB receiver temperature of less than 110 K (minimum 80 K) is measured from 180 through 260 GHz. In the 0.8 mm band, a DSB receiver temperature of less than 250 K (minimum 175 K) is obtained between 325 and 355 GHz. All these results are obtained with room-temperature optics and a 4 GHz IF chain having a 500 MHz bandwidth and a noise temperature of 14 K.

Karpov, A.↗

Superconducting terahertz mixer using a transition-edge microbolometer

We present a new device concept for a mixer element for THz frequencies. This uses a superconducting transition-edge microbridge biased at the center of its superconducting transition near 4.2 K. It is fed from an antenna or waveguide structure. Power from a local oscillator and an RF signal produce a temperature and resulting resistance variation at the difference frequency. The new aspect is the use of a very short bridge in which rapid (less than 0.1 ns) outdiffusion of hot electrons occurs. This gives large intermediate frequency (IF) response. The mixer offers about 4 GHz IF bandwidth, about 80 ohm RF resistive impedance, good match to the IF amplifier, and requires only 1-20 nW of local oscillator power. The upper RF frequency is determined by antenna or waveguide properties. Predicted mixer conversion efficiency is 1/8, and predicted double-sideband receiver noise temperatures are 260 and 90 K for transition widths of 0.1 and 0.5 Tc, respectively.

Prober, D. E.↗