Search NASA⌕ Search

SEARCH · Search NASA

Results for “Monte Carlo N-Particle”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Design of Critical Experiments Targeting Epithermal Cross Sections of Tantalum

Sandia National Laboratories (SNL) and Oak Ridge National Laboratory (ORNL) are collaborating to develop a capability to test the epithermal/intermediate cross sections of tantalum (Ta) at the SNL critical experiments facility using the Seven Percent Critical Experiment (7uPCX) fuel. The Sandia Critical Experiments (SCX) Program provides a specialized facility for performing water moderated and reflected critical experiments with UO 2 fuel rod arrays. A history of safe reactor operations and flexibility in reactor core configuration has resulted in the completion of several benchmark critical experiment evaluations that are published in the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook. The critical experiments described here are scheduled to be performed at SCX in fiscal year 2023. Currently, fabrication details for the needed new equipment are being finalized for completion of the procurement process. The experiments will then be executed and documented for publication consideration by the ICSBEP.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Nuclear data covariances are critical input to determine upper sub-critical limits and to design experiments to increase it [Slides]

This presentation discusses how Upper Subcritical Limits (USL) are key parameters to determine operational limits in nuclear criticality safety evaluations. It also discusses an example of plutonium casting operation using tantalum at LANL PF-4. The Whisper tool at Los Alamos relies on many inputs, including covariance data, leading the presentation to ask if an existing benchmark data be used in Whisper to adjust nuclear data and covariances to justify a higher USL. If not, Whisper can be used to help design an optimal new benchmark experiment. The presentation also seeks to determine what the possible impacts are on USL and operational limits for plutonium casting. In conclusion, nuclear data covariances are used for by Whisper for: GSSL adjustment of nuclear data and covariances, identification of most similar existing benchmark experiments to application, simulation of Upper Subcritical Limit of application, and input to optimization techniques for designing most appropriate new benchmark experiment(s) to meet requirements. This requires a complete set of nuclear data covariances, benchmarks and k-effective sensitivity profiles (for both benchmarks and applications). The presentation concludes by asking if end users should trust results that depend on current covariance data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Coincident Capture through Post-processing PTRAC [Slides]

This presentation discusses the new PTRAC capabilities and workflows. The PTRAC capability in MCNP6.3 has seen a massive overhaul since MCNP6.2. The new HDF5 file format allows for both MPI- and thread-based parallelism. MCNPTools has been updated to handle the new HDF5 PTRAC format and is now open sourced on GitHub. Built-in capabilities, such as the pulse-height tally coincident capture special treatment, can largely be replicated through separate postprocessing scripts that leverage both PTRAC and MCNPTools. This allows for greater flexibility in user-specified and controlled detector response functionality, ultimately using the MCNP code for what it is best at (i.e., particle transport).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

MCNP6.3 Workshop [Slides]

This workshop presentation revisits several new features of MCNP6.2 and tools. Additionally, it offers a preview of the new features and improvements included in the upcoming MCNP6.3 code release that are most relevant to the nuclear radiation protection and shielding communities.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Open-source release of CGMF 1.1 and Integration into the MCNP6.3 ® Code [Slides]

As a result of a multi-year NA-22 project, CGMF was integrated into MCNP6.2 and publicly released. CGMF was open-sourced and publicly released and MCNP6.3 was updated to include the latest version and is in the process of being publicly released. Current and future plans include global optimization and uncertainty quantification within CGMF, model parameter fitting such that CGMF may be used in ENDF/B evaluations, and improving both standalone and MCNP-integrated CGM (non-fission) simulations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Overview of Nuclear Data Measurement and Analysis at RPI [Slides]

This presentation discusses the experimental, simulation, and nuclear data methods that were validated for the RPI γ-Multiplicity Detector. When the neutron capture γ-cascade data is well-known, the γ-emission spectra can be accurately calculated using the modified simulation tools. The RPI γ-Multiplicity Detector system is now ready for analysis and recommendations for isotopes with deficiencies in γ-ray data. The presentation also discusses future work which includes developing a method for analyzing and adjusting nuclear data for 59 Co, 55 Mn and other measured isotopes including 181 Ta. Additionally, future work includes comparing experimental γ-emission spectra with MCNP-6.2/DICEBOX simulations for 238 U and 235 U. In summation, new capture and transmission measurements for 54 Fe will help improve resonance parameter evaluation. Neutron capture gamma cascade spectra and yields were measured in the resolved resonance region and compared to evaluations. In addition, the pulsed neutron die-away method was developed as a tool to provide data for validation of TSLs.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Easy_PERT: a Python tool for writing PERT cards and parsing PERT card results [Slides]

This presentation begins by providing an overview of the PERT card. The PERT card uses differential operator method to compute first- and second-order tally variations due to density, composition, and reaction cross-sections. It is possible to have multiple PERT cards in one MCNP input deck to study tally variations for several sets of nuclides, reactions, and energy ranges. Furthermore, the METHOD option tells MCNP to calculate either the perturbed tally (METHOD=-1, -2, -3) or the change in the unperturbed tally (METHOD=1, 2, 3). In summation, a powerful use-case for the MCNP code PERT card is that it facilitates calculating tally sensitivities to nuclear data. Writing PERT card entries and parsing output MCTAL files is tedious and error prone. however, Easy_PERT makes use of existing tools (Faust and MCNPTools) to handle writing PERT card entries and parsing the output MCTAL files. The PERT card is early in the development process and planned upcoming capabilities include calculating sensitivities and combining MCTAL files from separate runs into one JSON file.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Verification and validation testing and tools: comparison between MCNP code versions and nuclear data libraries [Slides]

This presentation discusses the primary goal of software testing which is to test the code for correctness. It also discusses the results for individual suites and the role of validation and verification also referred to in the presentation as V&V. In summation, the V&V framework enables easy comparison between calculations performed with different code versions and/or nuclear data libraries. This entire framework will be distributed with the upcoming MCNP6.3 release. V&V test suites shown and several that were not (Criticality, LAQGSM, Lockwood) will be distributed in the new framework.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Results and Responses for the 2022 User Forum Survey [Slides]

This presentation discusses the results of a MCNP user survey. Example of questions asked include: "Which MCNP particle types do you typically use?," "What sort of simulations do you run most often?," "Do you build the code?," "Which variance reduction methods do you use?," "Opinions on HDF5," with frequent discussions regarding each question.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

MCNP6.3: A Year in Review [Slides]

This presentation discusses the past year and the many accomplishments of the MCNP6.3 team. It states that the MCNP6.3 release is imminent and that the approved, final documents have been making their way to the website. The code executables and source are already packaged up for distribution and the new installer is being finalized and tested now, for all platforms. The package will be sent to RSICC before the end of October 2022. Additionally, the presentation discusses some things to think about as MCNP6.3 is requested and/or used. For example, many of the recent efforts have been focused on making development, updates, and distribution of the code and documents more robust and streamlined. They will be revising/updating documents more frequently than ever before and they will be exploring avenues to distribute official patches to MCNP6.3. As they explain, this allows them to be more responsive to bugs and issues that are identified. In conclusion, the application of a patch to MCNP6.3 will require having the source code.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Multigroup Cross-section Generation in MCNP6.3 [Slides]

This presentation states that in comparison to the NJOY-produced multigroup cross sections, the MCNP-produced multigroup cross sections are generally consistent. Statistical uncertainties, however, are challenging and the unresolved resonance region may be looked at in the future. It also discusses how the SPM and LCS options were compared to each other for internal consistency. Additionally, some reactor pin-cell-like problems were used to compare to multigroup capabilities in other Monte Carlo codes (e.g., Serpent, OpenMC).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

MCNP6.3 Code and Nuclear Data Installation Guide [Slides]

This presentation discusses the MCNP6.3 release package and examines how it offers more MCNP6-specific executables and options available than ever before. It also discusses the installer and that it streamlines the MCNP6.3 installation and automatically downloads all production nuclear data and generates xsdir files for the user. Additionally, the nd_manager is also discussed regarding how it allows the LANL Nuclear Data and Monte Carlo teams to work and distribute their products independently. It also allows updates, fixes (errata), and newly released data to be made available in a much faster timescale than ever before.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Progress Update on the MUSIC Critical Benchmark

The Measurement of Uranium Subcritical and Critical (MUSiC) experiment was carried out from December 2020 through April 2021 at the National Criticality Experiments Research Center (NCERC). This measurement campaign featured bare configurations of the Rocky Flats highly-enriched uranium (HEU) shells, with each configuration having different numbers of these shells. The goal of the experiment was to test multiple neutron multiplicity detectors and measurement methods for a large range of neutron multiplication values. The large range of multiplications allows researchers to see when the combination of detectors and methods break down as the configurations reach the delayed supercritical window. The critical configurations were the extreme end of the multiplication range in MUSIC configurations. A critical benchmark in the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook is planned to help further validate nuclear data. Even though there are many benchmarks focusing on the fast spectrum for highly-enriched uranium, an additional benchmark that is well documented and up to the modern standard of the handbook would be a welcome addition. Given that there are no other materials such as moderators or significant reflectors, and its similarity to Lady Godiva, it is possible that this could be very useful for validation of 235 U nuclear data in the future.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hybrid Particle Swarm-Interpolation Algorithm for Improved Critical Experiment Design

The typical goal of designing a critical experiment is twofold: a system that is both critical and optimized for some other value. This value could be an energy-integrated sensitivity, percent fissions in a certain energy range, or some other value that can be calculated by a transport code. By simulating different combinations of reflector, moderator, and fuel thicknesses a designer can identify such a desirable configuration. The domain of all possible combinations of these thicknesses is referred to as the experiment search space. As more dimensions are added, the search space increases in size exponentially. For a three-dimensional case, which includes three thickness values between zero and ten centimeters to the nearest tenth of a millimeter, a total of 1,000 3 , configurations exists. Rather than check each configuration individually, which would be extremely computationally expensive, it has been shown to be more efficient to use a conventional particle swarm optimization (PSO) algorithm to identify critical and optimal configurations. This work presents the theory and implementation of a novel hybrid PSO interpolation algorithm to perform these optimizations faster than a conventional PSO algorithm. To demonstrate this, an example optimization will be carried out by the conventional and hybrid PSO algorithms and their performances will be compared.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Why Lady Godiva Should be Replaced as the Default Validation Experiment for U-235 Nuclear Data

For the past seven decades the Lady Godiva benchmark (HEU-MET-FAST-001) has been the primary experiment used for 235 U nuclear data validation. The papers associated with large nuclear data library releases such as ENDF/B-VII.1 and ENDF/B-VIII.0 refer to it frequently. The reasons why HEU-MET-FAST-001 has been used as the primary validation experiment for 235 U nuclear data validation will be discussed in the following section. However, as discussed among the benchmark community, the standards associated with International Criticality Safety Benchmark Evaluation Project (ICSBEP) evaluations have changed throughout time; this is subject of the OECD/NEA WPEC (Working Party on Nuclear Criticality Safety) Subgroup 8. HEU-MET-FAST-001 is an older benchmark (issued during the inaugural year of ICSBEP in 1996 with only minor revisions occurring since then) and (along with many of the other benchmarks from this era) does not meet the standards for a modern benchmark. This work explores why HEU-MET-FAST-001 is useful for 235 U nuclear data validation and discusses other alternative validation experiments.

07 ISOTOPE AND RADIATION SOURCES↗