Search NASA⌕ Search

SEARCH · Search NASA

Results for “Monte Carlo N-Particle (MCNP) Code”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

99 records · Page 6

Investigation of Delayed Neutron Sensitivities for Several ICSBEP Benchmarks using MCNP

The effective delayed neutron (β$_{eff}$) is a very important parameter for reactor and criticality applications. This parameter is equal to the difference in reactivity between delayed critical ($k_{eff}$ = 1, which requires both prompt and delayed neutrons to achieve criticality) and prompt critical ($k_p$ = 1, which requires only prompt neutrons to achieve criticality). This is often referred to as the delayed critical "window" (the region of criticality between delayed and prompt critical). β$_{eff}$ is a reactor kinetics parameters and depends on the nuclides in the system that undergo fission as well as the spectral characteristics of the system. Measurements of β$_{eff}$ have been performed for many criticality experiments. The EUCLID (Experiments Underpinned by Computational Learning for Improvements in nuclear Data) project at Los Alamos National Laboratory (LANL) aims to constrain nuclear data by using a suite of measurement types beyond $k_{eff}$. Our team has recently investigated the use of pulsed spheres for nuclear data validation. Several other measurement methods are also of interest, including β$_{eff}$ (investigated here) and reactivity coefficients (investigated in a separate work at this same meeting). One focus of our work is to determine if other methods are complimentary to the critical experiments already utilized for nuclear data validation. This is important because if a method has similar sensitivities then it will not be particularly useful for nuclear data validation as it will provide the same information as the critical experiments already being used. Here "similar" could refer to several characteristics, one being the shape of a sensitivity profile over energy. In the future, these methods will be utilized (with both existing and new experiments) in machine learning algorithms for nuclear validation, similar to what is currently done for criticality experiments. In order to use a measurement type for nuclear validation, it is necessary to obtain cross-section sensitivities for that parameter. This work looks at one approach to estimate β$_{eff}$ sensitivities by utilizing $k_{eff}$ sensitivities within Monte Carlo N-Particle ® Code Version 6.2. This is applied to several criticality benchmarks. Results are compared and the benefits and limitations of this approach are discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Verifying MCNP Models of the TEX High 240 Plutonium Benchmark

Computational modeling programs are invaluable tools that allow us to understand systems, safely develop new processes, and make reliable predictions about future designs. However, the effectiveness of these codes is limited by the degree to which their parameters match the real world. In the field of nuclear engineering, cross section data is one of these vital parameters. Accurate cross section data on important fissile and fissionable isotopes promotes the design of safer and more efficient fabrication, transportation, storage, and stockpiling of nuclear fuel. Unfortunately, there are knowledge gaps in data on key isotopes. In 2011, a multinational meeting hosted by the US Department of Energy Nuclear Criticality Safety Program ranked the priority of certain cross section data needs. In response, Lawrence Livermore National Lab (LLNL) designed the Thermal and Epithermal eXperiment (TEX) series of benchmark experiments. Benchmark experiments are used to validate current cross section data. They validate data by comparing the results of an actual experiment to the predicted results from a computational model. The data a benchmark applies to depends on the isotope and energy range the experiment’s neutron multiplication factor ( k eff ) is most sensitive to. The development and testing of the TEX High 240 Plutonium Benchmark will help validate 240 Pu cross section data. The configuration and materials of this benchmark are designed to be most sensitive to 240 Pu's intermediate energy range (from 0.625 ev to 100 keV ). MCNP® models of the assembly have been developed by LLNL and the results have been written in the final design report. In order for the discrepancies between benchmark models and experiments to be attributed to cross section inaccuracies, the accuracy of the models needs to be verified. The goal of this project is to verify of the results of LLNL's modeling by creating a new set of MCNP models and comparing the results.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Uniformly Ordered Binary Decision Algorithm for Benchmark Experiment Correlations in Whisper Validation

When performing a validation exercise for determining the upper subcritical limit of a nuclear criticality safety application, an analyst should select and perform a statistical analysis on a population of benchmark experiments that are neutronically similar to the application. The size of this population should be sufficiently large such that the statistical analysis has a high degree of confidence that the bias plus bias uncertainty (calculational margin) has been accurately quantified. A complication arises because many benchmark experiments share common components, leading to correlations in their measured effective multiplication factors. Correlations between benchmark experiments within the population reduces its predictive power. This motivates the need for methods that consider benchmark experiment correlations and ensure adequate statistical significance of results. The Whisper code is a statistical analysis pack- age that incorporates nuclear data sensitivity coefficients from MCNP to assess benchmark experiment similarity and then performs an extreme-value analysis to estimate the bias plus bias uncertainty. The original methodology in Whisper does not consider the effect of benchmark experiment correlations when making this estimation, and this summary proposes the uniformly ordered binary decision algorithm to address this shortcoming. The original methodology in Whisper computes similarity coefficients ck for an application compared to all benchmark experiments in its library and develops weighting factors for a selected population proportional to the ck values. The methodology can be interpreted as statistically emulating a validation exercise for a particular application where the weighting factors may be viewed as the likelihood that an analyst would include a particular benchmark experiment within the population. The effective sample size of the population is the expected or mean number of benchmark experiments in the population. The uniformly ordered binary decision algorithm identifies clusters of correlated benchmark experiments within the population and then computes adjusted weighting factors based on the magnitude of the correlation coefficients within the cluster to compute a reduced effective sample size accounting for the lower information content because of correlations. Benchmark experiments within the cluster are ordered randomly with equal probability and probabilistic decisions are made as to whether a benchmark. experiment within the cluster should treated as redundant with a previous one; if two redundant benchmark experiments are included, then the conservative worst case bias plus bias uncertainty is used and the pair is counted as a single benchmark experiment in the population. Results are provided for HEU solutions in a research version of the Whisper software using benchmark experiment correlations provided by DICE, the Database for the International Criticality Safety Benchmark Evaluation Project (ICSBEP). These show that there can be a significant increase in the bias plus bias uncertainty because the effective sample size is reduced, and therefore the algorithm, needing to meet sample size requirements, expands the benchmark experiment population by accepting less similar benchmark experiments that would have otherwise not been included.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Coincident Capture through Post-processing PTRAC [Slides]

This presentation discusses the new PTRAC capabilities and workflows. The PTRAC capability in MCNP6.3 has seen a massive overhaul since MCNP6.2. The new HDF5 file format allows for both MPI- and thread-based parallelism. MCNPTools has been updated to handle the new HDF5 PTRAC format and is now open sourced on GitHub. Built-in capabilities, such as the pulse-height tally coincident capture special treatment, can largely be replicated through separate postprocessing scripts that leverage both PTRAC and MCNPTools. This allows for greater flexibility in user-specified and controlled detector response functionality, ultimately using the MCNP code for what it is best at (i.e., particle transport).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

MCNP ® Particle Transport Code: Its History and Future [Slides]

The history, development and application uses of Monte Carlo particle transport codes at LANL are extensive. Recent and ongoing investments in MCNP modernization are enabling new code developments using modern programming tools and languages. New and challenging applications continue to drive new research and developments beyond the rich set of established MCNP capabilities. The LANL MCNP radiation transport code has been the international gold standard for particle transport applications for over three decades.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Second Target Station High-Fidelity Target Activation Comparison

The development of the Second Target Station (STS) target system at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL) is well underway. The target system at STS consists of a rotating target disk that contains 21 segments of tungsten clad in tantalum clad in steel. A key aspect of the design of the target system is to account for the delayed heating and material damage caused by the delayed dose from decaying radionuclides. These radionuclides are a product of either spallation reactions or transmutation of the nuclei in the target system. These radionuclides build up in the target system components over the lifetime of the facility, and the radiation that is emitted can deposit energy in the components causing significant component heating and material damage. Monte Carlo N-Particle (MCNP) Version 6.2 transports the various particle species and calculates the spallation products and neutron fluxes throughout the target system. These spallation products and neutron fluxes along with the material definition of each component are relayed to the CINDER2008 transmutation code to calculate the radionuclide inventories and the corresponding decay gamma emission spectra. MCNP6.2 coupled with CINDER2008 is the computational method-of-choice for the analysis discussed in the following sections of this report. The analysis focuses on validating major assumptions in calculating the radionuclide inventory in the STS target system: all of the target segments are fresh, unirradiated material when the protons are incident on the segment, the average of the 21 segments of the target is sufficient to represent a single segment, and that averaging the proton pulse structure over time does not significantly affect the radionuclide inventory. The position-averaged, high-fidelity, and single-tally computational methods are used to validate the assumptions and provide a point of comparison to evaluate how the assumptions impact the radionuclide inventories. A more detailed explanation of the three computational methods is provided in Section 2. The position-averaged and single-tally methods are less computationally expensive when compared with the high-fidelity method where 54,000 individual calculations are needed to calculate 1 hr of STS operation. Section 3 details the comparison of the three methods to show that the assumptions made in the position-averaged method do not significantly impact the radionuclide inventory after 1 hr of operation. The discussions and results in this report are for 1 hr of operation. Due to the computational cost associated with calculating the transmutation and activation using the high-fidelity method, only 1 hr of operation has been calculated. The discrepancies observed after 1 hr of operation are not extrapolated out to longer operational times, and this report does not address how the discrepancies between the computational methods may manifest for longer operational periods.

43 PARTICLE ACCELERATORS↗

Parallel Programming in MCNP6

Monte Carlo N-Particle (MCNP)1 is a general-purpose Monte Carlo particle transport code developed by Los Alamos National Laboratory (LANL). To efficiently handle long simulations, MCNP version 6 (MCNP6) supports parallel execution using two primary programming models: • Shared-memory task-based threading using OpenMP (Open Multi-Processing), and • Distributed-memory calculations using MPI (Message Passing Interface). The OpenMP and MPI programming models enable MCNP6 to scale from desktop systems to high-performance computing (HPC) clusters, allowing users to run MCNP in one of three parallel modes: • OpenMP-only, • MPI-only, and • Hybrid (MPI + OpenMP). The choice of parallelization mode depends on the underlying computer architecture and the characteristics of the simulation problem.

97 MATHEMATICS AND COMPUTING↗

Hybrid Particle Swarm-Interpolation Algorithm for Improved Critical Experiment Design

The typical goal of designing a critical experiment is twofold: a system that is both critical and optimized for some other value. This value could be an energy-integrated sensitivity, percent fissions in a certain energy range, or some other value that can be calculated by a transport code. By simulating different combinations of reflector, moderator, and fuel thicknesses a designer can identify such a desirable configuration. The domain of all possible combinations of these thicknesses is referred to as the experiment search space. As more dimensions are added, the search space increases in size exponentially. For a three-dimensional case, which includes three thickness values between zero and ten centimeters to the nearest tenth of a millimeter, a total of 1,000 3 , configurations exists. Rather than check each configuration individually, which would be extremely computationally expensive, it has been shown to be more efficient to use a conventional particle swarm optimization (PSO) algorithm to identify critical and optimal configurations. This work presents the theory and implementation of a novel hybrid PSO interpolation algorithm to perform these optimizations faster than a conventional PSO algorithm. To demonstrate this, an example optimization will be carried out by the conventional and hybrid PSO algorithms and their performances will be compared.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Photoneutron Production Using an Electron Linear Accelerator for Applications in Neutron Imaging

Photoneutron production is possible using an electron linear accelerator and a target capable of generating photonuclear reactions. A short pulse neutron source can be useful for neutron imaging dynamic experiments. This study is aimed at the feasibility of photoneutron production using a 20 MeV electron linear accelerator and tungsten and depleted uranium targets of various thicknesses. MCNP6 (Monte Carlo N-Particle) code will be used to develop a computational model to estimate total neutron yield, and this will be verified at the Idaho State University’s Accelerator Center. After verification of the neutron yield and energy spectra, an additional MCNP6 model will be developed to analyze the neutron imaging processes. This study will potentially prove it is possible to conduct multi-mode imaging experiments on the anticipated Scorpius electron linear accelerator at the Nevada National Security Sites.

43 PARTICLE ACCELERATORS↗