Search NASA⌕ Search

SEARCH · Search NASA

Results for “Motion Segmentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Deep Learning and Photogrammetric Reconstruction for Automated Crack Detection and Dimensional Measurement in Mining Operations

Surface crack detection and dimensional measurement at active mining sites present significant safety and operational challenges. Manual inspection methods are labor-intensive, spatially incomplete, and expose personnel to hazardous environments, while existing automated approaches have been developed primarily for concrete civil infrastructure and have not been validated on the complex, variable surfaces characteristic of mining environments. This dissertation presents an automated pipeline that integrates deep learning semantic segmentation with Structure-from-Motion photogrammetry to detect surface cracks and measure their aperture, length, and vertical displacement from standard RGB imagery acquired during routine Uncrewed Aerial Vehicle (UAV) survey operations, without requiring additional sensor hardware or manual measurement. The pipeline combines a U-Net architecture with an EfficientNet-B0 encoder, pretrained on the SDNET2018 concrete crack dataset and fine-tuned on a mining-specific dataset spanning laboratory concrete specimens, coal refuse impoundment embankments, and post-blast limestone quarry benches. Photogrammetric reconstruction is performed using COLMAP Structure-from-Motion and Multi-View Stereo, with crack segmentation masks projected into the reconstructed point cloud to enable three-dimensional vertical displacement measurement through local plane fitting and bimodal surface detection. The pipeline was validated across 36 controlled laboratory specimens at three imaging distances and four vertical displacement levels, achieving aperture measurement RMSE of 0.047 cm and R² of 0.954, and vertical displacement RMSE of 0.140 cm and R² of 0.966, against independent caliper measurements. Field application at a coal refuse impoundment in southwestern Pennsylvania detected 71 crack components across the embankment crest, with a dominant longitudinal crack exhibiting aperture values reaching 28 cm and a 95th percentile vertical displacement of 35.53 cm, consistent in magnitude and spatial distribution with simultaneously acquired LiDAR-derived estimates. Application across four post-blast limestone quarry bench datasets in California successfully characterized blast-induced fracture networks at ground sampling distances ranging from 0.59 to 1.23 cm/pixel, with detected crack geometries physically consistent with observable surface conditions at each site. The results demonstrate that deep learning-based crack detection and photogrammetric measurement can be integrated into routine UAV inspection workflows at mining sites, providing repeatable, scalable, and quantitative crack characterization across surface types, crack scales, and displacement magnitudes not previously addressed in the literature. The pipeline requires no dedicated surveying equipment beyond the UAV platforms already deployed at mine sites for survey and monitoring purposes, supporting practical adoption within existing operational workflows.

Crack detection, Dimensional Measurement↗

Foldable beam

Articulated beam folds into helix around cylindrical hub without segments becoming twisted. Twisting motion that normally occurs when a structure is folded into helix is undesirable in segmented beam because it complicates joints between segments.

Crawford, R. F.↗

Quantifying the interplay effect in prostate IMRT delivery using a convolution-based method

The authors present a segment-based convolution method to account for the interplay effect between intrafraction organ motion and the multileaf collimator position for each particular segment in intensity modulated radiation therapy (IMRT) delivered in a step-and-shoot manner. In this method, the static dose distribution attributed to each segment is convolved with the probability density function (PDF) of motion during delivery of the segment, whereas in the conventional convolution method (''average-based convolution''), the static dose distribution is convolved with the PDF averaged over an entire fraction, an entire treatment course, or even an entire patient population. In the case of IMRT delivered in a step-and-shoot manner, the average-based convolution method assumes that in each segment the target volume experiences the same motion pattern (PDF) as that of population. In the segment-based convolution method, the dose during each segment is calculated by convolving the static dose with the motion PDF specific to that segment, allowing both intrafraction motion and the interplay effect to be accounted for in the dose calculation. Intrafraction prostate motion data from a population of 35 patients tracked using the Calypso system (Calypso Medical Technologies, Inc., Seattle, WA) was used to generate motion PDFs. These were then convolved with dose distributions from clinical prostate IMRT plans. For a single segment with a small number of monitor units, the interplay effect introduced errors of up to 25.9% in the mean CTV dose compared against the planned dose evaluated by using the PDF of the entire fraction. In contrast, the interplay effect reduced the minimum CTV dose by 4.4%, and the CTV generalized equivalent uniform dose by 1.3%, in single fraction plans. For entire treatment courses delivered in either a hypofractionated (five fractions) or conventional (>30 fractions) regimen, the discrepancy in total dose due to interplay effect was negligible.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Acute Cardiac Impairment Associated With Concurrent Chemoradiotherapy for Esophageal Cancer: Magnetic Resonance Evaluation

Purpose: To evaluate acute cardiac effects of concurrent chemoradiotherapy (CCRT) for esophageal cancer. Methods and Materials: This prospective study was approved by the institutional review board, and written informed consent was obtained from all participants. The left ventricular function (LVF) of 31 patients with esophageal cancer who received cisplatin and 5-fluorouracil-based CCRT was evaluated using cardiac cine magnetic resonance imaging. The patients were classified into two groups according to mean LV dose. The parameters related to LVF were compared between before and during (40 Gy) or between before and after CCRT using a Wilcoxon matched-pairs single rank test, and parameter ratios (during/before CCRT, after/before CCRT) were also compared between the groups with a t test. Data were expressed as mean {+-} SE. Results: In the low LV-dose group (n = 10; mean LV dose <0.6 Gy), LV ejection fraction decreased significantly (before vs. during vs. after CCRT; 62.7% {+-} 2.98% vs. 59.8% {+-} 2.56% vs. 60.6% {+-} 3.89%; p < 0.05). In the high LV-dose group (n = 21; mean LV dose of 3.6-41.2 Gy), LV end-diastolic volume index (before vs. after CCRT; 69.1 {+-} 2.93 vs. 57.0 {+-} 3.23 mL/m{sup 2}), LV stroke volume index (38.6 {+-} 1.56 vs. 29.9 {+-} 1.60 mL/m{sup 2}), and LV ejection fraction (56.9% {+-} 1.79% vs. 52.8% {+-} 1.15%) decreased significantly (p < 0.05) after CCRT. Heart rate increased significantly (before vs. during vs. after CCRT; 66.8 {+-} 3.05 vs. 72.4 {+-} 4.04 vs. 85.4 {+-} 3.75 beats per minute, p < 0.01). Left ventricle wall motion decreased significantly (p < 0.05) in segments 8 (before vs. during vs. after CCRT; 6.64 {+-} 0.54 vs. 4.78 {+-} 0.43 vs. 4.79 {+-} 0.50 mm), 9 (6.88 {+-} 0.45 vs. 5.04 {+-} 0.38 vs. 5.27 {+-} 0.47 mm), and 10 (9.22 {+-} 0.48 vs. 8.08 {+-} 0.34 vs. 8.19 {+-} 0.56 mm). The parameter ratios of LV end-diastolic volume index, stroke volume index, wall motion in segment 9, and heart rate showed significant difference (p < 0.05) after CCRT between the groups. Conclusions: Concurrent chemoradiotherapy for esophageal cancer impairs LVF from an early treatment stage. This impairment is prominent in patients with high LV dose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A rebound shock mechanism for solar fibrils

Flows along a rigid solar magnetic flux tube which is horizontal over a substantial portion of its length are numerically investigated. A single, quasi-impulsive force near the base of the first vertical segment drives a series of upward propagating rebound shocks on the flux tube. When the horizontal segment is in the corona, the shocks raise the transition region onto the horizontal segment and eventually onto the coronal vertical segment. The material behind the displaced transition region resembles a fibril on the horizontal segment, and a short spicule on the second vertical segment. A full-sized spicule does not develop. The resulting density of the material on the horizontal segment is 10 to the -14th g/cu cm, which is consistent with the observed densities in fibrils. When the horizontal segment is in the chromosphere, the motions and densities induced on the horizontal segment do not resemble those of observed fibrils, and a full-sized spicule again does not develop.

Sterling, Alphonse C.↗

Laser Truss Sensor for Segmented Telescope Phasing

A paper describes the laser truss sensor (LTS) for detecting piston motion between two adjacent telescope segment edges. LTS is formed by two point-to-point laser metrology gauges in a crossed geometry. A high-resolution (<30 nm) LTS can be implemented with existing laser metrology gauges. The distance change between the reference plane and the target plane is measured as a function of the phase change between the reference and target beams. To ease the bandwidth requirements for phase detection electronics (or phase meter), homodyne or heterodyne detection techniques have been used. The phase of the target beam also changes with the refractive index of air, which changes with the air pressure, temperature, and humidity. This error can be minimized by enclosing the metrology beams in baffles. For longer-term (weeks) tracking at the micron level accuracy, the same gauge can be operated in the absolute metrology mode with an accuracy of microns; to implement absolute metrology, two laser frequencies will be used on the same gauge. Absolute metrology using heterodyne laser gauges is a demonstrated technology. Complexity of laser source fiber distribution can be optimized using the range-gated metrology (RGM) approach.

Liu, Duncan T.↗

Time-Varying Manual Control Identification in a Stall Recovery Task Under Different Simulator Motion Conditions

This paper adds data to help the development of simulator motion cueing guidelines for stall recovery training by identifying time-varying manual control behavior in a stall recovery task under different simulator motion conditions. A study was conducted with seventeen general aviation pilots in the NASA Ames Vertical Motion Simulator. Pilots had to follow a flight director through four stages of a high-altitude stall task. A time-varying identification method was used to quantify how pilot manual control parameters change throughout different stages of the task in both roll and pitch. Four motion configurations were used: no motion, generic hexapod motion, enhanced hexapod motion and full motion. Pilot performance was highest for the enhanced hexapod and full motion configurations in both roll and pitch, and the lowest without motion. In the roll axis, the pilot position gain did not significantly change throughout the stall task, but was the lowest for the condition with no motion. The pilot roll velocity gain was significantly different between motion conditions, the largest difference being found close to the stall point. The enhanced hexapod motion condition had the highest pilot roll velocity gain. In the pitch axis, the pilot position gain was significantly different between time segments but not between motion conditions. The pilot pitch velocity gain was highest for the full motion condition and increased close to the stall point, but did not change significantly for the other motion conditions. Overall, pilot control behavior under enhanced hexapod motion was most similar to that under full aircraft motion. This indicates that motion cueing for stall recovery training on hexapod simulators might be improved by using the principles behind the enhanced hexapod motion configuration.

manual control↗

Smooth Pursuit of a Partially Occluded Object

There has long been qualitative evidence that humans can pursue an object defined only by the motion of its parts. We explored this quantitatively using an occluded diamond stimulus. Four subjects (one naive) tracked a line-figure diamond moving along an elliptical path (0.9 Hz) either clockwise (CW) or counterclockwise (CCW) behind either an X-shaped aperture (CROSS) or two vertical rectangular apertures (BARS), which obscured the corners. Although the stimulus consisted of only four line segments (108 cd/square m) moving within a visible aperture (0.2 cd/square m) behind a foreground (38 cd/square m), it is largely perceived as a coherently moving diamond. The inter-saccadic portions of eye-position traces were fit with sinusoids. All subjects tracked object motion with considerable temporal accuracy. The mean phase lag was 5 deg/6 deg (CROSS/BARS) and the mean relative phase between the horizontal and vertical components was +95 deg/+92 deg (CW) and -85 deg/-75 deg (CCW), which is close to perfect. Furthermore, a chi-square analysis showed that 56% of BARS trials were consistent with tracking the correct elliptical shape (p is less than 0.05), although segment motion was purely vertical. These data disprove the main tenet of most models of pursuit: that it is a system that seeks to minimize retinal image motion through negative feedback. Rather, the main drive must be a visual signal which has already integrated spatiotemporal retinal information into an object-motion signal.

Stone, L. S.↗

Minimization of Retinal Slip Cannot Explain Human Smooth-Pursuit Eye Movements

Existing models assume that pursuit attempts a direct minimization of retinal image motion or "slip" (e.g. Robinson et al., 1986; Krauzlis & Weisberger, 1989). Using occluded line-figure stimuli, we have previously shown that humans can accurately pursue stimuli for which perfect tracking does not zero retinal slip (Neurologic ARCO). These findings are inconsistent with the standard control strategy of matching eye motion to a target-motion signal reconstructed by adding retinal slip and eye motion, but consistent with a visual front-end which estimates target motion via a global spatio-temporal integration for pursuit and perception. Another possible explanation is that pursuit simply attempts to minimize slip perpendicular to the segments (and neglects parallel "sliding" motion). To resolve this, 4 observers (3 naive) were asked to pursue the center of 2 types of stimuli with identical velocity-space descriptions and matched motion energy. The line-figure "diamond" stimulus was viewed through 2 invisible 3 deg-wide vertical apertures (38 cd/m2 equal to background) such that only the sinusoidal motion of 4 oblique line segments (44 cd/m2 was visible. The "cross" was identical except that the segments exchanged positions. Two trajectories (8's and infinity's) with 4 possible initial directions were randomly interleaved (1.25 cycles, 2.5s period, Ax = Ay = 1.4 deg). In 91% of trials, the diamond appeared rigid. Correspondingly, pursuit was vigorous (mean Again: 0.74) with a V/H aspect ratio approx. 1 (mean: 0.9). Despite a valid rigid solution, the cross however appeared rigid in 8% of trials. Correspondingly, pursuit was weaker (mean Hgain: 0.38) with an incorrect aspect ratio (mean: 1.5). If pursuit were just minimizing perpendicular slip, performance would be the same in both conditions.

Stone, Leland S.↗

A Moving Grid Capability for NPARC

Version 3.1 of the NPARC computational fluid dynamics flow solver introduces a capability to solve unsteady flow on moving multi-block, structured grids with nominally second-order time accuracy. The grid motion is due to segments of the boundary grid that translate and rotate in a rigid-body manner or deform. The grid is regenerated at each time step to accommodate the boundary grid motion. The flow equations and computational models sense the moving grid through the grid velocities, which are computed from a time-difference of the grids at two consecutive time levels. For three-dimensional flow domains, it is assumed that the grid retains a planar character with respect to one coordinate. The application and accuracy of NPARC v3.1 is demonstrated for flow about a flying wedge, rotating flap, a collapsing bump in a duct, and the upstart / restart flow in a variable-geometry inlet. The results compare well with analytic and experimental results.

Slater, John W.↗

Coherent phasing of segmented mirrors

The technical issues associated with a coherently phased segmented mirror can be divided into two types. The first involves the issues of manufacturing the surface quality of the mirror segments themselves (coherent phasing of individual segments). The second involves assembly issues of initializing in 1 G and retaining in 0 G an aggregate segmented mirror (coherent phasing between individual segments). Using a rectangular coordinate system at the vertex of a mirror segment, the rigid body motions are the six translational and rotational degrees of freedom. A first cut primary mirror wavefront error budget is presented. For a minimum operational wavelength of 30 micrometers, the derived values from the budget are: segment surface quality (0.45 micrometers RMS), radius mismatch (50 PPM), segment piston error (1.3 micrometers, segment tip/tilt error (0.6 microrad). Either active or passive segmented mirrors can be addressed, but if the surface quality of the off-axis segment and the radius matching requirements can be passively met, then only segment alignment need be sensed and controlled during operation in orbit. For the active mirror case, dimensional stability of the mirror material during operation is a key factor in establishing the degree of active figure control required.

Jones, Peter A.↗

From following edges to pursuing objects

Primates can generate accurate, smooth eye-movement responses to moving target objects of arbitrary shape and size, even in the presence of complex backgrounds and/or the extraneous motion of non-target objects. Most previous studies of pursuit have simply used a spot moving over a featureless background as the target and have thus neglected critical issues associated with the general problem of recovering object motion. Visual psychophysicists and theoreticians have shown that, for arbitrary objects with multiple features at multiple orientations, object-motion estimation for perception is a complex, multi-staged, time-consuming process. To examine the temporal evolution of the motion signal driving pursuit, we recorded the tracking eye movements of human observers to moving line-figure diamonds. We found that pursuit is initially biased in the direction of the vector average of the motions of the diamond's line segments and gradually converges to the true object-motion direction with a time constant of approximately 90 ms. Furthermore, transient blanking of the target during steady-state pursuit induces a decrease in tracking speed, which, unlike pursuit initiation, is subsequently corrected without an initial direction bias. These results are inconsistent with current models in which pursuit is driven by retinal-slip error correction. They demonstrate that pursuit models must be revised to include a more complete visual afferent pathway, which computes, and to some extent latches on to, an accurate estimate of object direction over the first hundred milliseconds or so of motion.

NASA Discipline Neuroscience↗

Early risk stratification using Rubidium-82 positron emission tomography in STEMI patients

Background: Assessment of infarct size after myocardial infarction is predictive of subsequent morphological changes and clinical outcome. This study aimed to assess subacute post-intervention Rubidium-82 ({sup 82}Rb)-PET imaging in predicting left ventricle ejection fraction, regional wall motion, and final infarct size by CMR at 3-months after STEMI. Methods: STEMI patients undergoing percutaneous coronary intervention were included prospectively. Rest-only {sup 82}Rb-PET perfusion imaging was performed at median 36 hours [IQR: 22 to 50] after the treatment. The extent of hypoperfusion and absolute blood flow (mL·min·g) were estimated on a global and a 17-segment model with dedicated software. At 3-months follow-up patients completed the CMR functional and late gadolinium enhancement imaging. Results: 42 patients were included, but only 35 had follow-up CMR and constituted the study population. Absolute blood flow was significantly lower in the infarct-related territory compared to remote myocardium, P < .005. Extent of hypoperfusion correlated with final infarct size, r = 0.58, P < .001, while blood flow correlated with ejection fraction, r = 0.41, P < .05. In linear mixed models, higher subacute absolute blood flow (β = 4.6, confidence interval [3.5; 5.2], P < .001, R{sup 2} = 0.67) was associated with greater wall motion. Segmental extent of subacute hypoperfusion (β = 0.43 [0.38; 0.49], P < .001, R{sup 2} = 0.58) was associated with the degree of late gadolinium enhancement at 3-months. Conclusions: Subacute rest-only {sup 82}Rb-PET is feasible following STEMI and seems predictive of myocardial function and infarct size at 3-months.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Rapid Maturation of Edge Sensor Technology and Potential Application in Large Space Telescopes with Segmented Primary Mirrors

This paper explores the history and results of the last two year's efforts to transition inductive edge sensor technology from Technology Readiness Level 2 to Technology Readiness Level 6. Both technical and programmatic challenges were overcome in the design, fabrication, test, and installation of over a thousand sensors making up the Segment Alignment Maintenance System (SAMs) for the 91 segment, 9.2-meter. Hobby Eberly Telescope (HET). The integration of these sensors with the control system will be discussed along with serendipitous leverage they provided for both initialization alignment and operational maintenance. The experience gained important insights into the fundamental motion mechanics of large segmented mirrors, the relative importance of the variance sources of misalignment errors, the efficient conduct of a program to mature the technology to the higher levels. Unanticipated factors required the team to develop new implementation strategies for the edge sensor information which enabled major segmented mirror controller design simplifications. The resulting increase in the science efficiency of HET will be shown. Finally, the on-going effort to complete the maturation of inductive edge sensor by delivering space qualified versions for future IR (infrared radiation) space telescopes.

Montgomery, Edward E., IV↗

Variations in the modal characteristics of a telescopically deploying beam

The equations of motion for a two-segment deploying telescopic beam are derived through application of Lagrange's equation. The outer tube of the beam is fixed at one end and the inner tube slides freely relative to the fixed segment. The resulting nonlinear, non-autonomous set of equations is linearized and simplified to the standard Euler-Bernoulli partial differential equations for an elastic beam by freezing the deployment process at various stages of deployment, and examining the small amplitude and natural modes of vibration of the resulting configuration. Application of the natural boundary conditions and compatibility of motion relations for the two segments in their common region of overlap leads to a transcendental characteristic equation in the frequency parameter Beta(L). Numerical solution of the equation for the characteristic roots determines the modal frequencies, and the corresponding mode shapes are obtained from the general solution of the Euler-Bernoulli equation tailored to the natural boundary conditions. Sample results of modal frequencies and shapes are presented for various stages of deployment and discussed. It is shown that for all intermediate stages of deployment (between 0 and 100 percent) the spectral distribution is drastically altered by the appearance of regions of very closely spaced modal frequencies. The sources of this modal agglomeration are explored.

Amos, Anthony K.↗

Dosimetric investigation of high dose rate, gated IMRT

Increasing the dose rate offers time saving for IMRT delivery but the dosimetric accuracy is a concern, especially in the case of treating a moving target. The objective of this work is to determine the effect of dose rate associated with organ motion and gated treatment using step-and-shoot IMRT delivery. Both measurements and analytical simulation on clinical plans are performed to study the dosimetric differences between high dose rate and low dose rate gated IMRT step-and-shoot delivery. Various sites of IMRT plans for liver, lung, pancreas, and breast cancers were delivered to a custom-made motorized phantom, which simulated sinusoidal movement. Repeated measurements were taken for gated and nongated delivery with different gating settings and three dose rates, 100, 500, and 1000 MU/min using ion chambers and extended dose range films. For the study of the residual motion effect for individual segment dose and composite dose of IMRT plans, our measurements with 30%-60% phase gating and without gating for various dose rates were compared. A small but clinically acceptable difference in delivered dose was observed between 1000, 500, and 100 MU/min at 30%-60% phase gating. A simulation is presented, which can be used for predicting dose profiles for patient cases in the presence of motion and gating to confirm that IMRT step-and-shoot delivery with gating for 1000 MU/min are not much different from 500 MU/min. Based on the authors sample plan analyses, our preliminary results suggest that using 1000 MU/Min dose rate is dosimetrically accurate and efficient for IMRT treatment delivery with gating. Nonetheless, for the concern of patient care and safety, a patient specific QA should be performed as usual for IMRT plans for high dose rate deliveries.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Considerations in Range of Motion Testing for Characterizing Spacesuit Mobility Capabilities

Mobility is a critical aspect for spacesuits as it directly influences how astronauts can perform tasks safely and efficiently, while wearing the pressurized suit. Spacesuit motion is dissimilar to human movement and consists of unique movement patterns as result of pressurization and the complex mechanical joint configurations. Thus, it is important to quantify the variations in suited movement patterns and the resulting performance of the wearer for the evaluation of the spacesuit itself and hardware interfaces such as payloads and tools. Traditionally, an individual body joint is assessed for the segment-wise range of motion. For example, the knee is measured through an isolated maneuvering of the joint between the max-to-max positions (e.g., flexion/extension), and the outcome represents the mobility capabilities. These measurements are often conducted using optical motion capture system with respect to anatomical planes. However, there are several considerations for range of motion assessments that are unique to the spacesuit. The purpose of this paper is to describe and provide examples of these additional challenges in representing spacesuit mobility capabilities. Specifically, joint mobility and the variations in suit movement patterns were investigated and compared between functional tasks and isolated range of motion measurements. Motion capture data from the next-gen spacesuit design verification testing was evaluated to compare isolated range of motion tasks to functional tasks, such as one-knee kneeling and squatting. The trajectories from the upper and lower body joint centers with respect to the spacesuit hardware were also calculated. Additionally, the joint trajectories for various functional tasks are presented and compared against the isolated range of motion measurements. In general, range of motion differs between isolated and functional tasks, where functional tasks may even induce greater joint angle excursions. Additionally, there is a large variation in joint range of motion across functional tasks. Combined with several relevant factors (spacesuit fit, physical strength, simulation facility, etc.), spacesuit mobility characterization efforts will need to incorporate the specific contexts, such as task demands and movement mechanisms, when evaluating range of motion assessments.

Linh Q Vu↗