Search NASA⌕ Search

SEARCH · Search NASA

Results for “NANOSECOND”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Sources of Primary Electrons in Nanosecond Pulsed Breakdown in Water (Final Technical Report)

Electrical breakdown of liquid dielectrics under ns or sub-ns pulsed electric field has been studied extensively in the last decade. Summarized in [7], this relatively young research area makes significant contributions to the theories of liquid breakdown by introducing a new mechanism (electrostrictive cavitation) that is unique at the ns timescale. It is also fundamentally important to plasma sources for biomedical applications and insulation of pulsed power equipment. For water in particular, the understanding of the mechanisms and processes of ns/sub-ns breakdown also sheds new light on cavitation studies, one of the most exciting areas of modern fluid mechanics. The objective of this collaborative research with PCRF was to construct a complete picture of the physical mechanisms and processes at the initial phase of electrical breakdown in liquid dielectrics under nanosecond (ns) pulsed inhomogeneous fields. The research funded by the initial award DE‐ SC0021182 aimed to address the sources of primary electrons in ns breakdown in water, which led to one journal publication and multiple conference presentations. The PI also gave presentations to the PPPL/PCRF audience twice, one in October 2020 and the other during the 2021 PCRF Annual Meeting

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nanosecond Laser Drying in Wafer Foundries for Significant Energy Efficiency Improvement

Surface drying is a critical process in microelectronics wafer fabrication. In order to reduce and eliminate watermarks, many surface drying processes have been studied and used. Most of the wafer foundries currently use drying processes based on Isopropyl Alcohol (IPA), which causes serious safety (fire), health, environmental, and energy efficiency issues. The long-term goal of this project is to develop a fast, effective, chemical-free, and extremely energy efficient wafer drying technology that employs nanosecond laser-induced sub-surface evaporation and explosion. The objectives of this project are to 1) experimentally develop and verify the laser surface drying method, explore and identify how and to what extent various physical parameters influence the drying efficiency and effectiveness; and 2) understand and optimize the underlying thermodynamics in the proposed laser surface drying, including micro/nanoscale sub-surface superheating, evaporation, explosion, and photo/thermochemical bond breaking via atomistic modeling and experimental characterization. Toward these objectives, five tasks have been accomplished successfully, including 1) develop in-lab laser surface drying setup and study the effect of varied laser parameters, 2) use multiscale hybrid-modeling to study and understand the physics of water behavior during drying toward process optimization, 3) investigate the effect of drying conditions on the drying effectiveness, 4) develop a large-scale laser drying scanning system with automatic scanning, and 5) conduct large-scale simulation to study the effect of dopant level and develop strategies for system development toward industry deployment.

42 ENGINEERING↗

Design and validation of a nanosecond short-wave infrared streak camera using gaseous detonation experiments

A custom short-wave infrared (SWIR) galvanometric streak camera was developed to provide nanosecond- scale, time-resolved optical diagnostics. The system was designed as a compact, mechanically driven alternative to traditional tube-based streak cameras, using a galvanometer mirror and multiple-reflection optical path to achieve high temporal resolution while maintaining electronic synchronization for trigger sequencing. Temporal resolution achieved 139.5 ns/px, allowing direct conversion of image-slope gradients to physical wave velocities. The instrument was validated using hydrogen-oxygen-argon detonations within a modular detonation tube, capturing transient emission structures and post-detonation decay behavior with microsecond precision. Although signal levels in filtered configurations were limited by lens transmission and detector sensitivity, the system successfully resolved intensity rise and decay characteristics across 10-60 % argon mixtures. The observed trends demonstrate the feasibility of compact galvanometer-based streak systems for high-speed SWIR imaging in reactive environments!

42 ENGINEERING↗

Towards a Counting Point Detector for Nanosecond Coherent X-ray Science

We present the technical realization of a high-speed hard X-ray single-photon counting-detection scheme based on a commercial avalanche silicon photodiode and high-speed oscilloscope. The development is motivated by the need to perform pulse-resolved photon-correlation and pump-probe studies at synchrotron sources with densely packed pulse patterns that result in high repetition rate pulses on the order of hundreds of MHz. Commissioning experiments are performed at the 1C PAL-KRISS beamline at PLS-II of South Korea operating at a burst mode maximum repetition rate of 500 MHz. In such a high count-rate measurement, detector dead-time can lead to a distortion of counting statistics. We are able to model the counting behavior of our detector under these conditions with a detector dead-time comparable to time between X-ray pulses, implying that nanosecond X-ray photon correlation spectroscopy should be possible at diffraction-limited light sources.

36 MATERIALS SCIENCE↗

Fabricating Graphene Oxide/h-BN Metal Insulator Semiconductor Diodes by Nanosecond Laser Irradiation

To employ graphene’s rapid conduction in 2D devices, a heterostructure with a broad bandgap dielectric that is free of traps is required. Within this paradigm, h-BN is a good candidate because of its graphene-like structure and ultrawide bandgap. We show how to make such a heterostructure by irradiating alternating layers of a-C and a-BN film with a nanosecond excimer laser, melting and zone-refining constituent layers in the process. With Raman spectroscopy and ToF-SIMS analyses, we demonstrate this localized zone-refining into phase-pure h-BN and rGO films with distinct Raman vibrational modes and SIMS profile flattening after laser irradiation. Furthermore, in comparing laser-irradiated rGO-Si MS and rGO/h-BN/Si MIS diodes, the MIS diodes exhibit an increased turn-on voltage (4.4 V) and low leakage current. The MIS diode I-V characteristics reveal direct tunneling conduction under low bias and Fowler-Nordheim tunneling in the high-voltage regime, turning the MIS diode ON with improved rectification and current flow. This study sheds light on the nonequilibrium approaches to engineering h-BN and graphene heterostructures for ultrathin field effect transistor device development.

2D materials↗

Sub-Nanosecond, Room-Temperature, Mid-IR Fe:ZnSe Gain-Switched Laser: Experimental Characterization and Modeling

We present the modeling and experimental characterization of a room-temperature, sub-nanosecond, gain-switched (GS) Fe:ZnSe laser operating at 4.4–4.8 μm. As pump sources, we used a 2.79 µm Q-switched Cr:Er:YSGG laser with a pulse duration of 52 ns and the 2.98 μm idler of a Nd:YAG pumped KTA-OPO system with a pulse duration of 9 ns. The shortest pulse durations were measured to be 1.4 ns and 0.7 ns under excitation by the Cr:Er:YSGG laser and KTA-OPO system, respectively. The developed Fe:ZnSe laser model showed good agreement with the experimental results. Optimization of the laser parameters based on model simulations suggests that an Fe:ZnSe microchip laser configuration could be achieved with a pulse duration of ~250 ps and an efficiency of ~20%.

Ghimire, Saugat↗

Digital system provides superregulation of nanosecond amplifier-discriminator circuit

Feedback system employing a digital logic comparator to detect and correct amplifier drift provides stable gain characteristics for nanosecond amplifiers used in counting applications. Additional anticoincidence logic enables application of the regulation circuit to the amplifier and discriminator while they are mounted in an operable circuit.

Forges, K. G.↗

Traveling-wave photodetector has sub-nanosecond response

Mercury-doped germanium photodetector uses waveguide which increases the absorption of microwave energy within the photodetectors. Waveguide and photodetector are placed in liquid helium Dewar and cooled. A carbon dioxide laser is light source and klystron provides microwave energy. Measured response times are approximately 1 nanosecond.

Sun, C.↗

Nanosecond radar observations of the ocean surface from a stable platform

The measurement of ocean surface waves with a nanosecond radar pulse from a fixed platform at vertical incidence is discussed. By reducing the pulse width of radar until the pulse width resolves the vertical water wave structure, a set of radar returns is available to describe the ocean surface characteristics which differs from returns obtained by conventional radars. A block diagram of the radar and the principles of operation are presented.

Yaplee, B. S.↗

Nanosecond time transfer via shuttle laser ranging experiment

A method is described to use a proposed shuttle laser ranging experiment to transfer time with nanosecond precision. All that need be added to the original experiment are low cost ground stations and an atomic clock on the shuttle. It is shown that global time transfer can be accomplished with 1 ns precision and transfer up to distances of 2000 km can be accomplished with better than 100 ps precision.

Reinhardt, V. S.↗

Open-loop nanosecond-synchronization for wideband satellite communications

A synchronization technique for use with an onboard processing satellite communication system is discussed. The satellite oscillator is used both as the system time reference and as the frequency source for all downlink carriers and data clocks. Downlink timing is established at each system earth terminal through a combination of carrier and data-clock tracking and a downlink timing epoch signal consisting of one bit per TDMA data burst. Uplink timing is established by an open-loop range prediction process using precision ephemerides calculated and distributed by the central control station. Overall timing accuracy of the uplink signal at the satellite receiver of + or - 7 nanoseconds permits unambiguous identification of each data bit position in a 128 Mbps TDMA burst. This is accomplished by means of simple, inexpensive terminal hardware using available crystal oscillators for time/frequency references and digital synthesis techniques that may be implemented in digital LSI chips.

Holmes, W. M., Jr.↗

Early Events in the Folding of an Amphipathic Peptide A Multi- Nanosecond Molecular Dynamics Study

Folding of the capped LQQLLQQLLQL peptide is investigated at the water-hexane interface by molecular dynamics simulations over 161.5 nanoseconds. Initially placed in the aqueous phase as a beta-strand, the peptide rapidly adsorbs to the interface, where it adopts an amphipathic conformation. The marginal presence of non-amphipathic structures throughout the complete trajectory indicate- that the corresponding conformations are strongly disfavored at the interface. It is further suggestive that folding in an interfacial environment proceeds through a pathway of successive amphipathic intermediates. The energetic and entropic penalties involved in the conformational changes along this pathway markedly increase the folding time-scales of LQQLLQQLLQL, explaining why the alpha-helix, the hypothesized lowest free energy structure for a sequence with a hydrophobic periodicity of 3.6, has not been reached yet. The formation of a type I beta-turn at the end of the simulation confirms the importance of such motifs as initiation sites allowing the peptide to coalesce towards a secondary structure.

Chipot, Christophe↗

Short pulsewidth high repetition rate nanosecond transient absorption spectrometer

A high-sensitivity nanosecond to millisecond transient absorption spectrometer for measurements of miniscule signals under low excitation intensities includes an excitation source generating a >100 Hz, <5 ns pulsewidth excitation pulse for exciting a light absorbing sample, a probe light source for generating a high photon flux probe light beam producing an average irradiance greater than 1 μW m-2 nm-1 for measuring the transient absorption spectrum of the sample before and after excitation by the excitation source, a DC-coupled detector capable of measuring light for enabling synchronous measurement of both the transmission of the probe light beam and the change in transmission of the probe light beam between a signal with the excitation pulse present and a signal in the absence of the excitation pulse, and a digital oscilloscope with a trigger rearm time capable of collecting every trigger event at frequencies including 1MHz, for enabling sequential noise subtraction protocols.

Rimshaw, Adam↗

Sub-nanosecond RF synchronization for MIMO software defined radio sensor networks

This disclosure presents distributed and decentralized synchronization for wireless transceivers. The disclosed system, device, and method achieve sub-nanosecond synchronization using low-cost commercial off the shelf software defined radios. By providing a decentralized mechanism that does not rely on a hierarchical master-slave structure, networks constructed as disclosed are robust to sensor drop-out in contested or harsh environments. Such networks may be used to create phased array radars and communication systems without requiring wired connections to distribute a common clock or local oscillator reference.

Moghaddam, Mahta↗