A simulation pipeline for fast neutron imaging and spectroscopy using quantified detector attributes

Radiation imaging capabilities, essential in the nuclear nonproliferation regime, facilitate source localization and, in certain cases, spectroscopy. Scatter-based neutron cameras, which can measure the neutron signatures from special nuclear material, hold particular interest. Systems incorporating organic scintillators can extract neutron energy spectra, potentially distinguishing fission neutron sources from others, such as alpha-neutron sources. The development and testing of a scatter-based neutron imager, however, can be challenging without having an accurate simulation model or first constructing a prototype. This work describes a simulation pipeline that takes output from MCNPX-PoliMi simulations and creates the expected back-projection neutron images and neutron energy spectra. This pipeline was developed to improve the modeling of fast neutron imagers and bridge the current gap in literature, which predominantly focuses on gamma-ray Compton imager models. This work also reports on the significance of various real-world system considerations and their effects on the simulated detector responses. The pipeline was verified and validated with experimental data collected using a 252 Cf spontaneous fission source using a fast neutron scattering imager developed at the University of Michigan.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Upgrade of the JET Gamma-Ray Cameras

The JET gamma-ray camera diagnostics have already provided valuable information on the gamma-ray imaging of fast ion in JET plasmas /1,2/. The applicability of gamma-ray imaging to high performance deuterium and deuterium-tritium JET discharges is strongly dependent on the fulfilment of rather strict requirements for the characterisation of the neutron and gamma-ray radiation fields. These requirements have to be satisfied within very stringent boundary conditions for the design, such as the requirement of minimum impact on the co-existing neutron camera diagnostics. The JET Gamma-Ray Cameras (GRC) upgrade project deals with these issues with particular emphasis on the design of appropriate neutron/gamma-ray filters ('neutron attenuators'). Several design versions have been developed and evaluated for the JET GRC neutron attenuators at the conceptual design level. The main design parameter was the neutron attenuation factor. The two design solutions, that have been finally chosen and developed at the level of scheme design, consist of: a) one quasi-crescent shaped neutron attenuator (for the horizontal camera) and b) two quasi-trapezoid shaped neutron attenuators (for the vertical one). The second design solution has different attenuation lengths: a short version, to be used together with the horizontal attenuator for deuterium discharges, and a long version to be used for high performance deuterium and DT discharges. Various neutron-attenuating materials have been considered (lithium hydride with natural isotopic composition and {sup 6}Li enriched, light and heavy water, polyethylene). Pure light water was finally chosen as the attenuating material for the JET gamma-ray cameras. The neutron attenuators will be steered in and out of the detector line-of-sight by means of an electro-pneumatic steering and control system. The MCNP code was used for neutron and gamma ray transport in order to evaluate the effect of the neutron attenuators on the neutron field of the JET GRC. The modelling was dedicated to the estimation of neutron and (plasma-emitted) gamma-ray attenuation, neutron-induced gamma-ray background and the neutron in-scattering impact on the neutron detectors due to the attenuator in the parking location. A numerical study of the gamma-ray detector (CsI(Tl)) was done by means of the IST Monte Carlo code. It provided preliminary results on the detector efficiency and response function.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Imaging vs. non-imaging in long range neutron detection scenarios.

Standoff neutron detection technology has advanced in recent years, primarily for counterterrorism applications. Sandia National Laboratories has developed the Neutron Scatter Camera -- a fast neutron imaging system using liquid scintillator with potential applications in long range neutron detection. This talk will explore the pros, cons and practical uses of the Neutron Scatter Camera versus more traditional neutron detectors such as He-3 proportional counters. Several applications for neutron detection and imaging will be explored. We will perform predictive calculations of the response of the Neutron Scatter Camera and traditional He-3 detectors. The applications range from counterterrorism to arms control to safeguards. We will discuss future evolution of the scatter camera to enhance long range detection.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Stabilization of sawteeth with third harmonic deuterium ICRF-accelerated beam in JET plasmas

Sawtooth stabilisation by fast ions is investigated in deuterium (D) and D-helium 3 (He3) plasmas of JET heated by deuterium Neutral Beam Injection combined in synergy with Ion Cyclotron Resonance Heating (ICRH) applied on-axis at 3rd beam cyclotron harmonic. A very significant increase in the sawtooth period is observed, caused by the ICRH-acceleration of the beam ions born at 100 keV to the MeV energy range. Four representative sawteeth from four different discharges are compared with Porcelli's model. In two discharges, the sawtooth crash appears to be triggered by core-localized Toroidal Alfvén Eigenmodes inside the q = 1 surface (also called “tornado” modes) which expel the fast ions from within the q = 1 surface, over time scales comparable with the sawtooth period. Two other discharges did not exhibit fast ion-driven instabilities in the plasma core, and no degradation of fast ion confinement was found in both modelling and direct measurements of fast ion profile with the neutron camera. The developed sawtooth scenario without fast ion-driven instabilities in the plasma core is of high interest for the burning plasmas. Possible causes of the sawtooth crashes on JET are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Investigating fusion plasma instabilities in the Mega Amp Spherical Tokamak using mega electron volt proton emissions (invited)

The proton detector (PD) measures 3 MeV proton yield distributions from deuterium-deuterium fusion reactions within the Mega Amp Spherical Tokamak (MAST). The PD’s compact four-channel system of collimated and individually oriented silicon detectors probes different regions of the plasma, detecting protons (with gyro radii large enough to be unconfined) leaving the plasma on curved trajectories during neutral beam injection. From first PD data obtained during plasma operation in 2013, proton production rates (up to several hundred kHz and 1 ms time resolution) during sawtooth events were compared to the corresponding MAST neutron camera data. Fitted proton emission profiles in the poloidal plane demonstrate the capabilities of this new system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Demonstration of achromatic cold-neutron microscope utilizing axisymmetric focusing mirrors

An achromatic cold-neutron microscope with magnification 4 is demonstrated. The image-forming optics is composed of nested coaxial mirrors of full figures of revolution, so-called Wolter optics. The spatial resolution, field of view, and depth of focus are measured and found consistent with ray-tracing simulations. Methods of increasing the resolution and magnification are discussed, as well as the scientific case for the neutron microscope. In contrast to traditional pinhole-camera neutron imaging, the resolution of the microscope is determined by the mirrors rather than by the collimation of the beam, leading to possible dramatic improvements in the signal rate and resolution.

43 PARTICLE ACCELERATORS↗

New developments in the diagnostics for the fusion products on JET in preparation for ITER (invited)

Notwithstanding the advances of the past decades, significant developments are still needed to satisfactorily diagnose ''burning plasmas.'' D-T plasmas indeed require a series of additional measurements for the optimization and control of the configuration: the 14 MeV neutrons, the isotopic composition of the main plasma, the helium ash, and the redistribution and losses of the alpha particles. Moreover a burning plasma environment is in general much more hostile for diagnostics than purely deuterium plasmas. Therefore, in addition to the development and refinement of new measuring techniques, technological advances are also indispensable for the proper characterization of the next generation of devices. On JET an integrated program of diagnostic developments, for JET future and in preparation for ITER, has been pursued and many new results are now available. In the field of neutron detection, the neutron spectra are now routinely measured in the energy range of 1-18 MeV by a time of flight spectrometer and they have allowed studying the effects of rf heating on the fast ions.A new analysis method for the interpretation of the neutron cameras measurements has been refined and applied to the data of the last trace tritium campaign (TTE). With regard to technological upgrades, chemical vapor deposition diamond detectors have been qualified both as neutron counters and as neutron spectrometers, with a potential energy resolution of about one percent. The in situ calibration of the neutron diagnostics, in preparation for the operation with the ITER-like wall, is also promoting important technological developments. With regard to the fast particles, for the first time the temperature of the fast particle tails has been obtained with a new high purity Germanium detector measuring the gamma emission spectrum from the plasma. The effects of toroidal Alfven eigenmodes modes and various MHD instabilities on the confinement of the fast particles have been determined with a combination of gamma ray cameras, neutral particle analyzers, scintillator probe, and Faraday cups. From a more technological perspective, various neutron filters have been tested to allow measurement of the gamma ray emission also at high level of neutron yield.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thermal Neutron Imaging Using A New Pad-Based Position Sensitive Neutron Detector

Thermal neutrons (with mean energy of 25 meV) have a scattering mean free path of about 20 m in air. Therefore it is feasible to find localized thermal neutron sources up to ~30 m standoff distance using thermal neutron imaging. Coded aperture thermal neutron imaging was developed in our laboratory in the nineties, using He-3 filled wire chambers. Recently a new generation of coded-aperture neutron imagers has been developed. In the new design the ionization chamber has anode and cathode planes, where the anode is composed of an array of individual pads. The charge is collected on each of the individual 5x5 mm2 anode pads, (48x48 in total, corresponding to 24x24 cm2 sensitive area) and read out by application specific integrated circuits (ASICs). The high sensitivity of the ASICs allows unity gain operation mode. The new design has several advantages for field deployable imaging applications, compared to the previous generation of wire-grid based neutron detectors. Among these are the rugged design, lighter weight and use of non-flammable stopping gas. For standoff localization of thermalized neutron sources a low resolution (11x11 pixel) coded aperture mask has been fabricated. Using the new larger area detector and the coarse resolution mask we performed several standoff experiments using moderated californium and plutonium sources at Idaho National Laboratory. In this paper we will report on the development and performance of the new pad-based neutron camera, and present long range coded-aperture images of various thermalized neutron sources.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Diagnostic of fusion neutrons on JET tokamak using diamond detector

In 2011-2012, an experimental campaign with a significant yield of fusion neutrons was carried out on the JET tokamak. During this campaign the facility was equipped with two diamond detectors based on natural and artificial CVD diamond. These detectors were designed and manufactured in State Research Center of Russian Federation TRINITI. The detectors measure the flux of fast neutrons with energies above 0.2 MeV. They have been installed in the torus hall and the distance from the center of plasma was about 3 m. For some of the JET pulses in this experiment, the neutron flux density corresponded to the operational conditions in collimator channels of ITER Vertical Neutron Camera. The main objective of diamond monitors was the measurement of total fast neutron flux at the detector location and the estimation of the JET total neutron yield. The detectors operate as threshold counters. Additionally a spectrometric measurement channel has been configured that allowed us to distinguish various energy components of the neutron spectrum. In this paper we describe the neutron signal measuring and calibration procedure of the diamond detector. Fluxes of DD and DT neutrons at the detector location were measured. It is shown that the signals of total neutron yield measured by the diamond detector correlate with signals measured by the main JET neutron diagnostic based on fission chambers with high accuracy. This experiment can be considered as a successful test of diamond detectors in ITER-like conditions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and performance of a large area neutron sensitive anger camera

We describe the design and performance of a 157mm x 157mm two dimensional neutron detector. The detector uses the Anger principle to determine the position of neutrons. We have verified FWHM resolution of < 1.2mm with distortion < 0.5mm on over 50 installed Anger Cameras. The performance of the detector is limited by the light yield of the scintillator, and it is estimated that the resolution of the current detector could be doubled with a brighter scintillator. Data collected from small (<1mm 3 ) single crystal reference samples at the single crystal instrument TOPAZ provide results with low R w (F) values

42 ENGINEERING↗

Reduced fast-ion transport calculations of m = n = 1 fishbone-like instabilities in MAST-U

Fast-ion transport associated with an m = n = 1 fishbone-like burst in MAST-U discharge 47128 is investigated using a reduced guiding-center-based transport model (ORBIT-Kick) constrained by multi-diagnostic measurements. The two-dimensional beam-emission spectroscopy system provides measurements of the core poloidal mode structure and fluctuation amplitude, while EFIT++ reconstructions constrained by the motional Stark effect diagnostic indicate a flat q-profile with q 0 > 1⁠, indicating the absence of a resonant q = 1 surface and supporting a pressure-driven infernal-mode interpretation. Analytic m = n = 1 displacement profiles consistent with the measured core mode structure and equilibrium constraints are used as the mode structure inputs to ORBIT-Kick. The calculations show that the dominant resonances occur between the mode and co-passing fast ions, producing redistribution localized near the magnetic axis. Synthetic neutron camera signals from TRANSP-Kick recover up to 90% of the experimentally observed neutron deficit at the time of peak mode amplitude, indicating that the measured m = n = 1 mode is a dominant contributor to core fast-ion transport. However, the synthetic neutron signals recover rapidly, whereas the measured neutron emission continues to decrease after the peak amplitude. In conclusion, the remaining discrepancy may arise from contributions not included in the present single-harmonic model, including higher-m and higher-n harmonics, multi-harmonic interactions, and additional transport mechanisms, motivating future diagnostic development and modeling efforts to resolve and incorporate these additional contributions.

Wong, Henry H. [University of California, Los Ange↗