Search NASA⌕ Search

SEARCH · Search NASA

Results for “Neutron activation system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Background simulations and shielding calculations

Key improvements in the sensitivity of the underground particle astrophysics experiments can only be achieved if the radiation causing background events in detectors is well understood and proper measures are taken to suppress it. The background radiation arising from radioactivity and cosmic-ray muons is discussed here together with the methods of its suppression. Different shielding designs are considered to attenuate gamma-rays and neutrons coming from radioactivity in rock and lab walls. Purity of materials used in detector construction is analysed and the background event rates due to the presence of radioactive isotopes in detector components are discussed. Event rates in detectors caused by muon-induced neutrons with and without active veto systems are presented leading to the requirements for the depth of an underground laboratory and the efficiency of the veto system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron Interrogation System For Underwater Threat Detection And Identification

Wartime and terrorist activities, training and munitions testing, dumping and accidents have generated significant munitions contamination in the coastal and inland waters in the United States and abroad. Although current methods provide information about the existence of the anomaly (for instance, metal objects) in the sea bottom, they fail to identify the nature of the found objects. Field experience indicates that often in excess of 90% of objects excavated during the course of munitions clean up are found to be non-hazardous items (false alarm). The technology to detect and identify waterborne or underwater threats is also vital for protection of critical infrastructures (ports, dams, locks, refineries, and LNG/LPG). We are proposing a compact neutron interrogation system, which will be used to confirm possible threats by determining the chemical composition of the suspicious underwater object. The system consists of an electronic d-T 14-MeV neutron generator, a gamma detector to detect the gamma signal from the irradiated object and a data acquisition system. The detected signal then is analyzed to quantify the chemical elements of interest and to identify explosives or chemical warfare agents.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Education and training in the field of nuclear instrumentation and measurement: CEA/INSTN (National Institute for Nuclear Sciences and Technologies) strategy to improve and develop new pedagogical tools and methods

Part of the French Alternative Energies and Atomic Energy Commission (CEA), the National Institute for Nuclear Science and Technology (INSTN) is a higher education institution whose mission is to provide students and professionals a high level of scientific and technological qualification in all disciplines related to nuclear energy applications. In this frame, INSTN carries out education and training (E and T) programs in nuclear instrumentation and radioprotection. Its strategy has always been to complete theoretical courses by training courses and laboratory works carried out on an extensive range of training tools that includes a large panel of nuclear instrumentation as well as software applications. Since its creation in 1956, the INSTN has conducted both education and vocational programs on ionizing radiation detection. An extensive range of techniques have commonly been used during practical works with students and employees of companies who need to get the knowledge and specialization in this field. Today, the INSTN is mainly equipped with usual detectors and electronics in large numbers in order to be able to accommodate up to 48 trainees at the same time in two classrooms, with only two trainees for one workstation in order to optimize their learning. In the field of the neutron detection systems, the INSTN has strongly developed its offer taking advantage of the use of research reactors, such as ISIS reactor (700 kW) at Saclay. The implementation of neutron detection systems specific to the courses offers a unique way of observing and analysing the signal coming from neutron detectors, as well as learning how to set the parameters of the detection system in real conditions. Providing the trainees with an extensive overview of each part of the neutron monitoring instrumentation apply to a nuclear reactor, hands-on measurements on the ISIS reactor play a major role in ensuring a practical and comprehensive understanding of the neutron detection system and their integration in the safety system of nuclear reactors. It also gives a solid background for the follow up and the development of the neutron detection systems. Another field of activity of the INSTN is the development of new teaching tools using software applications. We describe hereafter two applications that have recently been developed by the institute, O.S.I.R.I.S and DOSIMEX. The INSTN and the company OREKA have developed an innovative teaching tool named O.S.I.R.I.S. The tool is built on a virtual 3D environment in which users operate in a totally free way. The action is located in a pressurised water reactor in the environment of a steam generator building. The users are students or professionals who want to learn and train on concrete situations on how to protect the workers against radiation. Through the use of this serious game, users must: establish a predictive dose evaluation, implement the principles of radiation protection, perform the dose result of the operation, analyse the gap between the predictive collective dose and the collective dose achieved, and decide about the lessons to provide feedback. Taking into account the increasing constraints related to radiation protection, it is essential to use computer codes to evaluate the dose rates generated by sources of ionizing radiation. Many powerful codes exist but are often relatively complex to implement and are dedicated to experts. In addition, these codes are often 'black boxes' that does not allow the user to understand the underlying physics. The objective of DOSIMEX codes developed by the INSTN is to give, by the means of a VBA code with a simple interface, the ability to easily conduct a wide range of radiological exposure situations: calculation of gamma, beta, neutron equivalent dose rate, calculation of internal contamination and atmospheric transfer.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Overview of the JET preparation for deuterium–tritium operation with the ITER like-wall

For the past several years, the JET scientific programme (Pamela et al 2007 Fusion Eng. Des. 82 590) has been engaged in a multi-campaign effort, including experiments in D, H and T, leading up to 2020 and the first experiments with 50%/50% D–T mixtures since 1997 and the first ever D–T plasmas with the ITER mix of plasma-facing component materials. For this purpose, a concerted physics and technology programme was launched with a view to prepare the D–T campaign (DTE2). This paper addresses the key elements developed by the JET programme directly contributing to the D–T preparation. This intense preparation includes the review of the physics basis for the D–T operational scenarios, including the fusion power predictions through first principle and integrated modelling, and the impact of isotopes in the operation and physics of D–T plasmas (thermal and particle transport, high confinement mode (H-mode) access, Be and W erosion, fuel recovery, etc). This effort also requires improving several aspects of plasma operation for DTE2, such as real time control schemes, heat load control, disruption avoidance and a mitigation system (including the installation of a new shattered pellet injector), novel ion cyclotron resonance heating schemes (such as the three-ions scheme), new diagnostics (neutron camera and spectrometer, active Alfvèn eigenmode antennas, neutral gauges, radiation hard imaging systems...) and the calibration of the JET neutron diagnostics at 14 MeV for accurate fusion power measurement. The active preparation of JET for the 2020 D–T campaign provides an incomparable source of information and a basis for the future D–T operation of ITER, and it is also foreseen that a large number of key physics issues will be addressed in support of burning plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Activation of enriched environmental xenon by 14-MeV neutrons

The international monitoring system exists to verify compliance with the terms of the comprehensive test ban treaty. About 10% of the member stations will be capable of detecting radioxenon, which can be produced in nuclear detonations or through civilian processes. We have studied the activation of radioxenon by the prompt, intense spectrum of 14-MeV neutrons produced at the National Ignition Facility. While 14-MeV neutrons are not currently a significant contributor to the production of radioxenon, we find that radioxenon produced through activation of environmental xenon by 14-MeV neutrons would be distinguishable from activation by nuclear tests.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

How to reduce Shutdown Dose Rates in ITER Diagnostics Equatorial Ports

The ITER vacuum vessel presents 54 access ports, arranged in three levels, where port plugs are inserted hosting different types of systems: test blanket modules, antennas, vacuum pumps, neutral beam injectors and diagnostics. At the equatorial level, nine out of the eighteen access ports present diagnostics port plugs, in which the diagnostics systems are deployed into three DSMs (Diagnostics Shield Modules). The DSMs, being a major constituent in volume of the port plugs, must help to fulfill the design target of Shutdown Dose Rates (SDDR) corresponding to 100 μSv.h{sup -1} after 10{sup 6} s of cooling time for planned in-situ maintenance operations in the port interspace. Additionally, the DSMs are largely responsible for the port plug drained weight limit of 45 T, which imposes limitations to the shielding technology. Up to now, all the proposed DSM designs combine differently stainless steel, water and/or B{sub 4}C as shielding to accommodate a maximum of 1.1 m{sup 3} of DSM bulk shield, contained into a L 1845 x W 518 x H 2011 mm stainless steel box weighting 5.8 T for each DSM. These proposals show insufficient shielding properties with respect to SDDR, while none of them satisfies currently the weight limit. However, during 2016, a new DSM concept has been developed, named 'modular DSM', with significant engineering advances and changes. The DSM length has been increased by 500 mm, up to 2345 mm. The SS box has been reduced to the minimum structure required, presenting the same weight while being larger and hosting a larger volume of bulk shielding inside. Thus, the volume of bulk shielding has been enlarged up to 1.5 m{sup 3} per DSM. The shielding technology is based on B{sub 4}C bricks deployed in SS trays that are attached to the vertical plates. This results in a bulk shielding made of 65% of B{sub 4}C, 10% SS and 25% void, with effective density of 2.4 g.cm{sup -3}. In summary, the modular DSM, without a weight increase, hosts extra 0.5 m3 of bulk shielding along an additional 500 mm of length, to be used with a light but highly neutron absorber, what allows fitting the weight limit of 45 T for the port plug once drained. From now, the non-modular DSMs will be referred as 'short DSMs'. The modular DSM's advantages with respect to the short DSM versions have shown that the DSMs design can be improved in generic approach, i.e. when the penetrations of the systems are not taken into consideration. A mention apart is required when port specific penetrations are considered. Provided that they will be an important radiation transmission path, their presence could significantly diminish the improvement. To clarify this issue, in this work we have carried out a nuclear analysis of the ITER equatorial port no. 11 integration considering the modular DSM. It is a first plasma port hosting the following 6 major diagnostics systems: Neutral Particle Analyzer (NPA), H-α monitor, Low Field Side (LFS) reflectometry, Visible - Ultraviolet divertor (VUV div), Visible - Ultraviolet core survey (VUV CS) and X-rays Crystal System (XRCS). For the baseline case, a SDDR matrix has been derived assigning responsibilities to the different EP no. 11 individual systems in terms of neutron flux transmission through them, and the related activation due to that neutron flux (activation of itself, but also of the rest of systems taken one by one). Different EP no. 11 configurations have been studied in addition to the baseline case. For example, the backfill of the port plug penetrations to protect all the empty space not required for systems sight. Another issue is the determination of the role of the Co impurity content minimization from 0.05 wt.% to 0.03 wt.% recently proposed. In this summary, only some results related to the baseline are given.

61 RADIATION PROTECTION AND DOSIMETRY↗

Comparison Of 252 Cf Time Correlated Induced Fisssion With AmLi Induced Fission On Fresh MTR Research Reactor Fuel

The effective application of international safeguards to research reactors requires verification of spent fuel as well as fresh fuel. To accomplish this goal various nondestructive and destructive assay techniques have been developed in the US and around the world. The Advanced Experimental Fuel Counter (AEFC) is a nondestructive assay (NDA) system developed at Los Alamos National Laboratory (LANL) combining both neutron and gamma measurement capabilities. Since spent fuel assemblies are stored in water, the system was designed to be watertight to facilitate underwater measurements by inspectors. The AEFC is comprised of six 3 He detectors as well as a shielded and collimated ion chamber. The 3 He detectors are used for active and passive neutron coincidence counting while the ion chamber is used for gross gamma counting. Active coincidence measurement data is used to measure residual fissile mass, whereas the passive coincidence measurement data along with passive gamma measurement can provide information about burnup, cooling time, and initial enrichment. In the past, most of the active interrogation systems along with the AEFC used an AmLi neutron interrogation source. Owing to the difficulty in obtaining an AmLi source, a 252 Cf spontaneous fission (SF) source was used during a 2014 field trail in Uzbekistan as an alternative. In this study, experiments were performed to calibrate the AEFC instrument and compare use of the 252 Cf spontaneous fission source and the AmLi (α,n) neutron emission source. The 252 Cf source spontaneously emits bursts of time-correlated prompt fission neutrons that thermalize in the water and induce fission in the fuel assembly. The induced fission (IF) neutrons are also time correlated resulting in more correlated neutron detections inside the 3 He detector, which helps reduce the statistical errors in doubles when using the 252 Cf interrogation source instead of the AmLi source. In this work, two MTR fuel assemblies varying both in size and number of fuel plates were measured using 252 Cf and AmLi active interrogation sources. This paper analyzes time correlated induced fission (TCIF) from fresh MTR fuel assemblies due to 252 Cf and AmLi active interrogation sources.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A new online detector for estimation of peripheral neutron equivalent dose in organ

Purpose: Peripheral dose in radiotherapy treatments represents a potential source of secondary neoplasic processes. As in the last few years, there has been a fast-growing concern on neutron collateral effects, this work focuses on this component. A previous established methodology to estimate peripheral neutron equivalent doses relied on passive (TLD, CR39) neutron detectors exposed in-phantom, in parallel to an active [static random access memory (SRAMnd)] thermal neutron detector exposed ex-phantom. A newly miniaturized, quick, and reliable active thermal neutron detector (TNRD, Thermal Neutron Rate Detector) was validated for both procedures. This first miniaturized active system eliminates the long postprocessing, required for passive detectors, giving thermal neutron fluences in real time. Methods: To validate TNRD for the established methodology, intrinsic characteristics, characterization of 4 facilities [to correlate monitor value (MU) with risk], and a cohort of 200 real patients (for second cancer risk estimates) were evaluated and compared with the well-established SRAMnd device. Finally, TNRD was compared to TLD pairs for 3 generic radiotherapy treatments through 16 strategic points inside an anthropomorphic phantom. Results: The performed tests indicate similar linear dependence with dose for both detectors, TNRD and SRAMnd, while a slightly better reproducibility has been obtained for TNRD (1.7% vs 2.2%). Risk estimates when delivering 1000 MU are in good agreement between both detectors (mean deviation of TNRD measurements with respect to the ones of SRAMnd is 0.07 cases per 1000, with differences always smaller than 0.08 cases per 1000). As far as the in-phantom measurements are concerned, a mean deviation smaller than 1.7% was obtained. Conclusions: The results obtained indicate that direct evaluation of equivalent dose estimation in organs, both in phantom and patients, is perfectly feasible with this new detector. This will open the door to an easy implementation of specific peripheral neutron dose models for any type of treatment and facility.

60 APPLIED LIFE SCIENCES↗

Overview of Nuclear Integration Activities for Mitigation of Radiation Loads to ITER Superconducting Magnets

The Nuclear Integration Unit (NIU) is a trans-departmental team from the ITER Organization and Domestic Agencies, responsible for all nuclear integration aspects of the facility and for ensuring that systems and components are suitable for their radiation environment and satisfy all related performance requirements. This is a very challenging task namely due to the large number of systems, their still evolving designs, the intricate and far-reaching impacts of these in nuclear responses everywhere, and the complex world-wide distribution of procurement responsibilities. A sound systems engineering approach that involves all relevant experts and stakeholders, and trades-off between different performance requirements in an optimum way, needs to be taken and sustained during design evolution and construction, always with the objective of final overall project success. One of the most important current occupations of the NIU is the evaluation of, and protection from, radiation conditions to superconducting magnets during plasma operations, and particularly nuclear heating. This requires neutronic analyses in massive computer resources, with state-of-the-art methods and complex, extensive computer models. The main ITER superconducting magnet systems subject to significant nuclear loads are the toroidal field coils (TFCs) and the poloidal field coils (PFCs). These are illustrated in Fig. 1. Nuclear responses in these depend mostly on the design of all in-vessel (blankets, manifolds, divertor, in-vessel coils, port plugs), vessel and thermal shield components. Sources to consider are the 500 MW DT burning plasma (14.1 MeV neutrons) and the activated water in the in-vessel cooling system (photons up to 7 MeV from N-16 and neutrons up to 3.5 MeV from N-17). This paper discusses a snapshot of the present understanding of nuclear heat conditions in both the TFC and PFC magnets. This includes integral values and distributions, as well as best estimates from computations and conservative upper estimates by consideration of systematic effects and random uncertainties. The computer models, methods and assumptions used for evaluation of these responses are described. Nuclear integration aspects and ongoing efforts to study and implement additional shielding and other mitigating measures are also discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characterization of D-T Generator Neutron Flux Spectrum for Cyclic Neutron Activation Analysis Experiments

Improving nuclear data for short-lived fission product yields will further our fundamental understanding of fission, which is needed across various scientific fields and applications. One method of attaining the needed product yield data is through cyclic neutron activation, which allows a target to be irradiated in a neutron environment and then transported for counting of the radionuclides produced, typically via g spectroscopy. Recently, such a system has been constructed and commissioned at Pacific Northwest National Laboratory. Targets are shuttled between the head of a D-T neutron generator and a counting station with a transit time of 2 seconds. As part of the characterization of this system, the neutron flux was studied using two activation targets. The neutron flux from the deuterium-tritium fusion generator was determined to be 9.95(33) x10^8 n/cm2-s with a peak energy of 14.9 MeV and a spread of approximately 4 decades between the epithermal and 14 MeV peak group flux.

cyclic neutron activation, gamma-ray spectroscopy,↗

A SECOND NEUTRON STAR IN M4?

We show that the optical counterpart of the X-ray source CX 1 in M4 is a {approx}20th magnitude star, located in the color-magnitude diagram on (or very close to) the main sequence of the cluster, and exhibiting sinusoidal variations of the flux. We find the X-ray flux to be also periodically variable, with X-ray and optical minima coinciding. Stability of the optical light curve, lack of UV-excess, and unrealistic mean density resulting from period-density relation for semidetached systems speak against the original identification of CX 1 as a cataclysmic variable. We argue that the X-ray active component of this system is a neutron star (probably a millisecond pulsar).

79 ASTRONOMY AND ASTROPHYSICS↗

Calibration of an ultra-low-background proportional counter for measuring {sup 37}Ar

An ultra-low-background proportional counter design has been developed at Pacific Northwest National Laboratory (PNNL) using clean materials, primarily electro-chemically-purified copper. This detector, along with an ultra-low-background counting system (ULBCS), was developed to complement a new shallow underground laboratory (30 meters water-equivalent) at PNNL. The ULBCS design includes passive neutron and gamma shielding, along with an active cosmic-veto system. This system provides a capability for making ultra-sensitive measurements to support applications like age-dating soil hydrocarbons with {sup 14}C/{sup 3}H, age-dating of groundwater with {sup 39}Ar, and soil-gas assay for {sup 37}Ar to support On-Site Inspection (OSI). On-Site Inspection is a key component of the verification regime for the Comprehensive Nuclear-Test-Ban Treaty (CTBT). Measurements of radionuclides created by an underground nuclear explosion are valuable signatures of a Treaty violation. For OSI, the 35-day half-life of {sup 37}Ar, produced from neutron interactions with calcium in soil, provides both high specific activity and sufficient time for inspection before decay limits sensitivity. This work describes the calibration techniques and analysis methods developed to enable quantitative measurements of {sup 37}Ar samples over a broad range of proportional counter operating pressures. These efforts, along with parallel work in progress on gas chemistry separation, are expected to provide a significant new capability for {sup 37}Ar soil gas background studies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterizing the Thermal Column Beam in the University of Massachusetts Lowell Research Reactor

The University of Massachusetts Lowell operates a 1 MW, light water cooled and moderated Research Reactor (UMLRR) fueled by low-enriched uranium to generate neutron flux that is used at a variety of in-core and beam port facilities within the reactor to perform irradiation experiments for academic and industrial research. One of the irradiation sites is a graphite-moderated thermal column designed to deliver a collimated beam of thermal neutrons to a neutron radiography imaging system. A detailed characterization of the neutron beam is essential for the design and interpretation of experiments at the facility and for radiation safety. This work aimed to characterize the neutron flux and energy spectrum in the UMLRR thermal column beam by employing experimental and computational methods known as the foil activation and spectrum unfolding technique. A previously existing Monte Carlo N-Particle transport (MCNP) model of the UMLRR reactor core has been extended to the thermal column where the neutron flux and energy spectrum have been computed and experimentally validated. This work employed the foil activation and spectrum unfolding technique along with neutron transport computation to extend the knowledge of the neutron fluence and energy spectrum from the UMLRR core to the adjacent thermal column beam. Radiography systems are used for materials characterization, studying dynamic behavior of engineering systems, and for nuclear forensics applications. Foil activation is an experimental method where thin foils of highly pure materials are placed in the beam where interactions between the neutrons and the foil material activate radioisotopes in the foils whose activities can be measured after the irradiation. Downstream computation with MCNP and the spectrum unfolding code SAND can deconvolute the neutron fluence and energy spectrum that must have been necessary to induce the production rates of radioisotopes that were obtained through foil activation. The necessary ingredients for successful spectrum unfolding are the experimentally measured production rates and some a priori (initial guess) knowledge of the flux spectrum. The thermal column is equipped with a neutron radiography imaging system, so any experimenters who desire to use neutron radiography at UMass Lowell will benefit significantly from knowing the characteristics of the neutron beam. Comprehensive knowledge of these characteristics of the beam is essential to compare and benchmark results obtained for similar experiments at other facilities. The Integrated Nuclear Security and Safeguards Laboratory (INSSL) is pursuing the investigation of the performance of self-healing materials under stress-strain environments and the characterization of radiation detectors and special containers for storing and transporting nuclear material. This work contributes to the improvement of the current radiography system, expands the utility of the system for nuclear safeguards and security application and provides information that will enhance the general safety of the UMLRR experimental facilities. The main objective of this work has been achieved; an appropriate neutron flux spectrum for the UMLRR thermal column beam has been determined using the foil activation method followed by spectrum unfolding. There now exists an experimentally validated computational model of the neutron flux spectrum and the thermal column's neutron environment is characterized. We can conclude that the thermal column is well characterized; an appropriate neutron flux spectrum has been determined through an experimentally validated computational model. Future experimenters interested in the thermal column may now expand on the computational model or use the spectral information for their own purposes. The knowledge gained herein will be helpful for the INSSL's future work using neutron radiography to analyze the effectiveness of self-healing materials and special containers. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Analysis of Shutdown Dose Rate in Fusion Energy Systems Using Hybrid Monte Carlo/Deterministic Techniques - Paper 138

Accurate assessments of shutdown dose rate (SDDR) are critical to support operation, maintenance, and waste disposal planning and to guide possible design changes of critical components in fusion energy systems. An SDDR calculation involves three steps: 1. a neutron transport calculation to determine the space and energy neutron flux distributions, 2. an activation calculation for computing the photon source distribution, and 3. a photon transport calculation for the estimation of the final SDDR. A companion paper describes the challenges of SDDR computations in fusion energy systems and the status of the techniques that are currently being used in SDDR analysis. Of these techniques, the rigorous 2-step (R2S) computational system entails Monte Carlo (MC) neutron and photon transport calculations coupled with a comprehensive activation step using a dedicated inventory code and library. The use of global MC variance reduction techniques was suggested for accelerating the SDDR MC neutron transport calculation. These techniques, which attempt to calculate MC tallies with nearly uniform relative uncertainties in both the low-flux space-energy regions and the high-flux space-energy regions, do not preferentially focus the MC computational efforts toward space-energy regions of high importance to the final decay dose. The ability of these approaches to accurately predict SDDR is inhibited by their prohibitive computational costs, which will be on the order of thousands of processor-years for full-scale modeling of an entire fusion plant. The companion paper describes the theoretical background of the Multi-Step Consistent Adjoint Driven Importance Sampling (MS-CADIS) method, which has been proposed to speed up SDDR MC neutron calculations. The MS-CADIS method uses the CADIS method, which has been successfully used for more than a decade in shielding calculations, but focuses on multistep shielding calculations such as SDDR analyses. The companion paper also describes a new method for calculating the uncertainties in SDDR due to uncertainties in the MC neutron calculation. This new method of uncertainty propagation uses the MS-CADIS neutron adjoint source to propagate the uncertainties in the neutron fluxes to the SDDR. This paper describes the application of the MS-CADIS method for speeding up the SDDR MC calculations and for calculating the SDDR uncertainty due to the neutron flux uncertainties. A new metric for assessing the reliability of SDDR calculations was also suggested and used in this analysis. The ITER benchmark problem was used in this analysis. The problem resembles the configuration and geometrical arrangement of an upper port plug in ITER. The analysis compared the efficiency of the MS-CADIS method to the traditional approach of using global MC variance reduction techniques for speeding up SDDR MC neutron calculation. The application of the MS-CADIS method to SDDR calculations in fusion energy systems was tested using the ITER benchmark problem. Compared to the standard FW-CADIS method, the increase in the efficiency of the SDDR neutron MC calculation due to the use of the MS-CADIS method was between 18% and 69%. The MS-CADIS method also increases the fraction of non-zero-scoring mesh tally elements in the space-energy regions of high importance to the final SDDR. Implementation of the MS-CADIS method in the SCALE and the ADVANTG code systems is currently under way. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Design and testing of a combined neutron and gamma assay system for measuring fissile material in fuel and waste items - 15340

A combined neutron and gamma ray assay system for the measurement of fissile material in both fuel and waste items has been designed, modelled, developed and tested. The purpose of the system is to measure and characterize a wide range of fissile materials including uranium, plutonium, americium and mixed oxide fuel arising from a variety of processes and facilities across the United Kingdom. Dounreay Site Restoration Limited at Dounreay currently stores these items form the United Kingdom Nuclear Decommissioning Authority's un-irradiated fuel inventory. This inventory comprises historic materials from ex-United Kingdom Atomic Energy Authority nuclear fuel projects and experiments together with fast reactor fuel materials and some commercial fuel items as delivered to Dounreay for recovery. The combined assay system has been designed and constructed to support the operation of a fuel processing facility, which will be operated at Dounreay to treat these historic legacy fuel materials, making them suitable for long term storage. Appropriate characterization of the fissile material is required for safety, criticality control and nuclear materials safeguards purposes prior to final disposition. The system consists of both gamma ray and neutron measurement components. The results of a neutron measurement are combined with the gamma ray isotopic ratio measurement results to generate the assay result for the fissile material being characterized. The gamma ray component of the system employs a safeguards quality high purity Germanium detector with electro-mechanical cooling and the measurements of fissile material containers are made in a shielded chamber with a tin and copper graded lining. Containers of fissile material are rotated during the gamma ray measurement and a variable automatic steel collimator aperture mechanism is employed to adjust the measured count rate to control detector dead time. Gamma ray spectra are analysed using the plutonium and uranium isotopic ratio code PC/FRAM. The gamma ray system can also be configured to perform a direct assay of small quantities of uranium bearing material. For this assay measurement a series of cadmium filters can be positioned in front of the detector to reduce the contribution from 59 keV gamma rays from Am-241. In addition to gamma ray isotopic measurements, both active and passive neutron assay is performed by the system. The neutron-measuring component consists of a thick walled cylindrical polyethylene chamber, which provides neutron moderation for 30 one-inch diameter He-3 detector tubes located in re-entrant channels in the polyethylene moderator. Two removable polyethylene-inserts incorporating lower plug assemblies are provided, one with and one without a cadmium lining. Also two top plug units are provided, again one with cadmium and one without a cadmium liner. The Neutron Subsystem can be operated both as a passive and as an active neutron coincidence counter. In both fast and thermal active neutron mode, the neutron component employs two americium-beryllium (Am-Be) alpha-n neutron sources, one positioned in the top and the other in the bottom plug unit. The neutron sources are removed when the counter is operated in passive mode. Passive neutron detection efficiency and active neutron performance has been modelled using the MCNP Monte Carlo computer simulation code as part of the design process. In the absence of fissile samples, operation of the gamma ray component of the system has been tested initially using calibrated Eu-152 and Ba-133 gamma ray sources and the use of archived spectra from fissile material measurements. Initial testing of the neutron system has employed a calibrated Cf-252 spontaneous fission neutron source. Neutron testing has been confirmed using further MCNP simulations. The results of test measurements with the system are presented and compared with the results of MCNP measurement simulations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Polarity of Co-solvents Regulates the Charge Storage Mechanisms in Supercapacitors with Concentrated Electrolytes

Developing better energy storage devices depends on comprehending the underlying mechanisms involved in charge storage. With the continuous conception of new electrolytes, this task becomes progressively more urgent and complex. An example is the utilization of co-solvated concentrated solutions. While these show promising electrochemical responses, their dynamic properties (especially under confinement) and their relationships with performance are not fully understood. Here, we combined modified step potential electrochemical spectroscopy and quasielastic neutron scattering to investigate systems composed of activated mesoporous carbon (AMC) and concentrated solutions of lithium bis(trifluoromethanesulfonyl)imide in acetonitrile co-solvated with either toluene or acetone. Further, we report that acetone does not impair surface-controlled mechanisms, contrary to the case with toluene, which competes with charged species to populate the AMC’s pores without contributing to charge storage. In turn, toluene promotes a greater overall capacitance owing to Faradaic processes, which may be related to changes in the solvation structures under confinement.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Reexamining the variational two-particle reduced density matrix for nuclear systems

We report that in most nuclear many-body methods, observables are calculated using many-body wave functions explicitly. The variational two-particle reduced density matrix method is one of the few exceptions to the rule. Ground-state energies of both closed-shell and open-shell nuclear systems can indeed be evaluated by minimizing a constrained linear functional of the two-particle reduced density matrix. However, it has virtually never been used in nuclear theory, because nuclear ground states were found to be well overbound, contrary to those of atoms and molecules. Consequently, we introduced new constraints in the nuclear variational two-particle reduced density matrix method, developed recently for atomic and molecular systems. Our calculations then show that this approach can provide a proper description of nuclear systems where only valence neutrons are included. For the nuclear systems where both neutrons and protons are active, however, the energies obtained with the variational two-particle reduced density matrix method are still overbound. The possible reasons for the noticed discrepancies and solutions to this problem will be discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Stellarator Design Exploration Using Symbolic-Regression Neutronics Surrogates

Systems codes require fast, simplified models to rapidly evaluate fusion power plant concepts, but neutronics analyses are often a computational bottleneck. Here, to address this, surrogate models for key neutronics responses have been developed using 3-D neutronics-ready models built with the open-source code ParaStell from a database of stellarator equilibria. Neutronics responses such as tritium breeding ratio (TBR), nuclear heating, and neutron-induced radiation damage displacements per atom (dpa) were simulated using OpenMC. Through sensitivity analysis and symbolic regression (SR), simple power-law formulas were derived connecting these neutronics responses to global stellarator parameters, including fusion power, plasma surface area, and plasma elongation. Validation shows these formulas can predict the simulation results with low error, enabling quick and accurate assessment of neutronics requirements in stellarator design exploration activities with systems codes.

Modeling↗