Application of 14 MeV and Cf-252 neutron sources to instrumental neutron activation analysis of lunar samples
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
No abstract available
No abstract available
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Neutron flux measurements by the Lunar Exploration Neutron Detector (LEND) on the Lunar Reconnaissance Orbiter (LRO) enable quantifying hydrogen-bearing volatiles in the lunar surface from orbit. Accurately determining hydrogen abundance requires discriminating between the instrument background detection rate and the population of lunar-sourced neutrons that are sensitive to surficial hydrogen. We have investigated the detection rate for lunar and non-lunar (spacecraft-sourced) neutrons in LEND by modeling maps of measured count rate in three LEND detector systems using linear combinations of maps compiled from LEND detectors and from the Lunar Prospector Neutron Spectrometer. We find that 30% of the global-average 24.926 +/- 0.020 neutron counts per second (cps) detected by the LEND STN3 thermal-energy neutron sensor are lunar-sourced neutrons in the thermal energy range (E < 0.4 eV), 65% are lunar-sourced neutrons in the epithermal and fast energy range (E > 0.4 eV), and 5% are from spacecraft-sourced background signal. In the SETN epithermal neutron detector, 90% of the 10.622 +/- 0.002 neutron detections per second are consistent with a lunar source of epithermal and fast neutrons combined (E > 0.4 eV), with 3% due to lunar-sourced thermal neutron leakage into the detector (E < 0.4 eV), and background signal accounting for 7% of total detections. Background signal due to spacecraft-derived neutrons is substantial in the CSETN collimated detector system, accounting for 57% of the global average detection rate of 5.082 +/- 0.001 cps, greater than the 48% estimated from cruise-phase data. Lunar-sourced epithermal and fast neutrons account for 43% of detected neutrons, including neutrons in collimation as well as neutrons that penetrate the collimator wall to reach the detector. We estimate a lower limit of 17% of lunar-sourced neutrons detected by CSETN are epithermal neutrons in collimation (0.37 cps), with an upper limit estimate of 54 +/- 11% of lunar-sourced neutrons received in collimation, or 1.2 +/- 0.2 cps global average. The pole-to-equator contrast ratio in epithermal and high-energy epithermal neutron flux indicates that the average concentration of hydrogen in the polar regolith above 80deg north or south latitude is ∼105 ppmw (parts per million by weight), or 0.095 +/- 0.01 wt% water-equivalent hydrogen. Above 88deg north or south, the concentration increases to ∼140 ppmw, or 0.13 +/- 0.02 wt% water-equivalent hydrogen. The similar pattern of neutron flux suppression at both poles suggests that hydrogen concentration generally increases nearer the pole and is not closely associated with a specific feature such as Shackleton Crater at the lunar south pole that has no northern counterpart. Epithermal neutron flux decreases with increasing latitude outside the polar regions, consistent with surface hydration that increases with latitude if that hydration extends to ∼13-40 cm into the surface.
Neutron flux measurements by the Lunar Exploration Neutron Detector (LEND) on the Lunar Reconnaissance Orbiter (LRO) enable quantifying hydrogen-bearing volatiles in the lunar surface from orbit. Accurately determining hydrogen abundance requires discriminating between the instrument background detection rate and the population of lunar-sourced neutrons that are sensitive to surficial hydrogen. We have investigated the detection rate for lunar and non-lunar (spacecraft-sourced) neutrons in LEND by modeling maps of measured count rate in three LEND detector systems using linear combinations of maps compiled from LEND detectors and from the Lunar Prospector Neutron Spectrometer. We find that 30% of the global-average 24.926 0.020 neutron counts per second (cps) detected by the LEND STN3 thermal-energy neutron sensor are lunar-sourced neutrons in the thermal energy range (E < 0.4 eV), 65% are lunar-sourced neutrons in the epithermal and fast energy range (E > 0.4 eV), and 5% are from spacecraft-sourced background signal. In the SETN epithermal neutron detector, 90% of the 10.622 0.002 neutron detections per second are consistent with a lunar source of epithermal and fast neutrons combined (E > 0.4 eV), with 3% due to lunar-sourced thermal neutron leakage into the detector (E < 0.4 eV), and background signal accounting for 7% of total detections. Background signal due to spacecraft-derived neutrons is substantial in the CSETN collimated detector system, accounting for 57% of the global average detection rate of 5.082 0.001 cps, greater than the 48% estimated from cruise-phase data. Lunar-sourced epithermal and fast neutrons account for 43% of detected neutrons, including neutrons in collimation as well as neutrons that penetrate the collimator wall to reach the detector. We estimate a lower limit of 17% of lunar-sourced neutrons detected by CSETN are epithermal neutrons in collimation (0.37 cps), with an upper limit estimate of 54 11% of lunar-sourced neutrons received in collimation, or 1.2 0.2 cps global average. The pole-to-equator contrast ratio inepithermal and high-energy epithermal neutron flux indicates that the average concentration of hydrogen in the polar regolith above 80 north or south latitude is ~105 ppmw (parts per million by weight), or 0.095 0.01 wt% water-equivalent hydrogen. Above 88 north or south, the concentration increases to ~140 ppmw, or 0.13 0.02 wt% water-equivalent hydrogen. The similar pattern of neutron flux suppression at both poles suggests that hydrogen concentration generally increases nearer the pole and is not closely associated with a specific feature such as Shackleton Crater at the lunar south pole that has no northern counterpart. Epithermal neutron flux decreases with increasing latitude outside the polar regions, consistent with surface hydration that increases with latitude if that hydration extends to ~13-40 cm into the surface.
Gaining a thorough understanding of biological systems requires building our knowledge about biological processes from the level of atoms and electrons, and up to whole organisms. Such comprehensive knowledge will allow for a predictive understanding of complex biological systems behavior. It will guide us in the design and development of novel therapeutics and vaccines to tackle existing health threats and to prepare for future pandemics, and it will provide information necessary to create new biomaterials and bio-inspired technologies through manipulation of biological macromolecules, their assemblies, single cells and even microorganisms. Reaching these goals will require a synergistic combination of multiple experimental techniques with molecular calculations and predictive simulations, and the design and development of new techniques and capabilities that bridge current knowledge and technology gaps. Neutron scattering provides unique information about the biomacromolecular structure and function and can play a major role in achieving these goals. A workshop was held to engage the scientific community in identifying pressing challenges in biochemistry, structural biology, enzymology and structure-guided drug design not solved with the current neutron scattering technologies or utilizing other structural biology techniques such as X-ray crystallography, NMR, and cryo-EM. The workshop brought together structural biology, biochemistry and computational experts, as well as early career researchers and students, creating a forum for discussing scientific advancement and collaboration. The workshop included a one-day satellite training workshop where graduate students and postdoctoral researchers were educated in the application of neutron crystallography and small-angle scattering in structural biology. Furthermore, the Instrument Scientific Advisory Board (ISAB) for the development of a macromolecular neutron diffractometer at ORNL’s Second Target Station was introduced at the workshop. The major outcome was that neutrons can provide atomic-level understanding of biomacromolecular structure, function and dynamics which is of paramount importance for addressing the identified challenges. Neutron crystallography, in particular, can resolve long-standing biochemical issues regarding enzyme function by delineating the underlying chemistry and can have a major impact on the design of small-molecule therapeutics, especially in combination with molecular computation (quantum chemistry and molecular dynamics simulations) and the emerging artificial intelligence (AI)-assisted drug design technologies. The unique properties of neutrons, including their high sensitivity to hydrogen and their non-destructive nature, make them ideal probes of biological matter. There is a palpable need in the scientific community to expand and enhance the impact of neutron sciences on biology. Neutron crystallography is the only structural biology method capable of determining positions of all hydrogen atoms in proteins, nucleic acids and their complexes at near-physiological temperatures and of unstable species at cryogenic temperatures. Moreover, neutron analysis is non-ionizing, non-destructive and does not perturb the structure or redox chemistry of active site metal centers and clusters in proteins, which can be invaluable for studying radiation-sensitive metalloprotein complexes. Further, neutron energies used in scattering applications are similar to atomic motions, permitting neutron spectroscopies to characterize the dynamics of biomacromolecules on the picosecond to microsecond timescales. The different sensitivities of neutrons to protium (H) and deuterium (D) isotopes of hydrogen allow enhanced visibility of specific parts of biological complexes through isotopic labeling. The impact of neutrons will be most powerful when neutron scattering is combined with complementary experimental techniques that use photons and electrons, and with high-performance computing. The interconnection and mutuality of the experimental and theoretical capabilities will drive discoveries in biological and health sciences to generate more complete picture of complex biological systems. The major limitation in the field of biological neutron crystallography has been signal-to-noise, demanding large samples that are difficult to produce for the majority of biomacromolecules and limiting the applicability of this technique in biological sciences. A neutron crystallography instrument at the Second Target Station will revolutionize biological science with neutrons by engaging a large scientific community of structural biologists, enabling successful neutron diffraction experiments from radically smaller biomacromolecular crystals, resolving unanswered biochemical questions, and meaningfully contributing to rational drug design. The meeting highlighted 10 grand challenges that will be addressed with this advanced capability over the next decade and beyond, and the recommendations required to help address them are given below.
Here, this paper details the conceptual design of a thermal-to-14-MeV neutron converter consisting of a mixture of lithium and deuterium in a blanket material. Such a device operates a two-step reaction, first generating tritons via thermal neutron absorption in the tritium breeding material, and in the second step, high-energy neutrons are produced either via deuterium-tritium fusion reaction or with tritium reacting with lithium. A thermal-to-14-MeV neutron converter significantly hardens the neutron spectrum by virtually removing thermal neutrons and adding a high-energy 14 MeV component to the neutron spectrum. While similar concepts have been previously proposed and tested in other reactors, the unique characteristics of the Advanced Test Reactor (ATR), namely its important thermal flux (up to $10^{15}$ n.cm$^{-2}$.s$^{-1}$) makes it markedly attractive for obtaining a very large fast neutron flux, usable for irradiation studies under neutron flux conditions prototypical of fusion reactors. The paper provides a description of a new computational scheme developed for handling the coupled neutron-triton transport mechanism using the Geant4 toolkit. Resulting neutron spectra and high-energy neutron yields are summarized for different irradiation positions and potential neutron breeder materials. Maximum predicted thermal-to-14-MeV neutron yields are on the order of $2.10^{-4}$, which is consistent with previous studies found in the literature. Thus, when placed inside the ATR, such a neutron converter will be providing the largest high-energy neutron source available for activation and irradiation studies of materials foreseen for use in fusion reactors. Future steps will involve qualifying the computational scheme using the ATR critical facility using activation foil measurements.
III-nitride wide bandgap semiconductors have contributed on the grandest scale to many technological advances in lighting, displays, and power electronics. Among III-nitrides, BN has another unique application as a solid-state neutron detector material because the isotope B-10 is among a few elements that have an unusually large interaction cross section with thermal neutrons. A record high thermal neutron detection efficiency of 60% has been achieved by B-10 enriched h-BN detectors of 100 μm in thickness in our group. However, direct detection of fast neutrons with energies above 1 MeV is highly challenging due to the extremely low interaction cross section of fast neutrons with matter. We report the successful attainment of 0.4 mm thick freestanding h-BN 4"-diameter wafers, which enabled the demonstration of h-BN fast neutron detectors capable of delivering a detection efficiency of 2.2% in response to a bare AmBe neutron source. Furthermore, it was shown that the energy information of incoming fast neutrons is retained in the neutron pulse-height spectra. A comparison of characteristics between h-BN fast and thermal neutron detectors is summarized. Neutron detectors are vital diagnostic instruments for nuclear and fusion reactor power and safety monitoring, oil field exploration, neutron imaging and therapy, as well as for plasma and material science research. With the outstanding attributes resulting from its ultrawide bandgap (UWBG), including the ability to operate at extreme conditions of high power, voltage, and temperature, the availability of h-BN UWBG semiconductor detectors with the capability of simultaneously detecting thermal and fast neutrons with high efficiencies is expected to open unprecedented applications that are not possible to attain by any other types of neutron detectors.
For enhancing the effectiveness of nonproliferation efforts in neutron detection, most portable instruments rely on 6 Li scintillators, 10 B-based detectors, or gas-filled 3 He proportional counters. Additionally, gamma-ray detectors based on scintillators and semiconductors are often employed for search applications to find radioactive material in the field. These systems typically include dedicated detectors along with separate high voltage supplies and processing electronics for the gamma-ray and neutron detectors. Ideally, a portable radiation detection system should be lightweight, compact, and cost-effective. In the field, scintillators can serve a dual purpose: (1) detecting gamma-rays and (2) detecting neutrons. Gamma-ray detection with scintillators is based on the interaction of gamma-rays within the scintillating material, whereas neutron detection depends indirectly on neutron capture events. These capture events generate conversion electrons and gamma-rays, which can interact with the scintillator. For enhancing neutron capture, the scintillator can be surrounded by neutron absorber materials with a high neutron cross section. The resulting secondary electrons and gamma-rays from neutron interactions, depending on the absorber material used, can then be analyzed to detect the presence of neutron sources. Similarly, semiconductor-based detectors can be employed along with neutron absorbers as liners for neutron detection. 158 Gd has a significantly larger neutron cross section than 3 He, commonly used in gas-filled proportional counters, as shown in Figure 1. For thermal (0.025 eV) neutrons, the absorption cross section of 158 Gd is 10,000 times greater than that of 3 He (refer to Figure 1). This feature makes naturally occurring gadolinium, which consists of 24.8% 158 Gd, a promising neutron absorber material for use in combination with gamma-ray detectors–yielding a hybrid detector–for neutron detection.
This paper summarizes neutron dosimetry measurements made by the USF Physics Research Laboratory aboard US and Russian LEO spacecraft over the past 20 years using two types of passive detector. Thermal/resonance neutron detectors exploiting the 6Li(n,T) alpha reaction were used to measure neutrons of energies <1 MeV. Fission foil neutron detectors were used to measure neutrons of energies above 1 MeV. While originally analysed in terms of dose equivalent using the NCRP-38 definition of quality factor, for the purposes of this paper the measured neutron data have been reanalyzed and are presented in terms of ambient dose equivalent. Dose equivalent rate for neutrons <1 MeV ranged from 0.80 microSv/d on the low altitude, low inclination STS-41B mission to 22.0 microSv/d measured in the Shuttle's cargo bay on the highly inclined STS-51F Spacelab-2 mission. In one particular instance a detector embedded within a large hydrogenous mass on STS-61 (in the ECT experiment) measured 34.6 microSv/d. Dose equivalent rate measurements of neutrons >1 MeV ranged from 4.5 microSv/d on the low altitude STS-3 mission to 172 microSv/d on the ~6 year LDEF mission. Thermal neutrons (<0.3 eV) were observed to make a negligible contribution to neutron dose equivalent in all cases. The major fraction of neutron dose equivalent was found to be from neutrons >1 MeV and, on LDEF, neutrons >1 MeV are responsible for over 98% of the total neutron dose equivalent. Estimates of the neutron contribution to the total dose equivalent are somewhat lower than model estimates, ranging from 5.7% at a location under low shielding on LDEF to 18.4% on the highly inclined (82.3 degrees) Biocosmos-2044 mission. c2001 Elsevier Science Ltd. All rights reserved.
This work proposes a preliminary neutron dose rate estimation method for a neutron multiplicity detector through measurement- and simulation-based analyses. Uncharacterized neutron-emitting sources may be encountered in situations such as nuclear emergency response, safeguards, and treaty verification. These circumstances may present irradiation risk to personnel conducting field assay, search, and characterization measurements. It is therefore of interest to provide a field neutron dosimetry capability with the existing neutron multiplicity counting (NMC) capabilities. To date, no commercially-available neutron detection systems are capable of both accurate NMC and real-time neutron dosimetry. This work will focus on estimating dose rate using input from a single fielded NMC called the MC-15. The energy-dependent neutron detection efficiency response of the MC-15 was quantified in monoenergetic neutron simulations and evaluated in response to two neutron-emitting sources and to a polyethylene-moderated source. The results were compared to existing neutron dosimeters and established the proof of concept for further investigation of the MC-15 for dose estimation. Measurement results were also replicated in simulations; additional simulations were then conducted to expand upon the limited empirical data. The initial empirical results provided a conversion factor appropriate for use when measuring 252 Cf neutrons that is independent of polyethylene shielding presence and thickness. The simulated data sets were then used to evaluate a fit equation allowing estimation of the neutron dose rate for less restricted geometric configurations and dependent only on the distance between the source and the detector. Additionally, the energy dependence of the efficiency response indicates that further empirical evaluations could provide energy-dependent conversion factors for broader neutron dosimetry capabilities with a wider range of neutron-emitting sources.
Manned spacecraft venturing beyond the Earth’s Van Allen Belts will be subjected to high levels of radiation from both energetic particles emanating from the sun and from galactic atomic events, such as supernovae. The metal shell of a spacecraft offers some protection from gamma radiation and high energy particles originating from both the sun and cosmic sources. The interaction of these high energy particles and radiation with the spacecraft hull create secondary radiation and neutrons, additional hazards for astronauts and electronic systems. Shielding of neutrons is the most challenging of the high energy radiation, since neutrons have zero charge and are least affected by electrical fields, magnetic fields, and atomic forces. Previous studies showed that polyethylene is an effective neutron shielding material, due to its high hydrogen content. High energy neutrons are slowed to thermal neutrons through multiple collisions with the hydrogen atoms, increasing the effectiveness of neutron capture by boron-10 atoms. This study discusses the fabrication and testing of polyvinyl alcohol (PVOH) samples as a neutron shielding material, with comparison to medium density polyethylene (MDPE) composite samples to be used for neutron shielding for spacecraft. PVOH, an aqueous polymer, was chosen for hydrogen content and for enabling the use of organic reinforcement such as cellulose for secondary structural composites. OLTARIS (On-Line Tool for the Assessment of Radiation in Space) was used for radiation shielding simulation and compared with experimental data. Modeling indicates that the most effective shielding from radiation was in an aluminum layer backed by a polymer layer, either MDPE or PVOH. Cross-linked PVOH was also included in the OLTARIS modeling. All 3 polymer cases showed shielding improvement over aluminum alone, with similar dose equivalent reduction for galactic cosmic radiation(GCR)and for radiation from a solar particle event (SPE). Fourier Transform Infrared (FTIR) Spectroscopy was used to confirm the cross-linking in the PVOH sample and to determine the uniformity through the thickness. PVOH, cross-linked PVOH, and MDPE samples were tested for neutron shielding effectiveness using a 1 curie Americium-Beryllium neutron source. Test results indicated the most shielding in the cross-linked PVOH, followed by the pristine PVOH, and MDPE. Neutron testing suggests that polyvinyl alcohol is a good alternative to polyethylene for neutron shielding. The neutron shielding materials, PVOH and cross-linked PVOH developed under this research will enable the safe operation of spacecraft beyond the Earth’s protective Van Allen Radiation Belts. It will be crucial for NASA’s manned missions to the Moon or Mars to protect the health of astronauts and equipment from the harmful effects of excessive radiation.
Neutron time-of-flight (nTOF) spectrometers are essential instruments for measuring and evaluating the performance of inertial confinement fusion implosions. The neutron spectrometers utilized for the OMEGA laser include two liquid-based scintillators, each consisting of a large volume filled with xylene that is coupled to four photomultiplier tubes. Analysis of the signal from these detectors requires detailed knowledge of the scintillator’s light output, which is needed to fit the nTOF spectrum, from which the neutron energy spectrum is informed. The light output is nonlinearly proportional to the neutron energy, which, in turn, affects the interpretation of the neutron energy spectrum from a TOF signal. A recent campaign on OMEGA was performed to calibrate the xylene detectors and infer the shape of the light-output curve. The campaign utilized materials with increasing Z placed in the OMEGA target chamber to initiate scattering events with the 14 MeV fusion neutrons. This process leads to the production of backscatter neutrons of varying energies that appear as peaks in the nTOF data. Simulations using a neutron transport code were combined with the measured deuterium–tritium neutron yields to calculate the expected backscattered neutron yields from the well-known scattering cross sections of each material. Furthermore, the neutron-energy dependent light output of the scintillator inferred from the experiment is compared to the light-output curve simulated with a neutron transport code for the following neutron energies: 1.5, 2.5, 6, and 14 MeV.
Project Summary Company: Adelphi Technology, Inc. Title: Aberration-corrected High Frequency RF Flipper for High-Resolution Neutron Spectroscopy PI: Dr. Jay Theodore Cremer Topic: C55-11 Enhancement of Scattering Instrumentation Technology Used at Pulsed and Continuous Sources Subtopic: d. Other Statement of the problem or situation that is being addressed. The quest to understand heterogeneous and hierarchical materials is gathering momentum, as described in a 2015 report by the Basic Energy Sciences Advisory Committee on Challenges at the Frontiers of Matter and Energy. For the past 40 years a technique called neutron spin echo (NSE) has been used to probe molecular motions in such non-crystalline materials over time scales from 10’s of picoseconds to 100’s of nanoseconds. The method has provided unique information about the dynamics of soft heterogeneous materials, including confirmation of the de Gennes model of polymer reptation and quantitative measurement of bending constants of biologically relevant lipid membranes. However, scientists continue to clamor for even higher resolution than NSE can provide. Biomaterials, polymers, glasses, and artificially nanostructured materials all manifest slow molecular motions because of weak or competing interactions between subunits and are amenable to study with neutrons, provided sufficiently long dynamical correlation times can be achieved. All these materials have important applications to advanced technologies so understanding them is key to technological progress. General statement of how this problem is being addressed. We will address the need for high-resolution neutron spectroscopy by using a technique called Neutron Resonance Spin Echo (NRSE). While similar to NSE in many respects, this method has the potential to exceed the NSE capabilities, if 2 technical hurdles can be overcome. The major impediments to successful high-resolution NRSE are the availability of two technologies: a very high frequency, efficient, radiofrequency (rf) flipper for neutrons and a method to correct certain magnetic aberrations. Based on previous STTR support and follow-on research we have developed a suitable rf flipper and we have invented a method to correct the magnetic aberrations. Both technologies need refinement to make them suitable for implementation at a neutron source such as the Oak Ridge National Laboratory nuclear reactor. In this proposal we seek to perfect the two technologies and to combine them into a single, operationally convenient device. Commercial Applications and Other Benefits In view of the increasing demand for the unique scientific information that high resolution neutron spectroscopy can provide, we expect several major instrumentation upgrades at both U.S. and foreign neutron centers will require make use of the NRSE method over the coming decade, creating a market for the devices we will design. These components will enhance scientists’ abilities to probe the time dependence of density fluctuations in a wide range of hierarchical and heterogeneous materials many of which are vital to existing and future technologies. Key Words – Polarized Neutrons, Neutron Spin Echo, Neutron Scattering, advanced materials. Summary for Members of Congress Neutron beams are a powerful materials-science probe that provide unique information about the structure of matter. The proposed devices will accelerate scientific discoveries required to achieve national goals for new technological materials.