Search NASA⌕ Search

SEARCH · Search NASA

Results for “Nitrogen saturation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

A Generalized Multi-Phase Framework for Modeling Cavitation in Cryogenic Fluids

A generalized multi-phase formulation for cavitation in fluids operating at temperatures elevated relative to their critical temperatures is presented. The thermal effects and the accompanying property variations due to phase change are modeled rigorously. Thermal equilibrium is assumed and fluid thermodynamic properties are specified along the saturation line using the NIST-12 databank. Fundamental changes in the physical characteristics of the cavity when thermal effects become pronounced are identified; the cavity becomes more porous, the interface less distinct, and has increased entrainment when temperature variations are present. Quantitative estimates of temperature and pressure depressions in both liquid nitrogen and liquid hydrogen were computed and compared with experimental data of Hord for hydrofoils. Excellent estimates of the leading edge temperature and pressure depression were obtained while the comparisons in the cavity closure region were reasonable. Liquid nitrogen cavities were consistently found to be in thermal equilibrium while liquid hydrogen cavities exhibited small, but distinct, non-equilibrium effects.

Dorney, Dan↗

Measurements of a supersonic velocity in a nitrogen flow using inverse Raman spectroscopy

Results are presented for supersonic molecular flow-velocity measurements using inverse Raman spectroscopy. The flow velocity, temperature, and density of flowing N2 molecules are measured because of potential wind-tunnel applications. Uncertainties of less than 5% are found for the velocity measurements, while the uncertainties are about 10% for the temperature and density measurements. The laser probe is stabilized by using I2 fluorescence, and I2 saturated absorption is utilized to provide an absolute frequency reference. Differential detection techniques are employed to reduce detection noise.

Herring, G. C.↗

Dry matter and nitrogen accumulation are not affected by superoptimal concentration of ammonium in flowing solution culture with pH control

While it is known that superoptimal concentrations of the nitrate (NO3-) ion in solution culture do not increase NO3- uptake or dry matter accumulation, the same is not known for the ammonium (NH4+) ion. An experiment was conducted utilizing flowing solution culture with pH control to investigate the influence of superoptimal NH4+ concentrations on dry matter, nitrogen (N), potassium (K), calcium (Ca), and magnesium (Mg) accumulation by nonnodulated soybean plants. Increasing the NH4+ concentration in solution from 1 to 10 mM did not affect dry matter or N accumulation. Accumulations of K, Ca, and Mg were slightly decreased with increased NH4+ concentration. The NH4+ uptake system, which is saturated at less than 1mM NH4+, is able to regulate uptake of NH4+ at concentrations as high as 10 mM.

NASA Discipline Life Support Systems↗

Thermodynamic Properties of Nitrogen Including Liquid and Vapor Phases from 63K to 2000K with Pressures to 10,000 Bar

Tables of thermodynamic properties of nitrogen are presented for the liquid and vapor phases for temperatures from the freezing line to 2000K and pressures to 10,000 bar. The tables include values of density, internal energy, enthalpy, entropy, isochoric heat capacity, isobaric heat capacity velocity of sound, the isotherm derivative, and the isochor derivative. The thermodynamic property tables are based on an equation of state, P=P (p,T), which accurately represents liquid and gaseous nitrogen for the range of pressures and temperatures covered by the tables. Comparisons of property values calculated from the equation of state with measured values for P-p-T, heat capacity, enthalpy, latent heat, and velocity of sound are included to illustrate the agreement between the experimental data and the tables of properties presented here. The coefficients of the equation of state were determined by a weighted least squares fit to selected P-p-T data and, simultaneously, to isochoric heat capacity data determined by corresponding states analysis from oxygen data, and to data which define the phase equilibrium criteria for the saturated liquid and the saturated vapor. The vapor pressure equation, melting curve equation, and an equation to represent the ideal gas heat capacity are also presented. Estimates of the accuracy of the equation of state, the vapor pressure equation, and the ideal gas heat capacity equation are given. The equation of state, derivatives of the equation, and the integral functions for calculating derived thermodynamic properties are included.

Thermodynamic properties↗

Evolution and use of combined mechanical and thermal codes for cryogenic turbopump bearings

Shaft bearing system analysis codes were developed, improved, and used to investigate Space Shuttle Main Engine (SSME) Liquid Oxygen (LOX) turbopump bearing problems, and to support the Marshall Space Flight Center Bearing and Seal Materials Test (BSMT) program. Thermal network modeling uses the SINDA thermal code, and the modeling of bearing quasi-dynamic characteristics uses the SHABERTH bearing/shaft code. These codes are solved concurrently for a bearing/shaft system using software developed for this purpose. Simulation of the SSME LOX turbopump turbine and pump end bearings and the MSFC BSMT operating in liquid nitrogen (LN sub 2) and LOX was done. The thermal network models include the bearing components, bearing carriers, shaft, housing, frictional heat, and viscous fluid energy. A cage model was included to account for heat generation between the cage and rolling elements. Since most bearing surfaces operate at temperatures well above the coolant saturation temperature, and move at high speed relative to the coolant, forced convection boiling is the dominant mechanism for heat removal. Improved modeling of forced convection film boiling was incorporated to take into account the local vapor generation at the high temperature surfaces. Rearing preloads in the pump and tester are provided by preload springs. As bearing operating clearances and contact angles change due to thermal effects and loading, the bearing preload changes with these varying conditions. These characteristics were modeled and are included in the overall system models. Results from these models indicate an operational limit which, if exceeded, predicts a thermal excursion.

Cody, Joe C.↗

Solid-State Thermodynamic Vent System (STVS) for Control of Cryogenic Propellants

A Solid-State Thermodynamic Vent System (STVS) is a novel Cryogenic Fluid Management (CFM) technology for spacecraft cryogenic propellant tanks that may reduce boiloff while providing greater control over the propellant condition. By exploiting the vacuum-induced cryocooling (VIC) potential of cryogen-saturated silica aerogel material, an internal STVS heat exchanger (HX) can expel some sacrificial cryogenic propellant to the vacuum of space to produce cooling within the storage tank. This cooling is transferred directly to the stored fluid, thereby reducing boiloff and increasing hold times. Testing proved the effectiveness of the concept by reducing the liquid nitrogen (LN 2 ) boiloff rate and tank pressure by roughly 70% and 77%, respectively, during a single pump-down cycle, which sacrificed around 1.8 kg of propellant.

Cryogenic Fluid↗

Alpha-Particle Gas-Pressure Sensor

An approximate model was developed to establish design curves for the saturation region and a more complete model developed to characterize the current-voltage curves for an alpha-particle pressure sensor. A simple two-parameter current-voltage expression was developed to describe the dependence of the ion current on pressure. The parameters are the saturation-current pressure coefficient and mu/D, the ion mobility/diffusion coefficient. The sensor is useful in the pressure range between 0.1 and 1000 mb using a 1 - mu Ci(241) Am source. Experimental results, taken between 1 and up to 200 mb, show the sensor operates with an anode voltage of 5 V and a sensitivity of 20 fA/mb in nitrogen.

Buehler, M. C.↗

Investigation of laser-induced iodine fluorescence for the measurement of density in compressible flows

Laser induced fluorescence is an attractive nonintrusive approach for measuring molecular number density in compressible flows although this technique does not produce a signal that is directly related to the number density. Saturation and frequency detuned excitation are explored as means for minimizing the quenching effect using iodine as the molecular system because of its convenient absorption spectrum. Saturation experiments indicate that with available continuous wave laser sources of Gaussian transverse intensity distribution only partial saturation could be achieved in iodine at the pressures of interest in gas dynamics. Using a fluorescence lineshape theory, it is shown that for sufficiently large detuning of a narrow bandwidth laser from a molecular transition, the quenching can be cancelled by collisional broadening over a large range of pressures and temperatures. Experimental data obtained in a Mach 4.3 underexpanded jet of nitrogen seeded with iodine for various single mode argon laser detunings from a strong iodine transition at 5145 A are discussed.

Mcdaniel, J. C., Jr.↗

Liquid Nitrogen (Oxygen Simulant) Thermodynamic Vent System Test Data Analysis

In designing systems for the long-term storage of cryogens in low-gravity (space) environments, one must consider the effects of thermal stratification on tank pressure that will occur due to environmental heat leaks. During low-gravity operations, a Thermodynamic Vent System (TVS) concept is expected to maintain tank pressure without propellant resettling. A series of TVS tests was conducted at NASA Marshall Space Flight Center (MSFC) using liquid nitrogen (LN2) as a liquid oxygen (LO2) simulant. The tests were performed at tank til1 levels of 90%, 50%, and 25%, and with a specified tank pressure control band. A transient one-dimensional TVS performance program is used to analyze and correlate the test data for all three fill levels. Predictions and comparisons of ullage pressure and temperature and bulk liquid saturation pressure and temperature with test data are presented.

Hedayat, A.↗

Tholins: Can They Provide a Substrate, Carbon and Nitrogen for Plant Production?

Tholin is a word coined to describe the entire class of complex organic solids produced in laboratory experiments where pre-biotic gaseous chemicals are subject to bombardment by high energy. The atomic composition of Titan tholin produced from 10 percent CH4 and 90 percent N2 in a simulation of Titan atmosphere irradiated by charged particles trapped in the magnetosphere of Saturn gave 67 percent C and 33 percent N. Hydrolysis of Titan tholin with 6N HCl produced a racemic mixture of biological and non-biological amino acids that was confirmed by GC/MS. Other tholins, that revealed the presence of amino acids, were UV tholin produced under possible primitive Earth conditions by irradiation of a mixture of gases (CH4, C2H6, NH3, H2S and liquid H2O) with long-wavelength ultraviolet light, representing the most abundant useful energy source for prebiological organic synthesis; Spark tholin in a crude simulation of Jupiter atmosphere using electrical discharge through a mixture of CH4, NH3, and H2O vapor. Pyrolytic GC/MS of Titan tholin produced more than one hundred organic compounds including saturated and unsaturated aliphatic hydrocarbons, substituted polycyclic aromatics, nitriles, amines, pyrroles, pyrazines, pyridines, pyrimidines, and the purine, adenine. Similar rich pyrolytic products were obtained with UV as well as Spark tholins. A range of two to four ring PAHs (Polycyclic Aromatic Hydrocarbons) in Spark as well as Titan tholins, some with one to four alkylation sites, were identified by two-step laser desorption/multiphoton ionization mass spectrometry and also confirmed by the synchronous fluorescence technique. Previous studies have demonstrated the potential for use of tholins as a source of carbon and energy by microbes. This paper describes studies that evaluate the potential for using different types of tholins as (a) a substrate for growing plants and (b) a source of carbon and nitrogen for plants. The data are interpreted in terms of the potential for using such tholins to grow plants for food in extraterrestrial habitats and also to speculate on the possibilities of abiotic evolution of plants.

Wignarajah, Kanapathipillai↗

The photophysics of monomeric bacteriochlorophylls c and d and their derivatives: properties of the triplet state and singlet oxygen photogeneration and quenching

Measurements of pigment triplet-triplet absorption, pigment phosphorescence and photosensitized singlet oxygen luminescence were carried out on solutions containing monomeric bacteriochlorophylls (Bchl) c and d, isolated from green photosynthetic bacteria, and their magnesium-free and farnesyl-free analogs. The energies of the pigment triplet states fell in the range 1.29-1.34 eV. The triplet lifetimes in aerobic solutions were 200-250 ns; they increased to 280 +/- 70 microseconds after nitrogen purging in liquid solutions and to 0.7-2.1 ms in a solid matrix at ambient or liquid nitrogen temperatures. Rate constants for quenching of the pigment triplet state by oxygen were (2.0-2.5) x 10(9) M-1 s-1, which is close to 1/9 of the rate constant for diffusion-controlled reactions. This quenching was accompanied by singlet oxygen formation. The quantum yields for the triplet state formation and singlet oxygen production were 55-75% in air-saturated solutions. Singlet oxygen quenching by ground-state pigment molecules was observed. Quenching was the most efficient for magnesium-containing pigments, kq = (0.31-1.2) x 10(9) M-1 s-1. It is caused mainly by a physical process of singlet oxygen (1O2) deactivation. Thus, Bchl c and d and their derivatives, as well as chlorophyll and Bchl a, combine a high efficiency of singlet oxygen production with the ability to protect photochemical and photobiological systems against damage by singlet oxygen.

NASA Discipline Number 52-30↗

Liquid Nitrogen (Oxygen Simulent) Thermodynamic Venting System Test Data Analysis

In designing systems for the long-term storage of cryogens in low gravity space environments, one must consider the effects of thermal stratification on excessive tank pressure that will occur due to environmental heat leakage. During low gravity operations, a Thermodynamic Venting System (TVS) concept is expected to maintain tank pressure without propellant resettling. The TVS consists of a recirculation pump, Joule-Thomson (J-T) expansion valve, and a parallel flow concentric tube heat exchanger combined with a longitudinal spray bar. Using a small amount of liquid extracted by the pump and passing it though the J-T valve, then through the heat exchanger, the bulk liquid and ullage are cooled, resulting in lower tank pressure. A series of TVS tests were conducted at the Marshall Space Flight Center using liquid nitrogen as a liquid oxygen simulant. The tests were performed at fill levels of 90%, 50%, and 25% with gaseous nitrogen and helium pressurants, and with a tank pressure control band of 7 kPa. A transient one-dimensional model of the TVS is used to analyze the data. The code is comprised of four models for the heat exchanger, the spray manifold and injector tubes, the recirculation pump, and the tank. The TVS model predicted ullage pressure and temperature and bulk liquid saturation pressure and temperature are compared with data. Details of predictions and comparisons with test data regarding pressure rise and collapse rates will be presented in the final paper.

Hedayat, A.↗

Shallow n(+) diffusion into InP by an open-tube diffusion technique

Very shallow n(+) layers have been obtained in InP by using gallium sulfide as a source for sulfur diffusion, and chemically vapor-deposited SiO2 as a cap. Diffusions were carried out from 585 to 725 C in an open-tube system with a nitrogen ambient. The doping profile of sulfur in InP is estimated to be of the complementary error function type with a surface concentration of 5.6 x 10 to the 18th/cc and a diffusion constant of 1.1 x 10 to the -14th sq cm/s at 670 C. Diodes made on n(+)-p junctions obtained by this diffusion technique show ideality factors close to unity and saturation current densities as low as 3.4 x 10 to the -15th A/sq cm, signifying the presence of a defect-free junction. These diffusions, with junction depths in the 400-700 A range, are ideal for solar cell applications.

Ghandhi, Sorab K.↗

Dehydration and Denitrification in the Arctic Polar Vortex During the 1995-1996 Winter

Dehydration of more than 0.5 ppmv water was observed between 18 and 19 km (theta = 450-465 K) at the edge of the Arctic polar vortex on February 1, 1996. More than half the reactive nitrogen (NOy) had also been removed, with layers of enhanced NOy at lower altitudes. Back trajectory calculations show that air parcels sampled inside the vortex had experienced temperatures as low as 188 K within the previous 12 days, consistent with a small amount of dehydration. The depth of the dehydrated layer (approx. 1 km) and the fact that trajectories passed through the region of ice saturation in one day imply selective growth of a small fraction of particles to sizes large enough (>10 micrometers) to be irreversibly removed on this timescale. Over 25% of the Arctic vortex in a 20-30 K range of theta is estimated to have been dehydrated in this event.

Hintsa, E. J.↗

Ice saturation at the tropopause observed from the ER-2 aircraft

Ice saturation at or just above the tropopause was frequently observed during the ER-2 vertical profiles over Stavanger (59 deg N) during the Airborne Arctic Stratospheric Expedition (AASE). On occasion, ice saturation extended as much as 500 m above the tropopause. Saturation was not observed over Punta Arenas (53 deg S) during the Airborne Antarctic Ozone Experiment. Saturation extending just above the tropopause was observed at Moffett Field (38 deg N) in winter but not in summer. The top of a thick cirrus layer at the tropopause will be very strongly cooled, and a thin cloud layer at the tropopause will either be strongly heated or cooled depending on the presence of lower level clouds. Some ER-2 data suggests removal of water and nitrogen species from the tropopause.

Murphy, D. M.↗

Investigation of two and three parameter equations of state for cryogenic fluids

Two-phase flows are a common occurrence in cryogenic engines and an accurate evaluation of the heat-transfer coefficient in two-phase flow is of significant importance in their analysis and design. The thermodynamic equation of state plays a key role in calculating the heat transfer coefficient which is a function of thermodynamic and thermophysical properties. An investigation has been performed to study the performance of two- and three-parameter equations of state to calculate the compressibility factor of cryogenic fluids along the saturation loci. The two-parameter equations considered here are van der Waals and Redlich-Kwong equations of state. The three-parameter equation represented here is the generalized Benedict-Webb-Rubin (BWR) equation of Lee and Kesler. Results have been compared with the modified BWR equation of Bender and the extended BWR equations of Stewart. Seven cryogenic fluids have been tested; oxygen, hydrogen, helium, nitrogen, argon, neon, and air. The performance of the generalized BWR equation is poor for hydrogen and helium. The van der Waals equation is found to be inaccurate for air near the critical point. For helium, all three equations of state become inaccurate near the critical point.

Jenkins, Susan L.↗

Dehydration and Denitrification in the Arctic Polar Vortex During the 1995-1996 Winter

Dehydration of more than 0.5 ppmv water was observed between 18 and 19 km (0-450-465 K) at the edge of the Arctic polar vortex on February 1, 1996. More than half the reactive nitrogen (NO(y)) had also been removed, with layers of enhanced NO(y) at lower altitudes. Back trajectory calculations show that air parcels sampled inside the vortex had experienced temperatures as low as 188 K within the previous 12 days, consistent with a small amount of dehydration. The depth of the dehydrated layer (approximately 1 km) and the fact that trajectories passed through the region of ice saturation in one day imply selective growth of a small fraction of particles to sizes large enough (>10 microns) to be irreversibly removed on this timescale. Over 25% of the Arctic vortex in a 20-30 K range of 0 is estimated to have been dehydrated in this event.

Hintsa, E. J.↗

Dehydration and Denitrification in the Arctic Polar Vortex During the 1995-1996 Winter

Dehydration of more than 0.5 ppmv water was observed between 18 and 19 km (theta approximately 450-465 K) at the edge of the Arctic polar vortex on February 1, 1996. More than half the reactive nitrogen (NO(y)) had also been removed, with layers of enhanced NO(y) at lower altitudes. Back trajectory calculations show that air parcels sampled inside the vortex had experienced temperatures as low as 188 K within the previous 12 days, consistent with a small amount of dehydration. The depth of the dehydrated layer (approximately 1 km) and the fact that trajectories passed through the region of ice saturation in one day imply selective growth of a small fraction of particles to sizes large enough (>10 micrometers) to be irreversibly removed on this timescale. Over 25% of the Arctic vortex in a 20-30 K range Transport of theta is estimated to have been dehydrated in this event.

Hintsa, E. J.↗