Search NASA⌕ Search

SEARCH · Search NASA

Results for “Noise deconvolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Development of a Microphone Phased Array Capability for the Langley 14- by 22-Foot Subsonic Tunnel

A new aeroacoustic measurement capability has been developed for use in open-jet testing in the NASA Langley 14- by 22-Foot Subsonic Tunnel (14x22 tunnel). A suite of instruments has been developed to characterize noise source strengths, locations, and directivity for both semi-span and full-span test articles in the facility. The primary instrument of the suite is a fully traversable microphone phased array for identification of noise source locations and strengths on models. The array can be mounted in the ceiling or on either side of the facility test section to accommodate various test article configurations. Complementing the phased array is an ensemble of streamwise traversing microphones that can be placed around the test section at defined locations to conduct noise source directivity studies along both flyover and sideline axes. A customized data acquisition system has been developed for the instrumentation suite that allows for command and control of all aspects of the array and microphone hardware, and is coupled with a comprehensive data reduction system to generate information in near real time. This information includes such items as time histories and spectral data for individual microphones and groups of microphones, contour presentations of noise source locations and strengths, and hemispherical directivity data. The data acquisition system integrates with the 14x22 tunnel data system to allow real time capture of facility parameters during acquisition of microphone data. The design of the phased array system has been vetted via a theoretical performance analysis based on conventional monopole beamforming and DAMAS deconvolution. The performance analysis provides the ability to compute figures of merit for the array as well as characterize factors such as beamwidths, sidelobe levels, and source discrimination for the types of noise sources anticipated in the 14x22 tunnel. The full paper will summarize in detail the design of the instrumentation suite, the construction of the hardware system, and the results of the performance analysis. Although the instrumentation suite is designed to characterize noise for a variety of test articles in the 14x22 tunnel, this paper will concentrate on description of the instruments for two specific test campaigns in the facility, namely a full-span NASA Hybrid Wing Body (HWB) model entry and a semi-span Gulfstream aircraft model entry, tested in the facility in the winter of 2012 and spring of 2013, respectively.

Humphreys, William M.↗

Investigation of Twin Jet Aeroacoustic Properties in the Presence of a Hybrid Wing Body Shield

In preparation for upcoming wind tunnel acoustic experiments of a Hybrid Wing Body (HWB) vehicle with two jet engine simulator units, a series of twin jet aeroacoustic investigations were conducted leading to increased understanding and risk mitigation. A previously existing twin jet nozzle system and a fabricated HWB aft deck fuselage are combined for a 1.9% model scale study of jet nozzle spacing and jet cant angle effects, elevon deflection into the jet plume, and acoustic shielding by the fuselage body. Linear and phased array microphone measurements are made, and data processing includes the use of DAMAS (Deconvolution Approach for the Mapping of Acoustic Sources). Closely-spaced twin jets with a 5 inward cant angle exhibit reduced noise levels compared to their parallel flow counterparts at similar and larger nozzle spacings. A 40 elevon deflection into the twin jet plume, which is required for HWB ground rotation, can significantly increase upstream noise levels (more than 5 dB OASPL) with only minimal increases in the downstream direction. Lastly, DAMAS processing can successfully measure the noise source distribution of multiple shielded jet sources.

Doty, Michael J.↗

Quantitative analysis of hard X-ray 'footpoint' flares observed by the solar maximum mission

Amplifier gain and collimator hole size variations across the field of view, amplifier/filter efficiency, variations in effective collimator hole size and angular response with photon energy, dead-time, and hard X-ray plate transmission, are among the factors for which instrumental corrections have to be incorporated to effect reliable correction and deconvolution of images from the SMM satellite's Hard X-ray Imaging Spectrometer (HXIS). Attention is given to the substantial Poisson noise in these energy bands. The maximum entropy deconvolution/correction routine developed for establishing the spatial structure reliably inferrable from HXIS data is presented, together with the results of the application of this routine to the three impulsive flares reported by Duijemian et al. (1982) from April 10, May 21, and November 5, 1980.

Mackinnon, A. L.↗

Infrared Speckle Interferometry with 2-D Arrays

We describe results from a program of speckle interferometry with two-dimensional infrared array detectors. Analysis of observations of eta Carinae made with 58 x 62 InSb detector are discussed. The data have been analyzed with both the Labeyrie autocorrelation, a deconvolution of shift-and-add data, and a phase restoration process. Development of a new camera based on a much lower noise HgCdTe detector will lead to a significant improvement i limiting magnitude for IR speckle interferometry.

Harvey, P. M.↗

Optimising the processing and storage of visibilities using lossy compression

The next-generation radio astronomy instruments are providing a massive increase in sensitivity and coverage, largely through increasing the number of stations in the array and the frequency span sampled. The two primary problems encountered when processing the resultant avalanche of data are the need for abundant storage and the constraints imposed by I/O, as I/O bandwidths drop significantly on cold storage. An example of this is the data deluge expected from the SKA Telescopes of more than 60 PB per day, all to be stored on the buffer filesystem. While compressing the data is an obvious solution, the impacts on the final data products are hard to predict. In this paper, we chose an error-controlled compressor – MGARD – and applied it to simulated SKA-Mid and real pathfinder visibility data, in noise-free and noise-dominated regimes. As the data have an implicit error level in the system temperature, using an error bound in compression provides a natural metric for compression. MGARD ensures the compression incurred errors adhere to the user-prescribed tolerance. To measure the degradation of images reconstructed using the lossy compressed data, we proposed a list of diagnostic measures, exploring the trade-off between these error bounds and the corresponding compression ratios, as well as the impact on science quality derived from the lossy compressed data products through a series of experiments. We studied the global and local impacts on the output images for continuum and spectral line examples. We found relative error bounds of as much as 10%, which provide compression ratios of about 20, have a limited impact on the continuum imaging as the increased noise is less than the image RMS, whereas a 1% error bound (compression ratio of 8) introduces an increase in noise of about an order of magnitude less than the image RMS. For extremely sensitive observations and for very precious data, we would recommend a 0.1% error bound with compression ratios of about 4. These have noise impacts two orders of magnitude less than the image RMS levels. At these levels, the limits are due to instabilities in the deconvolution methods. We compared the results to the alternative compression tool DYSCO, in both the impacts on the images and in the relative flexibility. MGARD provides better compression for similar error bounds and has a host of potentially powerful additional features.

Techniques: interferometric↗

Point-spread Function Deconvolution of the IFU Data and Restoration of Galaxy Stellar Kinematics

We present a performance test of the point-spread function (PSF) deconvolution algorithm applied to astronomical integral field unit (IFU) spectroscopy data for restoration of galaxy kinematics. We deconvolve the IFU data by applying the Lucy–Richardson algorithm to the 2D image slice at each wavelength. We demonstrate that the algorithm can effectively recover the true stellar kinematics of the galaxy, by using mock IFU data with a diverse combination of surface brightness profile, signal-to-noise ratio, line-of-sight geometry, and line-of-sight velocity distribution (LOSVD). In addition, we show that the proxy of the spin parameter ${\lambda }_{{R}_{e}}$ can be accurately measured from the deconvolved IFU data. We apply the deconvolution algorithm to the actual SDSS-IV MaNGA IFU survey data. The 2D LOSVD, geometry, and ${\lambda }_{{R}_{e}}$ measured from the deconvolved MaNGA IFU data exhibit noticeable differences compared to the ones measured from the original IFU data. The method can be applied to any other regular-grid IFU data to extract the PSF-deconvolved spatial information.

79 ASTRONOMY AND ASTROPHYSICS↗

Accurate, Sensitive, and Precise Multiplexed Proteomics Using the Complement Reporter Ion Cluster

We present that quantitative analysis of proteomes across multiple time points, organelles, and perturbations is essential for understanding both fundamental biology and disease states. The development of isobaric tags (e.g. TMT) have enabled the simultaneous measurement of peptide abundances across several different conditions. These multiplexed approaches are promising in principle because of advantages in throughput and measurement quality. However, in practice existing multiplexing approaches suffer from key limitations. In its simple implementation (TMT-MS2), measurements are distorted by chemical noise leading to poor measurement accuracy. The current state-of-the-art (TMT-MS3) addresses this, but requires specialized quadrupole-iontrap-Orbitrap instrumentation. The complement reporter ion approach (TMTc) produces high accuracy measurements and is compatible with many more instruments, like quadrupole-Orbitraps. However, the required deconvolution of the TMTc cluster leads to poor measurement precision. Here, we introduce TMTc+, which adds the modeling of the MS2-isolation step into the deconvolution algorithm. The resulting measurements are comparable in precision to TMT-MS3/MS2. The improved duty cycle, and lower filtering requirements make TMTc+ more sensitive than TMT-MS3 and comparable with TMT-MS2. At the same time, unlike TMT-MS2, TMTc+ is exquisitely able to distinguish signal from chemical noise even outperforming TMT-MS3. Lastly, we compare TMTc+ to quantitative label-free proteomics of total HeLa lysate and find that TMTc+ quantifies 7.8k versus 3.9k proteins in a 5-plex sample. At the same time the median coefficient of variation improves from 13% to 4%. Furthermore, TMTc+ advances quantitative proteomics by enabling accurate, sensitive, and precise multiplexed experiments on more commonly used instruments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Liquid argon TPC signal formation, signal processing and reconstruction techniques

This document describes a reconstruction chain that was developed for the ArgoNeuT and MicroBooNE experiments at Fermilab. These experiments study accelerator neutrino interactions that occur in a Liquid Argon Time Projection Chamber. Reconstructing the properties of particles produced in these interactions benefits from the knowledge of the micro-physics processes that affect the creation and transport of ionization electrons to the readout system. A wire signal deconvolution technique was developed to convert wire signals to a standard form for hit reconstruction, to remove artifacts in the electronics chain and to remove coherent noise. A unique clustering algorithm reconstructs line-like trajectories and vertices in two dimensions which are then matched to create of 3D objects. In conclusion, these techniques and algorithms are available to all experiments that use the LArSoft suite of software.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optical homodyne tomography with polynomial series expansion

We present and demonstrate a method for optical homodyne tomography based on the inverse Radon transform. Different from the usual filtered back-projection algorithm, this method uses an appropriate polynomial series to expand the Wigner function and the marginal distribution, and discretize Fourier space. We show that this technique solves most technical difficulties encountered with kernel deconvolution-based methods and reconstructs overall better and smoother Wigner functions. We also give estimators of the reconstruction errors for both methods and show improvement in noise handling properties and resilience to statistical errors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

WE-AB-207A-07: A Planning CT-Guided Scatter Artifact Correction Method for CBCT Images

Purpose: Cone beam computed tomography (CBCT) imaging is on increasing demand for high-performance image-guided radiotherapy such as online tumor delineation and dose calculation. However, the current CBCT imaging has severe scatter artifacts and its current clinical application is therefore limited to patient setup based mainly on the bony structures. This study’s purpose is to develop a CBCT artifact correction method. Methods: The proposed scatter correction method utilizes the planning CT to improve CBCT image quality. First, an image registration is used to match the planning CT with the CBCT to reduce the geometry difference between the two images. Then, the planning CT-based prior information is entered into the Bayesian deconvolution framework to iteratively perform a scatter artifact correction for the CBCT mages. This technique was evaluated using Catphan phantoms with multiple inserts. Contrast-to-noise ratios (CNR) and signal-to-noise ratios (SNR), and the image spatial nonuniformity (ISN) in selected volume of interests (VOIs) were calculated to assess the proposed correction method. Results: Post scatter correction, the CNR increased by a factor of 1.96, 3.22, 3.20, 3.46, 3.44, 1.97 and 1.65, and the SNR increased by a factor 1.05, 2.09, 1.71, 3.95, 2.52, 1.54 and 1.84 for the Air, PMP, LDPE, Polystryrene, Acrylic, Delrin and Teflon inserts, respectively. The ISN decreased from 21.1% to 4.7% in the corrected images. All values of CNR, SNR and ISN in the corrected CBCT image were much closer to those in the planning CT images. The results demonstrated that the proposed method reduces the relevant artifacts and recovers CT numbers. Conclusion: We have developed a novel CBCT artifact correction method based on CT image, and demonstrated that the proposed CT-guided correction method could significantly reduce scatter artifacts and improve the image quality. This method has great potential to correct CBCT images allowing its use in adaptive radiotherapy.

60 APPLIED LIFE SCIENCES↗

Electrospray Ionization with High-Resolution Mass Spectrometry as a Tool for Lignomics: Lignin Mass Spectrum Deconvolution

The capability to characterize lignin, lignocellulose, and their degradation products is essential for the development of new renewable feedstocks. Electrospray ionization high-resolution time-of-flight mass spectrometry (ESI-HR TOF-MS) method was developed expanding the lignomics toolkit while targeting the simultaneous detection of low and high molecular weight (MW) lignin species. The effect of a broad range of electrolytes and various ionization conditions on ion formation and ionization effectiveness was studied using a suite of mono-, di-, and triarene lignin model compounds as well as kraft alkali lignin. Contrary to the previous studies, the positive ionization mode was found to be more effective for methoxy-substituted arenes and polyphenols, i.e., species of a broadly varied MW structurally similar to the native lignin. For the first time, we report an effective formation of multiply charged species of lignin with the subsequent mass spectrum deconvolution in the presence of 100 mmol L{sup −1} formic acid in the positive ESI mode. The developed method enabled the detection of lignin species with an MW between 150 and 9000 Da or higher, depending on the mass analyzer. The obtained M{sub n} and M{sub w} values of 1500 and 2500 Da, respectively, were in good agreement with those determined by gel permeation chromatography. Furthermore, the deconvoluted ESI mass spectrum was similar to that obtained with matrix-assisted laser desorption/ionization (MALDI)-HR TOF-MS, yet featuring a higher signal-to-noise ratio. The formation of multiply charged species was confirmed with ion mobility ESI-HR Q-TOF-MS. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First results from the Goddard High-Resolution Spectrograph - A demonstration of spectral resolution and experiments with deconvolution

High-quality spectra of the sharp-lined star Chi Lupi were obtained with the Goddard High Resolution Spectrograph (GHRS). Spectra for the various resolving powers achievable with the echelle and G160M gratings are displayed. The effect of spherical aberration upon the spectral resolution is found to be negligible when using the small science aperture. The resolution of the large science aperture spectra is degraded by less than a factor of two. Efforts with spectral deconvolution using several techniques show that it is possible to regain much of the spectral resolution lost in the large science aperture if high signal-to-noise spectra are obtained.

Wahlgren, Glenn M.↗

Acoustic Characterization of the NASA Langley 14- by 22-Foot Subsonic Tunnel using a Phased Array

A characterization test was conducted in the NASA Langley Research Center 14- by 22-Foot Subsonic Tunnel to assess recent acoustic modifications in the facility. Test section reflectivity, background noise and shear layer effects were evaluated by taking measurements of known noise sources. Both conventional speakers and a high-pressure air source were employed as noise generation mechanisms. These were mounted to a pole or fairing at a consistent location in the test section. The source waveforms were used to represent the expected frequency content of scaled Urban Air Mobility vehicles. Acoustic measurements were taken using two unique microphone arrays placed outside the core flow, one of which was a 54-element streamwise-traversing phased array. The other was an 11-element linear tower array. The applicability of phased array acoustic beamforming techniques to mitigate shear layer effects and reject background noise is presented. Additionally, beamforming results are compared to results from single-microphone processing techniques. Flow speeds investigated ranged from Mach 0.00 (static) to Mach 0.12. The tunnel has been partially acoustically treated but still exhibits flow noise, reducing the signal-to-noise ratio of the source under investigation. Conventional beamforming was able to capture high frequency content passing through the shear layer better than single microphone measurements. CLEAN deconvolution improves source mapping at low frequencies.

phased array↗

Iterative deconvolution of x ray and optical SNR images

Blind Iterative Deconvolution (BID) is a technique which was originally developed to correct the degrading effects of atmospheric turbulence on astronomical images from single short exposure, high signal-to-noise-ratio frames. At the Center for Astro physics, we have implemented a version of BID following the general approach of Ayers and Dainty (1988), but extending the technique to use Wiener filtering, and developed it for application to high energy images from Einstein and ROSAT. In the optical, the point spread function (PSF) that degrades the images is due to a combination of telescope and atmospheric aberrations. At high energies, the degrading function is the instrument response function, which is known to be time and energy level unstable. In both cases, the PSF is poorly known, so BID can be used to extract the PSF from the image and then deconvolve the blurred image to produce a sharpened image. Other aspects of this technique are discussed.

Nisenson, Peter↗

Deducing local extremely low frequency field values from large sense coil fluxmeter measurements

Great interest has been increasing in the precise measurements of extremely low frequency ambient magnetic fields which have been recently involved in numerous biological, noise, and compatibility problems. While fluxmeters equipped with sense coils are classified among the most convenient and cheap devices used in measuring such fields, they can never resolve spatially changing field distributions within their sense coil dimensions. This paper presents an approach, based on deconvoluting the sense coil response from spatial measurements, which can be used to infer local field distributions within the fluxmeter sense coil dimensions. Theoretical details as well as sample measurements and simulation results are given in the paper.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SPARSE FARADAY ROTATION MEASURE SYNTHESIS

Faraday rotation measure synthesis is a method for analyzing multichannel polarized radio emissions, and it has emerged as an important tool in the study of Galactic and extragalactic magnetic fields. The method requires the recovery of the Faraday dispersion function from measurements restricted to limited wavelength ranges, which is an ill-conditioned deconvolution problem. Here, we discuss a recovery method that assumes a sparse approximation of the Faraday dispersion function in an overcomplete dictionary of functions. We discuss the general case when both thin and thick components are included in the model, and we present the implementation of a greedy deconvolution algorithm. We illustrate the method with several numerical simulations that emphasize the effect of the covered range and sampling resolution in the Faraday depth space, and the effect of noise on the observed data.

79 ASTRONOMY AND ASTROPHYSICS↗

A 189 MHz, 2400 deg{sup 2} POLARIZATION SURVEY WITH THE MURCHISON WIDEFIELD ARRAY 32-ELEMENT PROTOTYPE

We present a Stokes I, Q and U survey at 189 MHz with the Murchison Widefield Array 32 element prototype covering 2400 deg{sup 2}. The survey has a 15.6 arcmin angular resolution and achieves a noise level of 15 mJy beam{sup -1}. We demonstrate a novel interferometric data analysis that involves calibration of drift scan data, integration through the co-addition of warped snapshot images, and deconvolution of the point-spread function through forward modeling. We present a point source catalog down to a flux limit of 4 Jy. We detect polarization from only one of the sources, PMN J0351-2744, at a level of 1.8% {+-} 0.4%, whereas the remaining sources have a polarization fraction below 2%. Compared to a reported average value of 7% at 1.4 GHz, the polarization fraction of compact sources significantly decreases at low frequencies. We find a wealth of diffuse polarized emission across a large area of the survey with a maximum peak of {approx}13 K, primarily with positive rotation measure values smaller than +10 rad m{sup -2}. The small values observed indicate that the emission is likely to have a local origin (closer than a few hundred parsecs). There is a large sky area at {alpha} {>=} 2{sup h}30{sup m} where the diffuse polarized emission rms is fainter than 1 K. Within this area of low Galactic polarization we characterize the foreground properties in a cold sky patch at ({alpha}, {delta}) = (4{sup h}, -27. Degree-Sign 6) in terms of three-dimensional power spectra.

79 ASTRONOMY AND ASTROPHYSICS↗

Multibaseline gravitational wave radiometry

We present a statistic for the detection of stochastic gravitational wave backgrounds (SGWBs) using radiometry with a network of multiple baselines. We also quantitatively compare the sensitivities of existing baselines and their network to SGWBs. We assess how the measurement accuracy of signal parameters, e.g., the sky position of a localized source, can improve when using a network of baselines, as compared to any of the single participating baselines. The search statistic itself is derived from the likelihood ratio of the cross correlation of the data across all possible baselines in a detector network and is optimal in Gaussian noise. Specifically, it is the likelihood ratio maximized over the strength of the SGWB and is called the maximized-likelihood ratio (MLR). One of the main advantages of using the MLR over past search strategies for inferring the presence or absence of a signal is that the former does not require the deconvolution of the cross correlation statistic. Therefore, it does not suffer from errors inherent to the deconvolution procedure and is especially useful for detecting weak sources. In the limit of a single baseline, it reduces to the detection statistic studied by Ballmer [Classical Quantum Gravity 23, S179 (2006).] and Mitra et al.[Phys. Rev. D 77, 042002 (2008).]. Unlike past studies, here the MLR statistic enables us to compare quantitatively the performances of a variety of baselines searching for a SGWB signal in (simulated) data. Although we use simulated noise and SGWB signals for making these comparisons, our method can be straightforwardly applied on real data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗