Search NASA⌕ Search

SEARCH · Search NASA

Results for “Non-Destructive Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Correlating energy density induced residual stress, porosity, and mechanical property variations in directed energy deposition using neutron diffraction and imaging techniques

In a directed energy deposition (DED) process, the energy density deposited into the materials drives the structure and properties. The energy density is influenced by several printing parameters, such as laser power, hatch spacing, scanning speed, etc. In this study, 316L stainless steels samples were fabricated with varying hatch spacing aiming to induce variations in sample microstructure and properties. A combination of techniques including engineering neutron diffraction, neutron computed tomography, and tensile testing, were employed to correlate the structure and macroscopic properties. Porosity was predominantly observed at the bottom of the deposited materials and was effectively reduced by decreased hatch spacing. Correlatively, compressive residual stress was observed at the bottom of the specimens, while internal stress is largely determined by the hatch spacing. The residual stress in general decreases as the hatch spacing decreases. The maximum ultimate tensile strength (UTS) was found to increase from 517.4 to 528.6 MPa with a strain increased from 0.847 to 0.897 as the hatch spacing decreased from 0.45 to 0.42 mm. However, further increase in energy density by reducing the hatch spacing resulted in a significant decrease in UTS (as low as 452 MPa). This work provides new insights from bulk non-destructive techniques into correlating energy density induced residual stress, porosity, and mechanical property variations in directed energy deposition.

316L stainless steel↗

Neutron Imaging of Al6061 Prepared by Solid-State Friction Stir Additive Manufacturing

Solid-state Friction Stir Additive Manufacturing has recently gained attention as a result of its capacity to fabricate large-scale parts while preserving the mechanical properties of the feedstock material. However, the correlation between the quality of layer-by-layer bonding of the deposited metal and processing parameters has remained unknown. Neutron imaging techniques, with 90% total transmission per cm, are employed for Al6061 parts fabricated by MELD ® Technology as a non-destructive evaluation approach for the first time to investigate the layer-by-layer structure of a stadium-shaped ingot in different sections. The post-processed results show the fabricated parts with an optimized set of processing parameters are void-free. However, the hydrocarbon-based feedstock lubricant segregates between the layers, which consequently may lead to non-uniform weaker mechanical properties along the build direction and stimulate crack initiation during mechanical loading. The tensile test results show 14% lower strain-to-failure values in alleged contaminated areas in transmission imaging results. Additionally, layer bonding is significantly impacted by hot-on-hot and hot-on-cold layer deposition schemes, especially for larger layer thicknesses.

36 MATERIALS SCIENCE↗

Mitigation for Removal of Building 01-103 in the Area 1 Subdock, Nevada National Security Site, Nye County, Nevada

Building 01-103, the Drill Bit Repair Building was originally recorded as SHPO Resource No. B18848 in 2020 during an architectural survey of the Area 1 Subdock (Collins et al. 2022). It was recommended individually eligible for listing in the NRHP under Criteria A and C and contributing to the significance of the Area 1 Subdock Historic District. The SHPO concurred with these determinations in a letter dated April 29, 2022 (Reed 2022). The Drill Bit Repair Building retains all seven aspects of integrity. The location, materials, workmanship, feeling, and association have not changed since its original construction. The design was modified slightly in 1996 with the addition of a removable and non-destructive chain-link fence. Nearby buildings 01-101 and 01-102 were removed (Collins and Menocal 2020) but the other buildings and storage yards remain. Therefore, the integrity of setting has been changed, but not to the degree that the building no longer conveys its significance (see Figures 4 and 5 for comparison). Building 01-103 was constructed in 1985 to coincide with the relocation of the Area 3 Subdock to Area 1. The design for the new Subdock provided a centralized cluster of buildings surrounded by two large storage yards. The buildings included administrative and engineering office space, warehouses, a radiograph building, and Building 01-103 as the drill bit maintenance and repair building, among others. The Drill Bit Repair Building was critical to the success of underground nuclear testing and is eligible under Criterion A for its contribution to broad patterns of history by maintaining specially designed equipment for underground nuclear testing at the NNSS. It is also eligible under Criterion C as it is the only recorded example of a facility built specifically for the maintenance of big-hole drill bits on the NNSS. As it retains both significance and integrity, it remains individually eligible under Criteria A and C. In addition to its individual significance, the Drill Bit Repair Building also contributes to the significance of the Area 1 Subdock Historic District as a representative of a big-hole drilling support facility necessary for underground nuclear testing. The building and the equipment therein were designed specifically for testing at the NNSS, where much of the early technology and methods for big-hole drilling were developed. Its removal will result in not only the demolition of a contributing element but also a change in the physical features of the district’s setting that contribute to its historic significance. The change in setting will diminish the district’s integrity. However, the district still contains numerous examples of other buildings constructed for the purpose of supporting big-hole drilling and remains eligible under Criteria A and C.

54 ENVIRONMENTAL SCIENCES↗

Nondestructive Evaluation (NDE) of Cable Anomalies using Frequency Domain Reflectometry (FDR) and Spread Spectrum Time Domain Reflectometry (SSTDR)

This report presents a comparative assessment of the performance of frequency domain reflectometry (FDR) and spread spectrum time domain reflectometry (SSTDR) in detecting a wide range of electrical cable anomalies. All tests and results reported herein were performed at the PNNL Accelerated and Real-Time Environmental Nodal Assessment (ARENA) cable and motor test bed. The primary objective of this work was to evaluate the effectiveness of SSTDR, a fledgling cable monitoring technique that shows promise for application in online monitoring of energized cable systems, against FDR, an offline technique widely employed in the nuclear power plant (NPP) industry. FDR tests are becoming more widely used in nuclear power plant cable aging management and test programs – particularly for low voltage cables. FDR capabilities for these kinds of tests have been reported by PNNL and others. The FDR test is performed on de-energized cables by connecting the FDR instrument to two of the cable conductors, or one conductor and the shield. A broad band low voltage (< 5 V) chirp is introduced in the cable, and any reflected response is captured in the frequency domain. The captured reflection is then processed by performing an inverse Fourier transform to a time domain response which can then be converted to a distance response based on the cable velocity of propagation (VoP). SSTDR measurements are functionally similar to FDR measurements in that a broad-band voltage signal composed of a square or sine wave modulated pseudo-random sequence of chips (< 5 volts), is injected onto one of the cable conductors. The injected signal will experience partial energy reflection and transmission at each impedance discontinuity along the transmission line. Any reflected response is detected by computing a cross-correlation between the reflected signals and a delayed copy of the incident SSTDR signal. the time delay for the reflected signal to experience the best matched correlation with the incident signal, indicates the travel time for the signal to reach a change in impedance. By knowing this time delay and velocity of propagation (VoP) of the signal, one can compute the physical distance. A big advantage that SSTDR measurements have over other methods is the ability to be connected to energized or live wires (currently up to 1kV) thereby enabling online monitoring of cables. SSTDR has been used successfully in several applications, e.g., aircraft, rail, and photovoltaic systems. In this work FDR and SSTDR cable assessment techniques were used to characterize a variety of cable anomalies and faults including: (1) Presence or absence of a motor; (2) Ground faults and short circuit faults; (3) Moist environments and water ingress faults; (4) Accelerated thermal aging. Both shielded and non-shielded cables were evaluated in this report. Offline measurements were made using FDR and online measurements were made by SSTDR for a range of test scenarios. Based on the results across all cable anomalies evaluated in this study, FDR displayed high sensitivity towards cable condition assessment, while SSTDR showed promise for future application in monitoring NPP cable systems. However, further developments are suggested to improve the resolution and sensitivity of SSTDR towards faults and anomalies in low voltage cables.rt presents a comparative

42 ENGINEERING↗

Self-supervised and multi-fidelity learning for extended predictive soil spectroscopy

Infrared spectroscopy is a cost-effective, non-destructive, and environmentally benign technology that is increasingly recognized as an important solution for meeting the global demand for soil data. While both near-infrared (NIR) and mid-infrared (MIR) diffuse reflectance spectroscopy enable rapid estimation of soil properties, they present a significant trade-off: NIR offers superior scalability and lower operational costs, whereas MIR provides higher analytical fidelity by capturing fundamental molecular vibrations. In this study, we propose a self-supervised, multi-fidelity learning framework designed to bridge this gap. Our approach leverages large-scale MIR spectral libraries to learn a compact, transferable latent representation, into which NIR spectra are subsequently aligned for downstream prediction. The workflow consists of pretraining a latent model on a large MIR library, adapting the representation using a smaller paired NIR–MIR dataset, and evaluating generalization on an independent external test set. Across a range of chemical and physical soil properties, we found that MIR-derived embeddings improved prediction accuracy relative to baseline models that used raw MIR inputs. Predictions derived from the spectrum conversion (NIR to MIR) task did not match the performance of the original MIR spectra but were similar or superior to predictive performance of NIR-only models, suggesting the unified spectral latent space can effectively leverage the larger and more diverse MIR dataset for prediction of soil properties not well represented in current NIR libraries.

54 ENVIRONMENTAL SCIENCES↗

Direct observation of C 3 S particle dissolution using fast nano X-ray computed tomography

Tricalcium silicate (C 3 S) occupies 50 % to 70 % of ordinary portland cement (OPC) by mass and it is an important component affecting the hydration of OPC [1], [2], [3], [4], [5], [6], [7]. Generally, the hydration of C 3 S is described by two processes: the dissolution of C 3 S particles and the precipitation of hydration products. While it is understood that the dissolution rates of C 3 S vary with time, more precise measurements are needed to understand this process. Many mechanisms have been proposed to explain the time-evolving dissolution rates of C 3 S [2]. The metastable barrier hypothesis suggests that a thin metastable layer of hydrates forms around the C 3 S particle surface and prohibits the access of grains to the aqueous solution [8], [9], [10], [11], [12]. The slow dissolution step hypothesis suggests that the increased ion concentration from the initial reaction delays the C 3 S dissolution [2], [13], [14], [15], [16], [17]. More recent publications suggest that C 3 S may react differently depending on the existence of crystallographic defects [18], [19], [20]. Etch pits are thought to open on the particle surface during the initial reaction and this contributes to the C 3 S dissolution [21], [22]. As hydrates precipitate and cover these highly reactive surfaces, hydration slows down and the induction period starts [18], [23], [24], [25], [26]. Many experiments have been conducted to test the aforementioned mechanisms. Some hydration studies utilize bulk measurements, such as isothermal calorimetry [27], [28], [29], pore solution analysis [30], quasi-elastic neutron scattering [31], and nuclear magnetic resonance spectroscopy [32], [33]. One limitation of these measurements is that they do not provide direct and detailed information on the individual C 3 S particles. Some other studies utilize imaging techniques, such as scanning electron microscopy (SEM) [34], [35], [36] and transmission electron microscopy (TEM) [37]. However, SEM/TEM cannot track the evolution of individual particles throughout hydration [34], [35], [38], [39], [40] and they do not give insights into the microstructure of materials before hydration [34], [35], [39]. This makes it challenging to draw strong conclusions from only SEM or TEM observations. Synchrotron X-ray tomography techniques have been used more broadly in recent years to study cement hydration. They are not only non-destructive but also able to image a sample in full 3D with resolutions that can reach from micron to nanoscale. Nano computed tomography (nCT) is one technique that has been applied to study cement hydration at the nanoscale [26], [41]. A typical nCT can reach a pixel size from 15 to 65 nm, providing enough detail for observing features <1 μm. However, nCT often takes >0.5 h to finish one scan. This makes the application of this technique on continuous scans for in-situ observations challenging. Fast X-ray computerized tomography (fCT) is another technique that has shown success in studying the time-evolving cement microstructures [20], [42], [43], [44], [45], [46], [47], [48], [49]. Due to the high flux of the X-ray beam from the synchrotron ring, fCT allows a scan to be captured within 1 min at a pixel size of 1 μm. This allows a paste sample to be continuously scanned during the hydration process. However, the micron-sized resolutions limit does not provide detailed insights for particles <5 μm [20], [49]. Fortunately, the combination of nCT and fCT has allowed the development of fast nano X-ray computed tomography (fnCT). fnCT can capture a 3D data set in <2 min at a pixel size of 50 nm. This makes this procedure an exciting method to evaluate hydrating pastes. fnCT collects multiple X-ray radiographs at various rotation angles and generates a 3D model of the scanned sample, which is also referred to as a 3D tomography [50], [51]. In one tomography, the X-ray absorptions of different components (e.g., C 3 S and hydrates) differ as functions of density and chemistry [52], [53]. These X-ray absorption contrasts can be used to extract detailed information about the 3D microstructure [26], [54], [55]. In this paper, fnCT is used to collect time-lapse tomographs of hydrating C 3 S paste from 18 min after mixing to 7 h of hydration. The bulk measurements of anhydrous C 3 S, as well as the microstructural changes of individual C 3 S particles, are directly observed, quantified, and discussed. The dissolution behavior of C 3 S particles at various size scales is systematically analyzed and compared. This work aims to find the relationship between the size of C 3 S particle sizes and their dissolution rates. This provides significant insights into the early-age hydration of C 3 S on length and time scales not previously possible. Because of the magnitude of the data and the substantial amount of observations, this work will solely focus on the change in the anhydrous particles. Changes in the hydration products will be reported in future work.

42 ENGINEERING↗

Ringing Artifact Reduction Method for Ultrasound Reconstruction Using Multi-Agent Consensus Equilibrium

Non-destructive characterization of multi-layered structures that can be accessed from only a single side is important for applications such as well-bore integrity inspection. Existing methods related to Synthetic Aperture Focusing Technique (SAFT) rapidly produce acceptable results but with significant artifacts. Recently, ultrasound model-based iterative reconstruction (UMBIR) approaches have shown significant improvements over SAFT. However, even these methods produce ringing artifacts due to the high fractional-bandwidth of the excitation signal.In this paper, we propose a ringing artifact reduction method for ultrasound image reconstruction that uses a multi-agent consensus equilibrium (RARE-MACE) framework. Our approach integrates a physics-based forward model that accounts for the propagation of a collimated ultrasonic beam in multi-layered media, a spatially varying image prior, and a denoiser designed to suppress the ringing artifacts that are characteristic of reconstructions from high-fractional bandwidth ultrasound sensor data. We test our method on simulated and experimental measurements and show substantial improvements in image quality compared to SAFT and UMBIR.

Alanazi, Abdulrahman M↗

Versatile recognition of graphene layers from optical images under controlled illumination through green channel correlation method

In this study, a simple yet versatile method is proposed for identifying the number of exfoliated graphene layers transferred on an oxide substrate from optical images, utilizing a limited number of input images for training, paired with a more traditional number of a few thousand well-published Github images for testing and predicting. Two thresholding approaches, namely the standard deviation-based approach and the linear regression-based approach, were employed in this study. The method specifically leverages the red, green, and blue color channels of image pixels and creates a correlation between the green channel of the background and the green channel of the various layers of graphene. This method proves to be a feasible alternative to deep learning-based graphene recognition and traditional microscopic analysis. The proposed methodology performs well under conditions where the effect of surrounding light on the graphene-on-oxide sample is minimum and allows rapid identification of the various graphene layers. Here, the study additionally addresses the functionality of the proposed methodology with nonhomogeneous lighting conditions, showcasing successful prediction of graphene layers from images that are lower in quality compared to typically published in literature. In all, the proposed methodology opens up the possibility for the non-destructive identification of graphene layers from optical images by utilizing a new and versatile method that is quick, inexpensive, and works well with fewer images that are not necessarily of high quality.

36 MATERIALS SCIENCE↗

Ultrasonic Characterization of Lithium Ion Thermal Runaway Conditions for Real-time Ultrasonic Enabled BMS Integration

The demand for energy storage is growing, and lithium-ion batteries are a promising technology to meet this need due to their high power/energy density, high round-trip efficiency, rapid response time, and portability. However, recent catastrophic events caused by thermal runaway have slowed their adoption, highlighting the need for an early warning system for battery failure. In this work, ultrasound is used to detect physical changes in 950 mAh batteries by identifying material property changes independent of voltage and current. [Ultrasound signal features (e.g., time of flight, maximum frequency component) were extracted as the batteries were cycled and subjected to both constant current and constant voltage overcharge and were used to develop two metrics identifying failure: a warning to detect the start of overcharge and an emergency stop (E-stop) to immediately take the battery out of service. The identification method involved locating magnitude differences of several ultrasound features compared to baseline operation considering different currents and temperatures, and the warning/stopping metrics were consistent across all experiments. For an average overcharge time of 140 minutes, the average warning was issued 124 minutes before the failure and the average E-stop was triggered 94 minutes before failure. As a test of using ultrasound for early warning detection, a battery was forced into overcharge and returned to normal cycling conditions based on the previously determined warning metric. Both the voltage profile and the ultrasound measurements returned to their baseline behavior, indicating that ultrasonic detection can not only identify battery failure before a catastrophic event, but can also provide early enough warnings such that overcharges can be detected and corrected quickly enough so the battery does not need to be decommissioned.]

25 ENERGY STORAGE↗

Demonstrating resonant ultrasound spectroscopy as a viable technique to characterize thermally conditioned high explosive materials

We present results of resonant ultrasound spectroscopy (RUS) measurements applied to granular high explosive materials at different bulk pressing densities and degree of thermal conditioning. The material chosen in this study is a ubiquitously used explosive material known as pentaerythritol tetranitrate (PETN), which is used commercially in civil and defense applications both as a binderized plastic bonded explosive material and an unbinderized neat material. However, changes in granular PETN bulk elastic properties due to thermal conditioning, which could have implications for better understanding environmental aging-related effects, have not been well studied even though it is believed that elasticity may play an important role in explosive material initiation mechanisms. Furthermore, monitoring elastic property changes in granular explosive pressings has not yet been demonstrated using RUS, which is an appealing non-destructive characterization tool that requires only dry point contact with the explosive material. To this end, we report the first study using RUS to quantify the elastic properties of binderized and neat PETN pressings as well as to quantify changes in elastic properties as a function of both thermal conditioning and bulk pressing density. Elastic stiffness coefficients, sometimes more commonly referred to as elastic constants, calculated from the RUS measurements on the different PETN-based materials show a significant increase for the post-conditioned samples compared to the pre-conditioned samples. This trend of increasing elastic properties with thermal conditioning was consistent for different density pressings, different thermal exposure conditions, and even different neat PETN pressings of differing average crystal sizes and/or specific surface areas.

36 MATERIALS SCIENCE↗

Mounted Accelerometer Frequency Response of Adhesive Products and Aluminum Frame Quick Mounts

An accelerometer mounting technique has large implications on the frequency range and accuracy of the measurement, with stiffness and the mass relative to the monitored structure as the primary concerns. The International Organization for Standardization (ISO) gives an extensive list in 5348:2021, detailing mounting methods, and provides recommendations for testing mounts that are not specifically defined. In the nuclear industry on the laboratory scale, there is a need for vibration measurements for predictive maintenance and process monitoring that are nondestructive and capable of working in high-temperature environments. Commercial adhesive products with easy application and removal were tested as nondestructive methods, while quick mounts to a commonly used aluminum frame were tested as nondestructive and have potential applicability in high-temperature environments. The sinusoidal excitation method was used, measuring frequencies from 50 Hz to 10 kHz in one-third octave band intervals, utilizing three accelerometers and comparing the results to those obtained with the stud-mounting method. Using the lowest ±3 dB threshold across each accelerometer, foam dots and poster strips were not successful, and foam tapes were accurate up to 2000 Hz, hose clamps and zip ties up to 800 Hz, and a custom 3D printed mount up to 1000 Hz. Knowing the limitations of each mounting technique allows for accurate measurements within the appropriate range.

47 - OTHER INSTRUMENTATION↗

Dual X-ray computed tomography-aided classification of melt pool boundaries and flaws in crept additively manufactured parts

In metal additive manufacturing (AM), understanding the process-structure-performance relationships requires a combination of multi-scale characterization techniques that allows for the measurement of the melt pool shape and boundary and classifying various defects and flaws in the AM parts. Such approaches can be destructive, only 2D in nature, or have a small field of view and can be complex to co-register and analyze. Here, in this work, we present a non-destructive 3D inspection technique that employs dual-energy X-ray computed tomography (XCT) along with a model-based iterative reconstruction (MBIR) and a new segmentation algorithm. The proposed approach and algorithm are not only capable of classifying and quantifying flaws such as pores, cracks, and inclusions, but they also allow for the extraction of microstructural features such as melt pool boundaries (MPB) and melt pool regions (MPR), that can help understand process-structure-performance relationships for alloys under study. As an exemplar application, we employed the method for characterization of an additively manufactured aluminum alloy crept under tensile stress at 300 °C for 1064 h. Our results demonstrate high quality segmentation and classification of various flaws and MPB and MPR, for the first time, using 3D X-ray CT inspection. The delineated MPB and MPR in the crept samples reveal the preferential growth paths of cracks that formed during creep deformation. The technique was used for successfully quantifying the characteristics (number of defects, their density, volume fraction, etc.) of the manufacturing-induced pores and creep-induced cracks, which is necessary to better understand the creep failure mechanisms of the material.

36 MATERIALS SCIENCE↗

Beam dynamics corrections in the measurement of the anomalous precession frequency at the Muon $g-2$ experiment at Fermilab

The Muon $g-2$ experiment at Fermilab (E989) aims to measure the anomalous magnetic moment of the muon with an accuracy of 140 ppb (parts per billions). This accuracy, obtained by adding in quadrature a statistical and a systematic contribution of comparable value (100 ppb), will allow to reduce the experimental uncertainty (from the previous E821 experiment at BNL \cite{bnl}) of a factor of 4, and represents one of the most precise tests of the Standard Model (SM) theory of elementary particles. The first result on the Run-1 dataset \cite{prl} was released on April 7, 2021, showing a very good agreement with the previous result from BNL experiment, with a slightly better uncertainty. The corresponding experimental average increases the significance of the discrepancy between the measured and Standard Model prediction of 4.2$\sigma$ \cite{white_paper}.\\ \noindent The measured quantity is the muon magnetic anomaly a$_\mu$=$\frac{g_\mu-2}{2}$ where g$_\mu$ is the gyromagnetic factor of the muon. Dirac's equation predicts g$_\mu$ = 2, while radiative corrections, dominated by the QED contribution due to an exchange of a virtual photon, causes a per-mille correction on this quantity. By including all the SM contributions, a$_\mu$ is known at 370 ppb. The E989 experiment measures $a_\mu$ injecting positive muons with momentum of 3.1 GeV/$c$ polarized longitudinally in bunches (called $fills$) with an average rate of 12 Hz, in a storage ring of 14 meters diameter. Due to the parity violation in the weak muon decay, high energy positrons produced are emitted preferably in the muon's spin direction. By counting the number of positrons with energy greater then 1.7 GeV in function of the time, the frequency precession of the muon spin is measured, that together with the measurement of the magnetic field, allows to extract $a_\mu$. The positrons are detected with 24 electromagnetic calorimeters, that measure the energy and the arrival time of the positrons, each made of 54 crystals of lead fluoride (PbF$_2$) read by silicon photomultipliers (SiPM). Together with calorimeters, two tracking detectors are used to make non-destructive measurements of the muon beam characteristic by reconstructing the muon decay position extrapolating backward the decay positrons. The knowledge of the beam motion inside the ring plays a fundamental role in the analysis of $a_{\mu}$, where the measured anomalous precession frequency $\omega_a$ must be corrected for four main beam dynamics effects. A first correction is associated with the presence of an electric field responsible of the vertical focusing on the storage ring, where vertical direction is orthogonal to the orbit and horizontal direction is along the storage ring radius. Due to the oscillations in the vertical direction, the so called vertical betatron oscillations, a second correction is necessary to account for an average angle associated with the muon motion off the ideal orbit. A third correction is caused by lost muons in the ring which have a different spin phase at the injection respect to the decay ones. Finally, due to the correlation between the vertical and horizontal beam motion of the muons and the acceptance of the calorimeter, a correction (called ``phase-acceptance") arises. In Run1, due to the presence of two damaged resistors in one electrostatic quadrupole, this correction had a prominent role. The replacement of the damaged resistors before Run2 decreased this effect by one order of magnitude, and a further reduction in Run-3 was provided by an improved orbit.\\ \noindent The work of this Thesis focuses on the beam dynamics corrections on $\omega_a$. Due to the prominent role in Run-1 a special attention has been put to the phase-acceptance correction\footnote{The effect of this correction on the E821 BNL measurement of the $g-2$ has been evaluated to be within the quoted systematic error.}. Chapter \ref{ch:anomalous_magnetic_moment} introduces the anomalous magnetic moment of the muon. Chapter \ref{ch:early_experiment} describes the history of the Muon $g-2$ experiments. Chapter \ref{ch:theory} discusses the Standard Model prediction and possible new physics scenario. Chapter \ref{ch:muon_g2_experiment} describes the E989 experiment, whose experimental technique and the apparatus are discussed focusing on the improvements needed to reach the final goal on $a_\mu$ measurement. The original work of the Thesis is discussed in the last 5 chapters. Chapter \ref{ch:experiment_technique} presents the analysis technique to extract $\omega_a$, Chapter \ref{ch:beam_dynamics} describes the beam dynamics in the E989 experiment, Chapter \ref{ch:beam_dynamics_correction} discusses the beam dynamics correction to $\omega_a$, and Chapter \ref{sec:pa_corr} focuses on the phase acceptance correction. Finally Chapter \ref{ch:run23_analysis_improvements} contains the Run-2/3 improvements which are expected to allow for an increased precision ons the beam dynamics co...

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High-Energy X-ray Diffraction Microscopy for Nuclear Forensics FY2022 Project Report

Morphological information on nuclear material has been identified using visible light and scanning electron microscopy. These identify qualitative differences in particle morphology. Three-dimensional imaging of materials through alternating scanning electron microscopy imaging and focused ion beam milling has also been used. Unfortunately, these techniques are time- and labor-intensive, with significant sample preparation required and lengthy analysis times. Further, the resulting 3D images are qualitative, require manual identification, and do not capture statistically-representative populations. High energy X-ray 3D imaging using a direct-beam or diffracted-beam (High-Energy Diffraction Microscopy) have been developed at the Advanced Photon Source and can produce quantitative information on grains (phase, location, etc.) and pores (size distribution, sphericity) in a material. These techniques require only minutes to characterize a sample volume and are non-destructive, thus suitable for a wide range of existing samples and for confirmatory analyses to be carried out using conventional microscopy techniques. In this first year of the project, all uranium oxide samples were synthesized and characterized using conventional analyses by the analytical chemistry laboratory. Conventional analysis methods included powder x-ray diffraction, scanning electron microscopy, impurity analysis via inductively coupled plasma mass spectrometry, and infrared spectroscopy. Impurity analysis shows a drop in boron content from UO 3 to the lowest U 3 O 8 calcination temperature, but otherwise no appreciable difference in any sample. Analysis of diffraction data shows a flip of peaks from UO 3 dominated for the 600 °C calcined sample to U 3 O 8 dominated at 700 °C and 800 °C. Analysis of scanning electron microscopy images shows that with increased calcination temperature the size distribution of particles seems to increase and broaden. Both of these last findings are in line with previously published data, though this work used significantly fewer particles to simply show similar trends instead of getting truly quantitative particle analysis. Infrared analysis similarly shows ingrowth of U 3 O 8 as calcination temperature is increased, along with depression of peaks associated with UO 3 and water. Samples were prepared for analysis at the Advanced Photon Source at beamline 1-ID. It is anticipated that analysis will occur in November of 2022. AI/ML techniques to de-noise data coming out of 1-ID during the analyses was also developed during this time using previously gathered data. Preliminary results using a self-supervision technique called Noise2Selfshow good de-noising of data. Once the uranium oxide samples are analyzed, real data will be used to test the de-noising and other AI/ML techniques that may be developed in the second year of the project.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Ultrasonic Testing of Mechanical Changes in a Water-Filled Pipe with Multi-Mode and Broadband Signals and Two-Level Compensation

Ultrasonic testing (UT) has been widely used for the Nondestructive Evaluation (NDE) of pipes due to its many favorable characteristics. However, one of the main challenges in the general use of UT for real-world pipelines is the sensitivity of this method to environmental and operational condition changes. This paper proposes a new UT method with enhanced compensation for environmental effects and operational condition changes. In particular, the effectiveness of the new method is tested in the presence of temperature variations, and changes in water flow rate inside a stainless-steel pipe. The proposed UT method uses multi-mode and broadband guided ultrasonic waves in the pipe walls, excited and received by single-element ultrasonic sensors that are spatially separated, forming a measurement zone between any pair of such transmit and receive sensors. Amplitude changes, time shifts, and frequency content variations in the ultrasonic signal due to temperature changes and water flow are evaluated and compensated for reliable UT of mechanical changes in the pipe. It is observed that spurious effects of water flow on ultrasonic response, if not properly compensated, can dominate over effects due to actual mechanical changes, but such liquid-boundary effects can be compensated effectively by the proposed time- and frequency-filtering method.

47 OTHER INSTRUMENTATION↗

Post-irradiation examination of AGR-3/4 TRISO fuel compacts using three-dimensional X-ray computed tomography

The AGR-3/4 irradiation tests combined the third and fourth planned irradiation experiments in the US Department of Energy’s Advanced Gas Reactor (AGR) testing campaign of tri-structural isotropic (TRISO) fuel compacts. In this article, we present post-irradiation examination (PIE) using X-ray computed tomography (XCT) of two unirradiated and two irradiated compacts from the AGR-3/4 irradiation tests. The irradiated compacts studied (compact 7–1 and compact 12–4) represent the upper and lower limit of burnup within the AGR-3/4 irradiation experiment. This article presents a detailed quantitative analysis on the post-irradiation structure of TRISO fuel compacts. Various quantitative parameters including shape, size, and packing of kernels, and their spatial distribution, were utilized to gain insights into the structural changes caused by irradiation. The equivalent diameter and sphericity were found to increase and decrease, respectively, in irradiated compact 7–1 due to its higher burnup. Nearest neighbor distance between fuel kernels decreased after irradiation, suggesting irradiation-induced shrinkage of graphitic matrix. Furthermore, each compact in AGR-3/4 irradiation tests contained 20 designed-to-fail (DTF) fuel particles that were meant to act as a source of fission product release to the experiment test train. Furthermore, in the present work, all DTF fuel particles in the four compacts studied were identified, and it was found that they exhibited larger kernel swelling in compact 12–4 and smaller kernel swelling in compact 7–1, compared to the driver particles.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Non-destructive electrochemical diagnosis of failure mechanisms in aqueous zinc batteries

The early detection of secondary reactions that affect the life and performance of zinc manganese oxide batteries requires a shift from conventional time-consuming and often destructive procedures to rapid lifetime-predictive techniques. In this work, an electrochemical approach is employed to elucidate independent signatures for four common types of failure mechanisms in zinc manganese dioxide (Zn||MnO2) batteries—namely, the loss of zinc inventory, the loss of active material at the cathode, electrolyte depletion, and increased cell impedance. Our findings, specific to coin cell configurations, reveal that each induced failure mechanism can be distinctively modeled and identified based on responses from the rest voltage and columbic-efficiency data for prompt detection. For instance, electrolyte depletion response manifests a distinctive abrupt (>80 %) decrease in columbic efficiency (CE) and charge-rest voltage (Vc) while the discharge-rest voltage remained constant at ~1.3 V. Furthermore, electrolyte rejuvenation of the cell increased the CE to >95 % and restored Vc from ~0.3 to >1.7 V. Recovery experiments and reference performance tests demonstrated consistency between electrochemical descriptors and their associated failure mechanisms. Further, the outcomes of this work provide valuable insights and data models for some of the dominant failure mechanisms present in zinc manganese battery chemistries, which are beneficial to accelerated early-lifetime diagnosis and advancement of Zn batteries development.

25 ENERGY STORAGE↗

MIND-MAC: Multi-Level In-memory Quasi Non-Destructive MAC Operation in Compact 2T-nC FeRAM for Efficient DNN Accelerator

We present MIND-MAC, a compact 2T-nC FeRAM architecture that performs multi-level, quasi-non-destructive in-memory multiply–accumulate (MAC) for deep neural networks. By exploiting voltage-controlled partial domain switching in MFM capacitors and read-transistor amplification, the cell stores multi-bit weights and gates bit-serial inputs to produce an accumulated current on shared lines. We combine TCAD-extracted parasitics with experimentally calibrated ferroelectric models in SPICE to validate device-/circuit-level behavior, and validate multi-level sensing and QNRO with measurements on a fabricated 2T-3C test vehicle. An analytical system model maps MIND-MAC to a 6-GB main-memory in-memory compute (IMC) architecture and benchmarks VGG13 inference in 61.08 ms at 964.99 mJ. Results indicate high density, reduced rewrite overhead, and energy efficiency, positioning 2T-nC FeRAM as a promising IMC candidate for next-generation AI hardware.

36 MATERIALS SCIENCE↗