Search NASA⌕ Search

SEARCH · Search NASA

Results for “NonDestructive Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Simulation of crack induced nonlinear elasticity using the combined finite-discrete element method

Numerical simulation of nonlinear elastic wave propagation in solids with cracks is indispensable for decoding the complicated mechanisms associated with the nonlinear ultrasonic techniques in NonDestructive Testing (NDT). Here, we introduce a two-dimensional implementation of the combined finitediscrete element method (FDEM), which merges the finite element method (FEM) and the discrete element method (DEM), to explicitly simulate the crack induced nonlinear elasticity in solids with both horizontal and inclined cracks. In the FDEM model, the solid is discretized into finite elements to capture the wave propagation in the bulk material, and the finite elements along the two sides of the crack also behave as discrete elements to track the normal and tangential interactions between crack surfaces. The simulation results show that for cracked models, nonlinear elasticity is generated only when the excitation amplitude is large enough to trigger the contact between crack surfaces, and the nonlinear behavior is very sensitive to the crack surface contact. The simulations reveal the influence of normal and tangential contact on the nonlinear elasticity generation. Moreover, the results demonstrate the capabilities of FDEM for decoding the causality of nonlinear elasticity in cracked solid and its potential to assist in Non-Destructive Testing (NDT).

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Refraction-enhanced x-ray radiography for inertial confinement fusion and laser-produced plasma applications

We explore various laser-produced plasma and inertial confinement fusion applications of phase-contrast x-ray radiography, and we show how the main features of these enhancements can be considered from a geometrical optics perspective as refraction enhancements. This perspective simplifies the analysis and often permits simple analytical formulas to be derived that predict the enhancements. We explore a raytrace approach to various material interface applications, and we explore a more general example of refractive bending of x rays by an implosion plasma. We find that refraction-enhanced x-ray radiography of implosions may provide a means to quantify density differences across shock fronts as well as density variations caused by local heating due to high-Z dopants. We also point out that refractive bending by implosions plasmas can blur fine radiograph features and can also provide misleading contrast information on area-backlit pinhole imaging experiments unless its effects are taken into consideration.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

X-Pinch And Its Applications In X-ray Radiograph

An X-pinch device and the related diagnostics of x-ray emission from X-pinch were briefly described. The time-resolved x-ray measurements with photoconducting diodes show that the x-ray pulse usually consists of two subnanosecond peaks with a time interval of about 0.5 ns. Being consistent with these two peaks of the x-ray pulse, two point x-ray sources of size ranging from 100 mum to 5 mum and depending on cut-off x-ray photon energy were usually observed on the pinhole pictures. The x-pinch was used as x-ray source for backlighting of the electrical explosion of single wire and the evolution of X-pinch, and for phase-contrast imaging of soft biological objects such as a small shrimp and a mosquito.

07 ISOTOPE AND RADIATION SOURCES↗

Measurements of Self-Generated Magnetic Fields Influence on Electron Heat Conduction in Dense Plasmas

Proton radiography measurements of self generated magnetic fields developing in long pulse (ns), high-power laser plasma interactions were employed to investigate the influence of these fields on the propagation of heat flow in dense plasmas. During the experiments, the heat wave propagation speed was measured simultaneously with the fields. These two coupled measurements could give an insight on the limitations of current numerical models of heat transport. They suggest that non locality of heat transport and diffusion of magnetic fields are important to model correctly the interaction.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

LINEAR SCANNING METHOD BASED ON THE SAFT COARRAY

This work presents a method to obtain B-scan images based on linear array scanning and 2R-SAFT. Using this technique some advantages are obtained: the ultrasonic system is very simple; it avoids the grating lobes formation, characteristic in conventional SAFT; and subaperture size and focussing lens (to compensate emission-reception) can be adapted dynamically to every image point. The proposed method has been experimentally tested in the inspection of CFRP samples.

36 MATERIALS SCIENCE↗

NEW DEVELOPMENTS IN DIGITAL X-RAY TECHNIQUES: A SIMULATION TOOL FOR SCATTERING IMAGING

This paper focus mainly on a simulation tool used to compute X-ray imaging technique and the last developments with the calculation of the scattering. It allows evaluating the scattered contribution on a transmission detector but also simulating scattering technique as Compton or Rayleigh tomography. A major interest of the Compton scattering technique is that the experimental device is located on one side of the object, and thus, an image can be acquired even if we can not access to the other side of the object.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Visualization of water on through-plane direction of GDL using X-ray radiography

In this investigation, we visualized water distribution and behavior of water on through plane direction of GDL (Gas Diffusion Layer), which is one of components of PEMFC, using X-ray radiography. In order to investigate water distribution and behavior at GDL of PEMFC, the facilities was set up at the 7B2 beam line in Pohang Accelerator Laboratory. The phenomena of cathode side GDL is more important because the cathode side GDL has more water than the anode side. For this reason, the cathode side GDL was targeted and test section (Figure 1) was made to make similar boundary condition with a cathode side GDL of operating PEMFC. GDL faced two single channels. One is air channel as cathode gas channel of PEMFC and the other is liquid channel as cathode catalyst layer. Water is produced in cathode catalyst layer and almost of this water transport through cathode GDL. Because of this, liquid channel was adopted as catalyst layer. Images of water distribution were recorded per 4 second under various liquid pressure conditions. Water content was calculated from these images using mathematic process.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Dimensional Control of Micro Components with Synchrotron Computed Tomography

An advantage of Computed Tomography (CT) is the coordinate measurement capability of small inner structures, which are not accessible with classical measurement techniques. Using the advantages of synchrotron radiation CT measurements of parts with sizes of a few millimeters are performed at BAMline of BESSY II and are expected to be used as references for further dimensional measurements with micro CT. Previous investigations were focused on external gears, which are accessible with standard Coordinate Measurement Machines (CMMs). To obtain information about the accuracy of dimensional measurements of internal gears with CT, reference data have been measured by a tactile-optical CMM. This information is used to evaluate the performance of the CT. In addition to the first results for the evaluation of internal gear flanks, new measurements of different gear materials (steel and zirconium dioxide) will be presented. For functional evaluation, gear flanks are a matter of particular interest. Form deviations are analyzed with respect to the different gear materials to establish CT measurements as technology in the field of quality assurance and to compare the different manufacturing processes.

07 ISOTOPE AND RADIATION SOURCES↗

High-resolution multi-MeV x-ray radiography using relativistic laser-solid interaction

When high intensity ({>=}10{sup 19} W cm{sup -2}) laser light interacts with matter, multi-MeV electrons are produced. These electrons can be utilized to generate a MeV bremsstrahlung x-ray emission spectrum as they propagate into a high-Z solid target positioned behind the interaction area. The short duration (<10 ps) and the small diameter (<500 {mu}m) of the x-ray pulse combined with the MeV x-ray spectrum offers an interesting alternative to conventional bremsstrahlung x-ray sources based on an electron accelerator used to radiograph dense, rapidly moving objects. In experiments at the Omega EP laser, a multi-MeV x-ray source is characterized consistently with number of independent diagnostics. An unfiltered x-ray dose of approximately 2 rad in air at 1 m and a source diameter of less than 350 {mu}m are inferred. Radiography of a complex and high area density (up to 61 g/cm{sup 2}) object is then performed with few hundred microns spatial resolution.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Anomalous self-generated electrostatic fields in nanosecond laser-plasma interaction

Electrostatic (E) fields associated with the interaction of a well-controlled, high-power, nanosecond laser pulse with an underdense plasma are diagnosed by proton radiography. Using a current three-dimensional wave propagation code equipped with nonlinear and nonlocal hydrodynamics, we can model the measured E-fields that are driven by the laser ponderomotive force in the region where the laser undergoes filamentation. However, strong fields of up to 110 MV/m measured in the first millimeter of propagation cannot be reproduced in the simulations. This could point to the presence of unexpected strong thermal electron pressure gradients possibly linked to ion acoustic turbulence, thus emphasizing the need for the development of full kinetic collisional simulations in order to properly model laser-plasma interaction in these strongly nonlinear conditions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Laser-driven cylindrical compression of targets for fast electron transport study in warm and dense plasmas

Fast ignition requires a precise knowledge of fast electron propagation in a dense hydrogen plasma. In this context, a dedicated HiPER (High Power laser Energy Research) experiment was performed on the VULCAN laser facility where the propagation of relativistic electron beams through cylindrically compressed plastic targets was studied. In this paper, we characterize the plasma parameters such as temperature and density during the compression of cylindrical polyimide shells filled with CH foams at three different initial densities. X-ray and proton radiography were used to measure the cylinder radius at different stages of the compression. By comparing both diagnostics results with 2D hydrodynamic simulations, we could infer densities from 2 to 11 g/cm{sup 3} and temperatures from 30 to 120 eV at maximum compression at the center of targets. According to the initial foam density, kinetic, coupled (sometimes degenerated) plasmas were obtained. The temporal and spatial evolution of the resulting areal densities and electrical conductivities allow for testing electron transport in a wide range of configurations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Flash radiography with 24 GeV/c protons

The accuracy of density measurements and position resolution in flash (40 ns) radiography of thick objects with 24 Gev/c protons is investigated. A global model fit to step wedge data is shown to give a good description spanning the periodic table. The parameters obtained from the step wedge data are used to predict transmission through the French Test Object (FTO), a test object of nested spheres, to a precision better than 1%. Multiple trials have been used to show that the systematic errors are less than 2%. Absolute agreement between the average radiographic measurements of the density and the known density is 1%. Spatial resolution has been measured to be 200 {mu}m at the center of the FTO. These data verify expectations of the benefits provided by high energy hadron radiography for thick objects.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Backscatter x-ray development for space vehicle thermal protection systems

The Backscatter X-Ray (BSX) imaging technique is used for various single sided inspection purposes. Previously developed BSX techniques for spray-on-foam insulation (SOFI) have been used for detecting defects in Space Shuttle External Tank foam insulation. The developed BSX hardware and techniques are currently being enhanced to advance Non-Destructive Evaluation (NDE) methods for future space vehicle applications. Various Thermal Protection System (TPS) materials were inspected using the enhanced BSX imaging techniques, investigating the capability of the method to detect voids and other discontinuities at various locations within each material. Calibration standards were developed for the TPS materials in order to characterize and develop enhanced BSX inspection capabilities. The ability of the BSX technique to detect both manufactured and natural defects was also studied and compared to through-transmission x-ray techniques. The energy of the x-ray, source to object distance, angle of x-ray, focal spot size and x-ray detector configurations were parameters playing a significant role in the sensitivity of the BSX technique to image various materials and defects. The image processing of the results also showed significant increase in the sensitivity of the technique. The experimental results showed BSX to be a viable inspection technique for space vehicle TPS systems.

07 ISOTOPE AND RADIATION SOURCES↗

Some notes on the application of discrete wavelet transform in image processing

Mathematical transforms are used in signal processing in order to extract what is known as 'hidden' information. One of these mathematical tools is the Discrete Wavelet Transform (DWT), which has been increasingly employed in non-destructive testing and, more specifically, in image processing. The main concern in the present work is to employ DWT to suppress noise without losing relevant image features. However, some aspects must be taken into consideration when applying DWT in image processing, mainly in the case of weld radiographs, in order to achieve consistent results. Three topics were selected as representative of these difficulties, as follows: 1) How can image matrix be filled to fit the 2{sup n} lines and 2{sup n} rows requirement? 2) How can the most suitable decomposition level of the DWT function and the correct choice of their coefficient suppression be selected? 3) Is there any influence of the scanning direction and the weld radiograph image, e.g., longitudinal or transversal, on the final processing image? It is known that some artifacts may be present in weld radiograph images. Indeed, the weld surface is frequently rough and rippled, what can be seen as gray level variation on the radiograph, being sometimes mistaken as defective areas. Depending on the position of these artifacts, longitudinal or transversal to the weld bead, they may have different influences on the image processing procedure. This influence is clearly seen in the distribution of the DWT Function coefficients. In the present work, examples of two weld radiographs of quite different image quality were given in order to exemplify it.

07 ISOTOPE AND RADIATION SOURCES↗

NDT characterization of boron carbide for ballistic applications

Boron Carbide (B{sub 4}C) is widely used to provide ballistic protection in challenging service environments. This work was carried out to develop non-destructive testing (NDT) for B{sub 4}C characterization. Deliberate flaws were introduced within the B{sub 4}C tiles during manufacturing. An experimental program was undertaken to determine the best method to detect defects in ceramic tiles and material characterization. Ultrasonic characterization of the material was found to be able to detect both density variation and defects within the material.

36 MATERIALS SCIENCE↗

NDE of hybrid armor structures using acoustography

The US Army is investigating the use of composite materials to deliver lightweight and more effective armor protection systems to soldiers and other army assets. However, widespread use of such hybrid armor will require a reliable but fast NDE methodology to ensure integrity of these components during manufacturing and while in service. Traditional ultrasonic inspection of such hybrid armor structures may prove to be very effective, but point-by-point ultrasonic scanning is inherently time-consuming and manufacturing slowdowns could develop in high-volume production of such armor systems. In this paper, we report on the application of acoustography for the NDE of hybrid armor structures. Acoustography differs from conventional ultrasonic testing in that test objects are inspected in full field, analogously to real time x-ray imaging. The approach uses a novel, super high resolution large area acousto-optic (AO) sensor, which allows image formation through simple ultrasound shadow casting, analogous to x-ray image formation. This NDE approach offers significant inspection speed advantage over conventional point-by-point ultrasonic scanning procedures and is well-suited for high volume production. We will report initial results on a number of hybrid armor plate specimens employing composite materials that are being investigated by the US Army. Acoustography NDE results will also be verified using other complimentary NDE methods.

42 ENGINEERING↗

Pulse-echo phased array ultrasonic inspection of pultruded rod stitched efficient unitized structure (PRSEUS)

A PRSEUS test article was subjected to controlled impact on the skin face followed by static and cyclic axial compressions. Phased array ultrasonic inspection was conducted before impact, and after each of the test conditions. A linear phased array probe with a manual X-Y scanner was used for interrogation. Ultrasound showed a delamination between the skin and stringer flange adjacent to the impact. As designed, the stitching in the flange arrested the lateral flaw formation. Subsequent ultrasonic data showed no delamination growth due to continued loading.

42 ENGINEERING↗

Identification Of Natural Dyes On Archaeological Textile Objects Using Laser Induced Fluorescent Technique

This study aims to evaluate the use of Laser Fluorescent as a non-destructive technique for identification of natural dyes on archaeological textile objects. In this study wool textile samples were dyed with 10 natural dyes such as cochineal, cutch, henna, indigo, Lac, madder, safflower, saffron, sumac and turmeric. These dyes common present on archaeological textile objects to be used as standard dyed textile samples. These selected natural dyes will be used as known references that can be used a guide to identify unknown archaeological dyes. The dyed textile samples were investigated with laser radiation in different wavelengths to detect the best wavelengths for identification each dye. This study confirms that Laser Florescent is very useful and a rapid technique can be used as a non-destructive technique for identification of natural dyes on archaeological textile objects. The results obtained with this study can be a guide for all conservators in identification of natural organic dyes on archaeological textile objects.

36 MATERIALS SCIENCE↗