Search NASA⌕ Search

SEARCH · Search NASA

Results for “OPTICAL BEAM SCANNING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Analysis of synthetic electron cyclotron emission from the high field side of HL-2M tokamak plasmas

A synthetic electron cyclotron emission (ECE) diagnostic is used to interpret ECE signals from preset plasma equilibrium profiles, including magnetic field, electron density, and electron temperature. According to the simulation results, the electron temperature (T e ) profile covering the harmonic overlap region can be obtained by receiving ECE signals at the high field side (HFS) of the HL-2M plasma. The third harmonic ECE at the low field side (LFS) cannot pass through the second harmonic resonance layer at the HFS unless the optical thickness (τ) of the second harmonic becomes gray (τ ≤ 2). In addition, the impact of the relativistic frequency down-shift has been evaluated and corrected. The measurable range of the HFS ECE has been calculated by scanning different parameters (electron density, temperature, and magnetic field). Higher plasma parameters allow a wider radial range of electron temperature measurements. The minimum inner measurable position can reach R = 120 cm (r/a = -0.89) when the product of core temperature (T e0 ) and density (n e0 ) is greater than 35 × 10 19 keV m -3 , which is extended by more than 30 cm inward compared with that of the LFS measurement. The HFS ECE will greatly improve the diagnostic ability of ECE systems on the HL-2M tokamak.

47 OTHER INSTRUMENTATION↗

Cathodoluminescence of Ultrathin Twisted Ge 1–x Sn x S van der Waals Nanoribbon Waveguides

Ultrathin van der Waals semiconductors have shown extraordinary optoelectronic and photonic properties. Propagating photonic modes make layered crystal waveguides attractive for photonic circuitry and for studying hybrid light-matter states. Accessing guided modes by conventional optics is challenging due to limited spatial resolution and poor out-of-plane far field coupling. Scanning near-field optical microscopy (SNOM) can overcome these issues and can characterize waveguide modes down to tens of nm resolution, albeit for planar samples or nanostructures with moderate height variations. Electron microscopy provides atomic-scale localization also for more complex geometries, and recent advances extended the accessible excitations from interband transitions to phonons. In this work, bottom-up synthesized layered semiconductor (Ge 1-x Sn x S) nanoribbons with axial twist and deep sub-wavelength thickness are demonstrated as a platform for realizing waveguide modes, and cathodoluminescence (CL) spectroscopy is introduced as a tool to characterize them. Combined experiments and simulations show the excitation of guided modes by the electron beam and their efficient detection via photons emitted in the ribbon plane, which enables measuring key properties such as the evanescent field into the vacuum cladding with nanometer resolution. The results identify van der Waals waveguides operating in the infrared and highlight an electron microscopy-based approach for probing complex-shaped nanophotonic structures.

36 MATERIALS SCIENCE↗

Defect Complexes in CrSBr Revealed Through Electron Microscopy and Deep Learning

Atomic defects underpin the properties of van der Waals materials, and their understanding is essential for advancing quantum and energy technologies. Scanning transmission electron microscopy is a powerful tool for defect identification in atomically thin materials, and extending it to multilayer and beam-sensitive materials would accelerate their exploration. Here, we establish a comprehensive defect library in a bilayer of the magnetic quasi-1D semiconductor CrSBr by combining atomic-resolution imaging, deep learning, and calculations. We apply a custom-developed machine learning work flow to detect, classify, and average point vacancy defects. This classification enables us to uncover several distinct Cr interstitial defect complexes, combined Cr and Br vacancy defect complexes, and lines of vacancy defects that extend over many unit cells. We show that their occurrence is in agreement with our computed structures and binding energy densities, reflecting the intriguing layer interlocked crystal structure of CrSBr. Our ab initio calculations show that the interstitial defect complexes give rise to highly localized electronic states. These states are of particular interest due to the reduced electronic dimensionality and magnetic properties of CrSBr and are, furthermore, predicted to be optically active. Our results broaden the scope of defect studies in challenging materials and reveal new defect types in bilayer CrSBr that can be extrapolated to the bulk and to over 20 materials belonging to the same FeOCl structural family.

deep learning↗

dlppi2 (b1)

The Doppler lidar (DL) is an active remote-sensing instrument that provides range- and time-resolved measurements of the line-of-sight component of air velocity (i.e., radial velocity) and attenuated aerosol backscatter. The DL operates in the near-infrared and is sensitive to backscatter from atmospheric aerosol, which are assumed to be ideal tracers of atmospheric wind fields. The DL works by transmitting short pulses of infrared laser light into the atmosphere. Atmospheric aerosols scatter a small fraction of that light energy back to the transceiver, where it is collected and recorded as a time-resolved signal. From the delay between the outgoing pulse and the backscattered signal, the instrument infers the distance to the scattering volume. Coherent detection is used to measure the Doppler frequency shift of the backscatter signal. This is accomplished by mixing the backscatter signal with a reference laser beam (i.e., local oscillator) of known frequency. The onboard signal processor then determines the Doppler frequency shift from the spectrum of the mixed signal. The Doppler frequency shift and thus the radial air velocity is determined from the peak of the Doppler spectrum. The attenuated backscatter is determined from the energy content of the Doppler spectra. The DL provides accurate measurements of radial velocity in regions of the atmosphere where aerosol concentrations are high enough to ensure good signal-to-noise ratio. Thus, valid data are usually limited to the atmospheric boundary layer where aerosol is ubiquitous. Valid measurements can also be obtained in elevated aerosol layers or in optically thin clouds above the boundary layer. Most of the ARM DLs have full upper-hemispheric scanning capability, enabling 3D mapping of turbulent flows in the atmospheric boundary layer. With the scanner pointed vertically, the DL provides height- and time-resolved measurements of vertical velocity.

54 ENVIRONMENTAL SCIENCES↗

Plug-and-play polymer microfluidic chips for hydrated, room temperature, fixed-target serial crystallography

The practice of serial X-ray crystallography (SX) depends on efficient, continuous delivery of hydrated protein crystals while minimizing background scattering. Of the two major types of sample delivery devices, fixed-target devices offer several advantages over widely adopted jet injectors, including: lower sample consumption, clog-free delivery, and the ability to control on-chip crystal density to improve hit rates. In this study we present our development of versatile, inexpensive, and robust polymer microfluidic chips for routine and reliable room temperature serial measurements at both synchrotrons and X-ray free electron lasers (XFELs). Our design includes highly X-ray-transparent enclosing thin film layers tuned to minimize scatter background, adaptable sample flow layers tuned to match crystal size, and a large sample area compatible with both raster scanning and rotation based serial data collection. The optically transparent chips can be used both for in situ protein crystallization (to eliminate crystal handling) or crystal slurry loading, with prepared samples stable for weeks in a humidified environment and for several hours in ambient conditions. Serial oscillation crystallography, using a multi-crystal rotational data collection approach, at a microfocus synchrotron beamline (SSRL, beamline 12-1) was used to benchmark the performance of the chips. Furthermore, high-resolution structures (1.3–2.7 Å) were collected from five different proteins – hen egg white lysozyme, thaumatin, bovine liver catalase, concanavalin-A (type VI), and SARS-CoV-2 nonstructural protein NSP5. Overall, our modular fabrication approach enables precise control over the cross-section of materials in the X-ray beam path and facilitates chip adaption to different sample and beamline requirements for user-friendly, straightforward diffraction measurements at room temperature.

59 BASIC BIOLOGICAL SCIENCES↗

Measurement of the QE Map

113 MHz SRF gun utilized CsK 2 Sb and Na 2 KSb cathodes, which were irradiated with a pulsed green laser with a wavelength of 0.53 microns. The drive laser generated 78 kHz pulses with an acousto-optic modulator selecting the desired number of pulses reaching the cathode. The operator can select the aperture size, defining the laser spot diameter on the cathode, and the power level, which is controlled by a rotating polarizer. The laser power reaching the cathode can be measured with a meter based on a photodiode. The quantum efficiency (QE) of a photocathode serves as a primary indicator of its state. Small QE renders the cathode unusable when the desired bunch charge cannot be achieved. Strong variations in the quantum efficiency on the cathode surface might lead to the growth of the beam emittance due to the space charge effects. We have created a routine to measure the distribution of the QE on the cathode. The operator selects the aperture size, the central spot location, and the scan ranges for both planes. The scan starts from the central spots and proceeds along a spiral-like trajectory, making N rounds. The number of rounds can be chosen, and the total number of measured points is (2N+1) 2 . The laser spot movement is shown in Fig. 1.

43 PARTICLE ACCELERATORS↗

Towards Construction of a Novel Nanometer-Resolution MeV-STEM for Imaging Thick Frozen Biological Samples

Driven by life-science applications, a mega-electron-volt Scanning Transmission Electron Microscope (MeV-STEM) has been proposed here to image thick frozen biological samples as a conventional Transmission Electron Microscope (TEM) may not be suitable to image samples thicker than 300–500 nm and various volume electron microscopy (EM) techniques either suffering from low resolution, or low speed. The high penetration of inelastic scattering signals of MeV electrons could make the MeV-STEM an appropriate microscope for biological samples as thick as 10 μm or more with a nanoscale resolution, considering the effect of electron energy, beam broadening, and low-dose limit on resolution. The best resolution is inversely related to the sample thickness and changes from 6 nm to 24 nm when the sample thickness increases from 1 μm to 10 μm. To achieve such a resolution in STEM, the imaging electrons must be focused on the specimen with a nm size and an mrad semi-convergence angle. This requires an electron beam emittance of a few picometers, which is ~1000 times smaller than the presently achieved nm emittance, in conjunction with less than 10 -4 energy spread and 1 nA current. We numerically simulated two different approaches that are potentially applicable to build a compact MeV-STEM instrument: (1) DC (Direct Current) gun, aperture, superconducting radio-frequency (SRF) cavities, and STEM column; (2) SRF gun, aperture, SRF cavities, and STEM column. Beam dynamic simulations show promising results, which meet the needs of an MeV-STEM, a few-picometer emittance, less than 10 -4 energy spread, and 0.1–1 nA current from both options. Also, we designed a compact STEM column based on permanent quadrupole quintuplet, not only to demagnify the beam size from 1 μm at the source point to 2 nm at the specimen but also to provide the freedom of changing the magnifications at the specimen and a scanning system to raster the electron beam across the sample with a step size of 2 nm and the repetition rate of 1 MHz. This makes it possible to build a compact MeV-STEM and use it to study thick, large-volume samples in cell biology.

36 MATERIALS SCIENCE↗

Performance of Scintillation Detectors Based on Quantum Dots in a Semiconductor Matrix (Final Technical Report)

InAs Quantum Dots (QDs) embedded into GaAs semiconductor waveguide have unique scintillation properties, valuable for nuclear security, medical imaging, and high energy physics. In this work, we developed thick (~25um) epitaxial heterostructres with high luminescence efficiency composed of self-assembled nano-engineered InAs QDs grown by molecular beam epitaxy. In this type of detector, the GaAs matrix acts as a stopping material for charged particles or photons generating electrons captured by the QDs acting as luminescence centers. The QD medium is designed to provide fast capture of electrons into QDs (few ps), high QD luminescence efficiency at room temperature (>50%), and strong red-shift of photoluminescence (PL) from the GaAs absorption edge (>250nm). Typical devices consist of a 10-25um thick GaAs layer with embedded sheets of modulation p-type doped InAs QDs and an InGaAs photodetector tuned to the QD emission wavelength. The thick GaAs layer acts also as a waveguide when layer-transferred onto a low-index substrate. Waveguiding and self-absorption (~1cm -1 ) were studied using photoluminescence with scanning laser excitation and modeled with ray optics approximation and geometrical coupling of high-index waveguide to a collection fiber. Scintillating signals from α-particles were analyzed with both an external photodiode (PD) and an integrated PD which provided an improved optical coupling. In the former case, the external InGaAs PD was air-coupled to the scintillator and had the light collection efficiency of about 1% corresponding to limited light extraction through a planar interface with air due to total internal reflection. The mean charge collected by the integrated PD was in the range of (3÷5)×10 4 photoelectrons per 1 MeV of deposited energy, or ~13-20% of the theoretically achievable light yield. Timing of the integrated device was measured by wire-bonding it to the input of an 8 GHz IC. The scintillation response shows an extremely fast 0.3-0.6 ns decay constant and about 40-70 ps time resolution, limited by the system noise. The combined light yield and decay time makes the InAs/GaAs QD heterostructures the fastest high yield scintillation material reported making it valuable for high energy physics and medical imaging applications.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Polished diamond X-ray lenses

High-quality bi-concave 2D focusing diamond X-ray lenses of apex-radius R = 100 µm produced via laser-ablation and improved via mechanical polishing are presented here. Both for polished and unpolished individual lenses and for stacks of ten lenses, the remaining figure errors determined using X-ray speckle tracking are shown and these results are compared with those of commercial R = 50 µm beryllium lenses that have similar focusing strength and physical aperture. For two stacks of ten diamond lenses (polished and unpolished) and a stack of eleven beryllium lenses, this paper presents measured 2D beam profiles out of focus and wire scans to obtain the beam size in the focal plane. These results are complemented with small-angle X-ray scattering (SAXS) measurements of a polished and an unpolished diamond lens. Again, this is compared with the SAXS of a beryllium lens. The polished X-ray lenses show similar figure errors to commercially available beryllium lenses. While the beam size in the focal plane is comparable to that of the beryllium lenses, the SAXS signal of the polished diamond lenses is considerably lower.

47 OTHER INSTRUMENTATION↗

Seeing structural evolution of organic molecular nano-crystallites using 4D scanning confocal electron diffraction (4D-SCED)

Abstract Direct observation of organic molecular nanocrystals and their evolution using electron microscopy is extremely challenging, due to their radiation sensitivity and complex structure. Here, we introduce 4D-scanning confocal electron diffraction (4D-SCED), which enables direct in situ observation of bulk heterojunction (BHJ) thin films. 4D-SCED combines confocal electron optic setup with a pixelated detector to record focused spot-like diffraction patterns with high angular resolution, using an order of magnitude lower dose than previous methods. We apply it to study an active layer in organic solar cells, namely DRCN5T:PC 71 BM BHJ thin films. Structural details of DRCN5T nano-crystallites oriented both in- and out-of-plane are imaged at ~5 nm resolution and dose budget of ~5 e − /Å 2 . We use in situ annealing to observe the growth of the donor crystals, evolution of the crystal orientation, and progressive enrichment of PC 71 BM at interfaces. This highly dose-efficient method opens more possibilities for studying beam sensitive soft materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hard x-ray – optical four-wave mixing using a split-and-delay line

New, hard x-ray free electron lasers (FEL) produce intense femtosecond-to-attosecond pulses at angstrom wavelengths, giving access to the fundamental spatial and temporal scales of matter. These revolutionary light sources open the door to applying the suite of nonlinear, optical spectroscopy methods at hard x-ray photon energies. Nonlinear spectroscopy with hard x-rays can allow for measuring the coherence properties of short wavelength excitations with atomic specificity and for understanding how high energy excitations couple to other degrees of freedom in atomic, molecular or condensed-phase systems. As a step in this direction, here we present hard x-ray, optical four-wave mixing (4WM) measurements done at 9.8 keV at the split-and-delay line at the x-ray correlation spectroscopy (XCS) hutch of the Linac Coherent Light Source (LCLS). In this work, we create an x-ray transient grating (TG) from a pair of crossing x-ray beams and diffract optical laser pulses at 400 nm from the TG. The key technical advance here is being able to independently vary the delays of the x-ray pulses. Measurements were made in 3 different solid samples: bismuth germinate (BGO), zinc oxide (ZnO) and yttrium aluminum garnet (YAG). The resulting phase-matched, 4WM signal is measured in two different ways: by varying the x-ray, x-ray pulse delay which can reveal both material and light source coherence properties and also by varying the optical laser delay with respect to the x-ray TG to study how the x-ray excitation couples to the optical properties. Although no coherent 4WM signal was seen in these measurements, the absence of this signal gives important information on experimental requirements for detecting this in future work. Also, our laser-delay scans, although not a new measurement, were applied to different materials than in past work and reveal new examples x-ray induced lattice dynamics in solids. This work represents a key step towards extending nonlinear optics and time-resolved spectroscopy into the hard x-ray regime.

47 OTHER INSTRUMENTATION↗

Cryogen-free modular scanning tunneling microscope operating at 4-K in high magnetic field on a compact ultra-high vacuum platform

One of the daunting challenges in modern low temperature scanning tunneling microscopy (STM) is the difficulty of combining atomic resolution with cryogen-free cooling. Further functionality needs, such as ultra-high vacuum (UHV), high magnetic field (HF), and compatibility with μm-sized samples, pose additional challenges to an already ambitious build. We present the design, construction, and performance of a cryogen-free, UHV, low temperature, and high magnetic field system for modular STM operation. An internal vibration isolator reduces vibrations in this system, allowing for atomic resolution STM imaging while maintaining a low base temperature of ∼4 K and magnetic fields up to 9 T. Samples and tips can be conditioned in situ utilizing a heating stage, an ion sputtering gun, an e-beam evaporator, a tip treater, and sample exfoliation. In situ sample and tip exchange and alignment are performed in a connected UHV room temperature stage with optical access. Multisite operation without breaking vacuum is enabled by a unique quick-connect STM head design. A novel low-profile vertical transfer mechanism permits transferring the STM between room temperature and the low temperature cryostat.

Instruments & Instrumentation↗

Standoff Detection of Chemical Plumes Using Swept-ECQCL Remote Detection Technology: Results from EMRTC Complex Terrain Dual Tracer Experiment

As part of the Complex Terrain Dual Tracer Experiments performed in support of the LYNM program, a swept-wavelength external cavity quantum cascade laser (swept-ECQCL) remote detection system was deployed to measure chemical plume propagation with high temporal resolution. The swept-ECQCL remote detection technology was initially developed at PNNL, and is now under further development at Opticslah, LLC under SBIR funding from DOE (DOE SBIR Phase I Project DE-SC0019855, Remote Detection Technologies, Program Manager Chris Ramos). The swept-ECQCL technology provides a single-frequency infrared laser source which is rapidly scanned over a large wavelength range to measure the infrared absorption of gases, liquids, or solids. Analysis of the measured infrared absorption spectrum is used to detect, identify, and quantify the chemical species which are present. While most previous laser-based techniques used small wavelength tuning ranges to measure only a few isolated spectral lines of a few species, the swept-ECQCL provides the large tuning range needed to measure multiple species simultaneously, and to detect broad absorption features from large molecules or condensed phase materials. In addition, the swept-ECQCL systems have high enough spectral resolution and sensitivity to measure narrow lines of small molecules and determine isotope ratios. The remote detection system for gas plumes is based on the swept-ECQCL technology, and consists of a swept-ECQCL source, infrared detector, control electronics, and beam transmitting and alignment optics. The remote detection system directs the infrared output of the swept-ECQCL to a target retro reflector typically located at ~10-10,000 m distance. The swept-ECQCL wavelength is varied continuously over a large wavelength range (>1000 nm) at rates up to 1000 Hz. The swept ECQCL light reflected from the remote target is collected and focused onto an infrared photodetector. By measuring the detector signal continuously as the swept-ECQCL wavelength is varied, a time-series of absorption spectra are measured for the gases along the beam line of-sight. Based on analysis and fitting of the measured absorption spectra, the time-dependent chemical concentrations of species are determined. Multiple species and mixtures can be detected simultaneously, for all species with absorption features above the sensor noise floor. The sensor output is thus a continuous, high-speed record of identified chemicals along with their concentrations and isotope ratios of interest. The high-speed operation enables low-noise operation in conditions of atmospheric turbulence and allows tracking of fluctuating concentrations in transient chemical plumes as needed for reliable remote detection applications. All components operate with minimal cooling requirements and no cryogens are needed. In addition, the output infrared light is invisible with an intensity below the maximum permissible exposure (MPE) threshold of 100 mW/cm2 for these infrared wavelengths and thus eye safe. The measurement concept for plume detection using the swept-ECQCL remote detection system is as follows. The ECQCL beam is directed toward a remote retro-reflector, which reflects the beam back to the ECQCL system where it is focused onto an infrared photodetector. The line-of-sight from the ECQCL system to the retro-reflector defines the measurement path. The detected infrared signal is recorded continuously and detects the absorption of molecular species along the measurement path. Before a plume release, the system measures absorption from atmospheric constituents, which in this LWIR band consist primarily of lines from H 2 O and CO 2 , with additional weaker absorption from N 2 O, NH 3 , and O 3 possibly contributing. The system then measures any changes in absorption due to the tracer compounds when they enter the measurement path. The shape of absorption features is used to distinguish and identify the different tracer compounds, and the strength of the absorption is used to determine the path-integrated concentration – also called the column density.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Imaging nanoscale carrier, thermal, and structural dynamics with time-resolved and ultrafast electron energy-loss spectroscopy

Time-resolved and ultrafast electron energy-loss spectroscopy (EELS) is an emerging technique for measuring photoexcited carriers, lattice dynamics, and near-fields across femtosecond to microsecond timescales. When performed in either a specialized scanning transmission electron microscope or ultrafast electron microscope (UEM), time-resolved and ultrafast EELS can directly image charge carriers, lattice vibrations, and heat dissipation following photoexcitation or applied bias. Yet, recent advances in theoretical calculations and electron optics are often required to realize the full potential of ultrafast EEL spectrum imaging. Here, in this review, we present a comprehensive overview of the recent progress in the theory and instrumentation of time-resolved and ultrafast EELS. We begin with an introduction to the technique, followed by a physical description of the loss function. We outline approaches for calculating and interpreting ground-state and transient EEL spectra spanning low-loss plasmons to core-level excitations analogous to x-ray absorption. We then survey the current state of time-resolved and ultrafast EELS techniques beyond photon-induced near-field electron microscopy, highlighting abilities to image carrier and thermal dynamics. Finally, we examine future directions enabled by emerging technologies, including electron beam monochromation, in situ and operando cells, laser-free UEM, and high-speed direct electron detectors. These advances position time-resolved and ultrafast EELS as a critical tool for uncovering nanoscale dynamic processes in quantum materials and solar energy conversion devices.

Computational methods↗

Scattering-type Scanning Near-Field Optical Microscopy of Polymer-Coated Gold Nanoparticles

Scattering-type scanning near-field optical microscopy (s-SNOM) has emerged over the past years as a powerful characterization tool that can probe important properties of advanced materials and biological samples in a label-free manner, with spatial resolutions lying in the nanoscale realm. In this work, we explore such usefulness in relationship with an interesting class of materials: polymer-coated gold nanoparticles (NPs). As thoroughly discussed in recent works, the interplay between the Au core and the polymeric shell has been found to be important in many applications devoted to biomedicine. We investigate bare Au NPs next to polystyrenesulfonate (PSS) and poly(diallyldimethylammonium chloride) (PDDA) coated ones under 532 nm laser excitation, an wavelength matching the surface plasmon band of the custom-synthesized nanoparticles. We observe consistent s-SNOM phase signals in the case of bare and shallow-coated Au NPs, whereas for thicker shell instances, these signals fade. For all investigated samples, the s-SNOM amplitude signals were found to be very weak, which may be related to reduced scattering efficiency due to absorption of the incident beam. We consider these observations important, as they may facilitate studies and applications in nanomedicine and nanotechnology where the precise positioning of polymer-coated Au NPs with nanoscale resolution is needed besides their dielectric function and related intrinsic optical properties, which are also quantitatively available with s-SNOM.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Mesoscale atomic engineering in a crystal lattice

Controlling individual atoms using lasers, ion traps and scanning probe tips has transformed our understanding of matter and enabled breakthroughs in quantum science. Extending this control into three-dimensional (3D) solids and across mesoscopic scales, however, remains a foundational challenge. Electron irradiation in electron microscopes is known to induce atomic displacements, and atomic manipulation has been proposed and demonstrated. Yet repeated and deterministic control has remained elusive. Here, in this study, we demonstrate deterministic atomic engineering in a 3D crystal, creating ordered arrangements of more than 40,000 user-defined defects within minutes across a 150 nm × 100 nm × 13 nm volume. By steering individual Cr atoms in the magnetic semiconductor CrSBr into selected interstitial sites using an electron beam directed with sub-20-pm-scale accuracy, we create vacancy–interstitial complexes. The resulting impurity array forms a mesoscale crystal embedded within the host lattice, a new form of engineered artificial matter that remains stable at room temperature and outside the microscope. By tracking Cr atom displacements, we identify conditions under which the defect structures are predictable. Our calculations suggest that these defects form correlated impurity states with intra-defect optical transitions and inter-defect kinetic and Coulomb interactions. This establishes a generalizable platform for atomic defect engineering at mesoscopic, and potentially macroscopic, scales, opening opportunities for scalable quantum technologies, including deterministic colour-centre placement, quantum simulation of many-body lattice models and atomic-scale manufacturing.

74 ATOMIC AND MOLECULAR PHYSICS↗