Search NASA⌕ Search

SEARCH · Search NASA

Results for “OXYGEN CONSUMPTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Clinical applications of angiocardiography

Several tables are presented giving left ventricular (LV) data for normal patients and patients with heart disease of varied etiologies, pointing out the salient features. Graphs showing LV pressure-volume relationships (compliance) are presented and discussed. The method developed by Rackley et al. (1964) for determining left ventricular mass in man is described, and limitations to the method are discussed. Some clinical methods for determining LV oxygen consumption are briefly described, and the relation of various abnormalities of ventricular performance to coronary artery disease and ischemic heart disease is characterized.

Dodge, H. T.↗

Apollo experience report: Assessment of metabolic expenditures

A significant effort was made to assess the metabolic expenditure for extravehicular activity on the lunar surface. After evaluation of the real-time data available to the flight controller during extravehicular activity, three independent methods of metabolic assessment were chosen based on the relationship between heart rate and metabolic production, between oxygen consumption and metabolic production, and between the thermodynamics of the liquid-cooled garment and metabolic production. The metabolic assessment procedure is analyzed and discussed. Real-time use of this information by the Apollo flight surgeon is discussed. Results and analyses of the Apollo missions and comments concerning future applications are included.

Waligora, J. M.↗

Instrumented personal exercise during long-duration space flights

The present work reports the results of instrumented personal exercise performed in flight by Skylab 3 and 4 crewmen. Inflight cycle ergometer data provide conclusive evidence that man can perform earthbound equivalent maximum levels of physical work while in the zero-G environment. Moreover, SL4 crewmen were able to improve their physical condition during 84 days of space flight relative to launch condition, due to rigorous personal exercise regimens. Biological data measured included oxygen consumption, CO2 production, minute volume, and heart rate.

Sawin, C. F.↗

Physiological and biochemical characteristics of adrenergic receptors and pathways in brown adipocytes

Mechanisms involved in the thermogenic response of brown adipose tissue (BAT) to sympathetic nervous stimulation (e.g., by cold exposure) and to norepinephrine (NE) release are investigated. Three effects appear to play a role in the increased oxygen consumption (and heat production) of the adipocytes: increased membrane permeability, activation of the beta-adrenergic pathway, and enhancement of Na(+)/K(+) membrane pump activity. Increased passive influx of Na(+) and efflux of K(+) due to greater permeability raise the energy demands of the Na/K pump; the pump is also stimulated by increased cyclic AMP synthesis resulting from activation by NE of membrane-bound adenyl cyclase. Studies with inhibitors such as propanolol, phentolamine, and ouabain support this hypothesis.

Horwitz, B. A.↗

Exercise response

The bicycle ergometer and a graded stress protocol were used to conduct exercise stress tests for the Apollo project. The graded exercise tests permitted a progressive evaluation of physiological control system response and provided a better understanding of safe stress limits; heart rate was used for determining stress levels. During each test, workload, heart rate, blood pressure, and respiratory gas exchange (oxygen consumption, carbon dioxide production, and minute volume) measurements were made. The results are presented and discussed.

J.A. Rummel↗

Effects of water immersion to the neck on pulmonary circulation and tissue volume in man

A rapid noninvasive breathing method is used to obtain serial measurements of the pulmonary capillary blood flow, diffusing capacity per unit of alveolar volume, combined pulmonary tissue plus capillary volume, functional residual capacity, and oxygen consumption in five normal subjects undergoing 6 h of sitting, 4 h of sitting while immersed to the neck in thermoneutral water, and 4 h of lying in thermoneutral water to the neck. The rebreathing method employed a test gas mixture containing 0.5% C2H2, 0.3% C(18)O, 10% He, 21% O2, and balance N2. It is shown that immersion to the neck in the seated posture results in significant increases in sodium excretion cardiac output, and diffusing capacity per unit of alveolar volume. The pulmonary tissue plus capillary volume did not change, demonstrating that the central vascular engorgement induced by water immersion is not accompanied by significant extravasation of fluid into the pulmonary interstitial space.

Begin, R.↗

A role for glucose in hypothermic hamsters

Hypothermic hamsters at a rectal temperature of 7 C showed a fivefold increase in survival times from 20 to 100.5 hr when infused with glucose which maintained a blood level at about 45 mg/100 ml. A potential role for osmotic effects of the infusion was tested and eliminated. There was no improvement in survival of 3-O-methylglucose or dextran 40-infused animals. The fact that death eventually occurs even in the glucose-infused animal after about 4 days and that oxygen consumption undergoes a slow decrement in that period suggests that hypothermic survival is not wholly substrate limited. Radioactive tracer showed that localization of the C-14 was greatest in brain tissue and diaphragm, intermediate in heart and kidney, and lowest in skeletal muscle and liver. The significance of the label at sites important to respiration and circulation was presented.

Resch, G. E.↗

Metabolic and cardiovascular adaptation, monkey. NASA SMD 3, project 76, experiment 44 conducted at NASA/JSC, 14-25 May 1977

The biomedical results from an experiment on a monkey subjected to space flight conditions are reported. A background history of the development and testing of an experiment system designed to permit measurement of physiological parameters in subhuman primates during continuous, comfortable, couch restraint for periods of up to 30 days is reviewed. Of major importance in the experimental design of the system was the use of a fiberglass pod, which could be sealed and subdivided into upper and lower parts, to monitor and control the physiological responses for various parts of the animal's body. The experiment was conducted within the Spacelab Simulator for a period of 11 days. Data recorded includes: Spacelab Simulator cabin temperature; ventilation rate; pod internal temperature; fraction percent oxygen; fraction percent carbon dioxide; oxygen consumption rate; carbon dioxide production rate; respiratory quotient; intrathoracic temperature; heart rate; mean aortic pressure; mean ventricular pressure; diurnal variation of parameters measured; comparison of mean preflight, flight, and postflight values of the parameters measured; and correlation matrix for the parameters measured.

Pace, N.↗

Continuous metabolic and cardiovascular measurements on a monkey subject during a simulated 6-day Spacelab mission

A 10-kg male pig-tailed monkey (Macaca nemestrina) was selected as an optimal species for spaceflight studies on weightlessness. Three days before the simulated launch, the animal was placed in a fiberglass pod system to provide continuous measurement of respiratory gas exchange. Attention is given to examining the effects of weightlessness on several basic parameters of metabolic and cardiovascular function in an adult nonhuman primate. The 10.7-day total simulated-experiment period consisted of preflight 2.6 days, inflight 6.3 days, and postflight 1.8 days. Statistically significant diurnal variation was noted in oxygen consumption and CO2 production rates, body temperature and HR, but not in respiratory quotient or blood pressure. The high quality of the continuous data obtained demonstrates the feasibility of performing sound physiological experimentation on nonhuman primates in the Spacelab environment.

Pace, N.↗

Physical exercises on a bicycle-ergometer and running track to prevent hypodynamia in workers of intellectual labor

A program of exercises was developed and tested, consisting of a 12 minute session on a variable load bicycle ergometer and a 10-11 min. run with brief stretching and resting sessions between. Physical performance capacity was measured before, during, and after the period of the experiment and physical exams conducted. After a 4 month test period involving 30 men, aged 25-35, the program was found to be successful in increasing physical performance capacity. The PWC170 increased an average of 22 percent and maximum oxygen consumption 14 percent. Arterial pressure dropped (120/75 to 114/68), vital capacity of lungs increased by 6 percent, strength of respiratory muscles by 8.8 percent, duration of respiratory delay by 18 percent. Duration of cardiac cycles increased, stress index decreased. Cardiac contraction rate 2 minutes after work on the ergometer decreased from 118 to 102 bt/min.

Vasilyeva, V. V.↗

Simulated weightlessness - Effects on bioenergetic balance

As a prelude to a flight experiment, an attempt was made to separate energy requirements associated with gravity from all other metabolic needs. The biological effects of weightlessness were simulated by suspending animals in a harness so that antigravity muscles were not supporting the body. Twelve pairs of rats were allowed to adapt to wearing a harness for 5 d. Experimental animals were then suspended in harness for 7 d followed by recovery for 7 d. Control animals were harnessed but never suspended. Oxygen consumption, carbon dioxide production and rate of (C-14)O2 expiration from radio-labeled glucose were monitored on selected days. Food intake and body mass were recorded daily. Metabolic rate decreased in experimental animals during 7 d of suspension and returned to normal during recovery. Although some of the metabolic changes may have related to variation in food intake, simulated weightlessness appears to directly affect bioenergetic balance.

Jordan, J. P.↗

Na+ and Ca2+ ingestion - Plasma volume-electrolyte distribution at rest and exercise

The effects of hypernatremia and hypercalcemia on plasma volume and electrolyte distribution during rest, exercise and recovery in cool and hot environments are investigated. Plasma volume, protein and electrolytes were measured in two groups of five men in the supine position during rest, exercise at 40-47% maximal oxygen consumption and recovery in 26.5 C and 39.4 C environments, after ingestion in the rest period of 16-17 ml/kg hypertonic NaCl, isotonic NaCl or hypertonic calcium gluconate solutions. During the rest period, it is found that the hypertonic Ca drink prevents any rise in plasma volume in both cool and hot environments, while hypertonic Na retarded hypervolemia only in the cool environment and consumption of both isotonic and hypertonic Na in the heat resulted in a hypervolemic response twice as great as that in the cool environment. During exercise and recovery, plasma volume is found to be greatest after drinking hypertonic Na in the heat, while the normal hypervolemic responses during exercise were not influenced by drink composition. Results suggest that hypertonic drinks may be better for maintaining plasma volumes during exercise in the heat.

Greenleaf, J. E.↗

Altitude acclimatization. Citations from the International Aerospace Abstracts data base

This bibliography of citations to the international literature covers aspects of altitude acclimatization. Included are articles concerning high altitude environments, hypoxia, heart function and hemodynamic responses, physical exercise, human tolerances and reactions, physiological responses, and oxygen consumption. This updated bibliography contains 164 citations, 35 of which are new entries to the previous edition.

Mauk, S. C.↗

Metabolic rate measurement system

The Metabolic Rate Measurement System (MRMS) is an uncomplicated and accurate apparatus for measuring oxygen consumption and carbon dioxide production of a test subject. From this one can determine the subject's metabolic rate for a variety of conditions, such as resting or light exercise. MRMS utilizes an LSI/11-03 microcomputer to monitor and control the experimental apparatus.

Koester, K.↗

Scaling of metabolic rate on body mass in small laboratory mammals

The scaling of metabolic heat production rate on body mass is investigated for five species of small laboratory mammal in order to define selection of animals of metabolic rates and size range appropriate for the measurement of changes in the scaling relationship upon exposure to weightlessness in Shuttle/Spacelab experiment. Metabolic rates were measured according to oxygen consumption and carbon dioxide production for individual male and female Swiss-Webster mice, Syrian hamsters, Simonsen albino rats, Hartley guinea pigs and New Zealand white rabbits, which range in mass from 0.05 to 5 kg mature body size, at ages of 1, 2, 3, 5, 8, 12, 18 and 24 months. The metabolic intensity, defined as the heat produced per hour per kg body mass, is found to decrease dramatically with age until the animals are 6 to 8 months old, with little or no sex difference. When plotted on a logarithmic graph, the relation of metabolic rate to total body mass is found to obey a power law of index 0.676, which differs significantly from the classical value of 0.75. When the values for the mice are removed, however, an index of 0.749 is obtained. It is thus proposed that six male animals, 8 months of age, of each of the four remaining species be used to study the effects of gravitational loading on the metabolic energy requirements of terrestrial animals.

Pace, N.↗

Thermal oxidative degradation reactions of perfluoroalkylethers

The mechanisms operative in thermal oxidative degradation of Fomblin Z and hexafluoropropene oxide derived fluids and the effect of alloys and additives upon these processes are investigated. The nature of arrangements responsible for the inherent thermal oxidative instability of the Fomblin Z fluids is not established. It was determined that this behavior is not associated with hydrogen end groups or peroxy linkages. The degradation rate of these fluids at elevated temperatures in oxidizing atmospheres is dependent on the surface/volume ratio. Once a limiting ratio is reached, a steady rate appears to be attained. Based on elemental analysis and oxygen consumption data, CF2OCF2CF2O2, no. CF2CF2O, is one of the major arrangements present. The action of the M-50 and Ti(4 Al, 4 Mn) alloys is much more drastic in the case of Fomblin Z fluids than that observed for the hexafluoropropene derived materials. The effectiveness of antioxidation anticorrosion additives, P-3 and phospha-s-triazine, in the presence of metal alloys is very limited at 316 C; at 288 C the additives arrested almost completely the fluid degradation. The phospha-s-triazine appears to be at least twice as effective as the P-3 compound; it also protected the coupon better. The Ti(4 Al, 4 Mn) alloy degraded the fluid mainly by chain scission processes this takes place to a much lesser degree with M-50.

Paciorek, K. L.↗

The efficiency coefficient of the rat heart and muscular system after physical training and hypokinesia

The efficiency of an isolated heart did not change after prolonged physical training of rats for an extreme load. The increase in oxygen consumption by the entire organism in 'uphill' running as compared to the resting level in the trained rats was 14% lower than in the control animals. Prolonged hypokinesia of the rats did not elicit a change in the efficiency of the isolated heart.

Alyukhin, Y. S.↗

Thermal oxidative degradation reactions of linear perfluoroalky lethers

Thermal and thermal oxidative stability studies were performed on linear perfluoro alkyl ether fluids. The effect on degradation by metal catalysts and degradation inhibitors are reported. The liner perfluoro alkylethers are inherently unstable at 316 C in an oxidizing atmosphere. The metal catalysts greatly increased the rate of degradation in oxidizing atmospheres. In the presence of these metals in an oxidizing atmosphere, the degradation inhibitors were highly effective in arresting degradation at 288 C. However, the inhibitors had only limited effectiveness at 316 C. The metals promote degradation by chain scission. Based on elemental analysis and oxygen consumption data, the linear perfluoro alkylether fluids have a structural arrangement based on difluoroformyl and tetrafluoroethylene oxide units, with the former predominating.

Jones, W. R., Jr.↗