Search NASA⌕ Search

SEARCH · Search NASA

Results for “Open Air Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Validation Data Acquisition in HTTF during PCC Events

A validation experimental campaign was conducted in an Integral Effect Test (IET) facility of High Temperature Gas Reactors (HTGR), the High-Temperature Test Facility (HTTF) at Oregon State University (OSU). The HTTF simulates Depressurized and Pressurized Conduction Cooldowns (DCC and PCC). This campaign required the development of a new laser spectroscopic diagnostic to measure velocity in the challenging conditions of the HTTF: low speed (~1 m/s) gas flows at HTGR prototypical temperature and 1/10th pressure. This was a collaborative effort between co-PIs at The George Washington University (GW), Oregon State University (OSU), and NASA Langley Research Center. The main accomplishments of this project include the record for dynamic range for velocimetry, highest accuracy obtained with this technique, successful deployment in an IET leading to new validation matrix for CFD. These are detailed below and in manuscript appended to this executive summary. For this project, we introduced a new class of laser spectroscopic diagnostics to Thermal-Hydraulics to measure velocity of gases; furthermore, the diagnostic was demonstrated in-situ in an IET during DCC events. In such scenarios, particles used in mainstream techniques, like Particle Image Velocimetry (PIV) are not appropriate as they settle down too rapidly and also contaminate the experimental facility. Molecular tracers stay mixed within the working gas and can seed the flow in a technique called Molecular Tagging Velocimetry (MTV). In MTV a molecular tracer is photo-dissociated by a first (write) laser into radicals or molecules. The pattern created by the write laser is then interrogated with planar laser-induced fluorescence (PLIF), the read pulse(s), which are recorded with a camera. The pattern is probed and matched at two times (interval or probe time, dt), resulting in a time-of-flight velocimetry technique. This project demonstrated a new application range for MTV in gases. MTV has been extensively used for high-speed gas dynamics: molecules do not suffer from inertia associated with particles in regions of high accelerations (such as shock waves). For high-speed flows, the probe time is on the order of 0.1-10 µs. In time-of-flight techniques, the velocity is reconstructed from the recorded displacement, dx, between time interval dt: U = dx/dt. To first order, the resolution of the pattern matching is typically a (fixed) fraction of a pixel; therefore the resolution of the velocity measurement increases with dx and, for a given flow velocity, dt. For the low-speed flows of interest here, this requires long probe time, and therefore finding tracers that are stable for a long time. After an extensive literature survey we identified 6 tracers that would be suitable. We also worked with Spectra Physics to design a custom laser system that is flexible enough to probe these various tracers. The final instrument is made of 4 lasers that are integrated into a compact and movable cart to facilitate the deployment of the instrument off-site. One unique aspect of the laser system is the tunable dye laser (needed to do PLIF of the radicals). By being pumped by two Nd:YAG lasers, this laser is able to provide two pulses with any probe time (dt) for wavelengths between 200 and 900 nm with a linewidth of 3 pm. Accommodating the dual-pulse capability required customizing the pump lasers and the dye laser, making this system unique. Additionally, a custom UV-intensified CCD camera capable of frame-straddling and exposure time as short as 10 ns was acquired. More than two-third of the instrument cost (~$200k) was covered by a cost sharing from the PI’s startup funds. Of the 6 potential tracers identified, two were tested extensively (H2O and N2O) at high-temperature and elevated pressure at GW prior to conducting the tests at OSU. For both tracers, an Ar-F laser (193 nm, 10 ns, 10 mJ/pulse) photo-dissociates trace amounts (0.1 – 5% molar fraction) of the gases into OH and NO. OH is probed at 281.905 nm and NO at 226.186 nm (4-30mJ, 10 ns pulse). NO is very stable in inert environment and we could reconstruct velocities precisely with probe delay times as long at 40 ms, compared to 2 ms for OH, resulting in increased precision. Therefore, for the tests in the HTTF, N2O was selected as the final tracer and its optimal concentration was determined to be 0.5% molar. In the GW laboratory, we obtained a velocity measurement precision of 4 mm/s at conditions mimicking the HTTF tests. We also demonstrated the benefit of molecular tracers over particles and the flexibility of our instrument by continuously measuring velocity from 1000 to 0.1 m/s in a blow down test. This represents a dynamic range on velocity of 80 dB, which is unprecedented for velocimetry! Once the diagnostic was optimized, two two-week campaigns were conducted in the HTTF. This experimental campaign required numerous practical solutions to successfully and rapidly deploy this very sensitive table-top diagnostic in-situ. This was accomplished thanks to very extensive planning from all parties involved in the project. Due to constraints on availability of the HTTF, only adiabatic DCC tests were conducted. Specifically, the velocity was measured at the exit of the hot leg into the Reactor Cavity Simulation Tank (RCST). We were able to record the gas velocity associated with the air ingress for long times (up to one hour). Depending on the initial conditions (density of the gases in the Reactor Pressure Vessel and the RCST) the lock exchange lasted 30-60 s past the valve openings. Large vortices were identified within the shear layer at the interface of the cross flow. These vortices are an indication of shear-driven instability between the counter streams of different density. After the lock-exchange, a small residual flow was still present and its strength decayed exponentially. It finds its source in a buoyancy difference between the gases in both vessels due to the mixing and diffusion of the gases in the cross-over duct and the RPV lower plenum. We did not expect to capture this part of the transient, which would have been less significant (if not negligible) in the presence of a heated core; the precision of our measurement in the HTTF was 6 mm/s, which exceeded our expectations for such a complex test! Using commercial software (Fluent) we simulated the experiment with Computational Fluid Dynamic (CFD) using Reynolds Averaged Navier-Stokes (RANS) turbulence models. We were not able to accurately reproduce the shear layer instability, mixing, and diffusion captured in our experimental data, even with large 3D meshes (>10 M points). We attributed this to the inadequacy of the RANS models for the flow of interest: our experimental Reynolds number was too low and was outside the applicability range of the RANS models. Instead, we should have employed CFD with less modeling, such as Large Eddy (LES) or even Direct Numerical (DNS) simulations. Unfortunately, we did not have the computational resources to do so. Finally, it should be noted that this experimental technique holds great promises for measuring velocity in thermalhydraulics. MTV has an application domain (highlighted in the narrative) that is complimentary to more established (and simpler) techniques, such as PIV. It has attracted the attention of several thermalhydraulics researchers and sponsors to measure velocity in harsh environments. The spectroscopic nature of this technique also enables to expand it to measure temperature and concentration simultaneously to velocity. In lieu of a narrative, 4 detailed journal publications are appended to this executive summary to describe the various development and accomplishments during this project. They include 2 published manuscripts (Experiments in Fluids and Measurement Science and Technology), and two invited contributions following the NURETH-17 conference (Nuclear Science and Technology). Our current Nuclear Engineering and Design draft is not included at this time.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Tracer gas test in Net-Zero Energy Residential Test Facility

The Net-Zero Energy Residential Test Facility (NZERTF) at NIST was built in 2012 to support the development and adoption of cost-effective net-zero energy designs, technologies, and construction methods. It is two-story, and has four bedrooms, three bathrooms, and an open living room, dining room, and kitchen space. The NZERTF also has a basement and attic, both located within the conditioned space because the thermal and air-moisture barriers encompass the basement walls and attic roof. Transfer grilles link the living spaces to these two zones. The central heating and cooling system includes an air-toair heat pump, which delivers air to the basement, first and second floors. The heat pump has a cooling capacity of 7.6 kW and a heating capacity of 7.8 kW. The indoor unit is in the basement and ductwork runs along the basement ceiling. A balanced heat recovery ventilator (HRV) is installed in the basement and has its own dedicated ductwork. The HRV supplies 47 L/s of outdoor air to the house, with supplies on the first floor (in the kitchen/dining area) and in each of the three second-floor bedrooms. Air from the first-floor bathroom and both second-floor bathrooms is returned to the HRV before being exhausted, though the HRV was turned off during the tests. The house also has a range hood exhaust and a clothes dryer exhaust, both of which were turned off for the tests. The temperature of the house was measured and the operation of the space conditioning system, including its recirculating air distribution fan, were controlled by a commercially available thermostat.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Topography and canopy cover influence soil organic carbon composition and distribution across a forested hillslope in the discontinuous permafrost zone

This dataset contains data used for the paper "Topography and canopy cover influence soil organic carbon composition and distribution across a forested hillslope in the discontinuous permafrost zone". The Related References field will be updated with a full citation when available. Topography and canopy cover influence ground temperature in warming permafrost landscapes, yet soil temperature heterogeneity introduced by meso-topographic slope positions, microtopographic differences in vegetation cover, and the subsequent impact of contrasting temperature conditions to soil organic carbon (SOC) dynamics are understudied. Buffering of permafrost-affected soils against warming air temperatures in boreal forests can reflect surface soil characteristics (e.g., thickness of organic material) as well as the degree and type of canopy cover (e.g., open cover vs closed cover). Both landscape and soil properties interact to determine meso- and micro-scale heterogeneity of ground warming. We sampled a hillslope catena transect in a discontinuous permafrost zone near Fairbanks, Alaska to test the small-scale (1 to 3 meter) impacts of slope position and cover type on soil organic matter composition. Mineral active layer samples were collected from backslope, low backslope, and footslope positions at depths spanning 19 to 60 cm. We examined soil mineralogical composition, soil moisture, total carbon and nitrogen content, and organic mat thickness in conjunction with an assessment of SOC composition using Fourier-transform ion Cyclotron Resonance Mass Spectrometry (FT-ICR-MS). Soils in the footslope position had a higher relative contribution of lignin-like compounds while backslope soils had more aliphatic and condensed aromatic compounds as determined by FT-ICR-MS. The effect of open versus closed tree canopy cover varied with slope position. On the backslope, we found higher oxidation of molecules under open cover compared with closed cover, indicating an effect of warmer soil temperature on decomposition. Little to no effect of canopy was observed for soils at the footslope position, which we attributed, in part, to the strong impact of soil moisture content in SOC dynamics in the water-gathering footslope position. The thin organic mat under open cover on the backslope position may have contributed to differences in soil temperature and thus SOC oxidation under open and closed canopy. Here, the thinner organic mat did not appear to buffer the underlying soil against warm season air temperatures and thus increased SOC decomposition as indicated by higher oxidation of SOC molecules and a lower contribution of simple molecules under open cover compared with the closed canopy sites. Our findings suggest that the role of canopy cover in SOC dynamics varies as a function of landscape position and soil properties, namely organic mat thickness and soil moisture. Condition-specific heterogeneity of SOC composition under open and closed canopy cover highlights the protective effect of canopy cover for soils on backslope positions. This dataset contains a compressed (.zip) archive of the data and R scripts used for this manuscript. The dataset includes files in .csv format, which can be accessed and processed using MS Excel or R. This archive can also be accessed on GitHub at https://github.com/Erin-Rooney/Y1_fairbanks (DOI: 10.5281/zenodo.8071247).

54 ENVIRONMENTAL SCIENCES↗

Field Testing of an Unvented Roof with Fibrous Insulation, Tiles and Vapor Diffusion Venting

This research is a test implementation of an unvented tile roof assembly in a hot-humid climate (Orlando, FL; Zone 2A), insulated with air permeable insulation (netted and blown fiberglass). Given the localized moisture accumulation and failures seen in previous unvented roof field work, it was theorized that a 'diffusion vent' (water vapor open, but air barrier 'closed') at the highest points in the roof assembly might allow for the wintertime release of moisture, to safe levels. The 'diffusion vent' is an open slot at the ridge and hips, covered with a water-resistant but vapor open (500+ perm) air barrier membrane. As a control comparison, one portion of the roof was constructed as a typical unvented roof (self-adhered membrane at ridge). The data collected to date indicate that the diffusion vent roof shows greater moisture safety than the conventional, unvented roof design. The unvented roof had extended winter periods of 95-100% RH, and wafer (wood surrogate RH sensor) measurements indicating possible condensation; high moisture levels were concentrated at the roof ridge. In contrast, the diffusion vent roofs had drier conditions, with most peak MCs (sheathing) below 20%. In the spring, as outdoor temperatures warmed, all roofs dried well into the safe range (10% MC or less). Some roof-wall interfaces showed moderately high MCs; this might be due to moisture accumulation at the highest point in the lower attic, and/or shading of the roof by the adjacent second story. Monitoring will be continued at least through spring 2016 (another winter and spring).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Field Testing of an Unvented Roof with Fibrous Insulation, Tiles, and Vapor Diffusion Venting

This research is a test implementation of an unvented tile roof assembly in a hot-humid climate (Orlando, FL; Zone 2A), insulated with air permeable insulation (netted and blown fiberglass). Given the localized moisture accumulation and failures seen in previous unvented roof field work, it was theorized that a 'diffusion vent' (water vapor open, but air barrier 'closed') at the highest points in the roof assembly might allow for the wintertime release of moisture, to safe levels. The 'diffusion vent' is an open slot at the ridge and hips, covered with a water-resistant but vapor open (500+ perm) air barrier membrane. As a control comparison, one portion of the roof was constructed as a typical unvented roof (self-adhered membrane at ridge). The data collected to date indicate that the diffusion vent roof shows greater moisture safety than the conventional, unvented roof design.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building America Case Study: Field Testing an Unvented Roof with Fibrous Insulation and Tiles, Orlando, Florida

This research is a test implementation of an unvented tile roof assembly in a hot-humid climate (Orlando, FL; Zone 2A), insulated with air permeable insulation (netted and blown fiberglass). Given the localized moisture accumulation and failures seen in previous unvented roof field work, it was theorized that a 'diffusion vent' (water vapor open, but air barrier 'closed') at the highest points in the roof assembly might allow for the wintertime release of moisture, to safe levels. The 'diffusion vent' is an open slot at the ridge and hips, covered with a water-resistant but vapor open (500+ perm) air barrier membrane. As a control comparison, one portion of the roof was constructed as a typical unvented roof (self-adhered membrane at ridge). The data collected to date indicate that the diffusion vent roof shows greater moisture safety than the conventional, unvented roof design. The unvented roof had extended winter periods of 95-100% RH, and wafer (wood surrogate RH sensor) measurements indicating possible condensation; high moisture levels were concentrated at the roof ridge. In contrast, the diffusion vent roofs had drier conditions, with most peak MCs (sheathing) below 20%. In the spring, as outdoor temperatures warmed, all roofs dried well into the safe range (10% MC or less). Some roof-wall interfaces showed moderately high MCs; this might be due to moisture accumulation at the highest point in the lower attic, and/or shading of the roof by the adjacent second story. Monitoring will be continued at least through spring 2016 (another winter and spring).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Causal Interactions between Southern Ocean Polynyas and High-Latitude Atmosphere–Ocean Variability

Abstract Weddell Sea open-ocean polynyas have been observed to occasionally release heat from the deep ocean to the atmosphere, indicating that their sporadic appearances may be an important feature of high-latitude atmosphere–ocean variability. Yet, observations of the phenomenon are sparse and many standard-resolution models represent these features poorly, if at all. We use a fully coupled, synoptic-scale preindustrial control simulation of the Energy Exascale Earth System Model (E3SMv0-HR) to effectively simulate open-ocean polynyas and investigate their role in the climate system. Our approach employs statistical tests of Granger causality to diagnose local and remote drivers of, and responses to, polynya heat loss on interannual to decadal time scales. First, we find that polynya heat loss Granger causes a persistent increase in surface air temperature over the Weddell Sea, strengthening the local cyclonic wind circulation. Along with responding to polynyas, atmospheric conditions also facilitate their development. When the Southern Ocean experiences a rapid poleward shift in the circumpolar westerlies following a prolonged negative phase of the southern annular mode (SAM), Weddell Sea salinity increases, promoting density destratification and convection in the water column. Finally, we find that the reduction of surface heat fluxes during periods of full ice cover is not fully compensated by ocean heat transport into the high latitudes. This imbalance leads to a buildup of ocean heat content that supplies polynya heat loss. These results disentangle the complex, coupled climate processes that both enable the polynya’s existence and respond to it, providing insights to improve the representation of these highly episodic sea ice features in climate models.

Kaufman, Zachary S.↗

Predictive LES Modeling and Validation of High-Pressure Turbulent Flames and Flashback in Hydrogen-enriched Gas Turbines

The overall objective of this project is to make advances in large-eddy simulation modeling of swirl-flame flashback at elevated pressure, where the reactants can be premixed or stratified, and composed of methane enriched with hydrogen. The modeling effort was conducted with a companion experimental validation effort that focused on high-speed measurements of flashback in a model swirl-flame combustor. The modeling effort focused on the development of manifold-based combustion model for flashback simulations. The main complexity in this configuration comes from the flames’ propagation through a stratified fuel-air mixture along with heat loss near the walls. For this purpose, a non-adiabatic flamelet model was developed and tested using canonical flow configurations. Further, extensive validation in premixed configurations is used to establish the model’s accuracy in capturing heat loss and flame propagation. Finally, the model was tested using the UT flame flashback experiment, and was shown to accurately capture the flame flashback process. The end products from this work are a) a full validated flameout-based approach for modeling flame flashback; b) a complete implementation of the model in the open source OpenFOAM framework, which has been made available to both industry and academia; c) an extensive suite of validation studies performed using the OpenFOAM solver. In addition, new techniques for flame modeling, subfilter modeling of scalars, and simulation of low Mach number flows were developed and tested. In the experimental validation effort, flashback was studied in a premixed and stratified swirl flame by using high-speed imaging diagnostics. Fuels tested included CH 4 enriched with H 2 , with H 2 enrichment up to 84% by volume. These flashback experiments are conducted at pressures ranging from 1 to 5 atm. A swirler-based fuel-injection system was used to create the fuel-air stratification in the radial direction. For the high-pressure measurements, an optically accessible elevated pressure chamber was used. The spatial distribution of the equivalence ratio under non-reacting conditions was characterized using planar laser-induced fluorescence with acetone as the fuel tracer. It was observed that fuel-air pockets were distributed across the mixing tube width, although in an average sense, the fuel-air mixture was radially stratified. The global behavior of upstream flame propagation was investigated for different levels of hydrogen-enrichment. For stratified hydrogen-rich flashback, the propagation path of the flame changed from the inner wall to outer wall, which was induced by the faster chemistry of stoichiometric mixtures that are frequently present near the outer wall. This behavior of hydrogen-rich flashback persists even at elevated pressures up to 5 atm, although the propagation of the flame occurs as a wide flame tongue as opposed to the acute-tipped flame structures present in the atmospheric cases. The end product of the experimental effort is greatly improved knowledge of flashback physics and a unique database that can be used for model validation.

08 HYDROGEN↗

Avian community composition in response to high explosive testing operations at Los Alamos National Laboratory in Northern New Mexico

Breeding bird abundance, species richness, evenness, diversity, composition, productivity, and survivorship were determined near a high-explosive detonation site at Los Alamos National Laboratory, New Mexico, USA, during pre-operation (1997-1999) and operation (2000-2014) periods. The operation periods consisted of detonations (<23 kg in yield and <3 per breeding season) in open air (2000-2002), within foam containment (2003-2006) and within steel vessel containment (2007-2014) systems; the latter two were employed to reduce noise and dispersal of high-explosives residues. A total of 2952 bird captures, representing 80 species, was recorded during 18 years of mist net operations using the Monitoring Avian Productivity and Survivorship protocol. Individuals captured were identified to species, aged, sexed, and banded during May through August of each year. There were no significant differences (p > 0.05) in mean avian abundance and species evenness in any of the operation periods as compared with the pre-operation period. Species richness and diversity were significantly higher (p < 0.05) during the vessel containment period (2007-2014) than the pre-operation period. The time period of this study coincided with a wildfire (2000), a bark beetle infestation (2002), and two periods of drought (Nov 1999-Mar 2004 and Dec 2005-Dec 2014) that affected the study area. Furthermore, analysis of aerial photos determined that the average percent canopy cover of mature ponderosa pines (Pinus ponderosa) within 100 feet of mist net sites declined from 12% to 3% between 1991 and 2014 and the percent cover of shrubs slightly increased.

54 ENVIRONMENTAL SCIENCES↗

Effect of microstructure and temperature on nuclear graphite oxidation using the 3D Random Pore Model

This work compared the 3D Random Pore Model (3D-RPM) with experimental and characterization data to systematically study the effect of nuclear graphite microstructure and air oxidation temperature. It is well known that oxidation-induced weight loss at elevated temperatures degrades graphite structure and properties; however, a fundamental understanding of the role of graphite microstructure is still unclear. In this work, three diverse grades of nuclear graphite—IG-110, NBG-18, and PCEA—were examined and tested at air oxidation temperatures of 600, 650, 700, and 750 °C following ASTM D7542. Here, the 3D-RPM reproduced the microstructure and temperature dependence of mass loss curves for these grades. For the first time, measurements and modeling were combined to show how bulk density and the amount and spatial distribution of open and closed porosity affects oxidation. IG-110 was less dense and had an open pore network that is finer and more uniformly spread, and showed fastest oxidation. PCEA porosity was less uniform and showed less oxidation, while NBG-18 was more dense, had the least fine and uniform porosity, and showed the slowest oxidation. In general, oxidation proceeds faster if open porosity is more uniformly distributed and can incrementally access closed pore surface area with more ease.

36 MATERIALS SCIENCE↗

Using E-PRTR data on point source emissions to air and water—First steps towards a national chemical footprint

There is a great need for indicators to monitor the use and potential impacts of hazardous chemicals. Today there is a huge lack of data, methods and results and method development and studies should be given urgent priority. The aim of this paper was to develop and test an approach to calculate the potential environmental impacts of chemicals for a whole country using the E-PRTR (European Pollutant Release and Transfer Register) as a database and Sweden as an example. Swedish data from 2008 on emissions to air and water for 54 substances from point sources were retrieved from an open database. The data were transformed and aggregated using USEtox, a life-cycle impact assessment (LCIA) method for calculating potential human toxicity and ecotoxicity, both from industrial emissions directly and after input–output analysis (IO analysis) to reallocate emissions to product categories. Zinc to air and water contributed most to human toxicity followed by mercury to air. The largest contribution by industry to potential human toxicity came from the metal industry, followed by the paper and paper product industry. For potential ecotoxicity, zinc, fluoranthene and copper contributed the most. The largest contributions by industry came from the paper and paper products manufacturing sector, followed by the basic metals manufacturing sector. The approach used here can be seen as the first step towards a chemical footprint for nations. By adding data from other countries and other sources, a more complete picture can be gained in line with other footprint calculations. Furthermore, diffuse emissions from, for example, transport or emissions of pesticides could also be added for a more holistic assessment. Since the area of chemicals is complicated, it is probably necessary to develop and use several indicators that complement each other. It is suggested that the approach outlined here could be useful in developing a method for establishing a national chemical footprint. - Highlights: • European Pollutant and Transfer Register (E-PRTR) used to develop indicators • Study combined emissions to air and water from E-PRTR with USEtox and IO analysis • Metals and especially zinc contributed most to potential human toxicity and ecotoxicity • Paper and metal industries contribute most to potential human toxicity and ecotoxicity • This new assessment could be used by many countries and can be developed further.

54 ENVIRONMENTAL SCIENCES↗

Performance of a Laser Ignited Multicylinder Lean Burn Natural Gas Engine

Market demands for lower fueling costs and higher specific powers in stationary natural gas engines has engine designs trending towards higher in-cylinder pressures and leaner combustion operation. However, Ignition remains as the main limiting factor in achieving further performance improvements in these engines. Addressing this concern, while incorporating various recent advances in optics and laser technologies, laser igniters were designed and developed through numerous iterations. Final designs incorporated water-cooled, passively Q-switched, Nd:YAG micro-lasers that were optimized for stable operation under harsh engine conditions. Subsequently, the micro-lasers were installed in the individual cylinders of a lean-burn, 350 kW, inline 6-cylinder, open-chamber, spark ignited engine and tests were conducted. To the best of our knowledge, this is the world’s first demonstration of a laser ignited multi-cylinder natural gas engine. The engine was operated at high-load (298 kW) and rated speed (1800 rpm) conditions. Ignition timing sweeps and excess-air ratio (λ) sweeps were performed while keeping the NOx emissions below the USEPA regulated value (BSNOx < 1.34 g/kW-hr), and while maintaining ignition stability at industry acceptable values (COV_IMEP <5 %). Through such engine tests, the relative merits of (i) standard electrical ignition system, and (ii) laser ignition system were determined. In conclusion, a rigorous combustion data analysis was performed and the main reasons leading to improved performance in the case of laser ignition were identified.

33 ADVANCED PROPULSION SYSTEMS↗

Addressing a systematic bias in carbon dioxide flux measurements with the EC150 and the IRGASON open-path gas analyzers

Across a global network of eddy covariance flux towers, two relatively new open-path infrared gas analyzers (IRGAs), the IRGASON and the EC150, are increasingly used to measure net carbon dioxide (CO 2 ) fluxes (F c_OP ). Differences in net CO 2 fluxes derived from open- and closed-path IRGAs in general remain poorly constrained. In particular, the performance of the IRGASON and the EC150 for measuring F c_OP has not been characterized yet. These IRGAs measure CO 2 absorption, which is scaled with air temperature and pressure before converting it to instantaneous CO 2 density. This sensor-internal conversion is based on a slow-response thermistor air temperature measurement. In this paper, we test if the high-frequency temperature attenuation causes selectively systematic F c_OP errors that scale with kinematic temperature fluxes. First, we examine the relationship between wintertime F c_OP and kinematic temperature fluxes for eight northern ecosystems. Second, we investigate how residuals between F c_OP and CO 2 fluxes from co-located closed-path IRGAs (F C_CP ) are related to kinematic temperature fluxes for three different ecosystem types (i.e., boreal forest, grassland, and irrigated cropland). We find that kinematic temperature fluxes, but not mean ambient air temperatures or CO 2 flux regime, consistently determine the absolute magnitude of F c_OP errors. This selectively systematic bias causes the most pronounced relative F c_OP errors to occur when “true” CO 2 fluxes are low and kinematic temperature fluxes are high (e.g., northern ecosystems during the winter). The smallest relative errors occur during periods with large “true” CO 2 fluxes and low kinematic temperature fluxes. To address this bias, we replace the slow-response air temperature in the absorption-to-CO 2 density conversion with a fast-response air temperature derived from sonic anemometer measurements. The use of the fast-response air temperature improves the agreement between half-hourly F c_OP and F C_CP for all open- versus closed-path IRGA comparisons. Additionally, cumulative F c_OP and F c_CP sums are more comparable as differences drop from 63 %–13 % to 20 %–8 %. Finally, the improved IRGASON and EC150 performance enhances the ability and confidence to synthesize flux measurements across multiple sites including these two relatively new IRGAs.

47 OTHER INSTRUMENTATION↗

Occurrence of vancomycin-resistant and -susceptible Enterococcus spp. in reclaimed water used for spray irrigation

Reclaiming municipal wastewater for agricultural, environmental, and industrial purposes is increasing in the United States to combat dwindling freshwater supplies. However, there is a lack of data regarding the microbial quality of reclaimed water. In particular, no previous studies have evaluated the occurrence of vancomycin-resistant enterococci (VRE) in reclaimed water used at spray irrigation sites in the United States. To address this knowledge gap, we investigated the occurrence, concentration, and antimicrobial resistance patterns of VRE and vancomycin-susceptible enterococci at three U.S. spray irrigation sites that use reclaimed water. We collected 48 reclaimed water samples from one Mid-Atlantic and two Midwest spray irrigation sites, as well as their respective wastewater treatment plants, in 2009 and 2010. Samples were analyzed for total enterococci and VRE using standard membrane filtration. Isolates were purified and then confirmed using biochemical tests and PCR. Antimicrobial susceptibility testing was conducted using the Sensititre® microbroth dilution system. Data were analyzed by two-sample proportion tests and one-way analysis of variance. We detected total enterococci and VRE in 71% (34/48) and 4% (2/48) of reclaimed water samples, respectively. Enterococcus faecalis was the most common species identified. At the Mid-Atlantic spray irrigation site, UV radiation decreased total enterococci to undetectable levels; however, subsequent storage in an open-air pond at this site resulted in increased concentrations of enterococci. E. faecalis isolates recovered from the Mid-Atlantic spray irrigation site expressed intrinsic resistance to quinupristin/dalfopristin; however, non-E. faecalis isolates expressed resistance to quinupristin/dalfopristin (52% of isolates), vancomycin (4%), tetracycline (13%), penicillin (4%) and ciprofloxacin (17%). Our findings show that VRE are present in low numbers in reclaimed water at point-of-use at the sampled spray irrigation sites; however, resistance to other antimicrobial classes is more prevalent, particularly among non-E. faecalis isolates. - Highlights: • Enterococci were recovered in 71% of reclaimed water samples. • Vancomycin-resistant enterococci were detected in 4% of reclaimed water samples. • UV radiation at irrigation sites reduced enterococci to undetectable levels. • Storage of reclaimed water in open-air ponds increased levels of enterococci.

54 ENVIRONMENTAL SCIENCES↗

Reference Model 6 Cost Breakdown (RM6: Oscillating Water Column)

Contains the Reference Model 6 (RM6) spreadsheets with the cost breakdown structure (CBS) for the levelized cost of energy (LCOE) calculations for a single RM6 device and multiple unit arrays. These spreadsheets are contained within an XLSX file and a spreadsheet editor such as Microsoft Excel is needed to open the file. This data was generated upon completion of the project on September 30, 2014. The Reference Model Project (RMP), sponsored by the U.S. Department of Energy (DOE), was a partnered effort to develop open-source MHK point designs as reference models (RMs) to benchmark MHK technology performance and costs, and an open-source methodology for design and analysis of MHK technologies, including models for estimating their capital costs, operational costs, and levelized costs of energy. The point designs also served as open-source test articles for university researchers and commercial technology developers. The RMP project team, led by Sandia National Laboratories (SNL), included a partnership between DOE, three national laboratories, including the National Renewable Energy Laboratory (NREL), Pacific Northwest National Laboratory (PNNL), and Oak Ridge National Laboratory (ORNL), the Applied Research Laboratory of Penn State University, and Re Vision Consulting. Reference Model 6 (RM6) is a Backward Bent Duct Buoy (BBDB), which is a type of oscillating water column wave energy converter. First proposed by Masuda, the BBDB design is a floating Oscillating Water Column (OWC) device that consists of an air chamber, an L-shaped duct, bow and stern buoyancy modules, and a power take-off (PTO) composed of a Wells air turbine and a generator. This L- shaped device opens to the ocean downstream from the wave propagation direction. Power is produced by the motion of the wave, which causes the ambient pressure in the air chamber to vary thereby forcing air to flow through the Wells turbine. The reference wave energy resource for RM6 was developed from site information collected near Eureka, in Humboldt County, California.

16 TIDAL AND WAVE POWER↗

Reference Model 6 Full Scale Geometry (RM6: Oscillating Water Column)

Contains the Reference Model 6 (RM6) full scale geometry files of the Oscillating Water Column, developed by the Reference Model Project (RMP). These full scale geometry files are saved as SolidWorks assembly, IGS, and STEP files, and require a CAD program to view. This data was generated upon completion of the project on September 30, 2014. The Reference Model Project (RMP), sponsored by the U.S. Department of Energy (DOE), was a partnered effort to develop open-source MHK point designs as reference models (RMs) to benchmark MHK technology performance and costs, and an open-source methodology for design and analysis of MHK technologies, including models for estimating their capital costs, operational costs, and levelized costs of energy. The point designs also served as open-source test articles for university researchers and commercial technology developers. The RMP project team, led by Sandia National Laboratories (SNL), included a partnership between DOE, three national laboratories, including the National Renewable Energy Laboratory (NREL), Pacific Northwest National Laboratory (PNNL), and Oak Ridge National Laboratory (ORNL), the Applied Research Laboratory of Penn State University, and Re Vision Consulting. Reference Model 6 (RM6) is a Backward Bent Duct Buoy (BBDB), which is a type of oscillating water column wave energy converter. First proposed by Masuda, the BBDB design is a floating Oscillating Water Column (OWC) device that consists of an air chamber, an L-shaped duct, bow and stern buoyancy modules, and a power take-off (PTO) composed of a Wells air turbine and a generator. This L- shaped device opens to the ocean downstream from the wave propagation direction. Power is produced by the motion of the wave, which causes the ambient pressure in the air chamber to vary thereby forcing air to flow through the Wells turbine. The reference wave energy resource for RM6 was developed from site information collected near Eureka, in Humboldt County, California.

16 TIDAL AND WAVE POWER↗

Cr-doped U 3 Si 2 composite fuels under steam corrosion

Dense Cr-doped U 3 Si 2 composite fuels were manufactured by spark plasma sintering, and the effects of Cr addition on mechanical properties and oxidation resistance were investigated. Furthermore, dynamic oxidation testing by thermogravimetric analysis revealed significantly improved oxidation resistance of U 3 Si 2 with minimal doping of 3 wt% Cr. The onset oxidation temperature increased to above 550 °C in air and ~520 °C in steam conditions for the 5 wt% and 10 wt% Cr-doped composites. Steam corrosion testing under 360 °C for 24 hours indicated well-maintained pellet integrity without pulverization for the 10 wt% Cr-doped U 3 Si 2 pellet which only showed minor surface oxidation. The first promising results open up the possibility of designing and manufacturing metal additive-doped U 3 Si 2 composite fuels with significantly-improved corrosion resistance as a potential candidate for accident tolerant fuels.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Characterization of Particle and Heat Losses from a High-Temperature Particle Receiver (2 nd Ed)

High - temperature particle receivers are being pursued to enable next - generation concentrating solar thermal power (CSP) systems that can achieve higher temperatures (> 700 C) to enable more efficient power cycles, lower overall system costs, and emerging CSP - based process - heat applications. The objective of this work was to develop characterization methods to quantify the particle and heat losses from the open aperture of the particle receiver. Novel camera - based imaging methods were developed and applied to both laboratory - scale and larger 1 MW t on - sun tests at the National Solar Thermal Test Facility in Albuquerque, New Mexico. Validation of the imaging methods was performed using gravimetric and calorimetric methods. In addition, conventional particle - sampling methods using volumetric particle - air samplers were applied to the on - sun tests to compare particle emission rates with regulatory standards for worker safety and pollution. Novel particle sampling methods using 3 - D printed tipping buckets and tethered balloons were also developed and applied to the on - sun particle - receiver tests. Finally, models were developed to simulate the impact of particle size and wind on particle emissions and concentrations as a function of location. Results showed that particle emissions and concentrations were well below regulatory standards for worker safety and pollution. In addition, estimated particle temperatures and advective heat losses from the camera - based imaging methods correlated well with measured values during the on - sun tests.

14 SOLAR ENERGY↗