Ultrastable low-noise current amplifier: A novel device for measuring small electric currents with high accuracy

An ultrastable low-noise current amplifier (ULCA) is presented. The ULCA is a non-cryogenic instrument based on specially designed operational amplifiers and resistor networks. It involves two stages, the first providing a 1000-fold current gain and the second performing a current-to-voltage conversion via an internal 1 MΩ reference resistor or, optionally, an external standard resistor. The ULCA’s transfer coefficient is highly stable versus time, temperature, and current amplitude within the full dynamic range of ±5 nA. The low noise level of 2.4 fA/√Hz helps to keep averaging times short at small input currents. A cryogenic current comparator is used to calibrate both input current gain and output transresistance, providing traceability to the quantum Hall effect. Within one week after calibration, the uncertainty contribution from short-term fluctuations and drift of the transresistance is about 0.1 parts per million (ppm). The long-term drift is typically 5 ppm/yr. A high-accuracy variant is available that shows improved stability of the input gain at the expense of a higher noise level of 7.5 fA/√Hz. The ULCA also allows the traceable generation of small electric currents or the calibration of high-ohmic resistors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Isosceles detector provides maximum resolution in expanded range

Dynamic range expansion system for radio frequency /RF/ signal detection equipment consists of RF amplifiers, RF amplitude modulated detectors, and operational amplifier. The analog output gives maximum resolution over fixed voltage range, without switching. Two minor drawbacks of this circuit are cited.

Watterson, R. F.↗

Logarithmic circuit with wide dynamic range

A circuit deriving an output voltage that is proportional to the logarithm of a dc input voltage susceptible to wide variations in amplitude includes a constant current source which forward biases a diode so that the diode operates in the exponential portion of its voltage versus current characteristic, above its saturation current. The constant current source includes first and second, cascaded feedback, dc operational amplifiers connected in negative feedback circuit. An input terminal of the first amplifier is responsive to the input voltage. A circuit shunting the first amplifier output terminal includes a resistor in series with the diode. The voltage across the resistor is sensed at the input of the second dc operational feedback amplifier. The current flowing through the resistor is proportional to the input voltage over the wide range of variations in amplitude of the input voltage.

Wiley, P. H.↗

Triple probe signal detection electronics for systems lacking a well defined ground

Triple probes have been used to measure plasma parameters of low temperature and edge plasmas, yielding simultaneous measurements of electron temperature, ion density, and floating potential. Unlike standard Langmuir and double probe techniques, there is no requirement to sweep the probe potential relative to the plasma, thus allowing fast time resolution. However, in some plasma systems 'ground' is not well defined with respect to a known ground, may vary strongly in time, or may be at an inconveniently high voltage. The resulting high plasma (or floating) potential requires common mode rejection before the signals can be digitized. A signal detection circuit constructed from inexpensive operational amplifiers and that makes use of a novel floating bias generation configuration is described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Implementation of an integrated op-amp based chaotic neuron model and observation of its chaotic dynamics

This paper presents a fully integrated circuit implementation of an operational amplifier (op-amp) based chaotic neuron model with a bipolar output function, experimental measurements, and analyses of its chaotic behavior. The proposed chaotic neuron model integrated circuit consists of several op-amps, sample and hold circuits, a nonlinear function block for chaotic signal generation, a clock generator, a nonlinear output function, etc. Based on the HSPICE (circuit program) simulation results, approximated empirical equations for analyses were formulated. Then, the chaotic dynamical responses such as bifurcation diagrams, time series, and Lyapunov exponent were calculated using these empirical equations. In addition, we performed simulations about two chaotic neuron systems with four synapses to confirm neural network connections and got normal behavior of the chaotic neuron such as internal state bifurcation diagram according to the synaptic weight variation. The proposed circuit was fabricated using a 0.8-{mu}m single poly complementary metal-oxide semiconductor technology. Measurements of the fabricated single chaotic neuron with {+-}2.5 V power supplies and a 10 kHz sampling clock frequency were carried out and compared with the simulated results.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of a Venus Surface Wind Sensor Based on a Miniature Drag-Force Anemometer

To better understand the atmospheric structure and dynamics on the Venus surface and provide input to climate models, there is a need to measure the wind velocity and direction on the surface and track changes over extended periods. A wind sensor based on a miniature drag-force anemometer is being developed to meet the challenges for wind measurements and operational requirements on the surface of Venus. The sensor materials are chosen to enhance durability and prevent reactivity with the Venus surface atmosphere. Advantages of this approach include that it is independent on variable heat transfer, has been matured in other harsh environment applications,and has a low mass and power requirement. This report describes demonstration of this miniature drag-force anemometer integrated with high temperature electronics in simulated Venus surface environment. Prototype drag-force anemometers were demonstrated integrated with an operational amplifier recording transient effects in a simulated Venus surface environment. For multidirectional wind monitoring, the sensors are small enough to be deployed orthogonally as a three-dimensional array on a small arm or mast

wind measurement↗

Development of a Venus Surface Wind Sensor

To better understand the atmospheric structure and dynamics on the Venus surface and provide input to climate models, there is a need to measure the wind velocity and direction on the surface and track changes over extended periods. A wind sensor based on a miniature drag-force anemometer is being developed to meet the challenges for wind measurements and operational requirements on the surface of Venus. The sensor materials are chosen to enhance durability and prevent reactivity with the Venus surface atmosphere. Advantages of this approach include that it is independent of variable heat transfer, has been matured in other harsh environment applications, and has a low mass and power requirement. Prototype drag-force anemometers were demonstrated, integrated with a high-temperature operational amplifier, recording transient effects in a simulated Venus surface environment. For multidirectional wind monitoring, the sensors are small enough to be deployed orthogonally as a three-dimensional array on a small arm or mast. This presentation describes the development and demonstration of this miniature drag-force anemometer integrated with high temperature electronics in a simulated Venus surface environment.

wind measurement↗

Nd.sup.3+fiber laser and amplifier

An Nd.sup.3+ optical fiber laser and amplifier operating in the wavelength range from 1300 to 1450 nm is described. The fiber includes a rare earth doped optical amplifier or laser operating within this wavelength band is based upon an optical fiber that guides light in this wavelength band. The waveguide structure attenuates light in the wavelength range from 850 nm to 950 nm and from 1050 nm to 1150 nm.

Dawson, Jay W.↗

Design and validation of a high-voltage levitation circuit for electrostatic accelerometers

A simple high-voltage circuit with a voltage range of 0 to 900 V and an open-loop bandwidth of 11 kHz is realized by using an operational amplifier and a MOSFET combination. The circuit is used for the levitation of a test mass of 71 g, suspended below the top-electrodes with a gap distance of 57 μm, so that the performance of an electrostatic accelerometer can be tested on the ground. The translation noise of the accelerometer, limited by seismic noise, is about 4 × 10{sup −8} m/s{sup 2}/Hz{sup 1/2} at 0.1 Hz, while the high-voltage coupling noise is one-order of magnitude lower.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a HgCdTe photomixer and impedance matched GaAs FET amplifier

A research program for the development of a 10.6 micron HgCdTe photodiode/GaAs field effect transistor amplifier package for use at cryogenic temperatures (77k). The photodiode/amplifier module achieved a noise equivalent power per unit bandwidth of 5.7 times 10 to the 20th power W/Hz at 2.0 GHz. The heterodyne sensitivity of the HgCdTe photodiode was improved by designing and building a low noise GaAs field effect transistor amplifier operating at 77K. The Johnson noise of the amplifier was reduced at 77K, and thus resulted in an increased photodiode heterodyne sensitivity.

Shanley, J. F.↗

Deflection amplifier for image dissectors

Balanced symmetrical y-axis amplifier uses zener-diode level shifting to interface operational amplifiers to high voltage bipolar output stages. Nominal voltage transfer characteristic is 40 differential output volts per input volt; bandwidth, between -3-dB points, is approximately 8 kHz; loop gain is nominally 89 dB with closed loop gain of 26 dB.

Salomon, P. M.↗

Precision calibration and reference voltage source for data acquisition systems

Hybrid integrated circuit operational amplifiers, which have inherent characteristics of low quiescent power dissipation and extended operational lifetime with high reliability, are source for digital systems. Amplifiers are coupled to Zener reference diode in current control and buffer configuration.

Source record↗

Integrated circuit physically unclonable function

An integrated circuit (IC) based physically unclonable function (PUF) that comprises a common source amplifier for generating PUF output voltages, a unity gain, negative feedback operational amplifier for generating bias voltages, a voltage regulator and a bit exclusion circuit that excludes unstable PUF bits. Compensation circuitry built into the IC-PUF provides a high power supply rejection ratio and enables highly reliable operation of the IC-PUF across varying input voltages and operating temperatures. The IC-PUF generates a uniformly random output bit stream by taking advantage of process variations that are inherent to the fabrication of (metal-oxide semiconductor) MOS transistors.

42 ENGINEERING↗

Amplifier improvement circuit

Stable input stage was designed for the use with a integrated circuit operational amplifier to provide improved performance as an instrumentation-type amplifier. The circuit provides high input impedance, stable gain, good common mode rejection, very low drift, and low output impedance.

Sturman, J.↗

Static DC to DC Power Conditioning-Active Ripple Filter, 1 MHZ DC to DC Conversion, and Nonlinear Analysis

Dc to dc static power conditioning systems on unmanned spacecraft have as their inputs highly fluctuating dc voltages which they condition to regulated dc voltages. These input voltages may be less than or greater than the desired regulated voltages. The design of two circuits which address specific problems in the design of these power conditioning systems and a nonlinear analysis of one of the circuits are discussed. The first circuit design is for a nondissipative active ripple filter which uses an operational amplifier to amplify and cancel the sensed ripple voltage. A dc to dc converter operating at a switching frequency of 1 MHz is the second circuit discussed. A nonlinear analysis of the type of dc to dc converter utilized in designing the 1 MHz converter is included.

Sander, W. A., III↗

Diode amplifier of modulated optical beam power

Analytical relations are obtained between characteristics of modulated light at the output and input of an optical diode power amplifier operating in the highly saturated gain regime. It is shown that a diode amplifier may act as an amplitude-to-phase modulation converter with a rather large bandwidth (∼10 GHz). The low sensitivity of the output power of the amplifier to the input beam power and its high energy efficiency allow it to be used as a building block of a high-power multielement laser system with coherent summation of a large number of optical beams. (lasers)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗