Search NASA⌕ Search

SEARCH · Search NASA

Results for “Optical coupling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Intensified-CCD focal plane detector for space applications A second generation

An intensified-CCD detector system developed for space applications from commercially available components is described. This detector uses components which are readily available and are mechanically, thermally, and optically coupled to produce the final compact system. The CCD is cooled using a Peltier-effect thermoelectric cooler to reduce thermal noise. The image is formed on the photocathode of a proximity-focused image intensifier and is transferred fiber-optically from the intensifier to the CDD. Various photocathode and window materials are used to optimize the system for use within the wavelength range extending from the far UV to the near IR. The basic design, including the image intensifier, intensifier-CCD interface, CCD array, cooling, electronics, and mounting, and the detector performance are described in detail.

Torr, M. R.↗

Delaying Trains of Short Light Pulses in WGM Resonators

Suitably configured whispering-gallery-mode (WGM) optical resonators have been proposed as delay lines for trains of short light pulses. Until now, it has been common practice to implement an optical delay line as a coiled long optical fiber, which is bulky and tends to be noisy. An alternative has been to implement an optical delay line as a coupled-resonator optical waveguide (a chain of coupled optical resonators), which is compact but limits the width of the pulse spectrum to the width of an optical resonance and thereby places a lower limit on the duration of a pulse. In contrast, a delay line according to the proposal could be implemented as a single WGM resonator, and the pulses delayed by the resonator could be so short that their spectral widths could greatly exceed the spectral width of any single resonance. The proposal emerged from theoretical and experimental studies of the propagation of a pulse train in a WGM resonator. An important element of the theoretical study was recognition that the traditional definition of group velocity in effect, the velocity of a single pulse comprising a packet of waves propagating in a medium, the responsivity of which is a monotonous function of frequency does not necessarily apply in the case of a WGM resonator or other medium having a spectrum consisting of discrete resonance peaks at different frequencies. A new definition of group velocity, applicable to a train of pulses propagating in such a medium, was introduced and found to lead to the discovery of previously unknown features of propagation. Notably, it was found that in a micro - sphere optical resonator that supports a suitable combination of WGM modes, the group velocity for a train of light pulses could be positive, zero, or negative. A positive group velocity could be so small that the delay could be much longer than the ring-down time of the resonator; a delay of such great length is impossible for a single pulse interacting with either a linearly responding lossless resonator or a coupled- resonator optical waveguide.

Matsko, Andrey↗

Overview of the Design, Fabrication and Performance Requirements of Micro-Spec, an Integrated Submillimeter Spectrometer

Micro-Spec is a compact submillimeter (350-700 GHz) spectrometer which uses low loss superconducting niobium microstrip transmission lines and a single-crystal silicon dielectric to integrate all of the components of a grating-analog spectrometer onto a single chip. Here we present details of the fabrication and design of a prototype Micro-Spec spectrometer with resolution, R64, where we use a high-yield single-flip wafer bonding process to realize instrument components on a 0.45 m single-crystal silicon dielectric. We discuss some of the electromagnetic design concerns (such as loss, stray-light, cross-talk, and fabrication tolerances) for each of the spectrometer components and their integration into the instrument as a whole. These components include a slot antenna with a silicon lens for optical coupling, a phase delay transmission line network, parallel plate waveguide interference region, and aluminum microstrip transmission line kinetic inductance detectors with extremely low cross-talk and immunity to stray light. We have demonstrated this prototype spectrometer with design resolution of R64. Given the optical performance of this prototype, we will also discuss the extension of this design to higher resolutions suitable for balloon-flight.

spectrometer↗

Automatic quadrature control and measuring system

A quadrature component cancellation and measuring system comprising a detection system for detecting the quadrature component from a primary signal, including reference circuitry to define the phase of the quadrature component for detection is described. A Raysistor optical coupling control device connects an output from the detection system to a circuit driven by a signal based upon the primary signal. Combining circuitry connects the primary signal and the circuit controlled by the Raysistor device to subtract quadrature components. A known current through the optically sensitive element produces a signal defining the magnitude of the quadrature component.

Hamlet, J. F.↗

Fiber-Optic/Photoelastic Flow Sensors

Simple, rugged, lightweight transducers detect periodic vortices. Fiber-optic-coupled transducers developed to measure flows over wide dynamic ranges and over wide temperature ranges in severe environments. Used to measure flows of fuel in advanced aircraft engines. Feasibility of sensors demonstrated in tests of prototype sensor in water flowing at various temperatures and speeds. Particularly attractive for aircraft applications because optical fibers compact and make possible transmission of sensor signals at high rates with immunity from electromagnetic interference at suboptical frequencies. Sensors utilize optical-to-optical conversion via photoelastic effect.

Wesson, Laurence N.↗

Perfluorobutyl iodides as gain media for a solar-pumped iodine laser amplifier

The effectiveness of t-C4F9I and n-C4F9I as gain media for a space-based solar-pumped iodine photodissociation laser is investigated experimentally. The optically coupled flashlamp/amplifier-tube apparatus described by Hwang et al. (1986) is employed, driving the amplifier with 4-microsec 4.2-mJ TEM(00) pulses from a flashlamp-pumped laser oscillator; the variation of amplification with energy-extraction time was monitored by inserting a delay of up to 1 msec between the firing of the two flashlamps and measuring the delay between the optical pulses. The results are presented graphically and briefly characterized. The performance of t-C4F9I is found to be better than that of n-C4F9I (or n-C3F7I), with an absorption band shifted toward the visible (for improved utilization of solar radiation), higher gain (by a factor of 2) at all delay times, and better chemical reversibility. The gain did not depend significantly on temperature in any of the iodides.

Tabibi, Bagher M.↗

Towards an Imaging Mid-Infrared Heterodyne Spectrometer

We are developing a concept for a compact, low-mass, low-power, mid-infrared (MIR; 5- 12 microns) imaging heterodyne spectrometer that incorporates fiber optic coupling, Quantum Cascade Laser (QCL) local oscillator, photomixer array, and Radio Frequency Software Defined Readout (RFSDR) for spectral analysis. Planetary Decadal Surveys have highlighted the need for miniaturized, robust, low-mass, and minimal power remote sensing technologies for flight missions. The drive for miniaturization of remote sensing spectroscopy and radiometry techniques has been a continuing process. The advent of MIR fibers, and MEMS techniques for producing waveguides has proven to be an important recent advancement for miniaturization of infrared spectrometers. In conjunction with well-established photonics techniques, the miniaturization of spectrometers is transitioning from classic free space optical systems to waveguide/fiber-based structures for light transport and producing interference effects. By their very nature, these new devices are compact and lightweight. Mercury-Cadmium-Telluride (MCT) and Quantum Well Infrared Photodiodes (QWIP) arrays for heterodyne applications are also being developed. Bulky electronics is another barrier that precluded the extension of heterodyne systems into imaging applications, and our RFSDR will address this aspect.

Hewagama, T.↗

Design and Performance of a Spectrometer for Deployment on MISSE 7

A spectrometer for reflectance and transmission measurements of samples exposed to the space environment has been developed for deployment on the Materials on the International Space Station Experiment (MISSE) 7. The instrument incorporates a miniature commercial fiber optic coupled spectrometer with a computer control system for detector operation, sample motion and illumination. A set of three spectrometers were recently integrated on the MISSE7 platform with launch and deployment on the International Space Station scheduled for summer of this year. The instrument is one of many active experiments on the platform. The performance of the instrument prior to launch will be discussed. Data from samples measured in the laboratory will be compared to those from the instrument prior to launch. These comparisons will illustrate the capabilities of the current design. The space environment challenges many materials. When in operation on the MISSE 7 platform, the new spectrometer will provide real time data on the how the space environment affects the optical properties of thermal control paints and optical coatings. Data obtained from comparison of pre and post flight measurements on hundreds of samples exposed on previous MISSE platforms have been reported at these meetings. With the new spectrometer and the ability to correlate measured changes with time on orbit and the occurrence of both natural events and human activities, a better understanding of the processes responsible for degradation of materials in space will be possible.

Pippin, Gary↗

Laser Ignition Technology for Bi-Propellant Rocket Engine Applications

The fiber optically coupled laser ignition approach summarized is under consideration for use in igniting bi-propellant rocket thrust chambers. This laser ignition approach is based on a novel dual pulse format capable of effectively increasing laser generated plasma life times up to 1000 % over conventional laser ignition methods. In the dual-pulse format tinder consideration here an initial laser pulse is used to generate a small plasma kernel. A second laser pulse that effectively irradiates the plasma kernel follows this pulse. Energy transfer into the kernel is much more efficient because of its absorption characteristics thereby allowing the kernel to develop into a much more effective ignition source for subsequent combustion processes. In this research effort both single and dual-pulse formats were evaluated in a small testbed rocket thrust chamber. The rocket chamber was designed to evaluate several bipropellant combinations. Optical access to the chamber was provided through small sapphire windows. Test results from gaseous oxygen (GOx) and RP-1 propellants are presented here. Several variables were evaluated during the test program, including spark location, pulse timing, and relative pulse energy. These variables were evaluated in an effort to identify the conditions in which laser ignition of bi-propellants is feasible. Preliminary results and analysis indicate that this laser ignition approach may provide superior ignition performance relative to squib and torch igniters, while simultaneously eliminating some of the logistical issues associated with these systems. Further research focused on enhancing the system robustness, multiplexing, and window durability/cleaning and fiber optic enhancements is in progress.

Thomas, Matthew E.↗

Neutron-image intensifier

Electronic intensifier tube with a demagnification ratio of 9-1 enhances the usefulness of neutron-radiographic techniques. A television signal can be obtained by optical coupling of a small-output phosphor-light image to a television camera.

Berger, H.↗

CRT image recording evaluation

Performance capabilities and limitations of a fiber optic coupled line scan CRT image recording system were investigated. The test program evaluated the following components: (1). P31 phosphor CRT with EMA faceplate; (2). P31 phosphor CRT with clear clad faceplate; (3). Type 7743 semi-gloss dry process positive print paper; (4). Type 777 flat finish dry process positive print paper; (5). Type 7842 dry process positive film; and (6). Type 1971 semi-gloss wet process positive print paper. Detailed test procedures used in each test are provided along with a description of each test, the test data, and an analysis of the results.

Source record↗

A CCD image transducer and processor suitable for space flight

A satellite borne extreme ultraviolet solar telescope makes use of CCD area arrays for both image readout and onboard data processing. The instrument is designed to view the inner solar corona in the wavelength band 170 - 630 A, and the output video stream may be selected by ground command to present the coronal scene, or the time-rate-of-change of the scene. Details of the CCD application to onboard image processing are described, and a discussion of the processor's potential for telemetry bandwidth compression is included. Optical coupling methods, data storage requirements, spatial and temporal resolution, and nonsymmetry of resolution (pitch) in the CCD are discussed.

Michels, D. J.↗

Calibration of large area scintillation counters on cosmic rays

Construction and calibration are reported for a 6-sq m scintillation counter consisting of two pieces of clear Lucite optically joined along a common edge, sixteen squares of plastic scintillator optically coupled on top of the Lucite, and eight photomultiplier tubes for light collection. Calibration of this counter using an anticoincidence counter to exclude multiple particle events is described. Theoretical calculations for purely electromagnetic extensive air showers indicate that this counter should detect an average of 2.5 particles per event, while the calibration data yield about 1.8 particles per event. It is shown that the anticoincidence-counter calibration method must be used for counters with areas of more than a few square meters if calibration on the response from a single particle of an extensive air shower is desired.

Saterlie, S. F.↗

Evaluation of a large format image tube camera for the shuttle sortie mission

A large format image tube camera of a type under consideration for use on the Space Shuttle Sortie Missions is evaluated. The evaluation covers the following subjects: (1) resolving power of the system (2) geometrical characteristics of the system (distortion etc.) (3) shear characteristics of the fiber optic coupling (4) background effects in the tube (5) uniformity of response of the tube (as a function of wavelength) (6) detective quantum efficiency of the system (7) astronomical applications of the system. It must be noted that many of these characteristics are quantitatively unique to the particular tube under discussion and serve primarily to suggest what is possible with this type of tube.

Tifft, W. C.↗

Photoelectron counting with an image intensifier tube and a self-scanned photodiode array

A self-scanned photodiode array was fiber-optically coupled to an ITT proximity-focused image intensifier tube. It was determined that a single photoelectron event produces 34,000 charge carriers in a photodiode. This charge is only a factor of 2.8 above the rms noise level of the preamplifier used in the tests, but standard charge-sensitive techniques are at least a factor of 12 better. The image tube and photodiode array combination can be packaged in a disk 5.1 cm in diameter and 2.6 cm thick.

Sandel, B. R.↗

Slow scan SEC vidicon system

A slow scan SEC vidicon system is described here. This system is coupled to the 152.4-cm (60-in) McMath telescope at Kitt Peak National Observatory. An anamorphic lens system is used to couple optically the vertical spectrograph to the vidicon system. The resolutin of the over-all system is 55 mA, while the resolution of the spectrograph alone is 50 mA. Actual observational results are used to evaluate the system performance.

Chiu, H.-Y.↗

A photon-counting multichannel spectrometer

A multichannel detector system is described in which the positions of individual photon events in a high-gain image intensifier are decoded in the output of a video detector. The high-gain intensifier consists of a pair of three-stage electrostatic image-tube assemblies each containing three fiber-optically-coupled tubes potted in a rugged package with an internal high-voltage supply. Operation of the electrooptical system is discussed along with the pulse-detection process and the operation of the spectrograph in which the image-tube assembly is mounted. It is noted that the spectrometer detects 1.0 count/sec per A for an object of magnitude 13.0 at the peak of its response in the visual band when no light is lost on the slit, that a 10% coincidence correction is reached at an overall count rate of 860 per sec, and that the response follows an exponential law up to count rates of about 4000 per sec. The measured spectrum of the Seyfert galaxy NGC 5548 is provided as an example of the raw data produced by the instrument on a 1.5 meter telescope.

Shectman, S. A.↗

A high-voltage-isolated automated data acquisition system

A data acquisition system for electric-arc heated, high-temperature wind tunnel facilities has been developed; the high voltage isolation of the system exceeds 50 kV. A closed loop, optically coupled data system acquires transducer signals from high-temperature, arc-generated plasmas used for reentry testing. The data acquisition system monitors on-line tests, stores data on magnetic tape, and prints out a paper tape. The system has 400 data channels: 200 low-voltage programmable channels and 200 high-voltage sequential channels.

Cox, J.↗