Search NASA⌕ Search

SEARCH · Search NASA

Results for “Optical detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Nanoscale Observation and Control of Quasiparticle Induced Magnetic Noise in a Superconducting Resonator

Superconducting circuits are arguably taking a leading role in driving the ongoing quantum technological revolution. A detailed knowledge of the microscopic fluctuating electromagnetic properties plays an important role in advancing the circuitry design, testing, and material integration of cutting-edge superconducting quantum electronics. Here, in this work, we report scanning nitrogen-vacancy (NV) quantum sensing of local magnetic noise environment of an on-chip superconducting resonator. We find that quasiparticle-induced fluctuating magnetic fields can drive NV spin relaxation, which shows a peak value around the superconducting transition point of niobium at the thermal equilibrium state. External microwave driving at the resonator mode frequency significantly increases the quasiparticle density, leading to enhancement of magnetic noise. We further perform optically detected magnetic resonance measurements to demonstrate quasiparticle magnetic noise mediated off-resonant dipole coupling between the NV center and niobium resonator. Our Letter reports experimental observation of the Hebel-Slichter peak signature by an external sensor outside of a superconductor. The presented study also highlights the advantages of quantum sensors in investigating miniaturized superconducting devices, providing insights into their future performance improvements.

Li, Senlei [Georgia Institute of Technology]↗

Local Ferromagnetic Resonance Measurements of Mesoscopically Patterned Ferromagnets Using Deterministically Placed Nanodiamonds

Nitrogen-vacancy centers in diamond have recently been established as effective sensors of the magnetization dynamics in vicinal ferromagnetic materials. Here, we demonstrate sub-100-nm placement accuracy of nitrogen-vacancy-containing nanodiamonds and use these as local sensors that probe optically detected ferromagnetic resonance in mesoscopically patterned Permalloy islands. These measurements reveal variations in the ferromagnetic resonance signal at different sites on these structures with distinct behavior in the edge and the bulk of patterned features. These test measurements establish an easily implemented approach for spatially targeted measurements of spin dynamics in mesoscale ferromagnets. In principle, the methodology can also be extended to local studies of nanoscale ferromagnets, such as single magnetic nanowires and nanoparticles.

30 DIRECT ENERGY CONVERSION↗

Neutral Silicon-Vacancy Centers in Diamond via Photoactivated Itinerant Carriers

Neutral silicon-vacancy (Si-V 0 ) centers in diamond are promising candidates for quantum network applications because of their exceptional optical properties and spin coherence. However, the stabilization of Si-V 0 centers requires careful Fermi-level engineering of the diamond host material, making further technological development challenging. Here, we show that Si-V 0 centers can be efficiently stabilized by photoactivated itinerant carriers. Even in this nonequilibrium configuration, the resulting Si-V 0 centers are stable enough to allow for resonant optical excitation and optically detected magnetic resonance. Furthermore, our results pave the way for on-demand generation of Si-V 0 centers as well as other emerging quantum defects in diamond.

74 ATOMIC AND MOLECULAR PHYSICS↗

Photoluminescence, photophysics, and photochemistry of the V B - defect in hexagonal boron nitride

Extensive photochemical and spectroscopic properties of the V B - defect in hexagonal boron nitride are calculated, concluding that the observed photoemission associated with recently observed optically detected magnetic resonance is most likely of (1) 3 E'' → (1) 3 A' 2 origin. Rapid intersystem crossing from the defect's triplet to singlet manifolds explains the observed short excited-state lifetime and very low quantum yield. New experimental results reveal smaller intrinsic spectral bandwidths than previously recognized, interpreted in terms of spectral narrowing and zero-phonon-line shifting induced by the Jahn-Teller effect. Different types of computational methods are applied to map out the complex triplet and singlet defect manifolds, including the doubly ionized formulation of the equation-of-motion coupled-cluster theory that is designed to deal with the open-shell nature of defect states, and mixed quantum-mechanics/molecular-mechanics schemes enabling 5763-atom simulations. Finally, two other energetically feasible spectral assignments from among the singlet and triplet manifolds are considered, but ruled out based on inappropriate photochemical properties.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Spectroscopy of Rydberg states in erbium using electromagnetically induced transparency

We present a study of the Rydberg spectrum in 166 Er for series connected to the 4 f 12 ( 3 H 6 )6s, J c = 13/2 and J c = 11/2 ionic core states using an all-optical detection based on electromagnetically induced transparency in an effusive atomic beam. Identifying approximately 550 individual states, we find good agreement with a multi-channel quantum defect theory (MQDT) which allows assignment of most states to ns or nd Rydberg series. We provide an improved accuracy for the lowest two ionization thresholds to E IP, J c =13/2 = 49260:750(1) cm -1 and E IP, J c =11/2 = 49701:184(1) cm -1 as well as the corresponding quantum defects for all observed series. We identify Rydberg states in five different isotopes, and states between the two lowest ionization thresholds. Our results open the way for future applications of Rydberg states for quantum simulation using erbium and exploiting its special open-shell structure.

74 ATOMIC AND MOLECULAR PHYSICS↗

High accuracy single-layer free-space diffractive neuromorphic classifiers for spatially incoherent light

Free-space all-optical diffractive systems have shown promise for neuromorphic classification of objects without converting light to the electronic domain. While the factors that govern these systems have been studied for coherent light, the fundamental properties for incoherent light have not been addressed, despite the importance for many applications. Here we use a co-design approach to show that optimized systems for spatially incoherent light can achieve performance on par with the best linear electronic classifiers even with a single layer containing few diffractive features. This performance is limited by the inherent linear nature of incoherent optical detection. We circumvent this limit by using a differential detection scheme that achieves greater than 94% classification accuracy on the MNIST dataset and greater than 85% classification accuracy for Fashion-MNIST, using a single layer metamaterial.

Léonard, François (ORCID:0000000249736743)↗

Adaptive bandwidth management for entanglement distribution in quantum networks

Flexible grid wavelength division multiplexing is a powerful tool in lightwave communications to maximize spectral efficiency. In the emerging field of quantum networking, the need for effective resource provisioning is particularly acute, given the generally lower power levels, higher sensitivity to loss, and inapplicability of optical detection and retransmission. In this letter, we leverage flex grid technology to demonstrate reconfigurable distribution of quantum entanglement in a four-user tabletop network. By adaptively partitioning bandwidth with a single wavelength-selective switch, we successfully equalize two-party coincidence rates that initially differ by over two orders of magnitude. Our scalable approach introduces loss that is fixed with the number of users, offering a practical path for the establishment and management of quality-of-service guarantees in large quantum networks.

42 ENGINEERING↗

Using Raman scattering to study reacting gas flow over a catalyst

l present a series of computational methods for analyzing and correcting Raman scattering from a reacting gas flow. My work focused on the laser diagnostic measurements of formaldehyde production over a silver catalyst, specifically the Raman spectroscopy component. This technique offers a non-intrusive, in situ way to measure the coupling between the gas phase and surface activity of a catalytic reaction at relevant industrial conditions. This report outlines the steps followed for correcting the non-idealities in the data due to both the detection optics and scattering mechanics. By implementing such refinement steps, l can generate an accurate 2D spatial map of the temperature profile, number densities for major species, and relative consumption of reactants throughout the reactor cell.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Drone Video Platform—Collision Avoidance, Situational Awareness, and Communications

Small unmanned aerial systems are ideal for delivering sensors into areas that are inaccessible or too dangerous for human entry or manned aircraft over-flights. The systems can fly low and slow for enhanced sensitivity and in tight spaces where ordinary aircraft could never fit. We have configured and flown sensor payloads for radiation, chemical, and optical detection on small fixed-wing and rotary-wing aircraft. All the sensor packages provide telemetry, GPS coordinates, LIDAR distance ranging, and absolute time of day to microsecond accuracy. Payload weights range from less than 1 kg up to 5.5 kg. Currently, communications are over 2.4 GHz and 915 MHz radios, as well as over 4G LTE cellular data links. Real-time data feeds from the sensor payloads to web browser clients anywhere in the world are possible via a virtual EC2 server on the Amazon AWS cloud. In FY 2019, the Nevada National Security Site teamed with Virginia Tech, H3D Corp., and Unmanned Systems, Inc. to accomplish the four flight missions described in this report. A large part of this year’s mission goals were to demonstrate the ability to fly beyond visual line of sight (BVLOS).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Functionalization of nitrogen vacancy-containing nanodiamonds with a metal-organic framework for quantum sensing applications

Nitrogen vacancy (NV)-containing nanodiamonds (NDs) are an important material in applications such as biological imaging, catalysis, and, in particular, quantum sensing. Careful manipulation of the surface coating on NV NDs is essential for both enhancing quantum sensor performance and for tuning selectivity towards specific sensing targets. Here, we demonstrate a simple synthetic approach for functionalizing NV NDs with the zeolitic imidazole framework-8 (ZIF-8) metal–organic framework (MOF), providing a well-ordered, porous scaffold for immobilizing target analytes near the NV ND surface. The composites were structurally characterized by x-ray diffraction, electron microscopy, and X-ray photoelectron spectroscopy, and these results were all consistent with NV NDs fully encapsulated by ZIF-8. Critically, the luminescent properties of the NV NDs, which are vital for quantum sensing experiments such as optically detected magnetic resonance (ODMR), are unchanged by the MOF coating. Moreover, spin relaxometry experiments indicate that the ZIF-8 coating significantly enhances the NV ND spin longitudinal relaxation time T1, a critical quantum parameter for sensing applications. Given the tremendous structural diversity of MOFs, the NV ND@MOF composites are an exciting material class with exciting implications for the development of high-performance quantum sensors.

Crawford, Scott↗

Nitrogen Vacancy Center in Diamond for the Stress and Field Sensing Applications

The nitrogen-vacancy (NV) center in a nanodiamond (ND) crystal is a promising material for quantum information processing, sensing, and computing applications. It is one of the best candidate materials for quantum sensing and metrology expected to work at elevated temperatures and pressures conditions. We computationally show the effect of strain on the defect band edges and band gaps in the NV center diamond. A low energy Hamiltonian is developed for the ±1 spin manifold at the ground state. We show the quantum sensing device is a few orders of magnitude superior in sensing than the traditional optical sensing devices. We also discuss experimental results from the optically detected magnetic resonance (ODMR) and the spin relaxometry for the field sensing applications. The presentation concludes by providing a model for free spins detection of the rare earth ions.

field sensing applications↗

Synthesis of nanodiamonds encapsulated by zeolitic imidazole framework-8 for quantum sensing applications

Nitrogen vacancy (NV)-containing nanodiamonds are widely used in quantum sensing applications due to their high sensitivity to magnetic fields, relatively low cost, and ability to be initialized, manipulated, and read out at room temperature. Quantum sensing techniques such as optically detected magnetic resonance (ODMR) and spin relaxometry have exploited the sensitivity of the NV nanodiamonds to magnetic fields to detect a range of analytes, such as pH, metal ions, and biomolecules. However, diversifying the sensing targets accessible by NV diamond quantum sensors typically requires careful engineering of the diamond surface chemistry with stimuli-responsive functional groups. Here, a simple protocol for coating NV nanodiamonds with the zeolitic imidazole framework 8 (ZIF-8), a widely used metal-organic framework, is presented. ZIF-8 is a highly porous material that has been used as a selective sensor for gasses, metal ions, and other analytes. The material is well-characterized by x-ray diffraction, transmission electron microscopy, scanning electron microscopy, x-ray photoelectron spectroscopy, and luminescence spectroscopy. Encapsulation of NV nanodiamonds with a porous scaffold such as ZIF-8 provides a promising method for improving the selectivity for the quantum sensing of various analytes. Importantly, the ZIF-8 coating does not impact the luminescence properties of the NV diamond, which is a key readout in ODMR and spin relaxometry sensing approaches. Indeed, the ODMR spectra with and without the ZIF-8 shell is nearly identical. Moreover, the ZIF-8 coating increases the longitudinal spin relaxation time of the NV nanodiamond by a factor of 4 relative to aggregated diamond, a desirable outcome for spin relaxation-based quantum sensing. Metal-organic framework composites with nanodiamonds thus are an exciting strategy for enhancing NV nanodiamond performance in applications such as quantum sensing and quantum-enhanced nuclear magnetic resonance spectroscopy.

nitrogen vacancy nanodiamond↗

Portable Waveguide-Based Optical Biosensor

Rapid, on-site diagnostics allow for timely intervention and response for warfighter support, environmental monitoring, and global health needs. Portable optical biosensors are being widely pursued as a means of achieving fieldable biosensing due to the potential speed and accuracy of optical detection. We recently developed the portable engineered analytic sensor with automated sampling (PEGASUS) with the goal of developing a fieldable, generalizable biosensing platform. Here, we detail the development of PEGASUS’s sensing hardware and use a test-bed system of identical sensing hardware and software to demonstrate detection of a fluorescent conjugate at 1 nM through biotin-streptavidin chemistry.

47 OTHER INSTRUMENTATION↗

Assessment of Hydroxyl Radical Reactivity in Sulfur-Containing Amino Acid Models Under Acidic pH

Methionine residues in proteins and peptides are frequently oxidized by losing one electron. The presence of nearby amide groups is crucial for this process, enabling methionine to participate in long-range electron transfer. Hydroxyl radical (HO•) plays an important role being generated in aerobic organisms by cellular metabolisms as well as by exogenous sources such as ionizing radiations. The reaction of HO• with methionine mainly affords the one-electron oxidation of the thioether moiety through two consecutive steps (HO• addition to the sulfur followed by HO− elimination). We recently investigated the reaction of HO• with model peptides mimicking methionine and its cysteine-methylated counterpart, i.e., CH3C(O)NHCHXC(O)NHCH3, where X = CH2CH2SCH3 or CH2SCH3 at pH 7. The reaction mechanism varied depending on the distance between the sulfur atom and the peptide backbone, but, for a better understanding of various suggested equilibria, the analysis of the flux of protons is required. We extended the previous study to the present work at pH 4 using pulse radiolysis techniques with conductivity and optical detection of transient species, as well as analysis of final products by LC-MS and high-resolution MS/MS following γ-radiolysis. Comparing all the data provided a better understanding of how the presence of nearby amide groups influences the one-electron oxidation mechanism.

Biochemistry & Molecular Biology↗

SDSS J1058+5443: A Blue Quasar without Optical/NUV Broad Emission Lines

In this paper, the blue quasar SDSS J105816.19+544310.2 (=SDSS J1058+5443) at redshift 0.479 has been reported as the best true type 2 quasar candidate with the disappearance of central broad-line regions. There are no definite conclusions on the very existence of true type 2 active galactic nuclei (AGN), mainly due to detected optical broad emission lines in high-quality spectra of some previously classified true type 2 AGN candidates. Here, unlike previously reported true type 2 AGN candidates among narrow emission-line galaxies with weak AGN activities but strong stellar lights, the definitely blue quasar SDSS J1058+5443 can be well confirmed as a true type 2 quasar due to apparent quasar-shape blue continuum emissions but an apparent loss of both the optical broad Balmer emission lines and the near-UV (NUV) broad Mg II emission line. Based on different model functions and the F-test statistical technique, after considering blueshifted optical and UV Fe II emissions, there are no apparent broad optical Balmer emission lines and/or broad NUV Mg II lines, and the confidence level is smaller than 1σ in support of broad optical and NUV emission lines. Moreover, assuming the virialization assumption to broad-line emission clouds, the reconstructed broad emission lines strongly indicate that the probable intrinsic broad emission lines, if they exist, cannot be hidden or overwhelmed in the noise of the Sloan Digital Sky Survey spectrum of SDSS J1058+5443. Therefore, SDSS J1058+5443 is so far the best and most robust true type 2 quasar candidate, leading to the clear conclusion of the very existence of true type 2 AGN.

79 ASTRONOMY AND ASTROPHYSICS↗

MOSAiC-Colorado State University Ice Spectrometer

This data set contains atmospheric ice nucleating particle (INP) measurements, using Colorado State University&rsquo;s (CSU) Ice Spectrometer (IS), of filter collections taken at the U.S. DOE ARM AMF2 site onboard the R/V Polarstern P-deck during the Multidisciplinary Drifting Observatory for the Study of Arctic Climate (MOSAiC) field campaign. Samples were collected from October 27, 2019 to September 24, 2020. A filter sampler was mounted approximately 15 m above ground level on a railing in proximity to (and approximately 3 m below) the Aerosol Observation System (AOS) inlet. Single-use filter units open to the atmosphere were pre-cleaned and pre-loaded with 47-mm diameter Nuclepore polycarbonate (0.2 &micro;m pore-diameter) filters. Filters were typically drawn for a three-day period, with an average volume of air filtered of 87,000 standard liters. Total volumes were calculated through recorded daily flow rates using a mass flow meter (TSI). After collection, filters were stored and transported frozen until analysis using CSU&rsquo;s IS instrument (McCluskey et al., 2018). Aerosol particles were first re-suspended in 8 mL of 0.1 &micro;m-filtered deionized (DI) water. Aliquots of each suspension, and corresponding 11-fold dilutions, were dispensed into polymerase chain reaction (PCR) trays and placed into the aluminum blocks of the IS. Samples were cooled at approximately 0.33 &deg;C min -1 and freezing detected optically with corresponding temperatures recorded. Cumulative INP concentrations were determined through calculating the number of INPs per mL of suspension (Vali, 1971) and converting to concentration per standard L of air by accounting for the proportion of liquid used and volume of air collected. All samples were corrected for the number of INPs on the average of four field blanks (cleaned, handled, transported, and analyzed in the same way without air flow). Two-tailed, 95% confidence intervals for binomial sampling are provided (Agresti and Coull, 1998). Select samples were also heat treated (95 &deg;C for 20 min) to denature and deactivate biological INPs present and digested in 10% H 2 O 2 at 95 &deg;C under UV-B for 20 min to remove any organic carbon INPs. Agresti, A, and BA Coull. 1998. "Approximate is better than &ldquo;exact&rdquo; for interval estimation of binomial proportions." American Statistics 52: 119&ndash;126. https://doi.org/10.2307/2685469 McCluskey, CS, J Ovadnevaite, M Rinaldi, J Atkinson, F Belosi, D Ceburnis, &hellip; and PJ DeMott. 2018. "Marine and Terrestrial Organic Ice-Nucleating Particles in Pristine Marine to Continentally Influenced Northeast Atlantic Air Masses." Journal of Geophysical Research: Atmospheres 123 (11): 6196&ndash;6212, https://doi.org/10.1029/2017JD028033 Vali, G. 1971. "Quantitative Evaluation of Experimental Results and the Heterogeneous Freezing Nucleation of Supercooled Liquids." Journal of the Atmospheric Sciences 28: 402-209. https://doi.org/10.1175/1520-0469(1971)028<0402:QEOERA>2.0.CO;2

54 ENVIRONMENTAL SCIENCES↗

Ice nucleating particle concentrations measured by the PNNL-CFDC during the AGINSGP field experiment

Real-time, immersion mode ambient ice nucleating particle (INP) concentrations were measured at ARM&rsquo;s Southern Great Plains (SGP) site during the AGINSGP field experiment using a continuous flow diffusion chamber (CFDC) from Pacific Northwest National Laboratory (PNNL). The PNNL-CFDC is an ice-thermal gradient diffusion chamber that optically detects the freezing of single aerosol particles (Kulkarni et al. 2020). The instrument was located in the guest instrument facility (GIF) and measured INP concentrations from April 8th to April 29th. Air was drawn into the GIF through custom aluminum stack inlets (6&rdquo; inner diameter) attached vertically to the outer GIF wall and the GIF outside platform. A blower pulled air through the stacks at a velocity of 1 m/s. Aerosol instruments subsampled via wall ports, through either 3/8&rdquo; or 1/4" copper lines, depending on sample flow of the instrument. Kulkarni, G., Hiranuma, N., M&ouml;hler, O., H&ouml;hler, K., China, S., Cziczo, D. J., & DeMott, P. J. (2020). A new method for operating a continuous-flow diffusion chamber to investigate immersion freezing: Assessment and performance study. Atmospheric Measurement Techniques, 13(12), 6631&ndash;6643. https://doi.org/10.5194/amt-13-6631-2020.

54 ENVIRONMENTAL SCIENCES↗

Ice nucleating particle concentrations measured by the CSU-CFDC during the AGINSGP field experiment

Real-time, immersion mode ambient ice nucleating particle (INP) concentrations were measured at ARM&rsquo;s Southern Great Plains (SGP) site during the AGINSGP field experiment using a continuous flow diffusion chamber (CFDC) from Colorado State University (CSU). The CSU-CFDC is an ice-thermal gradient diffusion chamber that optically detects the freezing of single aerosol particles (Rogers 1988; Rogers et al. 2001; and Eidhammer et al. 2010). The instrument was located in the guest instrument facility (GIF) and measured INP concentrations from April 8th to April 29th. Air was drawn into the GIF through custom aluminum stack inlets (6&rdquo; inner diameter) attached vertically to the outer GIF wall and the GIF outside platform. A blower pulled air through the stacks at a velocity of 1 m/s. Aerosol instruments subsampled via wall ports, through either 3/8&rdquo; or 1/4" copper lines, depending on sample flow of the instrument. Rogers, D. C., Development of a continuous flow thermal gradient diffusion chamber for ice nucleation studies, Atmospheric Research, 22(2), 149-181, doi:10.1016/0169-8095(88)90005-1, 1988. Rogers, D. C., P. J. DeMott, S. M. Kreidenweis and Y. Chen, A continuous flow diffusion chamber for airborne measurements of ice nuclei, J. Atmos. Oceanic Technol., 18, 725-741, doi:10.1175/1520-0426(2001)018<0725:ACFDCF>2.0.CO;2, 2001. Eidhammer, T., DeMott, P. J., Prenni, A. J., Petters, M. D., Twohy, C. H., Rogers, D. C., Stith, J., Heymsfield, A., Wang, Z., Haimov, S., French, J., Pratt, K., Prather, K., Murphy, S., Seinfeld, J., Subramanian, R., and Kreidenweis, S. M., Ice initiation by aerosol particles: Measured and predicted ice nuclei concentrations versus measured ice crystal concentrations in an orographic wave cloud, J. Atmos. Sci., 67, 2417-2436, doi:10.1175/2010JAS3266.1, 2010

54 ENVIRONMENTAL SCIENCES↗