Search NASA⌕ Search

SEARCH · Search NASA

Results for “Optical signal processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Graphical Optimization of Spectral Shift Reconstructions for Optical Backscatter Reflectometry

Optical backscatter reflectometry (OBR) is an interferometric technique that can be used to measure local changes in temperature and mechanical strain based on spectral analyses of backscattered light from a singlemode optical fiber. The technique uses Fourier analyses to resolve spectra resulting from reflections occurring over a discrete region along the fiber. These spectra are cross-correlated with reference spectra to calculate the relative spectral shifts between measurements. The maximum of the cross-correlated spectra—termed quality—is a metric that quantifies the degree of correlation between the two measurements. Recently, this quality metric was incorporated into an adaptive algorithm to (1) selectively vary the reference measurement until the quality exceeds a predefined threshold and (2) calculate incremental spectral shifts that can be summed to determine the spectral shift relative to the initial reference. Using a graphical (network) framework, this effort demonstrated the optimal reconstruction of distributed OBR measurements for all sensing locations using a maximum spanning tree (MST). By allowing the reference to vary as a function of both time and sensing location, the MST and other adaptive algorithms could resolve spectral shifts at some locations, even if others can no longer be resolved.

47 OTHER INSTRUMENTATION↗

Overview of recent turbulence studies across multiple confinement modes at the ASDEX Upgrade tokamak using the Correlation Electron Cyclotron Emission diagnostic

This work presents an overview of recent and ongoing experimental measurements of core and edge turbulence across multiple confinement regimes using the Correlation Electron Cyclotron Emission (CECE) diagnostic at the ASDEX Upgrade (AUG) tokamak. A common goal among these investigations is to identify how the properties of the turbulent electron temperature fluctuations measured by CECE influence and regulate the unique transport characteristics of each confinement regime, including L-mode, I-mode, ELMy H-mode, and ELM-free H-mode. Optics and signal processing methods to aid in the analysis and interpretation of experimental turbulence results are also presented. These methods, and particularly the down-sampling and ensemble averaging method, are relevant to a wide variety of fusion and non-fusion applications.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Photoinduced molecular chirality probed by ultrafast resonant X-ray spectroscopy

Recently developed circularly polarized X-ray light sources can probe the ultrafast chiral electronic and nuclear dynamics through spatially localized resonant core transitions. Here, we present simulations of time-resolved circular dichroism signals given by the difference of left and right circularly polarized X-ray probe transmission following an excitation by a circularly polarized optical pump with the variable time delay. Application is made to formamide which is achiral in the ground state and assumes two chiral geometries upon optical excitation to the first valence excited state. Probes resonant with various K-edges (C, N, and O) provide different local windows onto the parity breaking geometry change thus revealing the enantiomer asymmetry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A compact fiber optics-based heterodyne combined normal and transverse displacement interferometer

While Photonic Doppler Velocimetry (PDV) has become a common diagnostic tool for the measurement of normal component of particle motion in shock wave experiments, this technique has not yet been modified for the measurement of combined normal and transverse motion, as needed in oblique plate impact experiments. In this study, we discuss the design and implementation of a compact fiber-optics-based heterodyne combined normal and transverse displacement interferometer. Like the standard PDV, this diagnostic tool is assembled using commercially available telecommunications hardware and uses a 1550 nm wavelength 2 W fiber-coupled laser, an optical focuser, and single mode fibers to transport light to and from the target. Two additional optical probes capture first-order beams diffracted from a reflective grating at the target free-surface and deliver the beams past circulators and a coupler where the signal is combined to form a beat frequency. The combined signal is then digitized and analyzed to determine the transverse component of the particle motion. The maximum normal velocity that can be measured by this system is limited by the equivalent transmission bandwidth (3.795 GHz) of the combined detector, amplifier, and digitizer and is estimated to be ~2.9 km/s. Finally, sample symmetric oblique plate-impact experiments are performed to demonstrate the capability of this diagnostic tool in the measurement of the combined normal and transverse displacement particle motion.

47 OTHER INSTRUMENTATION↗

High-sensitivity electronic Stark spectrometer featuring a laser-driven light source

We report developmental details of a high-sensitivity Stark absorption spectrometer featuring a laser-driven light source. The light source exhibits intensity fluctuations of ~0.3% over timescales ranging from 1 min to 12 h, minimal drift (≤0.1%/h), and very little 1/f noise at frequencies greater than 200 Hz, which are comparable to or better than an arc-driven light source. Additional features of the spectrometer include balanced detection with multiplex sampling, which yielded lower noise in A, and constant wavelength or wavenumber (energy) spectral bandpass modes. We achieve noise amplitudes of ~7 × 10 –4 and ~6 × 10 –6 in measurements of single A and ΔA spectra (with 92 data points) taking ~7 and ~19 min, respectively.

47 OTHER INSTRUMENTATION↗

Signal processing to reduce dark noise impact in precision timing

We introduce a technique to mitigate the effects of low frequency noise on precision timing. The example of Dark Count Noise Rate (DCR) in Silicon Photomultipliers (SiPMs) is emphasized. This technique exploits the correlation between time shifts on the leading edge of a signal and the residual slope of the baseline (due to noise) which remains after baseline subtraction. In fast timing applications (such as for Time-of-flight particle ID) the signal arrival time is typically captured on the signal leading edge. The signal risetime is often fixed by the physics of the sensor and input circuit. Then accurate pulse timing can be achieved by correcting a leading edge threshold time (depending on a slope proportional to both the Amplitude and the risetime) to a “constant fraction” time. This compensation for time walk due to amplitude fluctuations breaks down once we introduce interference from low frequency noise on the leading edge. In this paper we demonstrate that an additional measurement of the slope at threshold can be used to correct for this noise jitter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A tamper-indicating quantum seal

Technical means for identifying when tampering occurs is a critical part of many containment and surveillance technologies. Conventional fiber optic seals provide methods for monitoring enclosed inventories, but they are vulnerable to spoofing attacks based on classical physics. We address these vulnerabilities with the development of a quantum seal that offers the ability to detect the intercept-resend attack using quantum integrity verification. Our approach represents an application of entanglement to provide guarantees in the authenticity of the seal state by verifying it was transmitted coherently. We implement these ideas using polarization-entangled photon pairs that are verified after passing through a fiber-optic channel testbed. Using binary detection theory, we find the probability of detecting inauthentic signals is greater than 0.9999 with a false alarm chance of 10 –9 for a 10 second sampling interval. In addition, we show how the Hong-Ou-Mandel effect concurrently provides a tight bound on redirection attack, in which tampering modifies the shape of the seal. Our measurements limit the tolerable path length change to sub-millimeter disturbances. As a result, these tamper-indicating features of the quantum seal offer unprecedented security for unattended monitoring systems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Laser velocimetry: A state-of-the-art overview

General systems design and optical and signal processing requirements for laser velocimetric measurement of flows are reviewed. Bias errors which occur in measurements using burst (counter) processors are discussed and particle seeding requirements are suggested.

Stevenson, W. H.↗

Net Photorefractive Gain In Gallium Arsenide

Prerequisite includes applied electric field. Electric field applied to GaAs crystal in which two infrared beams interfere. Depending on quality of sample and experimental conditions, net photorefractive gain obtained. Results offer possibility of new developments in real-time optical processing of signals by use of near-infrared lasers of low power.

Liu, Tsuen-Hsi↗

Optical Johnson noise thermometry

A concept is being explored that an optical analog of the electrical Johnson noise may be used to measure temperature independently of emissivity. The concept is that a laser beam may be modulated on reflection from a hot surface by interaction of the laser photons with the thermally agitated conduction electrons or the lattice phonons, thereby adding noise to the reflected laser beam. If the reflectance noise can be detected and quantified in a background of other noise in the optical and signal processing systems, the reflectance noise may provide a noncontact measurement of the absolute surface temperature and may be independent of the surface's emissivity.

Shepard, R. L.↗

An overview of in-flight plume diagnostics for rocket engines

An overview and progress report of the work performed or sponsored by LeRC toward the development of in-flight plume spectroscopy technology for health and performance monitoring of liquid propellant rocket engines are presented. The primary objective of this effort is to develop technology that can be utilized on any flight engine. This technology will be validated by a hardware demonstration of a system capable of being retrofitted onto the Space Shuttle Main Engines for spectroscopic measurements during flight. The philosophy on system definition and status on the development of instrumentation, optics, and signal processing with respect to implementation on a flight engine are discussed.

Madzsar, G. C.↗

An overview of in-flight plume diagnostics for rocket engines

An overview and progress report of the work performed or sponsored by LeRC toward the development of in-flight plume spectroscopy technology for health and performance monitoring of liquid propellant rocket engines are presented. The primary objective of this effort is to develop technology that can be utilized on any flight engine. This technology will be validated by a hardware demonstration of a system capable of being retrofitted onto the Space Shuttle Main Engines for spectroscopic measurements during flight. The philosophy on system definition and status on the development of instrumentation, optics, and signal processing with respect to implementation on a flight engine are discussed.

Madzsar, G. C.↗

Laser anemometry - Advances and applications 1991; Proceedings of the 4th International Conference, Cleveland, OH, Aug. 5-9, 1991. Vols. 1 & 2

The papers presented in this volume provide an overview of the latest advances in laser anemometry and optical flow diagnostics. Topics discussed include turbulence, jets, and chaos; novel optical techniques for velocity measurements; chemical reactions and combusting flows; and LDA/CFD interface. Attention is also given to particle image velocimetry, high speed flows and aerodynamic flows, internal flows, particle sizing, optics and signal processing, two-phase flows, and general fluid mechanics applications.

Dybbs, Alexander↗

Absolute Distance Measurement with the MSTAR Sensor

The MSTAR sensor (Modulation Sideband Technology for Absolute Ranging) is a new system for measuring absolute distance, capable of resolving the integer cycle ambiguity of standard interferometers, and making it possible to measure distance with sub-nanometer accuracy. The sensor uses a single laser in conjunction with fast phase modulators and low frequency detectors. We describe the design of the system - the principle of operation, the metrology source, beamlaunching optics, and signal processing - and show results for target distances up to 1 meter. We then demonstrate how the system can be scaled to kilometer-scale distances.

modulation sideband technology for absolute rangin↗

Optical seismic sensor systems and methods

Disclosed is an optical seismic sensor system for measuring seismic events in a geological formation, including a surface unit for generating and processing an optical signal, and a sensor device optically connected to the surface unit for receiving the optical signal over an optical conduit. The sensor device includes at least one sensor head for sensing a seismic disturbance from at least one direction during a deployment of the sensor device within a borehole of the geological formation. The sensor head includes a frame and a reference mass attached to the frame via at least one flexure, such that movement of the reference mass relative to the frame is constrained to a single predetermined path.

47 OTHER INSTRUMENTATION↗

Partial discharge sensor

An approach to detecting partial discharge events involves retrofitting an electrical system to include a capacitive sensor configured to capacitively sense partial discharge events of a component of the electrical system. The capacitive sensor has a first electrical conductor that forms a first terminal of the capacitive sensor, a second electrical conductor that forms a second terminal of the capacitive sensor, and a dielectric that separates the first electrical conductor and the second electrical conductor. The capacitive sensor generates an electrical sensor signal at an output of the capacitive sensor in response to the partial discharge event. The electrical sensor signal is converted to an optical signal and the optical signal is processed to detect an occurrence of the partial discharge event.

Karin, Todd↗