Search NASA⌕ Search

SEARCH · Search NASA

Results for “Overall Cooling Effectiveness”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Distortion and Residual Stress Control in Integrally Stiffened Structure Produced by Direct Metal Deposition

2-D thermo-mechanical model developed to characterize distortion and residual stresses in integral structure produced by DMD. Demonstrated as a tool to guide experimental development of DMD fabrication process for aero structures. Distortion and residual stresses are local to deposit. Most distortion develops during deposition of the first few layers; Little change in distortion or residual stresses after fifth deposit layer Most of distortion is localized just beneath the build. Thicker build plates and the use of build lands results in greatest decrease in levels of distortion. Pre-straining shown to reduce distortion. Difficult to implement, particularly for complex stiffener arrays. Clamp position has complex effect on distortion and stresses. Overall distortion reduced with decreasing clamp clearance. Larger clamp clearances induce bending. Use of pre-heat and active cooling show minor influence on panel distortion. Generate changes in thermal gradients in the build plate.

Lin, Shih-Yung↗

Hot-tail electrons’ impact on assimilation and injection penetration of D2 shattered pellet injections

The assimilation and the penetration of injected materials play significant roles in the mitigation efficiency of shattered pellet injection (SPI) as a disruption mitigation system (DMS), hence an accurate description of the fragment ablation rate is desirable. Current mainstream 3D MHD codes modelling SPIs mostly assume instantaneous thermalization between the previously hot ambient electrons and the newly released cold electrons. This could result in underestimation of the ablation rate if the hot electron thermalization time is comparable or even longer than the fragment flying time across flux tubes, putting the validity of these 3D SPI simulations into question. To resolve this doubt, we, in this study, investigate the thermalization dynamics and the overall hot-electron impact. The finite-time collisional thermalization of hot-tail electrons in a rapidly cooling plasma, as well as the so-called ‘self-limiting’ effect are considered. The former effect tends to deplete the colder population within a hot-tail species, while the latter is found to preferentially deplete the higher energy population. The combined result is found to cause an almost self-similar decay of the hot electron distribution function, while its shape does not deviate much from that of Maxwellian distribution and the mean energy does not change much during the thermalization process. Based on this observation, axisymmetric JOREK D2 SPI simulations were carried out with additional hot-tail contribution to evaluate their overall impact onto the injection assimilation and penetration. It is found that the hot-tail effect indeed causes enhanced assimilation and shallower penetration, although the overall effect depends on the exact injection configuration, with the slow injection showing negligible hot-tail effect while the fast single non-shattered pellet case shows drastic hot-tail ablation enhancement. For ITER-like SPI parameters, there is no significant deviation in the total assimilation, but some deviation in the injection penetration is observed for the fast injection velocity cases.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Solar photochemical process engineering for production of fuels and chemicals

The engineering costs and performance of a nominal 25,000 scmd (883,000 scfd) photochemical plant to produce dihydrogen from water were studied. Two systems were considered, one based on flat-plate collector/reactors and the other on linear parabolic troughs. Engineering subsystems were specified including the collector/reactor, support hardware, field transport piping, gas compression equipment, and balance-of-plant (BOP) items. Overall plant efficiencies of 10.3 and 11.6% are estimated for the flat-plate and trough systems, respectively, based on assumed solar photochemical efficiencies of 12.9 and 14.6%. Because of the opposing effects of concentration ratio and operating temperature on efficiency, it was concluded that reactor cooling would be necessary with the trough system. Both active and passive cooling methods were considered. Capital costs and energy costs, for both concentrating and non-concentrating systems, were determined and their sensitivity to efficiency and economic parameters were analyzed. The overall plant efficiency is the single most important factor in determining the cost of the fuel.

Biddle, J. R.↗

Analysis of Regen Cooling in Rocket Combustors

The use of detailed CFD modeling for the description of cooling in rocket chambers is discussed. The overall analysis includes a complete three-dimensional analysis of the flow in the regenerative cooling passages, conjugate heat transfer in the combustor walls, and the effects of film cooling on the inside chamber. The results in the present paper omit the effects of film cooling and include only regen cooling and the companion conjugate heat transfer. The hot combustion gases are replaced by a constant temperature wall boundary condition. Load balancing for parallel cluster computations is ensured by using single-block unstructured grids for both fluids and solids, and by using a 'multiple physical zones' to account for differences in the number of equations. Validation of the method is achieved by comparing simple two-dimensional solutions with analytical results. Representative results for cooling passages are presents showing the effects of heat conduction in the copper walls with tube aspect ratios of 1.5:l.

Harper, Brent↗

Solar photochemical process engineering for production of fuels and chemicals

The engineering costs and performance of a nominal 25,000 scmd (883,000 scfd) photochemical plant to produce dihydrogen from water were studied. Two systems were considered, one based on flat-plate collector/reactors and the other on linear parabolic troughs. Engineering subsystems were specified including the collector/reactor, support hardware, field transport piping, gas compression equipment, and balance-of-plant (BOP) items. Overall plant efficiencies of 10.3 and 11.6 percent are estimated for the flat-plate and trough systems, respectively, based on assumed solar photochemical efficiencies of 12.9 and 14.6 percent. Because of the opposing effects of concentration ratio and operating temperature on efficiency, it was concluded that reactor cooling would be necessary with the trough system. Both active and passive cooling methods were considered. Capital costs and energy costs, for both concentrating and non-concentrating systems, were determined and their sensitivity to efficiency and economic parameters were analyzed. The overall plant efficiency is the single most important factor in determining the cost of the fuel.

Biddle, J. R.↗

Effects of oxidation and roughness on Cu contact resistance from 4 to 290 K

Knowledge of the factors influencing contact resistance is important for optimizing system design in cryogenic applications. In space cryogenics, indirect cooling of infrared components is the primary concern. The presence of bolted joints results in contact resistances which can dominate all other contributions to the overall heat transfer rate. Here, thermal and electrical contact resistances measured between 4 K and 290 K for a series of bolted OFHC Cu contacts are reported. Surface roughness is found to have little effect on the overall contact resistance within the experimental limits, while oxidation can increase the contact resistance by as much as a factor of 100. Thermal and electrical contact resistances measured on the same contact show that the contact resistance temperature dependence does not follow the bulk dependence. For example, the residual resistance ratio (RRR) of the OFHC Cu is 110, but for contacts made from this material, the RRR is about two.

Nilles, M. J.↗

Case Study of Integrating High-Temperature Heat Pump with LiBr-H2O Absorption Chiller for Data Center Liquid Cooling

Data centers (DCs) are physical infrastructures that support artificial intelligence workloads. The rapid growth of artificial intelligence is putting substantial pressure on the US power grid. Most of electricity consumed by IT equipment, accounting for 50%-60% of total DC power, ultimately becomes waste heat. This heat is dissipated by DC’s cooling facilities, accounting for an additional 30%-40% of total DC power. Recovering and repurposing this waste heat offers a significant opportunity to enhance energy efficiency and reduce operating costs of DCs. One potential pathway is converting heat to cold using thermal-driven absorption chillers, therefore, reducing the power consumption in DC cooling facilities. Existing studies mainly demonstrate the technical and economic feasibility of repurposing DC’s waste heat for cooling applications but provide limited technical details on how to integrate the thermal-driven absorption chillers with DC cooling systems. In addition, the low-grade waste heat available from DCs must be upgraded to higher temperatures suitable for absorption chillers. This paper presents a case study on integrating high-temperature heat pumps with a LiBr-H2O absorption chiller to use DC waste heat for cooling. A thermodynamic model of single-effect, LiBr-H2O absorption chiller and an empirical model of high-temperature heat pumps were built. The case study considers ASHRAE W17 liquid-cooled DC, with facility service water supplied at 17.0℃ and returned at 25.3℃. The thermal behaviors of absorption chiller components were predicted for the generation temperature ranging from 75.0℃ to 115.0℃. Based on the available waste heat in the integrated system, two waste heat recovery strategies were evaluated: a facility service water-based strategy and cooling water-based strategy. Results indicated that the cooling water-based strategy achieves higher Coefficient of Performance (COPs) than the facility service water-based strategy. The relatively low cooling COPs of single-effect LiBr-H2O absorption chillers could be offset by high heating COP of high temperature heat pumps. The maximum cooling COP of absorption chiller and the overall COP of integrated systems occur at lower generation temperatures, but these conditions also yield lower cooling capacities. In practice, system operation should balance the trade-off between the COP and cooling capacity

Wang, Pengtao [ORNL] (ORCID:0000000214713429)↗

Standardization of Rocket Engine Pulse Time Parameters

Plumes of bipropellant thrusters are a source of contamination. Small bipropellant thrusters are often used for spacecraft attitude control and orbit correction. Such thrusters typically operate in a pulse mode, at various pulse lengths. Quantifying their contamination effects onto spacecraft external surfaces is especially important for long-term complex-geometry vehicles, e.g. International Space Station. Plume contamination tests indicated the presence of liquid phase contaminant in the form of droplets. Their origin is attributed to incomplete combustion. Most of liquid-phase contaminant is generated during the startup and shutdown (unsteady) periods of thruster pulse. These periods are relatively short (typically 10-50 ms), and the amount of contaminant is determined by the thruster design (propellant valve response, combustion chamber size, thruster mass flow rate, film cooling percentage, dribble volume, etc.) and combustion process organization. Steady-state period of pulse is characterized by much lower contamination rates, but may be lengthy enough to significantly conh'ibute to the overall contamination effect. Because there was no standard methodology for thruster pulse time division, plume contamination tests were conducted at various pulse durations, and their results do not allow quantifying contaminant amounts from each portion of the pulse. At present, the ISS plume contamination model uses an assumption that all thrusters operate in a pulse mode with the pulse length being 100 ms. This assumption may lead to a large difference between the actual amounts of contaminant produced by the thruster and the model predictions. This paper suggests a way to standardize thruster startup and shutdown period definitions, and shows the usefulness of this approach to better quantify thruster plume contamination. Use of the suggested thruster pulse time-division technique will ensure methodological consistency of future thruster plume contamination test programs, and allow accounting for thruster pulse length when modeling plume contamination and erosion effects.

Larin, Max E.↗

TPSAS-NF1676L-36113-DND

Concerns about the effects of extreme heat and poor air quality are increasing in North America’s largest urban centers. In Philadelphia, environmental and public health groups are concerned about how these phenomena disproportionality affect marginalized communities and populations, which often have extensive impervious surfaces and little access to green space. In order to address these concerns, the Philadelphia Department of Public Health and the Office of Sustainability seek to effectively prioritize cooling initiatives to reduce urban heat and decrease air pollutants. We evaluated land surface temperature (LST) and the Normalized Difference Vegetation Index (NDVI), as a measure of overall greenness, obtained from NASA Earth observations Aqua and Terra Moderate Resolution Imaging Spectroradiometer (MODIS), and the Ecosystem Spaceborne Thermal Radiometer Experiment on Space Station (ECOSTRESS). These analyses we recombined with local tree inventory, air quality, and socioeconomic data through a multivariate analysis to identify areas where new trees or cooling adaptations are most needed. The results and data of this project can be used by our partners to inform both short-term heat relief planning and a long-term, multi-agency heat response.

Spencer Nelson↗

Topological Hall Effect in Antiferromagnetic Co-Doped Fe 3 GaTe 2

Fe 3 GaTe 2 is van der Waals (vdW) ferromagnet with a Curie temperature T C ranging from 350 K to 380 K, followed upon cooling by a ferrimagnetic transition near room temperature. Substituting Fe with Co was previously reported to induce antiferromagnetism (AFM) at a Co fraction dependent Néel temperature TN. In this work, we confirm the overall phase diagram of the Fe 3-x Co x GaTe 2 series as a function of x and temperature via magnetization and electrical transport measurements. For x ≥ 0.6 the Hall effect is observed to mimic the magnetization as the AF ground state is suppressed by the external magnetic field via a metamagnetic transition, thus displaying an anomalous Hall response. At low temperatures, we also observe a pronounced topological Hall signal peaking at μ 0 H = 4 T, or within the metamagnetic transition region of fields. This observation points to the presence of magnetic field-induced chiral spin textures, such as skyrmions upon approaching magnetization saturation. Remarkably, magnetic force microscopy (MFM) reveals the emergence of nearly circular magnetic domains, with diameters on the order of 100–200 nm, within the antiferromagnetic phase. Here, a detailed analysis of the MFM images indicates that the topological Hall effect is closely linked to the field-induced stabilization of magnetic domain structures, likely exhibiting chiral textures. This observation suggests the possible formation of skyrmions already in the AFM phase, i.e., AFM skyrmions, that evolve into ferromagnetic (FM) ones upon increasing the magnetic field. Consequently, Co-doped Fe 3 GaTe 2 might provide a platform to investigate the transformation of skyrmions, initially coupled antiferromagnetically into ferromagnetic skyrmions, and to explore its impact on the topological and skyrmion Hall effects.

anomalous Hall effect↗

A 12,000-year record of vertical deformation across the Yellowstone caldera margin: The shorelines of Yellowstone Lake

The 600 ka Yellowstone caldera exhibits several signs of unrest, the most evident of which is historic ground deformation including both uplift and subsidence. We document deformation in the area of the southern caldera across approximately 12,000 years using the postglactic shoreline terraces of Yellowstone Lake. Raised shoreline elevations were interpreted from 230 leveling profiles surveyed across flights of terraces, with an accuracy of +/- 0.5 m. Of about 11 recognizable terraces, the five most continuous raised shorelines were correlated around the lake basin to reveal deformation patterns. Net deformation over the past approximatley 3 kyr has been dominantly up within the caldera interior and slightly down along the caldera rim, relative to the extracaldera region. This uplift is roughly similar to the historic pattern and may largely represent the effects of the most recent inflation episode. Subtraction of the total estimated magnitude of inflation in this epsiode suggests that the overall trend of postglacial deformation has been subsidence. The cause of this trend is undetermined but is most likely related to the effects of regional extension and long-term cooling within the Yellowstone caldera.

Locke, William W.↗

Thermoeconomic cost optimization of superconducting magnets for proton therapy gantries

A compact gantry delivering 70-220 MeV protons with fixed field in the superconducting magnets could reduce the cost and improve the adoption of proton therapy. While a number of magnet and cryogenics designs have been proposed, the combined capital and operating costs of state-of-the-art superconducting materials have not been analyzed. In response, we develop a thermoeconomic model of a multi-stage, conduction cooled gantry lattice and analyze the cryocooler operating cost, cryocooler capital cost and conductor capital cost for Nb-Ti, Nb 3 Sn, REBCO and Bi-2223 over a continuous range of magnet temperatures, and a differential evolution algorithm is used to identify the optimal combination of thermal intercept temperatures. Although Nb3Sn yields the lowest Net Present Value (NPV) of $111.7k at a magnet temperature of 9.4 K, the optimized Bi-2223 design at 12.8 K approaches the realm of commercial feasibility by offering improved thermal stability and forgoing the need for costly conductor heat treatment and magnet quench training. Furthermore, it was found that Nb3Sn was more cost effective than Nb-Ti and that REBCO was not economically viable for the parameters of this investigation. Overall, the thermoeconomic model developed herein can optimize conductor choices, magnet temperatures and thermal staging which has value for any conduction-cooled superconducting magnet.

BSCCO↗

Harvest and nitrogen effects on bioenergy feedstock quality of grass-legume mixtures on Conservation Reserve Program grasslands

Perennial grass mixtures established on Conservation Reserve Program (CRP) lands can be an important source of feedstock for bioenergy production. This study aimed to evaluate management practices for optimizing the quality of bioenergy feedstock and stand persistence of grass-legume mixtures under diverse environments. A 5-year field study (2008–2012) was conducted to assess the effects of two harvest timings (at anthesis vs after complete senescence) and three nitrogen (N) rates (0, 56, 112 kg N ha -1 ) on biomass chemical compositions (i.e., cell wall components, ash, volatiles, total carbon, and N contents) and the feedstock energy potential, examined by the theoretical ethanol yield (TEY) and the total TEY (i.e., the product of biomass yield and TEY, L ha -1 ), of cool-season mixtures in Georgia and Missouri and a warm-season mixture in Kansas. The canonical correlation analysis (CCA) was used to investigate the effect of vegetative species transitions on feedstock quality. Although environmental variations (mainly precipitation) greatly influenced the management effect on chemical compositions, the delayed harvest after senescence generally improved feedstock quality. In particular, the overall cell wall concentrations and TEY of the warm-season mixtures increased by approximately 7%. Additional N supplies improved the total TEY of both mixtures by ~1.6–4.2 L ha -1 per 1.0 kg N ha -1 input but likely lowered the feedstock quality, particularly for the cool-season mixture. The cell wall concentrations of cool-season mixture reduced by approximately 3%–6%. The CCA results indicated that the increased legume compositions (under low N input) likely enhanced lignin but reduced ash concentrations. This field research demonstrated that with proper management, grass-legume mixtures on CRP lands can provide high-quality feedstock for bioenergy productions.

09 BIOMASS FUELS↗

The importance of accounting for the Tolman correction to surface tension for nucleation and growth modeling of Fe clusters

Gibbs free energies of clusters are required for predictive modeling of cluster growth during condensation of a cooling vapor. Here, we present a straightforward method of calculating free energies of cluster formation using the data from molecular dynamics (MD) simulations. We apply this method to iron clusters having from 2 to 100 atoms. The energies obtained are verified by comparing to an MD-simulated equilibrium cluster size distribution in a sub-saturated vapor. We show that these free energies differ significantly from those obtained with a commonly used spherical cluster approximation, which relies on a surface tension coefficient of a flat surface, as it is used in the classical nucleation theory (CNT). We show that the spherical cluster approximation in CNT can be improved by using a cluster-size-dependent Tolman correction for the surface tension. The Tolman length and effective surface tension values were derived for iron clusters, and they significantly differ from the commonly used experimentally measured values. This improved approximation does not account for geometric magic number effects responsible for spikes and troughs in densities of neighbor cluster sizes. Nonetheless, it allows to more accurately model cluster formation from a cooling vapor. It better reproduces the condensation timeline, overall shape of the cluster size distribution, average cluster size, and the distribution width. In contrast, using a constant surface tension coefficient (as done in CNT) resulted in incorrect condensation dynamics and cluster size distributions. The analytical expression for cluster nucleation rate from CNT was updated to account for the size-dependence of cluster surface tension.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The polar stratospheric cloud event of January 24, 1989. I - Microphysics

Rapid adiabatic cooling induced by synoptic forcing led to polar stratospheric cloud (PSC) formation on January 24, 1989, at altitudes sampled by the ER-2 aircraft. Particle characteristics measured by the Forward Scattering Spectrometer Probe (FSSP) on the ER-2 were compared to those calculated using a theoretical PSC microphysics model. Although calculations were sensitive to local changes in cooling rate, generally favorable agreement was found, that in particle surface area being especially important since this parameter dictates heterogeneous chemical rates. The overall model performance suggests that the current approach for simulating Type 1 (nitric acid trihydrate) PSC formation under rapid cooling conditions is well founded and can be used to study the effects of heterogeneous chemistry on stratospheric composition.

Poole, L. R.↗

Supersonic Free-Jet Combustion in a Ramjet Burner

A new dual-mode ramjet combustor concept intended for operation over a wide flight Mach number range is described. Subsonic combustion mode is similar to that of a traditional ram combustor which allows operation at higher efficiency, and to lower flight Mach numbers than current dual-mode scramjets. High speed mode is characterized by supersonic combustion in a free-jet that traverses the subsonic combustion chamber to a variable nozzle. The maximum flight Mach number of this scheme is governed largely by the same physics as its classical counterpart. Although a variable combustor exit aperture is required, the need for fuel staging to accommodate the combustion process is eliminated. Local heating from shock-boundary-layer interactions on combustor walls is also eliminated. Given the parallel nature of the present scheme, overall flowpath length is less than that of present dual-mode configurations. Cycle analysis was done to define the flowpath geometry for computational fluid dynamics (CFD) analysis, and then to determine performance based on the CFD results. CFD results for Mach 5, 8, and 12 flight conditions indicate stable supersonic free-jet formation and nozzle reattachment, thereby establishing the basic feasibility of the concept. These results also reveal the structure of, and interactions between the free-jet and recirculating combustion chamber flows. Performance based on these CFD results is slightly less than that of the constant-pressure-combustion cycle analysis primarily due to these interactions. These differences are quantified and discussed. Additional CFD results at the Mach 8 flight condition show the effects of nozzle throat area variation on combustion chamber pressure, flow structure, and performance. Calculations with constant temperature walls were also done to evaluate heat flux and overall heat loads. Aspects of the concept that warrant further study are outlined. These include diffuser design, ramjet operation, mode transition, loss mechanisms, and the effects of secondary flow for wall cooling and combustion chamber pressurization. Also recommended is an examination of system-level aspects such as weight, thermal management and rocket integration as well as alternate geometries and variable geometry schemes.

Trefny, Charles J.↗

A computational analysis of effective R-values of buried ducts – the dynamic performance of buried ducts

Here, this paper evaluates the thermal performance of ducts partially or fully buried in loose-fill attic insulation. The overall thermal resistance between the ducts and the attic is referred to as an effective R-value. This paper shows a strong dependency of assumed attic temperature on the effective R-value. Based on the results, the effective R-value can be about twice as much with an attic temperature of 130 °F [54.4 °C], compared to when the attic temperature is 80 °F [26.7 °C]. Thus, this paper provides a polynomial regression equation based on a large set of simulations to determine the effective R-value of buried ducts depending on attic temperature and whether the HVAC system runs in cooling or heating mode. Further, the work presented in this paper investigated the potential impact of convective airflow within the attic insulation, particularly around the ducts. The analysis was based on computational fluid dynamics (CFD) and indicated that convectional forces are presented around the exterior surface of the ducts, but with negligible impact on the overall heat balance between the duct and the attic space.

97 MATHEMATICS AND COMPUTING↗

The Installation of Direct Water-Cooling Systems to Reduce Cooling Energy Requirements for High-Performance Computing Centers

A large cluster of High-Performance Computing (HPC) equipment at the Lawrence Livermore National Laboratory in California was retrofitted with an Asetek cooling system. The Asetek system is a hybrid scheme with water-cooled cold plates on high-heat-producing components in the information technology (IT) equipment, and with the remainder of the heat being removed by conventional air-cooling systems. In order to determine energy savings of the Asetek system, data were gathered and analyzed two ways: using top-down statistical models, and bottom-up engineering models. The cluster, “Cabernet”, rejected its heat into a facilities cooling water loop which in turn rejected the heat into the same chilled water system serving the computer-room air handlers (CRAHs) that provided the air-based cooling for the room. Because the “before” and “after” cases both reject their heat into the chilled water system, the only savings is due to reduction in CRAH fan power. The top-down analysis showed a 4% overall energy savings for the data center (power usage effectiveness (PUE) —the ratio of total data center energy to IT energy— dropped from 1.60 to 1.53, lower is better); the bottom-up analysis showed a 3% overall energy savings (PUE from 1.70 to 1.66) and an 11% savings for the Cabernet system by itself (partial PUE of 1.51). Greater savings, on the order of 15-20%, would be possible if the chilled water system was not used for rejecting the heat from the Asetek system. About 37% of the heat from the Cab system was rejected to the cooling water, lower than at other installations.

Earni, Shankar↗