Search NASA⌕ Search

SEARCH · Search NASA

Results for “PARTICULATE FILTER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Evolution of the Lunar Receiving Laboratory to the Astromaterial Sample Curation Facility: Technical Tensions Between Containment and Cleanliness, Between Particulate and Organic Cleanliness

The Lunar Receiving Laboratory (LRL) was planned and constructed in the 1960s to support the Apollo program in the context of landing on the Moon and safely returning humans. The enduring science return from that effort is a result of careful curation of planetary materials. Technical decisions for the first facility included sample handling environment (vacuum vs inert gas), and instruments for making basic sample assessment, but the most difficult decision, and most visible, was stringent biosafety vs ultra-clean sample handling. Biosafety required handling of samples in negative pressure gloveboxes and rooms for containment and use of sterilizing protocols and animal/plant models for hazard assessment. Ultra-clean sample handling worked best in positive pressure nitrogen environment gloveboxes in positive pressure rooms, using cleanable tools of tightly controlled composition. The requirements for these two objectives were so different, that the solution was to design and build a new facility for specific purpose of preserving the scientific integrity of the samples. The resulting Lunar Curatorial Facility was designed and constructed, from 1972-1979, with advice and oversight by a very active committee comprised of lunar sample scientists. The high precision analyses required for planetary science are enabled by stringent contamination control of trace elements in the materials and protocols of construction (e.g., trace element screening for paint and flooring materials) and the equipment used in sample handling and storage. As other astromaterials, especially small particles and atoms, were added to the collections curated, the technical tension between particulate cleanliness and organic cleanliness was addressed in more detail. Techniques for minimizing particulate contamination in sample handling environments use high efficiency air filtering techniques typically requiring organic sealants which offgas. Protocols for reducing adventitious carbon on sample handling surfaces often generate particles. Further work is needed to achieve both minimal particulate and adventitious carbon contamination. This paper will discuss these facility topics and others in the historical context of nearly 50 years' curation experience for lunar rocks and regolith, meteorites, cosmic dust, comet particles, solar wind atoms, and asteroid particles at Johnson Space Center.

Allton, J. H.↗

Design of high pressure oxygen filter for extravehicular activity life support system, volume 1

The experience of the National Aeronautics and Space Administration (NASA) with extravehicular activity life support emergency oxygen supply subsystems has shown a large number of problems associated with particulate contamination. These problems have resulted in failures of high pressure oxygen component sealing surfaces. A high pressure oxygen filter was designed which would (a) control the particulate contamination level in the oxygen system to a five-micron glass bead rating, ten-micron absolute condition (b) withstand the dynamic shock condition resulting from the sudden opening of 8000 psi oxygen system shutoff valve. Results of the following program tasks are reported: (1) contaminant source identification tests, (2) dynamic system tests, (3) high pressure oxygen filter concept evaluation, (4) design, (5) fabrication, (6) test, and (7) application demonstration.

Wilson, B. A.↗

Fiber length and orientation prevent migration in fluid filters

Stainless steel fiber web filter resists fiber migration which causes contamination of filtered fluids. This filter is capable of holding five times more particulate matter before arbitrary cutoff pressure drop and shows excellent retention in fuel flow at high rates.

Reiman, P. A.↗

Near Real-Time Sub/Seasonal Prediction of Aerosol and Air Quality at the NASA Global Modeling and Assimilation Office

Version 2 of the coupled modeling and analysis system used to produce near real time subseasonal to seasonal forecasts was released almost two years ago by the NASA/Goddard Global Modeling and Assimilation Office. The model runs at approximately 1/2 degree globally in the atmosphere and ocean, contains a realistic description of the cryosphere, and includes an interactive aerosol model. The data assimilation used to produce initial conditions is weakly coupled, in which the atmosphere-only assimilated state is coupled to an ocean data assimilation system using a Local Ensemble Transform Kalman Filter. Results of aerosol-derived air quality (Particulate Matter) from an extensive series of retrospective forecasts will be shown, with particular focus on the continental United States and eastern Asia. In addition, under some circumstances, the interactive aerosol is shown to improve seasonal time scale prediction skill. Plans for a future version of the system with predicted biomass burning from fires will also be discussed.

Molod, Andrea↗

An intercomparison of measurement systems for vapor and particulate phase concentrations of formic and acetic acids

During June 1986, eight systems for measuring vapor phase and four for measuring particulate phase concentrations of formic acid (HCOOH) and acetic acid (CH3COOH) were intercompared in central Virginia. HCOOH and CH3COOH vapors were sampled by condensate, mist, Chromosorb 103 GC resin, NaOH-coated annular denuders, NaOH-impregnated quartz filters, K2CO3 and NaCO3-impregnated cellulose filters, and Nylasorb membranes. Atmospheric aerosol was collected on Teflon and Nuclepore filters using both hi-vol and lo-vol systems to measure particulate phase concentrations. Performances of the mist chamber and K2CO3-impregnated filter techniques were evaluated using zero air and ambient air spiked with HCOOH(g) and CH3COOH(g), and formaldehyde from permeation sources. The advantages and drawbacks of these methods are reported and discussed.

Keene, William C.↗

Lessons Learned from Particulate Characterization Laboratory Anomalies

The White Sands Test Facility chemistry laboratory provides quality control for cleanroom operations including cleanliness verification of aerospace hardware by particulate counts and non-volatile residue determinations, particulate counts for liquid hypergolic propellants, gaseous helium and nitrogen propellant pressurizing agents used for ground support equipment and flight test article valve actuation, gaseous oxygen primarily used for component testing, and deionized water for refurbished propellant hardware flushing. Cleanliness verification includes particulate counts and non-volatile residue determinations to industry standard, NASA, and program specifications and levels. Particulate counts are typically to customer-specified specifications and levels including JPR 5322.1H (2016) Levels 50 and 100, Orion (MPCV 70156. Revision H (2018)) Level 100, RPTSTD-8070-0001 Revision 3 (2022), and IEST-STD-CC1246E (2013) Levels 50 and 100. The laboratory issues high pressure filter holders containing membrane filters to test operations personnel, who collect samples by flowing the required volumes of fluid through the filter holder, and the filter holder is returned to the lab for counting. A passing particulate count is required before testing may proceed. Rapid data reduction and issuing of reports indicating a pass or fail of the particulate specification are required. Corrective action and resampling invariably occurs if a sample fails. Consequently, the laboratory must maintain the highest degree of reliability to facilitate quality data used to decide if testing may proceed. Experience and continual improvements have enabled reliability. However, anomalies attributed to lab processes and hardware including filter holders, membranes, and Petri dishes have been encountered. This paper presents a summary of problems, solutions, successes, and lessons learned from particle counting experience for over 35 years.

Lessons Learned↗

A Two-Stage Regenerable Filter for Collection and Disposal of Carbon Fines

NASA is investigating the use of the Plasma Pyrolysis Assembly (PPA), which is a methane post-processing technology with the goal to recover hydrogen from the Carbon dioxide Reduction Assembly (CRA) currently onboard the International Space Station (ISS). The PPA can theoretically recover 75% of hydrogen from methane produced by the CRA. During methane processing the PPA creates roughly 40 mg/hr of carbon dust when operating at 4 crew member levels. The unwanted fines need to be removed from the stream to prevent any clogging of downstream components. The Regenerable Carbon Filter (RCF) was designed by Umpqua Research Company to address the carbon particulate created in the PPA. The RCF includes two stages. The first is an electrostatic precipitator designed to collect ultrafine particles. The second is a low pressure drop physical filter. Both filters are made of heat tolerant materials to allow regeneration of the filtration capacity by O2 oxidation of captured carbon. This paper will discuss the RCF hardware and test plans.

Filtration, Environmental Control, Life Support↗

Atmospheric particulate measurements in Norfolk, Virginia

Characterization of atmospheric particulates was conducted at a site near the center of Norfolk, Virginia. Air quality was measured in terms of atmospheric mass loading, particle size distribution, and particulate elemental composition for a period of 2 weeks. The objectives of this study were (1) to establish a mean level of air quality and deviations about this mean, (2) to ascertain diurnal changes or special events in air quality, and (3) to evaluate instrumentation and sampling schedules. Simultaneous measurements were made with the following instruments: a quartz crystal microbalance particulate monitor, a light-scattering multirange particle counter, a high-volume air sampler, and polycarbonate membrane filters. To assess the impact of meteorological conditions on air quality variations, continuous data on temperature, relative humidity, wind speed, and wind direction were recorded. Particulate elemental composition was obtained from neutron activation and scanning electron microscopy analyses of polycarbonate membrane filter samples. The measured average mass loading agrees reasonably well with the mass loadings determined by the Virginia State Air Pollution Control Board. There are consistent diurnal increases in atmospheric mass loading in the early morning and a sample time resolution of 1/2 hour seems necessary to detect most of the significant events.

Storey, R. W., Jr.↗

Surface composition of solid-rocket exhausted aluminum oxide particles

Particulate samples of aluminum oxide were collected on Teflon filters from the exhaust plume of the Space Shuttle (STS-61A, October 30, 1985) over the altitude interval 4.6-7.6 km immediately after launch. These particles were analyzed using SEM, energy-dispersive X-ray analysis, electron spectroscopy for chemical analysis, X-ray fluorescent spectroscopy, and conventional wet-chemical techniques. The samples were 0.6-1.0 percent surface-chlorided (chlorided meaning predominantly aluminum chlorides and oxychlorides, possibly including other adsorbed forms of chloride) by weight. This level of chloriding is about one-third of the amount determined previously from laboratory-prepared alumina and surface site samples of solid-rocket-produced alumina (SRPA) after both had been exposed to moist HCl vapor at temperatures down to ambient. This level is equivalent to previous laboratory results with samples exposed to moist HCl at temperatures above the boiling point of water. It is suggested that the present lower chloriding levels, determined for samples from a 'dry' Shuttle exhaust cloud, underscore the importance of a liquid water/hydrochloric acid phase in governing the extent of surface chloriding of SRPA. The reduced chloriding is not trivial with respect to potential physical/chemical modification of the SRPA particle surfaces and their corresponding interaction with the atmosphere.

Cofer, Wesley R., III↗

Removing Pathogens Using Nano-Ceramic-Fiber Filters

A nano-aluminum-oxide fiber of only 2 nanometers in diameter was used to develop a ceramic-fiber filter. The fibers are electropositive and, when formulated into a filter material (NanoCeram(TradeMark)), would attract electro-negative particles such as bacteria and viruses. The ability to detect and then remove viruses as well as bacteria is of concern in space cabins since they may be carried onboard by space crews. Moreover, an improved filter was desired that would polish the effluent from condensed moisture and wastewater, producing potable drinking water. A laboratory- size filter was developed that was capable of removing greater than 99.9999 percent of bacteria and virus. Such a removal was achieved at flow rates hundreds of times greater than those through ultraporous membranes that remove particles by sieving. Because the pore size of the new filter was rather large as compared to ultraporous membranes, it was found to be more resistant to clogging. Additionally, a full-size cartridge is being developed that is capable of serving a full space crew. During this ongoing effort, research demonstrated that the filter media was a very efficient adsorbent for DNA (deoxyribonucleic acid), RNA (ribonucleic acid), and endotoxins. Since the adsorption is based on the charge of the macromolecules, there is also a potential for separating proteins and other particulates on the basis of their charge differences. The separation of specific proteins is a major new thrust of biotechnology. The principal application of NanoCeram filters is based on their ability to remove viruses from water. The removal of more than 99.9999 percent of viruses was achieved by a NanoCeram polishing filter added to the effluent of an existing filtration device. NanoCeram is commercially available in laboratory-size filter discs and in the form of a syringe filter. The unique characteristic of the filter can be demonstrated by its ability to remove particulate dyes such as Metanyl yellow. Its particle size is only 2 nanometers, about the size of a DNA molecule, yet the NanoCeram syringe filter is capable of retaining the dyes as the fluid is passed through the syringe, without much back-pressure. Endotoxins, which are contaminants that are part of the residue of destroyed bacteria, can cause toxic shock and are therefore of major concern in pharmaceutical products. The NanoCeram syringe filter is capable of removing greater than 99.96 percent of the endotoxins.

Tepper, Frederick↗

A procedure for sizing propulsion system filter capacity

A propulsion system filter has the function of protecting downstream components from propellant-borne particulate matter. A the same time, it must be designed with sufficient capacity to ensure that it will not clog during the life of the spacecraft. This capacity can be quantitatively calculated by means of the procedure described here. Previous work has presented limited data which suggest that filter clogging is a function of the number and size of ingested particles. Cleaning specifications for propusion system components are also normally given in terms of the number and size of particles removed by the flow of test fluid. It is proposed here that the filter capacity be given in terms of the number and size of particles, which in turn may be convected to an equivalent quantity of test dust.

Jan, Darrell L.↗

Iridium emissions from Hawaiian volcanoes

Particle and gas samples were collected at Mauna Loa volcano during and after its eruption in March and April, 1984 and at Kilauea volcano in 1983, 1984, and 1985 during various phases of its ongoing activity. In the last two Kilauea sampling missions, samples were collected during eruptive activity. The samples were collected using a filterpack system consisting of a Teflon particle filter followed by a series of 4 base-treated Whatman filters. The samples were analyzed by INAA for over 40 elements. As previously reported in the literature, Ir was first detected on particle filters at the Mauna Loa Observatory and later from non-erupting high temperature vents at Kilauea. Since that time Ir was found in samples collected at Kilauea and Mauna Loa during fountaining activity as well as after eruptive activity. Enrichment factors for Ir in the volcanic fumes range from 10,000 to 100,000 relative to BHVO. Charcoal impregnated filters following a particle filter were collected to see if a significant amount of the Ir was in the gas phase during sample collection. Iridium was found on charcoal filters collected close to the vent, no Ir was found on the charcoal filters. This indicates that all of the Ir is in particulate form very soon after its release. Ratios of Ir to F and Cl were calculated for the samples from Mauna Loa and Kilauea collected during fountaining activity. The implications for the KT Ir anomaly are still unclear though as Ir was not found at volcanoes other than those at Hawaii. Further investigations are needed at other volcanoes to ascertain if basaltic volcanoes other than hot spots have Ir enrichments in their fumes.

Finnegan, D. L.↗

Variation in Global Chemical Composition of PM2.5: Emerging Results from SPARTAN

The Surface PARTiculate mAtter Network (SPARTAN) is a long-term project that includes characterization of chemical and physical attributes of aerosols from filter samples collected worldwide. This paper discusses the ongoing efforts of SPARTAN to define and quantify major ions and trace metals found in fine particulate matter (PM (sub 2.5). Our methods infer the spatial and temporal variability of PM (sub 2.5) in a cost-effective manner. Gravimetrically weighed filters represent multi-day averages of PM (sub 2.5), with a collocated nephelometer sampling air continuously. SPARTAN instruments are paired with AErosol RObotic NETwork (AERONET) sun photometers to better understand the relationship between ground-level PM (sub 2.5) and columnar aerosol optical depth (AOD). We have examined the chemical composition of PM (sub 2.5) at 12 globally dispersed, densely populated urban locations and a site at Mammoth Cave (US) National Park used as a background comparison. So far, each SPARTAN location has been active between the years 2013 and 2016 over periods of 2-26 months, with an average period of 12 months per site. These sites have collectively gathered over 10 years of quality aerosol data. The major PM (sub 2.5) constituents across all sites (relative contribution plus or minus Standard Deviation) are ammoniated sulfate (20 percent plus or minus 11 percent), crustal material (13.4 percent plus or minus 9.9 percent), equivalent black carbon (11.9 percent plus or minus 8.4 percent), ammonium nitrate (4.7 percent plus or minus 3.0 percent), sea salt (2.3 percent plus or minus 1.6 percent), trace element oxides (1.0 percent plus or minus 1.1 percent), water (7.2 percent plus or minus 3.3 percent) at 35 percent relative humidity, and residual matter (40 percent plus or minus 24 percent). Analysis of filter samples reveals that several PM (sub 2.5) chemical components varied by more than an order of magnitude between sites. Ammoniated sulfate ranges from 1.1 microns per cubic meter (Buenos Aires, Argentina) to 17 microns per cubic meter (Kanpur, India in the dry season). Ammonium nitrate ranged from 0.2 microns per cubic meter (Mammoth Cave, in summer) to 6.8 microns per cubic meter (Kanpur, dry season). Equivalent black carbon ranged from 0.7 microns per cubic meter (Mammoth Cave) to over 8 microns per cubic meter (Dhaka, Bangladesh and Kanpur, India). Comparison of SPARTAN vs. coincident measurements from the Interagency Monitoring of Protected Visual Environments (IMPROVE) network at Mammoth Cave yielded a high degree of consistency for daily PM (sub 2.5) (r squared equals 0.76, slope equals 1.12), daily sulfate (r squared equals 0.86, slope equals 1.03), and mean fractions of all major PM (sub 2.5) components (within 6 percent). Major ions generally agree well with previous studies at the same urban locations (e.g. sulfate fractions agree within 4 percent for 8 out of 11 collocation comparisons). Enhanced anthropogenic dust fractions in large urban areas (e.g. Singapore, Kanpur, Hanoi, and Dhaka) are apparent from high Zn to Al ratios. The expected water contribution to aerosols is calculated via the hygroscopicity parameter kappa (sub v (volume)) for each filter. Mean aggregate values ranged from 0.15 (Ilorin) to 0.28 (Rehovot). The all-site parameter mean is 0.20 plus or minus 0.04. Chemical composition and water retention in each filter measurement allows inference of hourly PM (sub 2.5) at 35 percent relative humidity by merging with nephelometer measurements. These hourly PM (sub 2.5) estimates compare favourably with a beta attenuation monitor (MetOne) at the nearby US embassy in Beijing, with a coefficient of variation r squared equals 0.67 (number equals 3167), compared to r squared equals 0.62 when v (volume) was not considered. SPARTAN continues to provide an open-access database of PM (sub 2.5) compositional filter information and hourly mass collected from a global federation of instruments.

Snider, Graydon↗

Ion chromatographic determination of anions collected on filters at altitudes between 9.6 and 13.7 kilometers

The investigation of atmospheric pollution to determine the anion-containing particulates in the atmosphere at altitudes between 9.6 and 13.7 km is discussed. Air samples collected on cellulose fiber discs impregnated with dibutoxyethylphthalate require very sensitive methods of analysis. It is concluded that ion chromatography is suited for the determination of anions collected on the filters. Methods to control contamination and interfering side reactions are described.

Otterson, D. A.↗

Spacelab 3 mission

Spacelab-3 (SL-3) was the first microgravity mission of extended duration involving crew interaction with animal experiments. This interaction involved sharing the Spacelab environmental system, changing animal food, and changing animal waste trays by the crew. Extensive microbial testing was conducted on the animal specimens and crew and on their ground and flight facilities during all phases of the mission to determine the potential for cross contamination. Macroparticulate sampling was attempted but was unsuccessful due to the unforseen particulate contamination occurring during the flight. Particulate debris of varying size (250 micron to several inches) and composition was recovered post flight from the Spacelab floor, end cones, overhead areas, avionics fan filter, cabin fan filters, tunnel adaptor, and from the crew module. These data are discussed along with solutions, which were implemented, for particulate and microbial containment for future flight facilities.

Dalton, Bonnie P.↗

Investigation of the influence of the zeta-potential on the filtration rate in the presence of collectors

The value of the zeta-potential does not have an explicit effect, which is expressed by a simple math correlation, on filtration rate when a solution of the tested collector is filtered through a cake prepared under standard conditions from the examined particulate material. The zeta-potential measurements and filtration tests were carried out on silica and galena with solutions contg. a cationic container ANP and Et xanthane, resp. at PH = 6.5, varying concentration of the agent (0-2500 g/ton), and under a vacuum of 100 to 600 mm Hg.

Provirnina, E. V.↗

Air Sampling Filter

General Metal Works' Accu-Vol is a high-volume air sampling system used by many government agencies to monitor air quality for pollution control purposes. Procedure prevents possible test-invalidating contamination from materials other than particulate pollutants, caused by manual handling or penetration of windblown matter during transit, a cassette was developed in which the filter is sealed within a metal frame and protected in transit by a snap-on aluminum cover, thus handled only under clean conditions in the laboratory.

Source record↗

Processing of combined domestic bath and laundry waste waters for reuse as commode flushing water

An experimental investigation of processes and system configurations for reclaiming combined bath and laundry waste waters for reuse as commode flush water was conducted. A 90-min recycle flow was effective in removing particulates and in improving other physical characteristics to the extent that the filtered water was subjectively acceptable for reuse. The addition of a charcoal filter resulted in noticeable improvements in color, turbidity, and suds elimination. Heating and chlorination of the waste waters were investigated for reducing total organism counts and eliminating coliform organisms. A temperature of 335.9 K (145 F) for 30 min and chlorine concentrations of 20 mg/l in the collection tank followed by 10 mg/l in the storage tank were determined to be adequate for this purpose. Water volume relationships and energy-use rates for the waste water reuse systems are also discussed.

Hypes, W. D.↗