Search NASA⌕ Search

SEARCH · Search NASA

Results for “PIV”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Blowing Flap Experiment: PIV Measurements

PIV measurements of the flow in the region of a flap side edge are presented for several flap configurations. The test model is a NACA 63(sub 2)-215 Hicks Mod-B main element airfoil with a half-span Fowler flap. Air is blown from small slots located along the flap side edge on either the top, bottom or side surfaces. The test set up is described and flow measurements for a baseline and three blowing flap configurations are presented. The effects that the flap tip jets have on the structure of the flap side edge flow are discussed for each of the flap configurations tested. The results indicate that blowing air from a slot located along the top surface of the flap greatly weakened the top vortex system and pushed it further off the top surface. Blowing from the bottom flap surface kept the strong side vortex further outboard while blowing from the side surface only strengthened the flap vortex system. It is concluded that blowing from the top or bottom surfaces of the flap may lead to a reduction of flap side edge noise.

Hutcheson, Florence V.↗

PIV Measurements on a Blowing Flap

PIV measurements of the flow in the region of a flap side edge are presented for several blowing flap configurations. The test model is a NACA 63(sub 2)-215 Hicks Mod-B main-element airfoil with a half-span Fowler flap. Air is blown from small slots located along the flap side edge on either the top, bottom or side surfaces. The test set up is described and flow measurements for a baseline and three blowing flap configurations are presented. The effects that the flap tip jets have on the structure of the flap side edge flow are discussed for each of the flap configurations tested. The results indicate that blowing air from a slot located along the top surface of the flap greatly weakened the top vortex system and pushed it further off the top surface. Blowing from the bottom flap surface kept the strong side vortex further outboard while blowing from the side surface only strengthened the vortex system or accelerated the merging of the side vortex to the flap top surface. It is concluded that blowing from the top or bottom surfaces of the flap may lead to a reduction of flap side edge noise.

Hutcheson, Florence V.↗

Systematic Errors in Stereo PIV When Imaging through a Glass Window

This document assesses the magnitude of velocity measurement errors that may arise when performing stereo particle image velocimetry (PIV) with cameras viewing through thick, refractive window and where the calibration is performed in one plane only. The effect of the window is to introduce a refractive error that increases with window thickness and the camera angle of incidence. The calibration should be performed while viewing through the test section window, otherwise a potentially significant error may be introduced that affects each velocity component differently. However, even when the calibration is performed correctly, another error may arise during the stereo reconstruction if the perspective angle determined for each camera does not account for the displacement of the light rays as they refract through the thick window. Care should be exercised when applying in a single-plane calibration since certain implicit assumptions may in fact require conditions that are extremely difficult to meet in a practical laboratory environment. It is suggested that the effort expended to ensure this accuracy may be better expended in performing a more lengthy volumetric calibration procedure, which does not rely upon the assumptions implicit in the single plane method and avoids the need for the perspective angle to be calculated.

Green, Richard↗

Application of Time-resolved PIV to Supersonic Hot Jets

This presentation lays out the ground-breaking work at bringing high-speed (25kHz) particle image velocimetry (PIV) to bear on measurements of noise-producing turbulence in hot jets. The work is still in progress in that the tremendous amount of data obtained are still be analyzed, but the method has been validated and initial results of interest to jet noise modeling have been obtained. After a brief demonstration of the validation process used on the data, results are shown for hot jets at different temperatures and Mach numbers. Comparisons of first order statistics show the relative indifference of the turbulence to the presence of shocks and independence to jet temperature. What does come out is that when the shock-containing jets are in a screech mode the turbulence is highly elevated, showing the importance of removing screech phenomena from model-scale jets before applying findings to full-scale aircraft which typically do not contain shocks.

Bridges, James↗

Development of a Large Field-of-View PIV System for Rotorcraft Testing in the 14- x 22-Foot Subsonic Tunnel

A Large Field-of-View Particle Image Velocimetry (LFPIV) system has been developed for rotor wake diagnostics in the 14-by 22-Foot Subsonic Tunnel. The system has been used to measure three components of velocity in a plane as large as 1.524 meters by 0.914 meters in both forward flight and hover tests. Overall, the system performance has exceeded design expectations in terms of accuracy and efficiency. Measurements synchronized with the rotor position during forward flight and hover tests have shown that the system is able to capture the complex interaction of the body and rotor wakes as well as basic details of the blade tip vortex at several wake ages. Measurements obtained with traditional techniques such as multi-hole pressure probes, Laser Doppler Velocimetry (LDV), and 2D Particle Image Velocimetry (PIV) show good agreement with LFPIV measurements.

Jenkins, Luther N.↗

Landing Gear Components Noise Study - PIV and Hot-Wire Measurements

PIV and hot-wire measurements of the wake flow from rods and bars are presented. The test models include rods of different diameters and cross sections and a rod juxtaposed to a plate. The latter is representative of the latch door that is attached to an aircraft landing gear when the gear is deployed, while the single and multiple rod configurations tested are representative of some of the various struts and cables configuration present on an aircraft landing gear. The test set up is described and the flow measurements are presented. The effect of model surface treatment and freestream turbulence on the spanwise coherence of the vortex shedding is studied for several rod and bar configurations.

Hutcheson, Florence V.↗

Simultaneous, Unsteady PIV and Photogrammetry Measurements of a Tension-Cone Decelerator in Subsonic Flow

This paper describes simultaneous, synchronized, high-frequency measurements of both unsteady flow in the wake of a tension-cone decelerator in subsonic flow (by PIV) and the unsteady shape of the decelerator (by photogrammetry). The purpose of these measurements was to develop the test techniques necessary to validate numerical methods for computing fluid-structure interactions of flexible decelerators. A critical need for this effort is to map fabric surfaces that have buckled or wrinkled so that code developers can accurately represent them. This paper describes a new photogrammetric technique that performs this measurement. The work was done in support of the Entry, Descent, and Landing discipline within the Supersonics Project of NASA s Fundamental Aeronautics Program.

Schairer, Edward T.↗

PIV Measurements of Chevrons on F400 Tactical Aircraft Nozzle Model

Previous talks at this meeting have covered our collaborative work on high-energy jets such as present in tactical aircraft (those with supersonic plumes). The emphasis of this work is improving our understanding of flow physics and our prediction tools. In this presentation we will discuss recent flow diagnostics acquired using Particle Image Velocimetry (PIV) made on an underexpanded shocked jet plume from a tactical aircraft nozzle. In this presentation we show cross-sectional and streamwise cuts of both mean and turbulent velocities of an F404 engine nozzle with various chevron designs applied. The impact of chevron penetration, length, and width are documented. The impact of the parameters is generally nonlinear in measures considered here, a surprising result given the relatively smooth behavior of the noise to variations in these chevron parameters.

Bridges, James↗

PIV Measurements of the CEV Hot Abort Motor Plume for CFD Validation

NASA s next manned launch platform for missions to the moon and Mars are the Orion and Ares systems. Many critical aspects of the launch system performance are being verified using computational fluid dynamics (CFD) predictions. The Orion Launch Abort Vehicle (LAV) consists of a tower mounted tractor rocket tasked with carrying the Crew Module (CM) safely away from the launch vehicle in the event of a catastrophic failure during the vehicle s ascent. Some of the predictions involving the launch abort system flow fields produced conflicting results, which required further investigation through ground test experiments. Ground tests were performed to acquire data from a hot supersonic jet in cross-flow for the purpose of validating CFD turbulence modeling relevant to the Orion Launch Abort Vehicle (LAV). Both 2-component axial plane Particle Image Velocimetry (PIV) and 3-component cross-stream Stereo Particle Image Velocimetry (SPIV) measurements were obtained on a model of an Abort Motor (AM). Actual flight conditions could not be simulated on the ground, so the highest temperature and pressure conditions that could be safely used in the test facility (nozzle pressure ratio 28.5 and a nozzle temperature ratio of 3) were used for the validation tests. These conditions are significantly different from those of the flight vehicle, but were sufficiently high enough to begin addressing turbulence modeling issues that predicated the need for the validation tests.

Wernet, Mark↗

A PIV Study of Slotted Air Injection for Jet Noise Reduction

Results from acoustic and Particle Image Velocimetry (PIV) measurements are presented for single and dual-stream jets with fluidic injection on the core stream. The fluidic injection nozzles delivered air to the jet through slots on the interior of the nozzle at the nozzle trailing edge. The investigations include subsonic and supersonic jet conditions. Reductions in broadband shock noise and low frequency mixing noise were obtained with the introduction of fluidic injection on single stream jets. Fluidic injection was found to eliminate shock cells, increase jet mixing, and reduce turbulent kinetic energy levels near the end of the potential core. For dual-stream subsonic jets, the introduction of fluidic injection reduced low frequency noise in the peak jet noise direction and enhanced jet mixing. For dual-stream jets with supersonic fan streams and subsonic core streams, the introduction of fluidic injection in the core stream impacted the jet shock cell structure but had little effect on mixing between the core and fan streams.

Henderson, Brenda S.↗

PIV Measurements of Full-Scale UH-60A Tip Vortices

The following presentation will give a description on experiments like installation, PIV measurements, and test conditions. It will also be giving the status of data processing, as well as, preliminary results. In addition, plans and present papers will also be discussed.

Yamauchi, Gloria K.↗

PIV Measurements of a Low-noise Top-mounted Propulsion Installation for a Supersonic Airliner

A model-scale exhaust system was tested to validate low-noise propulsion concepts and noise prediction methods. The tests involved far-field acoustics, phased array, and particle image velocimetry (PIV). This paper covers the particle image velocimetry portion. Data was acquired at NASA Glenn's Aero-Acoustic Propulsion Lab for a series of nozzles with different chevron designs, both uninstalled and installed on a representative aircraft planform. The impact of the various chevron treatments on the turbulent velocity field was documented, along with the impact of the pylon and planform. When correlated with far-field acoustic measurements and phased array measurements, reported in companion papers, the explanation of acoustic benefits from top-mounted propulsion is clear as is the path toward optimization of the concept.

Propulsion Airframe Integration↗

Stability Analysis of the Flow over a Swept Forward-Facing Step using PIV Base Flowsin a Non-Orthogonal Coordinate System

Understanding the flow of a crossflow-vortex-dominated boundary layer over a forward-facing step excrescence is necessary in order to mitigate an early transition scenario on the wings and tail of commercial aircraft. By performing BiGlobal stability analysis on the flowfield measured with high-resolution, stereographic Particle Image Velocimetry (PIV), previous work has shown that a family of unstable disturbances exists in the direct downstream vicinity of a supercritical, forward-facing step. The goal of the present paper is to improve the previously used stability approach on two fronts: 1) the stability problem is formulated in a non-orthogonal coordinate system and 2) the contribution of the out-of-plane base-flow derivatives is accounted for locally. The resulting eigen solutions feature significantly stronger growth rates and eigenfunctions that are localized above regions of reverse flow. The changes in the problem formulation furthermore establish a significant improvement in the comparison of the stability solutions with the results from the Spectral Proper Orthogonal Decomposition (SPOD) of a time-resolved measurement of the perturbation content. A large destabilizing effect by the out-of-plane base-flow derivatives is determined to be justified, despite the assumption that these derivatives are small, because the effect can be reconstructed upon using an eigenvalue-correction formula that assumes the responsible terms are infinitesimally small. The unstable perturbation mechanisms are demonstrated to have a convective nature by assessing the relation between the frequency and the out-of-plane wavenumber, which indicates that their group speed does not approach zero. The last 2 facts, that 1) the perturbations are convective and 2) that the out-of-plane base-flow-derivative terms are small, remove any qualitative suspicions that the perturbation problem is not conducive to parabolization. This opens the path to analyzing this problem with a plane-marching approach.

Boundary- Layer Transition↗

Multi-spatio-temporal scales PIV in a turbulent buoyant jet discharging in a linearly stratified environment

Time-resolved particle image velocimetry is implemented with a camera array and several laser sheets; this results in a multi-spatio-temporal scale system that is modular and flexible. The setup is optimized to capture global flow features, while locally resolving in space and time near the Kolmogorov scale. The apparatus relies extensively on machine vision CMOS cameras; they are inexpensive and stream to computer hard drive with virtually continuous time-resolved records (up to one hour for the current system). This leads to statistically converged data and also helps in minimizing down time between experimental runs. Details of the implementation and design of experiment are reported. The system instruments a vertical buoyant jet discharging in a linearly stratified environment. Refractive index matched aqueous solutions enable precise optical deployment. The density difference is 3% and the fluids have similar dynamic viscosity. The jet Reynolds number is 2.00 x 10 4 and is above the mixing transition. Such flows are typically challenging to instrument and few velocity field data are available to date. The velocity statistics are reported as well as first insights gained from the campaign.

42 ENGINEERING↗

Tidal Current Cross-flow Turbine Wake ADV and PIV Data

Measurements in the wake of a high-solidity cross-flow turbine in a laboratory flume obtained using Acoustic Doppler Velocimetry and Particle Image Velocimetry for the purposes of characterizing the turbine wake and comparing the methods.

16 TIDAL AND WAVE POWER↗

Two-phase flow structure in dual discharges - Stereo PIV measurements

The discharge of two-phase flow from a stratified region through single or multiple branches is an important process in many industrial applications including the pumping of fluid from storage tanks, shell-and-tube heat exchangers, and the fluid flow through header to the cooling channels, feeder's tube, of nuclear reactors during loss-of-coolant accidents (LOCA). Knowledge of the flow phenomena involved along with the quality and mass flow rate of the discharging stream(s) is necessary to adequately predict the different phenomena associated with the process. Stereoscopic Particle Image Velocimetry (SPIV) was used to provide detailed measurements of the flow patterns involving distributions of mean velocity, vorticity field, and flow structure. The experimental investigation was carried out to simulate two-phase discharge from a stratified region through branches located on a quarter-circular wall configuration exposed to a stratified gas-liquid environment. The quarter-circular test section is in close dimensional resemblance with that of a CANDU header-feeder system, with branches mounted at orientation angles of zero, 45 and 90 degrees from the horizontal. The experimental data for the phase development (mean velocity, flow structure, etc.) was collected during dual discharge through the horizontal branch and the 45 or 90 branch from an air-water stratified region over two selected Froude numbers in the horizontal branch while maintaining the Froude number in the other branch constant. These measurements were used to describe the effect of outlet flow conditions on phase redistribution in headers and understand the entrainment phenomena. (author)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗