Search NASA⌕ Search

SEARCH · Search NASA

Results for “PLASMA DIAGNOSTICS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Observations of xenon spectra on the EAST x-ray crystal spectrometer for high-temperature plasma diagnostics

The Xe 44+ 2.7203 Å line, which has been proposed as one of the diagnostic lines for the x-ray imaging crystal spectrometer on ITER, is observed on the EAST tokamak together with its several satellite lines. The observations are made under high electron temperature (T e ) conditions (core T e > 5 keV). Most of the observed xenon lines are identified by comparing the experiment results with the atomic simulation results. The first ion temperature measurements made by the xenon spectra on EAST are also reported in this article. These xenon spectra observations contribute to the justification for using xenon as the diagnostic impurity in x-ray crystal spectrometers in future reactor-scale high-temperature plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

One-dimensional space resolving flat-field holographic grating soft x-ray framing camera spectrograph for laser plasma diagnostics

A 1D space resolving x-ray spectrum diagnostic system has been developed to study the radiation opacity of hot plasma on SG-II laser facility. The diagnostic system consists of a 2400 lines/mm flat-field holographic grating and a gated microchannel plate coupled with an optical CCD and covers the wavelength range of 5-50 A. The holographic grating was compared with a ruled one by measuring the emission spectra from a laser-produced molybdenum plasma. The results indicate that the holographic grating possesses better sensitivity than the ruled grating having nearly similar spectral resolution. The spectrograph has been used in radiative opacity measurement of Fe plasma. Simultaneous measurements of the backlight source and the transmission spectrum in appointed time range in one shot have been accomplished successfully with the holographic grating spectrometer. The 2p-3d transition absorption of Fe plasma near 15.5A in has been observed clearly.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Plasma Diagnostics by Antenna Impedance Measurements

The impedance of an electrically short antenna immersed in a plasma provides an excellent in situ diagnostic tool for electron density and other plasma parameters. By electrically short we mean that the wavelength of the free-space electromagnetic wave that would be excited at the driving frequency is much longer than the physical size of the antenna. Probes using this impedance technique have had a long history with sounding rockets and satellites, stretching back to the early 1960s. This active technique could provide information on composition and temperature of plasmas for comet or planetary missions. Advantages of the impedance probe technique are discussed and two classes of instruments built and flown by SDL-USU for determining electron density (the capacitance and plasma frequency probes) are described.

Swenson, C. M.↗

PROMINENCE PLASMA DIAGNOSTICS THROUGH EXTREME-ULTRAVIOLET ABSORPTION

In this paper, we introduce a new diagnostic technique that uses EUV and UV absorption to determine the electron temperature and column emission measure, as well as the He/H relative abundance of the absorbing plasma. If a realistic assumption on the geometry of the latter can be made and a spectral code such as CHIANTI is used, then this technique can also yield the absorbing plasma hydrogen and electron density. This technique capitalizes on the absorption properties of hydrogen and helium at different wavelength ranges and temperature regimes. Several cases where this technique can be successfully applied are described. This technique works best when the absorbing plasma is hotter than 15,000 K. We demonstrate this technique on AIA observations of plasma absorption during a coronal mass ejection eruption. This technique can be easily applied to existing observations of prominences and cold plasmas in the Sun from almost all space missions devoted to the study of the solar atmosphere, which we list.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Plasma diagnostics in spherical tokamaks with silicon charged-particle detectors

Detection of charged fusion products, such as protons and tritons resulting from D(d, p) t reactions, can be used to determine the position and time dependent fusion reaction rate profile in spherical tokamak plasmas with neutral beam heating. We have developed a prototype instrument consisting of 6 ion-implanted-silicon surface barrier detectors combined with collimators in such a way that each detector can accept 3 MeV protons and 1 MeV tritons and thus provides a curved view across the plasma cross section. The combination of the results from all six detectors will provide information on the spatial distribution of the fusion reaction rate. The expected time resolution of about 1 ms makes it possible to study changes in the reaction rate due to slow variations in the neutral beam density profile, as well as rapid changes resulting from MHD instabilities. Details of the new instrument, its data acquisition system, simulation results, and electrical noise testing results are discussed in this paper. First experimental data are expected to be taken during the current experimental campaign at NSTX-U.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Plasma diagnostics from intensities of resonance line series of He-like ions

The possibility of using the relative intensities of the 1snp{sup 1}P{sub 1}–1s{sup 21}S0 transitions with n = 3–6 in He-like multicharged ions to diagnose plasma in a nonstationary ionization state is considered. The calculations performed for F VIII ions show that, at electron temperatures of T{sub e} = 10–100 eV, the intensity ratios are sensitive to the plasma electron density in the range of N{sub e} = 10{sup 16}–10{sup 20} cm{sup –3}. The universal calculated dependences can be used to diagnose various kinds of recombining or ionizing plasmas containing such ions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Thruster Plume Plasma Diagnostics: A Ground Chamber Experiment for a 2-Kilowatt Arcjet

Although detailed near field (0 to 3 cm) information regarding the exhaust plume of a two kilowatt arc jet is available (refs. 1 to 6), there is virtually little or no information (outside of theoretical extrapolations) available concerning the far field (2.6 to 6.1 m). Furthermore real information about the plasma at distances between (3 to 6 m) is of critical importance to high technology satellite companies in understanding the effect of arc jet plume exhausts on space based power systems. It is therefore of utmost importance that one understands the exact nature of the interaction between the arc jet plume, the spacecraft power system and the surrounding electrical plasma environment. A good first step in understanding the nature of the interactions lies in making the needed plume parameter measurements in the far field. All diagnostic measurements are performed inside a large vacuum system (12 m diameter by 18 m high) with a full scale arc jet and solar array panel in the required flight configuration geometry. Thus, necessary information regarding the plume plasma parameters in the far field is obtained. Measurements of the floating potential, the plasma potential, the electron temperature, number density, density distribution, debye length, and plasma frequency are obtained at various locations about the array (at vertical distances from the arc jet nozzle: 2.6, 2.7, 2.8, 3.2, 3.6, 4.0, 4.9, 5.0, 5.4, 5.75, and 6.14 m). Plasma diagnostic parameters are measured for both the floating and grounded configurations of the arc jet anode and array. Spectroscopic optical measurements are then acquired in close proximity to the nozzle, and contamination measurements are made in the vicinity of the array utilizing a mass spectrometer and two Quartz Crystal Microbalances (QCM's).

Galofaro, Joel T.↗

Upgrades of imaging x-ray crystal spectrometers for high-resolution and high-temperature plasma diagnostics on EAST

Upgrade of the imaging X-ray crystal spectrometers continues in order to fulfill the high-performance diagnostics requirements on EAST. For the tangential spectrometer, a new large pixelated two-dimensional detector was deployed on tokamaks for time-resolved X-ray imaging. This vacuum-compatible detector has an area of 83.8 × 325.3 mm{sup 2}, a framing rate over 150 Hz, and water-cooling capability for long-pulse discharges. To effectively extend the temperature limit, a double-crystal assembly was designed to replace the previous single crystals for He-like argon line measurement. The tangential spectrometer employed two crystal slices attached to a common substrate and part of He- and H-like Ar spectra could be recorded on the same detector when crystals were chosen to have similar Bragg angles. This setup cannot only extend the measurable Te up to 10 keV in the core region, but also extend the spatial coverage since He-like argon ions will be present in the outer plasma region. Similarly, crystal slices for He-like iron and argon spectra were adopted on the poloidal spectrometer. Wavelength calibration for absolute rotation velocity measurement will be studied using cadmium characteristic L-shell X-ray lines excited by plasma radiation. A Cd foil is placed before the crystal and can be inserted and retracted for in situ wavelength calibration. The Geant4 code was used to estimate X-ray fluorescence yield and optimize the thickness of the foil.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Material Dependence Of The contaminating Film Growth On In-Vessel Mirrors For Plasma Diagnostics

In this paper, the results of postmortem analysis of mirror samples exposed for the one-year campaign inside the Tore Supra (TS) tokamak and for shorter time inside the TCV tokamak are presented, together with results of laboratory mirror experiments. In TS, although all mirrors were eroded, the observed erosion rates do not correspond with the published sputtering yields. In TCV the thickness of the carbon-based film deposited on the mirror samples was found to depend on the mirror material, being several times higher on Si than on W and Mo substrates. An attempt is made to attract for explanation of results the difference in stickiness of carbon to SS and to Cu surfaces. The laboratory experiments qualitatively support such explanation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Plasma Diagnostic Calibration and Characterizations with High Energy X-rays

National Security Technologies’ High Energy X-ray (HEX) Facility is unique in the U.S. Department of Energy complex. The HEX provides fluorescent X-rays of 5 keV to 100 keV with fluence of 10^5–10^6 photons/cm^2/second at the desired line energy. Low energy lines can be filtered, and both filters and fluorescers can be changed rapidly. We present results of calibrating image plates (sensitivity and modulation transfer function), a Bremsstrahlung spectrometer (stacked filters and image plates), and the National Ignition Facility’s Filter- Fluorescer Experiment (FFLEX) high energy X-ray spectrometer. We also show results of a scintillator light yield and alignment study for a neutron imaging system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗