Search NASA⌕ Search

SEARCH · Search NASA

Results for “PLATES, FLAT - STIFFENED”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Experimental investigation of effects of jet decay rate on jet-induced pressures on a flat plate: Tabulated data

Tabular data are presented for an experimental study of the effects of jet decay rate on the jet-induced pressure distribution on a flat plate for a single jet issuing at right angle to the flat plate into a uniform crossflow. The data are presented in four sections: (1) presents the static nozzle calibration data; (2) lists the plate surface static pressure data and integrated loads; (3) lists the jet centerline trajectory data; and (4) lists the centerline dynamic pressure data.

Kuhlman, J. M.↗

Comparison under a simulated sun of two black-nickel-coated flat-plate solar collectors with a nonselective black-paint-coated collector

A performance evaluation was made of two, black nickel coated, flat plate solar collectors. Collector performance was determined under a simulated sun for a wide range of inlet temperatures, including the temperature required for solar powered absorption air conditioning. For a basis of comparison a performance test was made on a traditional, two glass, nonselective, black paint coated, flat plate collector. Performance curves and performance parameters are presented to point out the importance of the design variables which determine an efficient collector. A black nickel coated collector was found to be a good performer at the conditions expected for solar powered absorption air conditioning. This collector attained a thermal efficiency of 50 percent at an inlet temperature of 366 K (200 F) and an incident flux of 946 watts/sq m (300 Btu/hr-sq ft).

Simon, F. F.↗

Rapid Fabrication of Flat Plate Cavity Phosphor Thermography Test Models for Shuttle Return-to-Flight Aero-Heating

Methods, materials and equipment are documented for fabricating flat plate test models at NASA Langley Research Center for Shuttle return-to-flight aeroheating experiments simulating open and closed cavity interactions in Langley s hypersonic 20-Inch Mach 6 air wind tunnel. Approximately 96 silica ceramic flat plate cavity phosphor thermography test models have been fabricated using these methods. On one model, an additional slot is machined through the back of the plate and into the cavity and vented into an evacuated plenum chamber to simulate a further opening in the cavity. After sintering ceramic to 2150 F, and mounting support hardware, a ceramic-based two-color thermographic phosphor coating is applied for global temperature and heat transfer measurements, with fiducial markings for image registration.

Buck, Gregory M.↗

A generalized correlation of experimental flat-plate collector performance

A generalized correlation of flat-plate collector performance obtained by outdoor and indoor test methods is presented. This correlation shows that the indoor (simulator) test approach is a special case of the general situation of variable solar conditions. The important feature of the generalized correlation is that it permits a separation of the solar variables (flux, incident angle, etc.) which affect collector performance from the collector parameters (absorptance, transmittance, heat loss, etc.) which also affect collector performance and which are uniquely part of a given collector design. The correlation permits an evaluation of the relative merits of using instantaneous, hourly and daily collector efficiencies in obtaining a good collector correlation. The question of the transient behavior outdoors of a collector is an important part of determining whether to use instantaneous, hourly or daily efficiency values in a correlation approach. Correlation of the experimental performance of collectors allows the following: (1) comparisons of different collector designs, (2) collector performance prediction under conditions that differ from the conditions of the test program, and (3) monitoring performance degradation effects.

Simon, F. F.↗

Characterization of the electrical output of flat-plate photovoltaic arrays

The electric output of flat-plate photovoltaic arrays changes constantly, due primarily to changes in cell temperature and irradiance level. As a result, array loads such as direct-current to alternating-current power conditioners must be able to accommodate widely varying input levels, while maintaining operation at or near the array maximum power point.The results of an extensive computer simulation study that was used to define the parameters necessary for the systematic design of array/power-conditioner interfaces are presented as normalized ratios of power-conditioner parameters to array parameters, to make the results universally applicable to a wide variety of system sizes, sites, and operating modes. The advantages of maximum power tracking and a technique for computing average annual power-conditioner efficiency are discussed.

Gonzalez, C. C.↗

Flat-plate solar array progress and plans

The Flat-Plate Solar Array Project (FSA), sponsored by the U.S. Department of Energy (DOE) and managed by the Jet Propulsion Laboratory (JPL), has achieved progress in a broad range of technical activities since that reported at the Fourth European Communities Conference. A particularly important analysis has been completed recently which confirms the adoption into practice by the U.S. Photovoltaic (PV Industry, of all the low-cost module technology elements proposed at the 16th Project Integration Meeting for a $2.80/Wp (1980 U.S. Dollars) design approach in the fall of 1980. This work presents along with a projection, using the same techniques, for what is believed to be a very credible ribbon-based module design for less that $0.55/Wp (1980 U.S. Dollars). Other areas to be reported upon include low-cost Si feedstock refinement; ribbon growth; process sequence development for cells; environmental isolation; engineering science investigations; and module testing progress.

Callaghan, W. T.↗

The solution of the laminar-boundary-layer equation for the flat plate for velocity and temperature fields for variable physical properties and for the diffusion field at high concentration

In connection with Pohlhausen's solution for the temperature field on the flat plate, a series of formulas were indicated by means of which the velocity and temperature field for variable physical characteristics can be computed by an integral equation and an iteration method based on it. With it, the following cases were solved: On the assumption that the viscosity simply varies with the temperature while the other fluid properties remain constant, the velocity and temperature field on the heated and cooled plate, respectively, was computed at the Prandtl numbers 12.5 and 100 (viscous fluids). A closer study of these two cases resulted in general relations: The calculations for a gas of Pr number 0.7 (air) were conducted on the assumption that all fluid properties vary with the temperature, and the velocities are low enough for the heat of friction to be discounted. The result was a thickening of the boundary layers, but no appreciable modification in shearing stress or heat-transfer coefficient.

BOUNDARY LAYER, LAMINAR - PLATES, FLAT↗

Dynamic ground effects on a two-dimensional flat plate

The effect of time-variant vortex shedding is simulated by a sequence of discrete vortices convecting downstream in the wake of a two-dimensional flat plate whose lifting condition is modeled by means of the quasi-vortex lattice method. The boundary condition of this problem is specified in such a way that the tangency condition on the surface of the flat plate is satisfied; the boundary condition also takes into account the effect of airfoil motion relative to the ground. Significant lift changes are shown to occur, due to the dynamic ground effect, that are crucial in aircraft takeoff and landing transitions.

Chen, Y.-S.↗

On the large-scale structure of the turbulent wake of a flat plate

A simple heat-tagging technique was used to isolate and analyze the large-scale coherent structures present in the two-dimensional wake of a flat plate. The results indicate the presence of these coherent structures even at 250 momentum thicknesses downstream of the trailing edge. These structures have a vortexlike topology and carry a significant amount of the total shear stress. The present results for the flat-plate wake seem to be in general agreement with those that have been obtained in cylinder wakes by other comtemporary investigators using more complex techniques of eduction and signal enhancement.

Jovic, S.↗

High performance flat plate solar collector

The potential use of porous construction is presented to achieve efficient heat removal from a power producing solid and is applied to solar air heaters. Analytical solutions are given for the temperature distribution within a gas-cooled porous flat plate having its surface exposed to the sun's energy. The extracted thermal energy is calculated for two different types of plate transparency. Results show the great improvement in performance obtained with porous flat plate collectors as compared with analogous nonporous types.

Lansing, F. L.↗

An Analysis of CFD and Flat Plate Predictions of Friction Drag for the TCA W/B at Supersonic Cruise

This paper presents results of a study which attempted to provide some understanding of the relationship between skin friction drag estimates produced by flat plate methods and those produced by Navier-Stokes computations. A brief introduction is followed by analysis, including a flat plate grid study, analysis of the wing flow, an analysis of the fuselage flow. Other results of interest are then presented, including turbulence model sensitivities, and brief analysis of other configurations.

Lawrence, Scott L.↗

Hydrodynamic characteristics over a range of speeds up to 80 feet per second of a rectangular modified flat plate having an aspect ratio of 0.25 and operating at several depths of submersion

Results of an investigation of the hydrodynamic characteristics over an extended speed range of a rectangular modified flat plate having an aspect ratio of 0.25 and operating at several depths of submersion are presented. Comparisons between these data and data over a lower speed range on a similar aspect-ratio-0.25 flat plate but having one-half the thickness are presented. These comparisons show no significant differences at the low speeds. At high speeds and high angles of attack, where extensive cavitation was present, the lift coefficients were lower than would have been indicated by the results of the previous investigations and the present investigation at the lower angles of attack. A brief discussion and comparison of ventilation are presented which shows two types of planing bubble formation and the effect of increasing the thickness of the model on the ventilation boundary.

REYNOLDS NUMBER EFFECTS - COMPLETE WINGS↗