Search NASA⌕ Search

SEARCH · Search NASA

Results for “PLIF”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Towards Simultaneous Multi-Parameter Measurements Using Burst-Mode Frequency-Scanning Planar Laser-Induced Fluorescence

While planar laser-induced fluorescence (PLIF) can provide valuable flow visualization, there are many challenges in extracting quantitative measurements from the fluorescence intensity. To overcome the multi-parameter dependence of the signal intensity, frequency scanning planar laser-induced fluorescence (FS-PLIF) provides the potential for 2D temperature, pressure, and velocity measurements by spectrally resolving the excitation spectrum of one or more fluorescence transitions to extract the Doppler shift, Doppler- and collisional-broadening of absorption lines, and the relative signal intensities of multiple transitions. This work aims to characterize a burst-mode FS-PLIF system consisting of a Spectral Energies, LLC burst-mode laser coupled with a Spectral Energies, LLC optical parametric oscillator using nitric oxide (NO) static pressure cell measurements. The effect of the OPO cavity on intensity fluctuations during frequency-scanning is investigated. A NO PLIF model is implemented to investigate the feasibility of property measurements using single- and two-NO-line scans.

burst-mode laser↗

Definition, dimensionality, and resolution effects on the flame surface area at high Karlovitz number [Turbulent flame surface area at high Karlovitz number]

Direct numerical simulations of turbulent premixed flames are used to assess differences in flame surface area between recent experimental and numerical studies at high Karlovitz number. Simulations performed at varying Karlovitz number and integral length scale reveal a strong correlation between the turbulent flame speed and the flame surface area. Experimental measurements from the literature do not always exhibit such strong correlation. Potential discrepanices between the experimental and numerical methodologies are identified and quantified. The experimental PLIF images are two-dimensional and their resolution is limited by that of the PLIF system. The implication of using two-dimensional isocontours is assessed by post-processing the simulation data. It is shown that the surface computed from the three-dimensional field is always greater than that computed from the two-dimensional images. Furthermore, the effect of the PLIF resolution is assessed by filtering the simulated data. Significant differences between the unfiltered and filtered surface areas are observed at a filter width representative of the PLIF resolution.

02 PETROLEUM↗

Characterization of Flashback and Flame-Holding in a Jet-in-Crossflow Mixing Configuration With Methane–Hydrogen Fuel Blends

An approach that combines experimental and numerical analyses has been implemented to characterize the fundamentals of flashback events and flame-holding phenomena during high-hydrogen combustion in a jet-in-crossflow (JICF) configuration. Such flame dynamics are visualized experimentally using nanosecond (ns)-based hydroxyl planar laser-induced fluorescence (OH-PLIF) and chemiluminescence diagnostics techniques. The JICF burner has an optically accessible premixing tube allowing the optical diagnostics. The testing was conducted for varied premixer velocities (V) and equivalence ratio (ϕ) for 90–100% (H 2 , by mole) H 2 /CH 4 reactant mixtures at atmospheric temperature and pressure conditions. Two distinct flashback events were identified – conventional rich flashback and lean flashback, recorded while increasing ϕ and decreasing ϕ, respectively. The cause of lean flashback was attributed to lower momentum flux ratio which bends the jet sharply, closer toward the injection plane. The mean OH-PLIF images characterized the flame-holding behavior, where the flame was found to be stabilized on the leeward side only or on both windward and leeward sides as a lifted flame near the fuel port. A large eddy simulation (LES) with detailed chemistry combustion modeling approach was implemented along with an OH* submechanism, and it showed qualitative agreement with the integrated line-of-sight chemiluminescence results as well as the planar OH-PLIF measurements.

chemiluminescence diagnostic↗

Nitric Oxide Planar Laser Induced Fluorescence Rotational Thermometry Characterization of A Hypersonic Boundary Layer

Nitric oxide (NO) planar laser-induced fluorescence (PLIF) was performed to determine rotational temperature profiles and fluctuations within a hypersonic boundary layer above the surface of a 2.75° half-angle wedge. The experiments were performed in the Texas A&M University Actively Controlled Expansion (ACE) hypersonic blow-down wind tunnel at Mach = 5.7 and 𝑅𝑒 = 6 × 10 6 /m. The NO was introduced to the flow in the settling chamber of the ACE tunnel and probed using two laser sheets near 226 nm. The resulting NO PLIF fluorescence signal was acquired using in-house software, which simultaneously recorded tunnel conditions. After a Fast Fourier Transform (FFT) blurring and statistical treatment was performed, the preshock temperature was evaluated to be 58 ± 2 K (3.5%), while the turbulent boundary layer temperature near the wall was found to be 350 K with fluctuations on the order of ±25 K (7%). The relative temperature fluctuations were determined to be 3 − 5% in the freestream and peaked at 33% in the turbulent boundary layer. The advantages and disadvantages of seeding NO in the tunnel settling chamber for thermometric PLIF measurements are discussed.

Hypersonics↗

Review of planar laser-induced fluorescence measurements in the NASA Langley 31-Inch Mach 10 Air Tunnel

In 2003 a mobile planar laser-induced fluorescence (PLIF) system was constructed at NASA Langley Research Center to visualize and quantify high speed flow fields containing fluorescent species such as nitric oxide (NO). Thereafter, a series of test entries utilizing NO PLIF were conducted in the NASA Langley Research Center’s 31 Inch Mach 10 air wind tunnel, which is a hypersonic blowdown wind tunnel located in Hampton, Virginia. This paper briefly reviews laser-based measurements previously performed in hypersonic blowdown wind tunnel facilities and then details NO PLIF measurement campaigns performed at this facility in the 20 years to date. Measurements were performed to develop 2D and 3D visualization capabilities and quantitatively measure velocity and temperature. Applications described herein include historical models (e.g., Apollo, X-33 and X-43), flight vehicles under development at the time (e.g., Mars Science Lab (MSL), Orion, and LOFTID), as well as fundamental research (e.g., flat plates with and without discrete roughness).

PLIF↗

Turbulent nonpremixed cool flames: Experimental measurements, Direct Numerical Simulation, and manifold-based combustion modeling

Turbulence, low-temperature chemistry, and their interactions in the form of turbulent cool flames are critical to understanding and improving advanced engines. Design of such engines requires tractable simulations which in turn necessitate turbulent combustion models that can account for cool flames. While manifold-based turbulent combustion models are an attractive option for hot flames, their applicability to cool flames is not yet fully understood. This is partially due to the lack of turbulent cool flame experiments, which has made model validation difficult. This work addresses these points with a combined experimental and computational investigation of turbulent nonpremixed dimethyl ether cool flames. First, a Co-flow Axisymmetric Reactor-Assisted Turbulent (CARAT) burner is developed and tested. Turbulent cool flames are studied using the formaldehyde planar laser-induced fluorescence (PLIF), acetone PLIF, and planar Rayleigh scattering techniques. The acetone PLIF signals are converted into mixture fraction values, and measurements of time-averaged temperature are derived from the Rayleigh scattering signals by taking advantage of the similarities between cool flames and unburned mixtures. Second, a Direct Numerical Simulation (DNS) of the CARAT burner is conducted. The flame is shown to be sensitive to thermal boundary conditions such that the stabilization method is dependent on a 10 K change in inlet temperature. Comparisons of first- and second-order statistics of temperature, mixture fraction, and formaldehyde between the DNS and experiment show good agreement. The validity of manifold-based turbulent combustion models in turbulent cool flames is then explored by first studying the effective Lewis numbers in the flame using a local differential diffusion parameter analysis. Turbulent cool flames are shown to have effective unity Lewis number transport even at a much lower Reynolds number than typically required for hot flames. Good agreement is shown for temperature and formaldehyde between DNS conditional means and one-dimensional nonpremixed flame solutions. Additionally, the motion of the cool flame in mixture fraction space is shown to be well described by one-dimensional nonpremixed flame solutions. These points indicate that the fundamental physics of turbulent cool flames are analogous to turbulent hot flames, implying that the same reduced-order manifold-based modeling approaches utilized for turbulent hot flames can be utilized for turbulent cool flames.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterization of Flashback and Flame-Holding in a Jet-in-Crossflow Mixing Configuration with Methane-Hydrogen Fuel Blends

An approach that combines experimental and numerical analyses has been implemented to characterize the fundamentals of flashback events and flame-holding phenomena during high-hydrogen combustion in a jet-in-crossflow (JICF) configuration. Such flame dynamics are visualized experimentally using nanosecond (ns)-based hydroxyl planar laser-induced fluorescence (OH-PLIF) and chemiluminescence diagnostics techniques. The JICF burner has an optically accessible pre-mixing tube allowing the optical diagnostics. The testing was conducted for varied pre-mixer velocities (V) and equivalence ratio (ϕ) for 90%-100% (H2, by mole) H2/CH4 reactant mixtures at atmospheric temperature and pressure conditions. Two distinct flashback events were identified – conventional rich flashback and lean flashback, recorded while increasing ϕ and decreasing ϕ, respectively. The cause of lean flashback was attributed to lower momentum flux ratio which bends the jet sharply, closer toward the injection plane. The mean OH-PLIF images characterized the flame-holding behavior where the flame was found to be stabilized on the leeward side only or on both windward and leeward sides as a lifted flame near the fuel port. A large eddy simulation (LES) with detailed chemistry combustion modeling approach was implemented along with an OH* sub-mechanism, and it showed qualitative agreement with the integrated line-of-sight chemiluminescence results as well as the planar OH-PLIF measurements.

chemiluminescence diagnostic↗

Scalar mixing in the supersonic shear layer

Experiments were conducted in a two-stream planar mixing layer facility at convective Mach numbers of 0.28 and 0.62. Mie scattering from condensed alcohol droplets and planar laser-induced fluorescence (PLIF) of nitric oxide were used for flow visualization in both the side and plan views. The PLIF signals were approximately proportional to mixture fraction and were used to generate statistical quantities. Visualizations using both the Mie scattering and PLIF indicate the structure is essentially two-dimensional at Mc = 0.28 and three-dimensional at Mc = 0.62. Perspective renderings of side view images show the structures are streamwise ramped at Mc = 0.28 and cross-stream ramped at Mc = 0.62. This difference appears to be associated with decreasing streamwise structure spacings at the higher Mc condition. The statistical analysis suggests that with increasing compressibility, the scalar fluctuations are smaller, and the fraction of mixed fluid is higher.

Clemens, N. T.↗

Laser diagnostics for NTP fuel corrosion studies

Viewgraphs and explanations on laser diagnostics for nuclear thermal propulsion (NTP) fuel corrosion studies are presented. Topics covered include: NTP fuels; U-Zr-C system corrosion products; planar laser-induced fluorescence (PLIF); utilization of PLIF for corrosion product characterization of nuclear thermal rocket fuel elements under test; ZrC emission spectrum; and PLIF imaging of ZrC plume.

Wantuck, Paul J.↗

Planar Rayleigh scattering and laser-induced fluorescence for visualization of a hot, Mach 2 annular air jet

Planar Rayleigh scattering (PRS) and planar laser-induced fluorescence (PLIF) were used to investigate the vitiated air component of a coaxial hydrogen/vitiated air nonpremixed turbulent jet flame that is ejected at a Mach number of 2. All experiments were performed with a xenon chloride tunable excimer laser. Planar information for both techniques was obtained using laser sheets 6 cm high, 5 cm wide, and 300 micron thick. In this flow field, the effective Rayleigh cross section of the components in the vitiated air was assumed to be independent of composition. Therefore, the PRS technique produced signals which were proportional to total density. When the flow field was assumed to be at a known and uniform pressure, the PRS signal data for the vitiated air could be converted to temperature information. Also, PLIF images were generated by probing the OH molecule. These images contain striation patterns attributed to small localized instantaneous temperature nonuniformities. The results from the PLIF and PRS techniques were used to show that this flow field contains a nongaseous component, most likely liquid water that can be reduced by increasing the settling chamber wall temperature.

Balla, R. Jeffrey↗

Imaging of Combustion Species in a Radially-Staged Gas Turbine Combustor

Planar laser-induced fluorescence (PLIF) is used to characterize the complex flowfield of a unique fuel-lean, radially-staged, high pressure gas turbine combustor. PLIF images of OH are presented for two fuel injector configurations. PLIF images of NO, the first acquired at these conditions, are presented and compared with gas sample extraction probe measurements. Flow field imaging of nascent C2 chemiluminescence is also investigated. An examination is made of the interaction between adjoining lean premixed prevaporized (LPP) injectors. Fluorescence interferences at conditions approaching 2000 K and 15 atm are observed and attributed to polycyclic aromatic hydrocarbon (PAH) emissions. All images are acquired at a position immediately downstream of the fuel injectors with the combustor burning JP-5 fuel.

Locke, Randy J.↗

Imaging of Combustion Species in a Radially-Staged Gas Turbine Combustor

Plannar laser-induced fluorescence (PLIF) is used to characterize the complex flowfield of a unique fuel-lean, radially-staged high pressure gas turbine combustor. PLIF images of OH are presented for two fuel injector configurations. PLIF images of NO, the first acquired at these conditions, are presented and compared with gas sample extraction probe measurements. Flow field imaging of nascent C2 chemiluminescence is also investigated. An examination is made of the interaction between adjoining lean premixed prevaporized (LPP) injectors. Fluorescence interferences at conditions approaching 2000 K and 15 atm are observed and attributed to polycyclic aromatic hydrocarbon (PAH) emissions. All images are acquired at a position immediately downstream of the fuel injectors with combustor burning JP-5 fuel.

Locke, Randy J.↗

Laser-Based Flowfield Imaging in a Lean Premixed Prevaporized Sector Combustor

OH and fuel planar laser-induced fluorescence (PLIF) is used qualitatively in this study to observe the flame structure resultant from different fuel injector dome configurations within the 3-cup sector combustor test rig. The fluorescence images are compared with some computational fluid dynamics (CFD) results. Interferences in obtaining OH fluorescence signals due to the emission of other species are assessed. NO PLIF images are presented and compared to gas analysis results. The comparison shows that PLIF NO can be an excellent method for measuring NO in the flame. Additionally, we present flow visualization of the molecular species C2.

Hicks, Yolanda R.↗

Fluorescence Imaging Study of Transition in Underexpanded Free Jets

Planar laser-induced fluorescence (PLIF) is demonstrated to be a valuable tool for studying the onset of transition to turbulence. For this study, we have used PLIF of nitric oxide (NO) to image underexpanded axisymmetric free jets issuing into a low-pressure chamber through a smooth converging nozzle with a sonic orifice. Flows were studied over a range of Reynolds numbers and nozzle-exit-to-ambient pressure ratios with the aim of empirically determining criteria governing the onset of turbulence. We have developed an image processing technique, involving calculation of the standard deviation of the intensity in PLIF images, in order to aid in the identification of turbulence. We have used the resulting images to identify laminar, transitional and turbulent flow regimes. Jet scaling parameters were used to define a rescaled Reynolds number that incorporates the influence of a varying pressure ratio. An empirical correlation was found between transition length and this rescaled Reynolds number for highly underexpanded jets.

Wilkes, Jennifer A.↗

Fluorescence Visualization of Hypersonic Flow Past Triangular and Rectangular Boundary-layer Trips

Planar laser-induced fluorescence (PLIF) flow visualization has been used to investigate the hypersonic flow of air over surface protrusions that are sized to force laminar-to-turbulent boundary layer transition. These trips were selected to simulate protruding Space Shuttle Orbiter heat shield gap-filler material. Experiments were performed in the NASA Langley Research Center 31-Inch Mach 10 Air Wind Tunnel, which is an electrically-heated, blowdown facility. Two-mm high by 8-mm wide triangular and rectangular trips were attached to a flat plate and were oriented at an angle of 45 degrees with respect to the oncoming flow. Upstream of these trips, nitric oxide (NO) was seeded into the boundary layer. PLIF visualization of this NO allowed observation of both laminar and turbulent boundary layer flow downstream of the trips for varying flow conditions as the flat plate angle of attack was varied. By varying the angle of attack, the Mach number above the boundary layer was varied between 4.2 and 9.8, according to analytical oblique-shock calculations. Computational Fluid Dynamics (CFD) simulations of the flowfield with a laminar boundary layer were also performed to better understand the flow environment. The PLIF images of the tripped boundary layer flow were compared to a case with no trip for which the flow remained laminar over the entire angle-of-attack range studied. Qualitative agreement is found between the present observed transition measurements and a previous experimental roughness-induced transition database determined by other means, which is used by the shuttle return-to-flight program.

Danehy, Paul M.↗

Visualization of Flowfield Modification by RCS Jets on a Capsule Entry Vehicle

Nitric oxide planar laser-induced fluorescence (NO PLIF) has been used to visualize the flow on the aft-body of an entry capsule having an activated RCS jet in NASA Langley Research Center's 31-Inch Mach 10 wind tunnel facility. A capsule shape representative of the Apollo command module was tested. These tests were performed to demonstrate the ability of the PLIF method to visualize RCS jet flow while providing some preliminary input to NASA's Orion Vehicle design team. Two different RCS nozzle designs - conical and contoured - were tested. The conical and contoured nozzles had area ratios of 13.4 and 22.5 respectively. The conical nozzle had a half-angle of 10 . Low- and high-Reynolds number cases were investigated by changing the tunnel stagnation pressure from 350 psi to 1300 psi, resulting in freestream Reynolds numbers of 0.56 and 1.8 million per foot respectively. For both of these cases, three different jet plenum pressures were tested (nominally 56, 250 and 500 psi). A single angle-of-attack was investigated (24 degrees). NO PLIF uses an ultraviolet laser sheet to interrogate a slice in the flow containing seeded NO; this UV light excites fluorescence from the NO molecules which is detected by a high-speed digital camera. The system has spatial resolution of about 200 microns (2 pixel blurring) and has flow-stopping time resolution (approximately 1 microsecond). NO was seeded into the flow two different ways. First, the RCS jet fluid was seeded with approximately 1-5% NO, with the balance N2. This allowed observation of the shape, structure and trajectory of the RCS jets. Visualizations of both laminar and turbulent flow jet features were obtained. Visualizations were obtained with the tunnel operating at Mach 10 and also with the test section held at a constant pressure similar to the aftbody static pressure (0.04 psi) obtained during tunnel runs. These two conditions are called "tunnel on" and "tunnel off" respectively. Second, the forebody flow was seeded with a very low flowrate (<100 standard cubic centimeters per minute) of pure NO. This trace gas was entrained into and allowed visualization of the shear layer forming between the expansion fan on the shoulder of the model and the recirculating separated flow in the wake of the model. This shear layer was observed to be laminar in the absence of the RCS jet operation and turbulent above a certain RCS jet flowrate. Furthermore, the operation of the RCS jet is seen to push the shear layer out away from the model, with a higher jet pressures resulting in larger deflections. Figures show some data from this test, partially processed. In the final paper, these images will be processed and rendered on a three dimensional visualization of the test hardware for clearer visualization and interpretation of the flowfields.

Danehy, P. M.↗

Identification of Instability Modes of Transition in Underexpanded Jets

A series of experiments into the behavior of underexpanded jet flows has been conducted at NASA Langley Research Center. Two nozzles supplied with high-pressure gas were used to generate axisymmetric underexpanded jets exhausting into a low-pressure chamber. These nozzles had exit Mach numbers of 1 and 2.6, though this paper will present cases involving only the supersonic nozzle. Reynolds numbers based on nozzle exit conditions ranged from about 300 to 22,000, and nozzle exit-to-ambient jet pressure ratios ranged from about 1 to 25. For the majority of cases, the jet fluid was a mixture of 99.5% nitrogen seeded with 0.5% nitric oxide (NO). Planar laser-induced fluorescence (PLIF) of NO is used to visualize the flow, visualizing planar slices of the flow rather than path integrated measurements. In addition to revealing the size and location of flow structures, PLIF images were also used to identify unsteady jet behavior in order to quantify the conditions governing the transition to turbulent flow. Flow structures that contribute to the growth of flow instabilities have been identified, and relationships between Reynolds number and transition location are presented. By highlighting deviations from mean flow properties, PLIF images are shown to aide in the identification and characterization of flow instabilities and the resulting process of transition to turbulence.

Inman, Jennifer A.↗

Fluorescence Imaging and Streamline Visualization of Hypersonic Flow over Rapid Prototype Wind-Tunnel Models

Reentry models for use in hypersonic wind tunnel tests were fabricated using a stereolithography apparatus. These models were produced in one day or less, which is a significant time savings compared to the manufacture of ceramic or metal models. The models were tested in the NASA Langley Research Center 31-Inch Mach 10 Air Tunnel. Only a few of the models survived repeated tests in the tunnel, and several failure modes of the models were identified. Planar laser-induced fluorescence (PLIF) of nitric oxide (NO) was used to visualize the flowfields in the wakes of these models. Pure NO was either seeded through tubes plumbed into the model or via a tube attached to the strut holding the model, which provided localized addition of NO into the model s wake through a porous metal cylinder attached to the end of the tube. Models included several 2- inch diameter Inflatable Reentry Vehicle Experiment (IRVE) models and 5-inch diameter Crew Exploration Vehicle (CEV) models. Various model configurations and NO seeding methods were used, including a new streamwise visualization method based on PLIF. Virtual Diagnostics Interface (ViDI) technology, developed at NASA Langley Research Center, was used to visualize the data sets in post processing. The use of calibration "dotcards" was investigated to correct for camera perspective and lens distortions in the PLIF images.

Danehy, Paul M.↗