Search NASA⌕ Search

SEARCH · Search NASA

Results for “POTABLE WATER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Overview of Potable Water Systems on Spacecraft Vehicles and Applications for the Crew Exploration Vehicle (CEV)

Providing water necessary to maintain life support has been accomplished in spacecraft vehicles for over forty years. This paper will investigate how previous U.S. space vehicles provided potable water. The water source for the spacecraft, biocide used to preserve the water on-orbit, water stowage methodology, materials, pumping mechanisms, on-orbit water requirements, and water temperature requirements will be discussed. Where available, the hardware used to provide the water and the general function of that hardware will also be detailed. The Crew Exploration Vehicle (CEV or Orion) water systems will be generically discussed to provide a glimpse of how similar they are to water systems in previous vehicles. Conclusions on strategies that could be used for CEV based on previous spacecraft water systems will be made in the form of questions and recommendations.

Peterson, Laurie J.↗

Double ChemFET for the In-Line Monitoring of Silver Dosing in Potable Water Systems

With NASA Advanced Exploration Systems (AES) Life Support Systems (LSS)baselining ionic silver (Ag+) as the biocide of choice, development in silver monitoring technologies becomes necessary to monitor and control Ag+ release. Ion-selective field effect transistors (ISFETs) and chemically-sensitive field effect transistors (ChemFETs) are capable of selective detection of Ag+ with reversible and low detection limit responses. However, one major hurdle to ChemFET technologies is the requirement of a reference electrode, which can leak its fill solution into the potable water system and is prone to drift requiring frequent calibration. To circumvent this issue, a double chemically-sensitive field effect transistor (dChemFET) is proposed. The dChemFET uses a second ChemFET to selectively monitor the counter ion and serves in place of the reference electrode. This work reports on the development of the dChemFET, starting with the development of the Ag+ andNO3- ion selective membranes (ISMs) to be used in the ChemFETs. The Ag+ ISM was tested in 50-105 ppb Ag+ and showed linear, sub-Nernstian response. The NO3- ISM was tested in50-500 ppb silver ion equivalents of nitrate ion (Ag+ equiv. of NO3-) and shows linear, sub-Nernstian response as well . However, the Ag+ and NO3- ISMs face significant challenges in terms of drift that obstruct its application for long-term monitoring, but it can serve as a starting point for demonstrating the dChemFET proof of concept.

John Abdou↗

Antimicrobial Resources for Disinfection of Potable Water Systems for Future Spacecraft

As human exploration adventures beyond low earth orbit, life support systems will require more innovation and research to become self-sustaining and durable. One major concern about future space travel is the ability to store and decontaminate water for consumption and hygiene. This project explores materials and technologies for possible use in future water systems without requiring point-of-use (POU) filtering or chemical additives such as iodine or silver that require multiple doses to remain effective. This experimentation tested the efficacy of a variety of antimicrobial materials against biofilm formation in a high shear CDC Biofilm Reactor (CBR) and some materials in a low shear Drip Flow Reactor (DFR) which(also utilizes ultra violet light emitting diodes (UVLEDs) as an antimicrobial resource. Most materials were tested in the CBR using the ASTM E 2562-07 1method involving the Pseudomonas aeruginosa and coupon samples that vary in their antimicrobial coatings and surface layer topographies. In a controlled environmental chamber (CEC), the CBR underwent a batch phase, continuous flow phase (CFP), and a harvest before analysis. The DFR portion of this experimentation was performed in order to assess the antimicrobial capabilities of ultraviolet-A LEDs (UV-A) in potable water systems. The ASTM E 2647-08 was modified in order to incorporate UV-A LEDs and to operate as a closed, re-circulating system. The modified DFR apparatus that was utilized contains 4 separate channels each of which contain 2 UV-A LEDs (1 chamber is masked off to serve as a control) and each channel is equipped with its own reservoir and peristaltic pump head. The 10 DFR runs discussed in this report include 4 initial experimental runs that contained blank microscope slides to test the UVA LEDs alone, 2 that incorporated solid silver coupons, 2 that utilized titanium dioxide (Ti02) coupons as a photocatalyst, and 2 runs that utilized silver coated acrylic slides. Both the CBR and DFR experiments were analyzed for microbial content via heterotrophic plate counts (HPC) and acridine orange direct counts (AODC). Ofthe materials used in the CBR, only two materials performed as anti~icrobials under high shear conditions (a reduction of 5 or more logs) showing a>7 log reduction in viable microbes.

Morford, Megan A.↗

Measurement of free chlorine levels in water using potentiometric responses of biofilms and applications for monitoring and managing the quality of potable water

We report residual free chlorine is not monitored continuously at scale in drinking water distribution systems because existing real-time sensor technologies require frequent maintenance, cleaning, and calibration, which makes these products too costly to be used throughout a distribution system. As a result, current measurement approaches require manual sampling, which is not feasible for the consistent monitoring of free chlorine because chlorine concentrations vary significantly throughout pipeline distribution and over time and space. This research presents an alternative and cost-effective method of predicting free chlorine levels in drinking water using graphite electrodes coated with naturally grown microbial biofilms. This Microbial Potentiometric Sensor (MPS) array was installed in a Continuously Mixed Batch Reactor (CMBR), and drinking water containing variable free chlorine concentrations. The chlorine concentrations were introduced in a controlled manner, and the MPS signals were monitored over time. MPS signals were measured from the change in Open Circuit Potential (OCP) across the MPS array in real-time. An empirically derived relationship between the normalized change in OCP and free chlorine was established by fitting individual and average MPS data to a decaying exponential growth function in order to predict free chlorine levels. The results show that free chlorine can be predicted with reasonable accuracy, with model validation showing an average absolute error of ±0.09 ppm below 1.1 ppm and ±0.30 ppm between 1.1 and 2.7 ppm. However, the accuracy of predictions was reduced at higher free chlorine levels. The researchers conclude that MPS systems may benefit drinking water distribution systems by measuring free chlorine. These advantages of the MPS are especially pronounced in the developing world because this system is inexpensive and does not require routine maintenance or cleaning. The system relies on a naturally forming and regenerating biofilm and an inexpensive potentiometric meter to produce stable measurements.

54 ENVIRONMENTAL SCIENCES↗

U.S. Indirect and Direct Potable Water Reuse Systems (2020)

Collection of proposed, operating, demonstration, and pilot study potable reuse systems across the U.S. as of 2020. Information includes project name, location, augmentation type, capacity, year operational, treatment train, and source water type. References are included in this submission. As potable reuse facilities undergo expansions or upgrades, treatment trains and capacities are subject to change. Operational status may also change. Treatment trains listed are reported to the detail that the source provides. Type and doses of chemical post-treatment or chlorination is often not specified. Please see README section in spreadsheet for definitions of acronyms used.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

US Potable Water Reuse System Costs

This submission contains a set of U.S.-specific potable reuse capital and operations and maintenance (O&M) cost data ($2020) found in published presentations and reports from engineering consulting firms, utility and water agency press releases or websites, and literature. For any unbuilt facilities, the reported costs found in technical documents are mostly engineer estimates and may be subject to change as construction proceeds. This data set contains a mix of both facility specific and total capital costs, which include conveyance infrastructure. Note that this dataset does not include detailed cost breakdowns for each of the facilities. This submission also contains the sources used to build this dataset in pdf format.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Electrochemical approach for passivating steel and other metals and for the simultaneous production of a biocide to render water potable

Potentiostatic polarization curves indicated that the cathodic reactions in deaerated KI-I2 water solutions were due to iodine reduction and hydrogen evolution. In the presence of oxygen an additional reduction wave appeared. Anodic polarization curves revealed that iodine could be produced in the region of potential from +600 to +1000 nv vs. SCE.

Source record↗

Polyhedral Relaxations for Optimal Pump Scheduling of Potable Water Distribution Networks

The classic pump scheduling or optimal water flow (OWF) problem for water distribution networks (WDNs) minimizes the cost of power consumption for a given WDN over a fixed time horizon. In its exact form, the OWF is a computationally challenging mixed-integer nonlinear program (MINLP). It is complicated by nonlinear equality constraints that model network physics, discrete variables that model operational controls, and intertemporal constraints that model changes to storage devices. To address the computational challenges of the OWF, this paper develops tight polyhedral relaxations of the original MINLP, derives novel valid inequalities (or cuts) using duality theory, and implements novel optimization-based bound tightening and cut generation procedures. The efficacy of each new method is rigorously evaluated by measuring empirical improvements in OWF primal and dual bounds over 45 literature instances. The evaluation suggests that our relaxation improvements, model strengthening techniques, and a thoughtfully selected polyhedral relaxation partitioning scheme can substantially improve OWF primal and dual bounds, especially when compared with similar relaxation-based techniques that do not leverage these new methods.

bound tightening↗

Comparison of two culture methods for the enumeration of Legionella pneumophila from potable water samples

Legionella infections have steadily increased in the United States over the last 20 years, and most of these infections have been attributed to contaminated water. The gold standard for confirmation of Legionella presence in water is culturing with Buffered Charcoal Yeast Extract (BCYE) agar. Following many modifications, this method is still time-consuming, expensive, and can take longer than 10 days for full confirmation. The Legiolert is a newer and simpler culture product that is claimed to be able to quantify Legionella pneumophila in 7 days with high sensitivity and specificity and does not need further confirmation for the presence of L. pneumophila. This study compared the culturability of L. pneumophila occurring in a simulated home plumbing system using both Legiolert and BCYE agar methods. Out of 185 water samples, Legiolert and BCYE method detected L. pneumophila in 83 and 85% of the samples, respectively. The two methods were determined to be statistically equivalent for culturability of L. pneumophila, though the detected levels by Legiolert were slightly higher than the BCYE method. The molecular confirmation of positive (n = 254) and negative wells (n = 82) with Legiolert also showed a high specificity of 96.5% (i.e., 3.5% false positives (9/254) and 0% false negatives (0/82)).

Boczek, Laura A.↗

Geologic Assessment and Recommended New Well Locations to Improve the Area 25 Potable Water System, Nevada National Security Site

The Mission Support and Test Services, LLC (MSTS) Geoscience Operations Group performed a hydrogeologic study of an area of interest in Area 25 at the request of the MSTS Enterprise Infrastructure Program to identify potential locations for a new water well to replace J-14 Water Well (J-14 WW). Based on limited subsurface hydrogeologic data for the area, geologists developed two options for construction of a new well. Option 1 is to construct the well within approximately 250 feet (ft) of J-14 WW, and Option 2 is to construct the well approximately 1,550 ft north of J-11 Water Well (J-11 WW). Option 1 may be preferred, as the hydrogeology is better understood adjacent to an existing well. A well drilled at the Option 2 location would not have to be as deep as that at the Option 1 location, but the hydrogeologic setting is more uncertain at this greater distance from a verified subsurface geologic data point.

58 GEOSCIENCES↗

Creation of Multiple Effect Evaporator and Combined Cycle Modelica Modules, and Optimization of Potable Water Generation from Saltwater Sources (Final Technical Report)

Modelica models for a Heat Recovery Steam Generator (HRSG) and Multiple Effect Evaporator have been developed. These models have been validated against results from literature and from an actual cogeneration system on the campus of NC State University. The models are capable of connecting to other components to create multi-input, multi-output energy systems with storage, also known as integrated energy systems. An existing 35 MW gas turbine model is connected to the HRSG model created for this project to produce 9 bar steam. The high pressure steam feeds a backpressure steam turbine from the library to generate additional electric power. 2 bar steam leaves the turbine to supply an 8 effect MEE to generate water for a community. As part of the effort, three research papers were submitted (two published in ANS Proceedings and one submitted to Applied Energy).

20 FOSSIL-FUELED POWER PLANTS↗

Consequences of bacterial resistance to disinfection by iodine in potable water

This study was done to quantify the sensitivity of bacteria to iodine under controlled laboratory conditions. When exposed to 1 mg/1 I2 for 1 min, bacteria isolated from the Shuttle were more resistant than a P. aeruginosa isolated from a povidine-iodine solution. Cultures grown in rich media were more sensitive than those grown in low nutrient solutions. The P. aeruginosa and a P. cepacia isolated from the Shuttle were resuspended in PBW after exposure to iodine. Iodinated cells recovered better than uniodinated controls. Pseudomonads in biofilms developed on coupons of stainless steel were more resistant to iodine than cells suspended in buffered water. Although resistant bacteria may colonize spacecraft water systems, multiple treatment barriers should provide adequate control of these contaminants.

Mcfeters, Gordon A.↗

Influence of iodine on the treatment of spacecraft humidity condensate to produce potable water

Several compounds in the ersatz humidity condensate do react with iodine to form iodine-substituted organic compounds (TOI), most notably phenol, acetaldehyde, ethanol, and sodium formate. Iodination of the ersatz humidity condensate produced 3.0 to 3.5 mg/L of TOI within 24 hours. The TOI that was produced by the passage of the ersatz humidity condensate through the first iodinated resin (IR) in the adsorption system was removed by the granular activated carbon that followed. TOI detected in the final effluent was formed by the reaction of the non-adsorbable condensate compounds with the final IR in the treatment series. The activated carbon bed series in the adsorption system performed poorly in its removal of TOC. The rapid breakthrough of TOC was not surprising, as the ersatz humidity condensate contained several highly soluble organic compounds, alcohols and organic acids.

Symons, James M.↗

A diagnostic prototype of the potable water subsystem of the Space Station Freedom ECLSS

In analyzing the baseline Environmental Control and Life Support System (ECLSS) command and control architecture, various processes are found which would be enhanced by the use of knowledge based system methods of implementation. The most suitable process for prototyping using rule based methods are documented, while domain knowledge resources and other practical considerations are examined. Requirements for a prototype rule based software system are documented. These requirements reflect Space Station Freedom ECLSS software and hardware development efforts, and knowledge based system requirements. A quick prototype knowledge based system environment is researched and developed.

Lukefahr, Brenda D.↗

Thyroid effects of iodine and iodide in potable water

Experiments are reviewed which examine the comparative toxicological effects of iodide (I) and iodine (I2) when used to disinfect drinking water. References are made to a subchronic study in rats, a comparison of the distribution of radiolabeled I and I2, and a demonstration of thyroxine formation in the gastrointestinal tract. The results of the study of the rats are examined in detail; the findings show that I and I2 have opposite effects on the concentrations of thyroid hormones in blood. Iodide slightly decreases circulating thyroxine, while I2 significantly increases the thyroxine concentrations, decreases triiodothyronine levels, and does not change the weight of the thyroid gland. The related effects of I2 ingestion are set forth in detail and are shown to be unique to I2 contamination. Iodine can counteract the effects of iodide and should therefore be used as a disinfectant in drinking water.

Bull, Richard J.↗