Enabling Universal Access to Power on the Lunar Surface

The National Aeronautics and Space Administration (NASA) Artemis Missions will return human astronauts to the lunar surface, demonstrate technologies that establish a sustained presence on the lunar surface and enable human missions to Mars, and help create a lunar commercial economy. Creating a sustained permanent presence on the lunar surface will require access to continuous and highly reliable power to support mission needs. During Artemis, lunar surface operations will evolve and grow over time (years), requiring an increase in the amount of power needed (100s of kW) and distance that the power must be transmitted (up to 10 km during early Artemis missions). A lunar commercial economy is likely to exceed this power demand to the MW level and distance in the 100s of km. This increased distance and demand for highly reliable power drives the need to create an electric power grid by connecting localized lunar power systems (e.g., habitats, in-situ resource utilization plants, etc.), each containing one or more loads and/or sources. Developing a lunar surface power grid will allow lunar surface operations to resemble electrical utility operations on Earth; it allows power to be generated where it is convenient and allows power to be consumed where it is convenient and required. A lunar surface electric power grid will facilitate the growth of a lunar commercial economy because it provides a means to connect new loads to an existing electrical power system. A common standardized interface to the grid and a set of standardized voltages is required to take full advantage of the benefits of an electric power grid, similar to the terrestrial power grid. NASA Glenn Research Center is leading an effort to create universal access to power through the development of the Universal Modular Interface Converter (UMIC). The UMIC is designed to have a common interface that connects sources and loads compliant with the International Space Power System Interoperability Standard (ISPSIS) to a higher voltage AC transmission system or power grid. This presentation will further discuss the evolution of power during the Artemis missions, challenges associated with creating a sustained presence on the lunar surface, progress made on the UMIC, and future opportunities for technology development and standards.

space power systems↗

Design and fabrication of the waveguide Iris couplers for the Spallation Neutron Source drift tube linac

The Spallation Neutron Source (SNS) employs six cavities in the Drift Tube Linac (DTL) section to accelerate the H- ion beam to 87MeV. Each cavity is energized by a 2.5MW peak power klystron at 402.5MHz using rapid tapered waveguide iris couplers. All six original iris couplers have been in operation without replacement for over two decades. The increased RF power demands of the Proton Power Upgrade (PPU) project and operational problems, including arcing, temperature excursions, and vacuum bursts, have prompted the development of new iris coupler spares. The original iris couplers were made of GlidCop material, which is known to be mechanically strong and thermally stable, but is porous, expensive, and difficult to use in fabrication. To overcome these problems, the new spare couplers use Oxygen-Free Copper (OFC) and stainless steel (SS). This paper will discuss the mechanical, thermal and RF design, as well as challenges in the final coupler fabrication.

Lee, Sung-Woo↗

Demand Response Opportunities in Industrial Refrigerated Warehouses in California

Industrial refrigerated warehouses that implemented energy efficiency measures and have centralized control systems can be excellent candidates for Automated Demand Response (Auto-DR) due to equipment synergies, and receptivity of facility managers to strategies that control energy costs without disrupting facility operations. Auto-DR utilizes OpenADR protocol for continuous and open communication signals over internet, allowing facilities to automate their Demand Response (DR). Refrigerated warehouses were selected for research because: They have significant power demand especially during utility peak periods; most processes are not sensitive to short-term (2-4 hours) lower power and DR activities are often not disruptive to facility operations; the number of processes is limited and well understood; and past experience with some DR strategies successful in commercial buildings may apply to refrigerated warehouses. This paper presents an overview of the potential for load sheds and shifts from baseline electricity use in response to DR events, along with physical configurations and operating characteristics of refrigerated warehouses. Analysis of data from two case studies and nine facilities in Pacific Gas and Electric territory, confirmed the DR abilities inherent to refrigerated warehouses but showed significant variation across facilities. Further, while load from California's refrigerated warehouses in 2008 was 360 MW with estimated DR potential of 45-90 MW, actual achieved was much less due to low participation. Efforts to overcome barriers to increased participation may include, improved marketing and recruitment of potential DR sites, better alignment and emphasis on financial benefits of participation, and use of Auto-DR to increase consistency of participation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Battery Evaluation Profiles for X-57 and Future Urban Electric Aircraft

Battery energy density is one of the most critical design parameters for sizing all-electric aircraft, however it’s easily overestimated. Establishing the effective, usable energy density is confused by varying degrees of margin needed to account for structural and thermal management between different cell chemistry and pack designs. Therefore, a better methodology is needed to fairly compare emerging battery technologies for electric aircraft. Currently, there is a loss of critical information when vehicle trade studies are performed using “nominal” published cell-level performance metrics. Aircraft power demands rarely match these nominal power profiles, and aircraft designers lack the ability to accurately simulate the battery performance and temperature off-nominally unless the battery chemistry is well established. Conversely, battery suppliers have no generalized reference cases to publish more realistic performance metrics. This can lead to poor assumptions, such as aircraft studies assuming a fixed discharge efficiency of a battery, when in reality the usable energy in a pack is dependent on the power and thermal profile. Information needed to properly assess weight penalties for thermal management is also typically poorly characterized when assessing candidate batteries. This paper serves to better inform battery development, and similarly, provide aircraft designers with more realistic assumptions for applying knockdown margins in their designs. Detailed power and thermal performance estimates are provided, which provide a starting point for sizing power and thermal budgets using experimentally derived battery models. Results show that the X-57 battery-to-shaft efficiency is 77.3% for a particular optimized mission. Considering a 25% reserve on the battery capacity, this means that only roughly half of the original 55.3kWh ‘nominal’ pack energy can be converted to useful work during a mission. Further estimates on a clean-sheet VTOL optimization show an average 82.7% battery-to-shaft efficiency, using 98% peak efficiency inverters and 97.4% peak efficiency motors. Although higher battery efficiencies are possible, the resulting weight penalty negates improvement in vehicle performance. These trade-offs and resulting power profiles are provided as a starting point to better assess future battery designs.

Battery Electric Aircraft↗

Battery Evaluation Profiles for X-57 and Future Urban Electric Aircraft

Battery energy density is one of the most critical design parameters for sizing all-electric aircraft, however it’s easily overestimated. Establishing the effective, usable energy density is confused by varying degrees of margin needed to account for structural and thermal management between different cell chemistry and pack designs. Therefore, a better methodology is needed to fairly compare emerging battery technologies for electric aircraft. Currently, there is a loss of critical information when vehicle trade studies are performed using “nominal” published cell-level performance metrics. Aircraft power demands rarely match these nominal power profiles, and aircraft designers lack the ability to accurately simulate the battery performance and temperature off-nominally unless the battery chemistry is well established. Conversely, battery suppliers have no generalized reference cases to publish more realistic performance metrics. This can lead to poor assumptions, such as aircraft studies assuming a fixed discharge efficiency of a battery, when in reality the usable energy in a pack is dependent on the power and thermal profile. Information needed to properly assess weight penalties for thermal management is also typically poorly characterized when assessing candidate batteries. This paper serves to better inform battery development, and similarly, provide aircraft designers with more realistic assumptions for applying knockdown margins in their designs. Detailed power and thermal performance estimates are provided, which provide a starting point for sizing power and thermal budgets using experimentally derived battery models. Results show that the X-57 battery-to-shaft efficiency is 77.3% for a particular optimized mission. Considering a 25% reserve on the battery capacity, this means that only roughly half of the original 55.3kWh ‘nominal’ pack energy can be converted to useful work during a mission. Further estimates on a clean-sheet VTOL optimization show an average 82.7% battery-to-shaft efficiency, using 98% peak efficiency inverters and 97.4% peak efficiency motors. Although higher battery efficiencies are possible, the resulting weight penalty negates improvement in vehicle performance. These trade-offs and resulting power profiles are provided as a starting point to better assess future battery designs.

Battery↗

Hybrid Analytics Solution for Power Plant Operations

Expert Microsystems, Inc., MapEx Software Inc. and XMPLR Energy LLC have teamed to submit a proposal to the US Department of Energy’s Office of Fossil Energy to improve the efficiency, reliability and flexibility of existing coal-based power plants. The project, titled Hybrid Analytics Solution to Improve Coal Power Plant Operations (the “Hybrid Analytics” project), will develop, demonstrate and commercialize a novel approach that integrates two proven real-time monitoring techniques. The Hybrid Analytics approach integrates into a single, integrated solution: a) an established, advanced data-driven analytics solution that includes artificial intelligence, advanced pattern recognition and machine-learning techniques and b) a well-proven, first principle thermal heat balance model solution. The future role of coal plants will depend on the ability to cycle and follow loads to meet marginal power demands, accommodate renewables and support the grid. Essential to success in this new role is a plant’s ability to maintain high reliability, efficiency and flexibility. However, these changing operational demands put significant stresses on power plant components that directly impact the ability to deliver these requirements. In the past, plants have independently monitored performance using physics-based solutions (heat rate, boiler losses, etc.) and reliability using data-driven analytics (advanced pattern recognition). The Hybrid Analytics solution integrates both approaches to enhance fault detection, provide automated diagnostics and estimates of remaining time to act, and provide critical, enhanced and accurate real-time information to coal plant operators. As a result, coal plants can improve efficiency, reliability, and flexibility and can cost-effectively maintain their key role in the power delivery system.

01 COAL, LIGNITE, AND PEAT↗

Analyzing Power Supply and Demand on the ISS

Station Power and Energy Evaluation Determiner (SPEED) is a Java application program for analyzing the supply and demand aspects of the electrical power system of the International Space Station (ISS). SPEED can be executed on any computer that supports version 1.4 or a subsequent version of the Java Runtime Environment. SPEED includes an analysis module, denoted the Simplified Battery Solar Array Model, which is a simplified engineering model of the ISS primary power system. This simplified model makes it possible to perform analyses quickly. SPEED also includes a user-friendly graphical-interface module, an input file system, a parameter-configuration module, an analysis-configuration-management subsystem, and an output subsystem. SPEED responds to input information on trajectory, shadowing, attitude, and pointing in either a state-of-charge mode or a power-availability mode. In the state-of-charge mode, SPEED calculates battery state-of-charge profiles, given a time-varying power-load profile. In the power-availability mode, SPEED determines the time-varying total available solar array and/or battery power output, given a minimum allowable battery state of charge.

Thomas, Justin↗

What Can China Do? China's Best Alternative Outcome for Energy Efficiency and CO2 Emissions

After rapid growth in economic development and energy demand over the last three decades, China has undertaken energy efficiency improvement efforts to reduce its energy intensity under the 11th Five Year Plan (FYP). Since becoming the world's largest annual CO{sub 2} emitter in 2007, China has set reduction targets for energy and carbon intensities and committed to meeting 15% of its total 2020 energy demand with non-fossil fuel. Despite having achieved important savings in 11th FYP efficiency programs, rising per capita income and the continued economic importance of trade will drive demand for transport activity and fuel use. At the same time, an increasingly 'electrified' economy will drive rapid power demand growth. Greater analysis is therefore needed to understand the underlying drivers, possible trajectories and mitigation potential in the growing industrial, transport and power sectors. This study uses scenario analysis to understand the likely trajectory of China's energy and carbon emissions to 2030 in light of the current and planned portfolio of programs, policies and technology development and ongoing urbanization and demographic trends. It evaluates the potential impacts of alternative transportation and power sector development using two key scenarios, Continued Improvement Scenario (CIS) and Accelerated Improvement Scenario (AIS). CIS represents the most likely path of growth based on continuation of current policies and meeting announced targets and goals, including meeting planned appliance efficiency standard revisions, fuel economy standards, and industrial targets and moderate phase-out of subcritical coal-fired generation with additional non-fossil generation. AIS represents a more aggressive trajectory of accelerated improvement in energy intensity and decarbonized power and transport sectors. A range of sensitivity analysis and power technology scenarios are tested to evaluate the impact of additional actions such as carbon capture and sequestration (CCS) and integrated mine-mouth generation. The CIS and AIS results are also contextualized and compared to model scenarios in other published studies. The results of this study show that China's energy and CO{sub 2} emissions will not likely peak before 2030, although growth is expected to slow after 2020. Moreover, China will be able to meet its 2020 carbon intensity reduction target of 40 to 45% under both CIS and AIS, but only meet its 15% non-fossil fuel target by 2020 under AIS. Under both scenarios, efficiency remains a key resource and has the same, if not greater, mitigation potential as new technologies in transport and power sectors. In the transport sector, electrification will be closely linked the degree of decarbonization in the power sector and EV deployment has little or no impact on China's crude oil import demand. Rather, power generation improvements have the largest sector potential for overall emission mitigation while mine-mouth power generation and CCS have limited mitigation potential compared to fuel switching and efficiency improvements. Comparisons of this study's results with other published studies reveal that CIS and AIS are within the range of other national energy projections but alternative studies rely much more heavily on CCS for carbon reduction. The McKinsey study, in particular, has more optimistic assumptions for reductions in crude oil imports and coal demand in its abatement scenario and has much higher gasoline reduction potential for the same level of EV deployment. Despite these differences, this study's scenario analysis of both transport and power sectors illustrate the necessity for continued efficiency improvements and aggressive power sector decarbonization in flattening China's CO{sub 2} emissions.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Achieving ground-state polar molecular condensates by chainwise atom-molecule adiabatic passage

We generalize the idea of chainwise stimulated Raman adiabatic passage (STIRAP) [Kuznetsova et al., Phys. Rev. A 78, 021402(R) (2008)] to a photoassociation-based chainwise atom-molecule system, with the goal of directly converting two-species atomic Bose-Einstein condensates (BEC) into a ground polar molecular BEC. We pay particular attention to the intermediate Raman laser fields, a control knob inaccessible to the usual three-level model. We find that an appropriate exploration of both the intermediate laser fields and the stability property of the atom-molecule STIRAP can greatly reduce the power demand on the photoassociation laser, a key concern for STIRAPs starting from free atoms due to the small Franck-Condon factor in the free-bound transition.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Unified Design Theory for Multi-Port Polyphase Transformers Enabling Scalable Power-Multiplexed EV Fleet Charging Systems

This paper presents a unified analytical design theory for multi-port polyphase transformers, targeting scalable and isolated high-power Electric Vehicle (EV) fleet charging systems with power multiplexing capability. As fleet electrification accelerates, conventional one-to-one charger architectures face significant challenges in infrastructure cost, peak power demand, and low utilization of installed power electronics. Power-multiplexed charging architectures, which dynamically distribute power from a shared pool of converter modules across multiple vehicles, have emerged as a promising solution. However, such architectures require scalable, isolated multi-port power interfaces capable of routing energy among multiple inputs and outputs, whose design remains complex and dependent on iterative modeling. To address this gap, the proposed theory provides closed-form expressions for self-inductance, leakage inductance, and mutual coupling terms for arbitrary multi-phase, multi-port transformer structures. The formulation enables direct synthesis of isolated multi-input and multi-output resonant converter systems without reliance on geometry-specific finite-element analysis or extensive parameter extraction. This capability is particularly critical for power-multiplexed systems, where modular converter structures must interface with multiple vehicles while maintaining galvanic isolation and flexible power allocation. The effectiveness of the proposed framework is demonstrated through the design of a 360 kW multi-phase system operating over a 700–900 VDC input and 400–1250 VDC output range. PLECS simulation results confirm accurate prediction of system behavior and validate the applicability of the approach to multi-port, power-multiplexed charging scenarios. The proposed method significantly reduces design complexity while enabling scalable, cost-effective, and fully utilized EV fleet charging infrastructure.

Asa, Erdem [ORNL] (ORCID:0000000190884812)↗

Weight trends for a fully reusable advanced single-stage shuttle

The rate at which subsystem weights grow with vehicle gross weight is assessed and is shown to be critical to the efficiency of large Earth to orbit transports. The overall trend, however, is a reduction in the inerts as a percentage of gross weight as the vehicle size is increased. For this reason, the larger the vehicle, the greater the payload weight delivered per pound of vehicle manufactured. Other critical issues addressed include the effects of wing loading and wing size on wing weight, the effect of entry planform loading on thermal protection system weight, the impact of power demand on cooling system and prime power weight, and tank fineness ratio on insulation weight. The effects of body shape and various internal packaging arrangements on weight and balance are also discussed. The greatest impact on overall vehicle weight is body shape and internal packaging, and could account for weight savings of up to 30 percent in body structure. Other subsystems are important, but the savings are much smaller in relation to overall vehicle weight--individually less than one percent.

Macconochie, I. O.↗

Weight trends for a fully reusable advanced single-stage Shuttle

The rate at which subsystem weights grow with vehicle gross weight is assessed and is shown to be critical to the efficiency of large earth-to-orbit transports. Some subsystems grow as the square of vehicle size, others grow as the cube of vehicle size, and still others remain nearly constant irrespective of vehicle size. The overall trend, however, is a reduction in the inerts as a percentage of gross as the vehicle size is increased. For this reason, the larger the vehicle, the greater the payload weight delivered per pound of vehicle manufactured. Other critical issues addressed include the effects of wing loading and wing size on wing weight, the effect of entry planform loading on thermal protection system weight, the impact of power demand on cooling system and prime power weight, and tank fineness ratio on insulation weight. The effects of body shape and various internal packaging arrangements on weight and balance are also discussed. Of greatest impact on overall vehicle weight is body shape and internal packaging and could account for weight savings of up to 30 percent in body structure. Other subsystems are important but the savings are much smaller in relation to overall vehicle weight - individually less than one percent.

Macconochie, I. O.↗

Solar probe power systems concepts

Some of the design options under consideration for providing on-board electric power for the Solar Probe Mission are discussed. Five spacecraft configurations were evaluated with slightly different power demands and volumetric constraints on the power system. This resulted in three different baseline power system designs to satisfy the five spacecraft configurations. These three current baseline power system designs use modified general-purpose heat source (GPHS) radioisotope thermoelectric generators (RTGs) similar to those launched on the Galileo and Ulysses spacecraft. The modular RTG currently under development and testing is a potential advanced alternative to the current baseline GPHS-RTG technology design.

Nesmith, Bill J.↗

Light-Flash Wind-Direction Indicator

Proposed wind-direction indicator read easily by distant observers. Indicator emits bright flashes of light separated by interval of time proportional to angle between true north and direction from which wind blowing. Timing of flashes indicates direction of wind. Flashes, from high-intensity stroboscopic lights seen by viewers at distances up to 5 miles or more. Also seen more easily through rain and fog. Indicator self-contained, requiring no connections to other equipment. Power demand satisfied by battery or solar power or both. Set up quickly to provide local surface-wind data for aircraft pilots during landing or hovering, for safety officers establishing hazard zones and safety corridors during handling of toxic materials, for foresters and firefighters conducting controlled burns, and for real-time wind observations during any of variety of wind-sensitive operations.

Zysko, Jan A.↗