Search NASA⌕ Search

SEARCH · Search NASA

Results for “PPS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Methodology for Assessing the Status of a Physical Protection System on the Basis of Agency Inspections and Site Self-Assessments in Rosatom

The Methodology presents general approaches to the assessment of PPS status including criteria and indicators of such assessment and procedures for evaluating different aspects of physical protection, taking into consideration the significance of the criteria. The regulation includes specific methods of the application of the criteria for the evaluation of different aspects of physical protection (PP), as well as for the comprehensive assessment of the PPS status in the form of text, tables, diagrams and examples. The Methodology is intended to facilitate agency inspections and site self-assessments of PPS at a NS as well as evaluation of their results. This regulation was approved by Rosatom Headquarters in October 2008 and is currently used in the process of agency PP inspections. The Methodology was discussed by Rosatom PP specialists, who take part in agency inspections and site self-assessments, at a workshop in Moscow, June 2009, and was presented at the 4th MPC&A Conference in Obninsk, October 2009. This paper presents the methodology and its practical application during Rosatom agency inspections and site self-assessments.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Gadolinium Thin Foils in a Plasma Panel Sensor as an Alternative to 3He

Gadolinium has long been investigated as a detector for neutrons. It has a thermal neutron capture cross-section that is unparalleled among stable elements, because of the isotopes $^{155,157}$Gd. As a replacement for $^3$He, gadolinium has a significant defect, it produces many gamma-rays with an energy sum of 8 MeV. It also produces conversion electrons, mostly 29 keV in energy. The key to replacing $^3$He with gadolinium is using a gamma-blind electron detector to detect the conversion electrons. We suggest that coupling a layer of gadolinium to a Plasma Panel Sensor (PPS) can provide highly efficient, nearly gamma-blind detection of the conversion. The PPS is a proposed detector under development as a dense array of avalanche counters based on plasma display technology. We will present simulations of the response of prototypes of this detector and considerations of the use of gadolinium in the PPS.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of a Plasma Panel Muon Detector

A radiation detector technology based on Plasma Display Panels (PDP), the underlying engine of panel plasma television displays is being investigated. Emerging from this well established television technology is the Plasma Panel Sensor (PPS), a novel variant of the micropattern radiation detector. The PPS is fundamentally a fast, high resolution detector comprised of an array of plasma discharge cells operating in a hermetically sealed gas mixture. We report on the PPS development effort, including proof-of-principle results of laboratory signal observations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron Source Facility Training Simulator Based on EPICS

A plant operator training simulator is developed for training the plant operators as well as for design verification of plant control system (PCS) and plant protection system (PPS) for the Kharkov Institute of Physics and Technology Neutron Source Facility. The simulator provides the operator interface for the whole plant including the sub-critical assembly coolant loop, target coolant loop, secondary coolant loop, and other facility systems. The operator interface is implemented based on Experimental Physics and Industrial Control System (EPICS), which is a comprehensive software development platform for distributed control systems. Since its development at Argonne National Laboratory, it has been widely adopted in the experimental physics community, e.g. for control of accelerator facilities. This work is the first implementation for a nuclear facility. The main parts of the operator interface are the plant control panel and plant protection panel. The development involved implementation of process variable database, sequence logic, and graphical user interface (GUI) for the PCS and PPS utilizing EPICS and related software tools, e.g. sequencer for sequence logic, and control system studio (CSS-BOY) for graphical use interface. For functional verification of the PCS and PPS, a plant model is interfaced, which is a physics-based model of the facility coolant loops implemented as a numerical computer code. The training simulator is tested and demonstrated its effectiveness in various plant operation sequences, e.g. start-up, shut-down, maintenance, and refueling. It was also tested for verification of the plant protection system under various trip conditions.

Park, Young Soo↗

Additive Manufacturing of High Performance Semicrystalline Thermoplastics and Their Composites

This work investigates the use of two semi-crystalline high performance thermoplastics, polyphenylene sulfide (PPS) and poly (ether ketone ketone) (PEKK), as feedstock for fused filament fabrication process. Composites of PPS and PEKK are emerging as viable candidates for several components in aerospace and tooling industries and additive manufacturing of these materials can be extremely beneficial to lower manufacturing costs and lead times. However, these materials pose several challenges for extrusion and deposition due to some of their inherent properties as well as thermal and oxidative responses. To better understand the properties of such systems specific to 3D printing and determine the critical parameters that make them “printable”, various rheological and thermal properties have been studied for neat as well as short fiber reinforced PPS and PEKK systems. Attempts were also made to print these materials in a customized high temperature fused filament fabrication system.

Kishore, Vidya↗

Thermal stability of anisotropic bonded magnets prepared by additive manufacturing

Abstract In this research, anisotropic NdFeB + SmFeN hybrid and NdFeB bonded magnets are additively printed in a polyphenylene sulfide (PPS) polymer binder. Printed NdFeB + SmFeN PPS bonded magnets displayed excellent magnetic properties ( B r [remanence] = 6.9 kG [0.69 T], H cj [coercivity] = 8.3 kOe [660 kA/m], and BH max [energy product] = 9.9 MGOe [79 kJ/m 3 ]) with superior corrosion resistance and thermal stability. The anisotropic NdFeB bonded magnet shows a high coercivity of 14.6 kOe (1162 kA/m) with a BH max of 8.7 MGOe (69 kJ/m 3 ). The coercivity and remanence temperature coefficients for NdFeB + SmFeN hybrid bonded magnets are −0.10%/K and −0.46%/K, and for NdFeB bonded magnets are −0.14%/K and −0.53%/K in the range of 300–400 K, indicating that the hybrid bonded magnets are thermally stable. The average flux aging loss for hybrid magnets was also determined to be very stable over 2000 h at 448 K (175°C) in air with 2.04% compared to that of NdFeB magnets with 3.62%.

thermal stability↗

Increasing the SATS Uncertainty Safety Margin

The Surveillance and Test System (SATS) checks the functionality of ATR’s Plant Protection System (PPS). The analogue linearity test checks that the SATS analog and digital conversions are accurate to +/- 61 mVdc. This project analyzes whether this accuracy range can be increased without impacting the uncertainty analysis of the PPS system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improve durability and surface quality of additively manufactured molds using carbon fiber prepreg

Hybrid tooling is an emerging concept introduced in the aerospace industries to reduce weight and cost of traditional tools. A hybrid tool features a skin, which provides desired surface quality, durability, and a low-density substrate to reduce the weight of the mold. The big area additive manufacturing (BAAM) technology permits rapid production of thermoplastic polymer intensive large-scale structures. The present study features a carbon fiber reinforced polyphenylene sulfide (CF-PPS) substrate fabricated using Oak Ridge National Laboratory's BAAM system. Carbon fiber-bismaleimide (CF-BMI) prepreg skin was then bonded to the BAAM tool through high-pressure autoclave molding. Process optimization was conducted to improve the bonding between CF-PPS and CF-BMI (transverse tensile strength increased from 0.54 to 4.8 MPa). Durability of the mold was demonstrated from fabricating seven (7) carbon fiber-Huntsman epoxy hand lay-up parts utilizing the mold.

36 MATERIALS SCIENCE↗

Observation of proton-tagged, central (semi)exclusive production of high-mass lepton pairs in pp collisions at 13 TeV with the CMS-TOTEM precision proton spectrometer

The process pp → pℓ$^{+}$ℓ$^{−}$p$^{(*)}$, with ℓ$^{+}$ℓ$^{−}$ a muon or an electron pair produced at midrapidity with mass larger than 110 GeV, has been observed for the first time at the LHC in pp collisions at $ \sqrt{s}=13 $ TeV. One of the two scattered protons is measured in the CMS-TOTEM precision proton spectrometer (CT-PPS), which operated for the first time in 2016. The second proton either remains intact or is excited and then dissociates into a low-mass state p$^{*}$, which is undetected. The measurement is based on an integrated luminosity of 9.4 fb$^{−1}$ collected during standard, high-luminosity LHC operation. A total of 12 μ$^{+}$μ$^{−}$ and 8 e$^{+}$e$^{−}$ pairs with m(ℓ$^{+}$ℓ$^{−}$) > 110 GeV, and matching forward proton kinematics, are observed, with expected backgrounds of 1.49 ± 0.07 (stat) ± 0.53 (syst) and 2.36 ± 0.09 (stat) ± 0.47 (syst), respectively. This corresponds to an excess of more than five standard deviations over the expected background. The present result constitutes the first observation of proton-tagged γγ collisions at the electroweak scale. This measurement also demonstrates that CT-PPS performs according to the design specifications.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Reason of Discontinuation After Transarterial Chemoembolization Influences Survival in Patients with Hepatocellular Carcinoma

Background: Transarterial chemoembolization (TACE) for intermediate-stage hepatocellular carcinoma (HCC) is often repeated until unTACEable progression (UTP) occurs. There is little data on the various reasons for stopping TACE and its consequences for subsequent treatment and survival. Aim: To assess the impact of the various reasons of UTP on survival and consequences for subsequent treatments. Methods: Consecutive HCC patients who underwent TACE between 2003 and 2016 were analyzed retrospectively for the reason of TACE discontinuation. UTP was defined according to the EASL guidelines, considering radiological pattern of progression, liver function and performance status (PS). Overall and post-progression survival (OS, PPS) for different reasons of TACE discontinuation were compared. The correlation between time to untreatable progression by chemoembolization (TTUPc) and OS was analyzed. Results: One hundred and sixty-six patients (BCLC-A 40%, BCLC-B 54%, BCLC-C: 7%) were included, undergoing a median of 2 TACE procedures with a median OS of 22.1 months (95% CI 17.4–26.7). UTP occurred in 116 patients (70%) after a median TTUPc of 11.6 months (95% CI 7.8–15.4). There was a strong positive correlation (ρ = 0.816, p < 0.001) between TTUPc and OS. The main reason of UTP was radiological progression (61%), which was mostly intrahepatic (75%). Hepatic decompensation and worsening of PS were independent predictors of OS and PPS. Conclusion: The majority of HCC patients treated with TACE have UTP due to intrahepatic tumor progression with preserved liver function and PS, making them potential candidates for subsequent liver-directed or systemic treatment. TTUPc may be a valuable surrogate endpoint for OS in patients treated with TACE. Level of Evidence: Level II, prognosis study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Internal arcing and lightning strike damage in short carbon fiber reinforced thermoplastic composites

Short carbon fiber reinforced thermoplastic composites (S-CFRTP) are currently used in interior parts of aircraft such as electronic circuitry and assemblies, and their usage in aircraft's exterior is also being studied. In this paper, we present a lightning strike study on S-CFRTPs. High performance thermoplastics such as a polyphenylene sulfide (PPS) reinforced with 50% weight (wt.) short carbon fiber (CF), a polyphenyl sulfone (PPSU) reinforced with 25 % wt. Short CF and a acrylonitrile butadiene styrene (ABS) with 20 % wt. short CF were tested against artificial lightning strikes. All samples were prepared using an extrusion compression molding (ECM) technique. A modified component A (100 kA) of lightning waveform, as defined by SAE ARP 5412-B, was applied. High speed imaging, thermography, scanning electron microscopy (SEM) and ultrasonic non-destructive evaluation were performed to understand the effect of lightning strikes on the thermoplastic panels. The results show that electrical conductivity of the composite, thermal stability of the polymers, and CF orientation significantly affected the damage from artificial lightning strikes. PPS composite had the highest resilience against lightning strike damage, retaining 95% and 89% residual flexural strength and modulus, respectively. CF exfoliation due to internal arcing was observed in the carbon fiber-reinforced ABS polymer (CF-ABS) composite. CF exfoliation damage has been reported for the first time.

36 MATERIALS SCIENCE↗

Crashworthiness of recycled carbon fiber composite sinusoidal structures at dynamic rates

Fiber reinforced polymer composites are finding applications in the automotive space for structurally critical applications including crash management. The use of recycled carbon fiber reinforcement can greatly reduce carbon emissions. In this study, recycled carbon fiber composites were manufactured into a self-supporting geometry using three matrices: polyphenylene sulfide (PPS), acrylonitrile butadiene styrene (ABS), and a structural epoxy, and subsequently crushed between flat platens at dynamic rates ranging from 4.6 to 9.1 ms -1 at temperatures in a range of -40°C to 80°C. Load-displacement data was used to evaluate their specific energy absorption, crush efficiency, and steady-state crush stress. Further, the energy absorption of the ABS composites was strongly sensitive to temperature, while the PPS composites exhibited strong crush efficiency dependence with both rate and temperature. The epoxy composites exhibited stable crush behavior at dynamic crush rates but exhibited a dramatic reduction in crush efficiency relative to quasi-static tests. The results of this study indicate that recycled fiber composites can achieve very high energy absorption levels (50–80kJkg -1 at room temperature) that make them an excellent alternative to more expensive and less environmentally friendly continuous virgin fiber laminates.

42 ENGINEERING↗

Direct regeneration of degraded LiFePO4 cathodes via a separator-enabled prelithiation strategy

A persistent challenge in lithium-ion batteries is the loss of active lithium due to the solid electrolyte interphase (SEI) formation and associated side reactions. While prelithiation employing lithium replenishment separator (LRS) has been proven effective in compensating for lithium loss, previous studies have largely been accompanied by gas evolution or solid residue formation during the prelithiation process. To surmount this challenge, we present a LRS based on 4-fluoro-1,2-dihydroxybenzene lithium salt (LiDF), capable of mitigating lithium loss while producing decomposition products that integrate directly into the electrolyte as functional additives which can assist with the stability of the SEI, free from gas or solid formation, thus establishing a sustainable and environmentally benign strategy for lithium compensation. Incorporation of the LRS enables the pristine LiFePO4||graphite (Gr) full cell to achieve 10.8% higher capacity than the cell with a polypropylene separator (PPS) after 200 cycles at 0.5C. Remarkably, the degraded LiFePO4 (D-LFP)||Gr full cell with the LRS exhibits a 135.8% capacity improvement over the PPS-based cell after 500 cycles. These findings establish the LRS as a powerful approach for both boosting high-performance lithium-ion batteries and recovering the capacity of degraded batteries.

Tao, Fujun↗

Mass spectrometric investigations into 3D printed parts to assess radiopurity as ultralow background materials for rare event physics detectors

The mass concentrations of 232 Th and 238 U in several 3D printing filaments and printed polymer parts are reported as measures of their radiopurity. In order to minimize background signals in rare event physics detectors, radiopure polymers are necessary as dielectric and structural materials in their construction. New data are reported for polyvinylidene fluoride (PVDF), polyphenylene sulfide (PPS), and two forms of polyetherimide (PEI, branded ULTEM 1010 and 9085). Data for starting filaments and both simple and complex printed parts are reported. PVDF filaments and simple printed beads, were found to have values of approximately 30 and 50 pg g -1 for 232 Th and 238 U, respectively, while a more complex spring clip part had slightly elevated 232 Th levels of 65 pg g -1 , with 238 U remaining at 50 pg g -1 . PPS filament was found to have concentrations of 270 and 710 pg g -1 for 232 Th and 238 U, respectively, and were not chosen to be printed as those levels were already higher than other material options. ULTEM 1010 filaments and printed complex spring clip parts were found to have concentrations of around 5 and 7 pg g -1 for 232 Th and 238 U, respectively, illustrating no significant contamination from the printing process. ULTEM 9085 filaments were found to have concentrations of around 9 and 5 pg g -1 for 232 Th and 238 U, respectively, while the printed complex spring clip part was found to have slightly elevated concentrations of 25 and 7 pg g -1 for 232 Th and 238 U, respectively. All these results were obtained using a novel dry ashing method in crucibles constructed of ultralow background electroformed copper or, when applicable, microwave assisted wet ashing digestion. Samples and process blanks were spiked with 229 Th and 233 U as internal standards prior to dry/wet ashing and determinations were made by inductively coupled plasma mass spectrometry (ICP-MS). In order to maintain high radiopurity levels, pre-cleaning the filaments before printing and post-cleaning the parts is recommended, although the printing process itself has shown to contribute very minute amounts of radiocontaminants.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Proposed new accelerator design for homeland security x-ray applications

Two goals for security scanning of cargo and freight are the ability to determine the type of material that is being imaged, and to do so at low radiation dose. One commonly used technique to determine the effective Z of the cargo is dual-energy imaging, i.e. imaging with different x-ray energy spectra. Another technique uses the fact that the transmitted x-ray spectrum itself also depends on the effective Z. Spectroscopy is difficult because the energy of individual x rays needs to be measured in a very high count-rate environment. Typical accelerators for security applications offer large but short bursts of x-rays, suitable for current-mode integrated imaging. In order to perform x-ray spectroscopy, a new accelerator design is desired that has the following features: 1) increased duty factor in order to spread out the arrival of x-rays at the detector array over time; 2) x-ray intensity modulation from one delivered pulse to the next by adjusting the accelerator electron beam instantaneous current so as to deliver adequate signal without saturating the spectroscopic detector; and 3) the capability to direct the (forward peaked) x-ray intensity towards high-attenuation areas in the cargo (“fan-beam-steering”). Current sources are capable of 0.1% duty factor, although usually they are operated at significantly lower duty factors (~0.04%), but duty factors in the range 0.4-1.0% are desired. The higher duty factor can be accomplished, e.g., by moving from 300 pulses per second (pps) to 1000 pps and/or increasing the pulse duration from a typical 4 μs to 10 μs. This paper describes initial R&D to examine cost effective modifications that could be performed on a typical accelerator for these purposes, as well as R&D for fan-beam steering.

43 PARTICLE ACCELERATORS↗

Compatibility Assessment of Fuel System Infrastructure Plastics with Bio-oil and Diesel Fuel

We report that bio-oil derived via fast pyrolysis is being developed as a renewable fuel option for petroleum distillates. The compatibility of neat bio-oil with 18 plastic types was evaluated using neat diesel fuel as the baseline. The plastic materials included polyphenylene sulfide (PPS), polyethylene terephthalate (PET), polytetrafluoroethylene (PTFE), polyvinylidene fluoride (PVDF), polyoxymethylene (POM), POM copolymer, high density polyethylene (HDPE), polybutylene terephthalate (PBT), polypropylene (PP), polyethylene terephthalate glycol (PETG), polythiourea (PTU), four nylon grades, and four thermosetting resins. Specimens of each material were immersed in the test fuels for a period of 16 weeks to achieve full saturation. Except for PP and HDPE, the plastic materials underwent higher volume expansion in bio-oil than in the baseline diesel (which was negligible in most cases). This volume increase corresponds to the higher polarity of the bio-oil. PPS, PET, and PTFE were unaffected by bio-oil exposure, but modest swelling (between 2 and 5%) occurred for the two acetals (POM and POM copolymer), Nylon-12, PBT, PETG, and the four resin grades. More moderate swelling (8–15%) was noted for Nylon-6, Nylon-6/6, and Nylon-11, and excessive swell (>40%) occurred for PTU. The nonpolar nature of PP and HDPE matches that of diesel, leading to higher solubility (swell) in this fuel type. Finally, the relatively low volume expansion following exposure indicates that many of the existing infrastructure plastics (excluding PTU) should be suitable for use with bio-oil.

09 BIOMASS FUELS↗

Molecularly engineered Li compensation agent-integrated separator enabling regeneration of degraded LiFePO 4

Lithium replenishment separators (LRSs) integrating pre-lithiation agents can regenerate degraded lithium cathodes via facile reassembly with a fresh anode and the LRS. A persistent challenge is the formation of gas or solid residues during pre-lithiation. To address this, for the first time, we develop an LRS based on a molecularly engineered dilithium salt of tetrafluorohydroquinone, which compensates for lithium loss while generating decomposition products that dissolve in the electrolyte as a favorable additive, without forming gas or solid residues, thus offering a green route for lithium compensation. A pristine LiFePO 4 ‖graphite full cell with the LRS exhibits 9.3% higher overall capacity than a polypropylene separator (PPS) cell after 50 cycles at 0.5C, and the degraded LiFePO 4 ‖graphite full cell incorporating this LRS achieves a 44.9% higher capacity than the PPS-based cell after 200 cycles at 0.5C. Our LRS demonstrates strong potential for high-performance lithium-ion batteries and spent battery regeneration.

Tao, Fujun [Worcester Polytechnic Institute, MA (U↗

A review of ion sources for medical accelerators (invited)

There are two major medical applications of ion accelerators. One is a production of short-lived isotopes for radionuclide imaging with positron emission tomography and single photon emission computer tomography. Generally, a combination of a source for negative ions (usually H- and/or D-) and a cyclotron is used; this system is well established and distributed over the world. Other important medical application is charged-particle radiotherapy, where the accelerated ion beam itself is being used for patient treatment. Two distinctly different methods are being applied: either with protons or with heavy-ions (mostly carbon ions). Proton radiotherapy for deep-seated tumors has become widespread since the 1990s. The energy and intensity are typically over 200 MeV and several 10{sup 10} pps, respectively. Cyclotrons as well as synchrotrons are utilized. The ion source for the cyclotron is generally similar to the type for production of radioisotopes. For a synchrotron, one applies a positive ion source in combination with an injector linac. Carbon ion radiotherapy awakens a worldwide interest. About 6000 cancer patients have already been treated with carbon beams from the Heavy Ion Medical Accelerator in Chiba at the National Institute of Radiological Sciences in Japan. These clinical results have clearly verified the advantages of carbon ions. Heidelberg Ion Therapy Center and Gunma University Heavy Ion Medical Center have been successfully launched. Several new facilities are under commissioning or construction. The beam energy is adjusted to the depth of tumors. It is usually between 140 and 430 MeV/u. Although the beam intensity depends on the irradiation method, it is typically several 10{sup 8} or 10{sup 9} pps. Synchrotrons are only utilized for carbon ion radiotherapy. An ECR ion source supplies multi-charged carbon ions for this requirement. Some other medical applications with ion beams attract developer's interests. For example, the several types of accelerators are under development for the boron neutron capture therapy. This treatment is conventionally demonstrated by a nuclear reactor, but it is strongly expected to replace the reactor by the accelerator. We report status of ion source for medical application and such scope for further developments.

43 PARTICLE ACCELERATORS↗