Search NASA⌕ Search

SEARCH · Search NASA

Results for “PRISM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Radiometric and spectral stray light correction for the Portable Remote Imaging Spectrometer (PRISM) coastal ocean sensor

The airborne Portable Remote Imaging Spectrometer (PRISM) instrument is based on a fast (F/1.8) Dyson spectrometer operating at 350-1050 nm and a two-mirror telescope combined with a Teledyne HyViSI 6604A detector array. Raw PRISM data contain electronic and optical artifacts that must be removed prior to radiometric calibration. We provide an overview of the process transforming raw digital numbers to calibrated radiance values. Electronic panel artifacts are first corrected using empirical relationships developed from laboratory data. The instrument spectral response functions (SRF) are reconstructed using a measurement-based optimization technique. Removal of SRF effects from the data improves retrieval of true spectra, particularly in the typically low-signal near-ultraviolet and near-infrared regions. As a final step, radiometric calibration is performed using corrected measurements of an object of known radiance. Implementation of the complete calibration procedure maximizes data quality in preparation for subsequent processing steps, such as atmospheric removal and spectral signature classification.

Thompson, David R.↗

Overview of Phobos/Deimos Regolith Ion Sample Mission (PRISM) Concept

Far more definitive information on composition is required to resolve the question of origin for the Martian moons Phobos and Deimos. Current infrared spectra of the objects are inconclusive due to the lack of strong diagnostic features. Definitive compositional measurements of Phobos could be obtained using in-situ X-ray, gamma-ray, or neutron spectroscopy or collecting and returning samples to Earth for analysis. We have proposed, in lieu of those methods, to derive Phobos and Deimos compositional data from secondary ion mass spectrometry (SIMS) measurements by calibrating the instrument to elemental abundance measurements made for known samples in the laboratory. We describe the Phobos/Deimos Regolith Ion Sample Mission (PRISM) concept here. PRISM utilizes a high-resolution TOF plasma composition analyzer to make SIMS measurements by observing the sputtered species from various locations of the moons' surfaces. In general, the SIMS technique and ion mass spectrometers complement and expand quadrupole mass spectrometer measurements by collecting ions that have been energized to higher energies, 50-100 eV, and making measurements at very low densities and pressures. Furthermore, because the TOF technique accepts all masses all the time, it obtains continuous measurements and does not require stepping through masses. The instrument would draw less than 10 W and weigh less than 5 kg. The spacecraft, nominally a radiation-hardened 12U CubeSat, would use a low-thrust Solar Electric Propulsion system to send it on a two-year journey to Mars, where it would co-orbit with Deimos and then Phobos at distances as low as 27 km.

Dibraccio, Gina↗

Sensorimotor Application of Proposed Methods to Combine the Effects of Multiple Countermeasures for PRisM

Risk associated with human systems is challenging to quantify but is critical for the mission planning and decision making required to enable future Lunar and Martian missions. To address this gap, the Crew Health and Performance-Probabilistic Risk Assessment (CHP-PRA) project is developing an integrated computational model for CHP mission risk. Much like how MEDPRAT is designed to allow medical resource trades informed by medical risk, CHP-PRA will enable analogous trades in human system risks across multiple CHP functions and capabilities. Human performance is one component of the risk intended to be captured by CHP-PRA through the Performance Risk Model (PRisM). The sensorimotor risk area provides a good frame of reference for investigating the structure of a performance model because most tasks that astronauts are expected to perform require input from the sensory system and/or movement/motor control. Additionally, sensorimotor countermeasures are an area of particular concern for NASA’s Human Research Program because of the increased sensorimotor risk associated with surface operations in Lunar and Martian missions. Thus, a tool that can quickly compare risk reductions of potential countermeasures would be beneficial in guiding research and development of effective countermeasures. In this proof of concept, we present a systematic way to combine multiple performance data sets for humans subjected to different countermeasures such that we can predict the countermeasure(s) that optimize astronaut performance on relevant tasks. PRisM assumes that both the tests that are used to measure countermeasure effectiveness (input data) and the tasks we use to represent astronaut performance, can be broken down and represented as a function/vector of the human systems required to perform that test/task. Through mathematical combination, test data are used to predict performance on astronaut tasks that use similar systems. We propose that when combining countermeasures evaluated using the same test, that only one value should be used to represent their combined effectiveness. We start our analysis with the assumption that two countermeasures together will perform better than each countermeasure individually. Our initial implementation of this framework compares various space motion sickness countermeasures and the most up to date analysis will be demonstrated at the IWS.

Caroline R Austin↗

Perspectives for Measuring Neutrino Cross-Sections at Short Baseline Detectors (ICARUS and DUNE-PRISM-like Detector) and Their Implications for Precision Physics

Neutrino physics is rapidly advancing with current and future experiments promising high-statistics data, enabling unprecedented accuracy in measuring Standard Model (SM) parameters and providing crucial insights into neutrino-nucleus interactions. The ICARUS experiment, utilizing LAr TPC technology, is pivotal in this growth. As the far detector of the SBN program at Fermilab, ICARUS is set to investigate the neutrino anomalies observed in LSND and MiniBooNE and prepare for future long-baseline experiments like DUNE. Positioned along the BNB and 5.75°off-axis from the NuMI beamline, ICARUS benefits from numerous neutrino interactions, allowing for precise neutrino-argon nucleus cross-section measurements, which will benchmark future DUNE measurements. This work presents the prospects and progress in measuring the cross-section of the NuMI νµ CC inclusive channel in the ICARUS experiment. High-statistics data will also enable precise determinations of fundamental parameters like the weak mixing angle and the neutrino charge radius (NCR), crucial for testing the SM and exploring potential new physics. This work includes studies of future near detectors, such as DUNE-PRISM, which are sensitive to radiative corrections in neutrino-electron scattering. The DUNE-PRISM configuration allows for the analysis of different neutrino energy spectra, promising accurate NCR measurements with controlled systematic uncertainties.

Moreno-Granados, Guadalupe↗

Development of an x-ray prism for analyzer based imaging systems

Analyzer crystal based imaging techniques such as diffraction enhanced imaging (DEI) and multiple imaging radiography (MIR) utilize the Bragg peak of perfect crystal diffraction to convert angular changes into intensity changes. These x-ray techniques extend the capability of conventional radiography, which derives image contrast from absorption, by providing large intensity changes for small angle changes introduced from the x-ray beam traversing the sample. Objects that have very little absorption contrast may have considerable refraction and ultrasmall angle x-ray scattering contrast improving visualization and extending the utility of x-ray imaging. To improve on the current DEI technique an x-ray prism (XRP) was designed and included in the imaging system. The XRP allows the analyzer crystal to be aligned anywhere on the rocking curve without physically moving the analyzer from the Bragg angle. By using the XRP to set the rocking curve alignment rather than moving the analyzer crystal physically the needed angle sensitivity is changed from submicroradians for direct mechanical movement of the analyzer crystal to tens of milliradians for movement of the XRP angle. However, this improvement in angle positioning comes at the cost of absorption loss in the XRP and depends on the x-ray energy. In addition to using an XRP for crystal alignment it has the potential for scanning quickly through the entire rocking curve. This has the benefit of collecting all the required data for image reconstruction in a single measurement thereby removing some problems with motion artifacts which remain a concern in current DEI/MIR systems especially for living animals.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Demonstration of a directional sonic prism in two dimensions using an air-acoustic leaky wave antenna

Analysis and experimental demonstration of a two-dimensional acoustic leaky wave antenna is presented for use in air. The antenna is comprised of a two-dimensional waveguide patterned with radiating acoustic shunts. When excited using a single acoustic source within the waveguide, the antenna acts as a sonic prism that exhibits frequency steering. This design allows for control of acoustic steering angle using only a single source transducer and a patterned aperture. Aperture design was determined using transmission line analysis and finite element methods. The designed antenna was fabricated and the steering angle measured. The performance of the measured aperture was within 9% of predicted angle magnitudes over all examined frequencies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The linear phase correction of modulation of intensity emerging from zero effort (MIEZE) with magnetic Wollaston prisms

This study proposes the use of two magnetic Wollaston prisms (MWPs) to correct for the linear Larmor phase aberration of modulation of intensity emerging from zero effort (MIEZE), introduced by the transverse size of the sample. With this approach, the contrast of the intensity modulation can be maximized at any scattering angle of interest such that the same contrast as the direct transmission geometry can be fully recovered. The optimum magnetic fields required for the MWPs depend only on the scattering angle and the frequencies of the radio-frequency flippers, and they are independent of the neutron wavelength and beam divergence, which makes the approach suitable for both pulsed and continuous neutron sources.

36 MATERIALS SCIENCE↗

Analysis of Errors in Recording and Reading of a Holographic Prism on Photothermorefractive Glass

The influence of deviation of recording and reading conditions of multiplex Bragg gratings from calculated values on the parameters of restorable fan of beams of a holographic prism (HP) formed by Bragg gratings in photothermorefractive glass is analyzed. Deviations are specified either as a rotation of the sample around one of three orthogonal axes Oxyz or as simultaneous rotation of the sample around two axes. It is shown that errors in the sample installation do not affect quality of the HP in recording if all gratings are recorded with the same deviation from an ideal position. However, difference in errors at the recording of each grating results is a reduction of flatness of fan of the HP and a loss of its working capacity. Ultimate values of errors of rotation around the Ox and Oy axes allowing one to maintain HP functionality, i.e., simultaneous reconstruction of all its beams, are calculated. It is established that, in the case of an ideally recorded HP, errors in the stage of reading may result in twisting the fan and disrupting its flatness.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Prism Mass-Spectrometer for Isotope Analysis of Hydrogen–Helium Mixtures

An original scheme of a special magnetic mass-spectrometer for isotope measurements in a mass range of hydrogen–helium mixtures and their main impurities is proposed. The ion optics system contains a two-dimensional magnetic prism supplemented with two identical cylindrical electrostatic capacitors matched so that the system operates in the regime of complete triple focusing of the ion beam in two orthogonal directions and with respect to ion energies. The system ensures high dispersion and allows the mass resolution (no less than 3500) required for analysis at high brightness and a central ion trajectory length on the order of 1 m.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Dual-prism interferometer for collimation testing

An air-wedge lateral-shear interferometer using two prisms is presented. With a variable shear, the interferometer is suitable for testing collimation of a wide range of beam sizes down to a few millimeters in diameter. No antireflection coatings are necessary. Collimation for a light source with short coherent length is also demonstrated.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High-accuracy interferometer with a prism pair for measurement of the absolute refractive index of glass

We propose a variable-path interferometric technique for the measurement of the absolute refractive index of optical glasses. We use two interferometers to decide the ratio between changes in the optical path in a prism-shaped sample glass and in air resulting from displacement of the sample. The method allows precise measurements to be made without prior knowledge of the properties of the sample. The combined standard uncertainty of the proposed method is 1.6x10{sup -6}.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Exploiting the PRISM Feature and Purity Monitors of the SBND Neutrino Detector

The Short-Baseline Neutrino (SBN) program at Fermilab will pursue neutrino properties searches, exploiting three Liquid Argon Time Projection Chamber (LArTPC) experiments to investigate neutrino oscillations with neutrinos from the Booster Neutrino Beam (BNB). SBND will be the near detector in the program, measuring the un-oscillated flux. It is anticipated to begin operating in 2023. Thanks to its peculiar proximity to the neutrino source of about 110 meters, SBND will collect extremely high statistics data of the flux in the GeV energy range, providing unprecedented precision measurements. SBND particular setting also allows to take measurements at different distances from BNB’s center maintaining statistics high enough at each range. LArTPC and the cold electronics technologies, as well as the argon-neutrino interaction studies, will play a key role in future neutrino physics. In this prospect, this work was focused on two SBND features: SBND PRISM tool, with the aim of investigating neutrino flux at different distances from the beam axis, and Purity Monitors, which provide a clever measurement of argon purity in the detector, whose value is fundamental in neutrino-argon interaction.

43 PARTICLE ACCELERATORS↗

Squeezing a Prism into a Surface: Emulating Bulk Optics with Achromatic Metasurfaces

Metasurfaces promise to replace bulky prisms and lenses with 2D surfaces, revolutionizing wavefront control with technologically significant advantages in size, weight, and planar fabrication. However, conventional implementations suffer from large chromatic aberrations and cannot sustain performance over practical bandwidths of real-world signals because of the limited phase modulation margin available in a surface. How can an infinitely thin surface generate the arbitrarily large, broadband phase delay that bulk phase accumulation can provide? Here, equivalence between bulk optics and certain multiresonant metasurfaces is demonstrated, where phase delay arises from trains of multiple resonances in the effective sheet conductivities of the surface itself instead of accumulation of propagation phase. The fundamentally required electromagnetic surface conductivities of a purely achromatic metasurface are derived and general design rules for arbitrarily broadband beam steering and lensing are obtained. Both operation in transmission and reflection can be achieved in a unified way by proper alignment of the resonances, enabling 360° directionality. The arbitrary spectral bandwidth, dual reflection/transmission operation, and complete dispensability of propagation phase constitute a major advance in the state of the art of achromatic metasurfaces for wavefront manipulation.

36 MATERIALS SCIENCE↗

Plasma-based prism compressor design for high-intensity laser pulses

A concept for a femtosecond pulse compressor based on underdense plasma prisms is presented. An analytical model is developed to calculate the spectral phase incurred and the expected pulse compression. A 2D particle-in-cell simulation verifies the analytical model. Simulated intensities ( ∼10 16 W/cm 2 ) were orders of magnitude higher than the damage threshold for conventional gratings used in chirped pulse amplification. Theoretical geometries for compact (tens of cm scale) compressors for 1, 10 and 100 PW power levels are proposed.

47 OTHER INSTRUMENTATION↗

Infrared detection of (H 2 O) 20 isomers of exceptional stability: A drop-like and a face-sharing pentagonal prism cluster

Water clusters containing fully coordinated water molecules are model systems that mimic the local environment of the condensed phase. Present knowledge about the water cluster size regime in which the transition from the allsurface to the fully solvated water molecules occurs is mainly based on theoretical predictions in lieu of the absence of precisely size resolved experimental measurements. Here, we report size and isomer selective infrared (IR) spectra of (H 2 O) 20 clusters tagged with a sodium atom by employing IR excitation modulated photoionization spectroscopy. The observed absorption patterns in the OH stretching ”fingerprint” region are consistent with the theoretically predicted spectra of two structurally distinct isomers: A drop-like cluster with a fully coordinated (interior) water and an edge-sharing pentagonal prism cluster in which all atoms are on the surface. The observed isomers show exceptional stability and are predicted to be nearly isoenergetic.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗