Search NASA⌕ Search

SEARCH · Search NASA

Results for “PROTON IMPACT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Emulating the impact of additional proton-proton interactions in the ATLAS simulation by pre-sampling sets of inelastic Monte Carlo events

The accurate simulation of additional interactions at the ATLAS experiment for the analysis of proton-proton collisions delivered by the Large Hadron Collider presents a significant challenge to the computing resources. During the LHC Run (2015-2018) there were up to 70 inelastic interactions per bunch crossing, which need to be accounted for in Monte Carlo (MC) production. In this document, a new method to account for these additional interactions in the simulation chain is described. Instead of sampling the inelastic interactions and adding their energy deposits to a hard-scatter interaction one-by-one, the inelastic interactions are presampled, independent of the hard scatter, and stored as combined events. Consequently, for each hard-scatter interaction only one such presampled event needs to be added as part of the simulation chain. For the Run 2 simulation chain, with an average of 35 interactions per bunch crossing, this new method provides a substantial reduction in MC production CPU needs of around 20%, while reproducing the properties of the reconstructed quantities relevant for physics analyses with good accuracy.

97 MATHEMATICS AND COMPUTING↗

Exploring the Impacts of Conditioning on Proton Exchange Membrane Electrolyzers by In Situ Visualization and Electrochemistry Characterization

For a proton exchange membrane electrolyzer cell (PEMEC), conditioning is an essential process to enhance its performance, reproducibility, and economic efficiency. To get more insights into conditioning, a PEMEC with Ir-coated gas diffusion electrode (IrGDE) was investigated by electrochemistry and in situ visualization characterization techniques. The changes of polarization curves, electrochemical impedance spectra (EIS), and bubble dynamics before and after conditioning are analyzed. The polarization curves show that the cell efficiency increased by 9.15% at 0.4 A/cm 2 , and the EIS and Tafel slope results indicate that both the ohmic and activation overpotential losses decrease after conditioning. The visualization of bubble formation unveils that the number of bubble sites increased greatly from 14 to 29 per pore after conditioning, at the same voltage of 1.6 V. Under the same current density of 0.2 A/cm 2 ; the average bubble detachment size decreased obviously from 35 to 25 µm. Furthermore, the electrochemistry and visualization characterization results jointly unveiled the increase of reaction sites and the surface oxidation on the IrGDE during conditioning, which provides more insights into the conditioning and benefits for the future GDE design and optimization.

08 HYDROGEN↗

Four-dimensional Monte Carlo simulations demonstrating how the extent of intensity-modulation impacts motion effects in proton therapy lung treatments

Purpose: To compare motion effects in intensity modulated proton therapy (IMPT) lung treatments with different levels of intensity modulation.Methods: Spot scanning IMPT treatment plans were generated for ten lung cancer patients for 2.5Gy(RBE) and 12Gy(RBE) fractions and two distinct energy-dependent spot sizes (σ∼8–17 mm and ∼2–4 mm). IMPT plans were generated with the target homogeneity of each individual field restricted to <20% (IMPT{sub 20%}). These plans were compared to full IMPT (IMPT{sub full}), which had no restriction on the single field homogeneity. 4D Monte Carlo simulations were performed upon the patient 4DCT geometry, including deformable image registration and incorporating the detailed timing structure of the proton delivery system. Motion effects were quantified via comparison of the results of the 4D simulations (4D-IMPT{sub 20%}, 4D-IMPT{sub full}) with those of a 3D Monte Carlo simulation (3D-IMPT{sub 20%}, 3D-IMPT{sub full}) upon the planning CT using the equivalent uniform dose (EUD), V{sub 95} and D{sub 1}-D{sub 99}. The effects in normal lung were quantified using mean lung dose (MLD) and V{sub 90%}.Results: For 2.5Gy(RBE), the mean EUD for the large spot size is 99.9%± 2.8% for 4D-IMPT{sub 20%} compared to 100.1%± 2.9% for 4D-IMPT{sub full}. The corresponding values are 88.6%± 8.7% (4D-IMPT{sub 20%}) and 91.0%± 9.3% (4D-IMPT{sub full}) for the smaller spot size. The EUD value is higher in 69.7% of the considered deliveries for 4D-IMPT{sub full}. The V{sub 95} is also higher in 74.7% of the plans for 4D-IMPT{sub full}, implying that IMPT{sub full} plans experience less underdose compared to IMPT{sub 20%}. However, the target dose homogeneity is improved in the majority (67.8%) of plans for 4D-IMPT{sub 20%}. The higher EUD and V{sub 95} suggests that the degraded homogeneity in IMPT{sub full} is actually due to the introduction of hot spots in the target volume, perhaps resulting from the sharper in-target dose gradients. The greatest variations between the IMPT{sub 20%} and IMPT{sub full} deliveries are observed for patients with the largest motion amplitudes. These patients would likely be treated using gating or another motion mitigation technique, which was not the focus of this study.Conclusions: For the treatment parameters considered in this study, the differences between IMPT{sub full} and IMPT{sub 20%} are only likely to be clinically significant for patients with large (>20 mm) motion amplitudes.

61 RADIATION PROTECTION AND DOSIMETRY↗

Database for inelastic collisions of sodium atoms with electrons, protons, and multiply charged ions

The available experimental and theoretical cross section data for inelastic collision processes of ground (3s) and excited (3p, 4s, 3d, 4p, 5s, 4d, and 4f) state Na atoms with electrons, protons, and multiply charged ions have been collected and critically assessed. In addition to existing data, electron-impact cross sections, for both excitation and ionization, have been calculated using the convergent close-coupling approach. In the case of proton-impact cross section, the database was enlarged by new atomic-orbital close-coupling calculations. Both electron-impact and proton-impact processes include excitation from the ground state and between excited states (n = 3-5). For electron-impact, ionization from all states is also considered. In the case of proton-impact electron loss, cross sections (the sum of ionization and single-electron charge transfer) are given. Well-established analytical formulae used to fit cross sections, published by Wutte et al. and Schweinzer et al. for collisions with lithium atoms, were adapted to sodium. The 'recommended cross sections' for the processes considered have been critically evaluated and fitted using the adapted analytical formulae. For each inelastic process the fit parameters determined are tabulated. We also present the assessed data in graphical form. The criteria for comprehensively evaluating the accuracy of the experimental data, theoretical calculations, and procedures used in determining the recommended cross sections are discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Brightness measurement of an electron impact gas ion source for proton beam writing applications

We are developing a high brightness nano-aperture electron impact gas ion source, which can create ion beams from a miniature ionization chamber with relatively small virtual source sizes, typically around 100 nm. A prototype source of this kind was designed and successively micro-fabricated using integrated circuit technology. Experiments to measure source brightness were performed inside a field emission scanning electron microscope. The total output current was measured to be between 200 and 300 pA. The highest estimated reduced brightness was found to be comparable to the injecting focused electron beam reduced brightness. This translates into an ion reduced brightness that is significantly better than that of conventional radio frequency ion sources, currently used in single-ended MeV accelerators.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Correlation of proton irradiation induced threshold voltage shifts to deep level traps in AlGaN/GaN heterostructures

The impact of proton irradiation on the threshold voltage (V{sub T}) of AlGaN/GaN heterostructures is systematically investigated to enhance the understanding of a primary component of the degradation of irradiated high electron mobility transistors. The value of V{sub T} was found to increase monotonically as a function of 1.8 MeV proton fluence in a sub-linear manner reaching 0.63 V at a fluence of 1 × 10{sup 14} cm{sup −2}. Silvaco Atlas simulations of V{sub T} shifts caused by GaN buffer traps using experimentally measured introduction rates, and energy levels closely match the experimental results. Different buffer designs lead to different V{sub T} dependences on proton irradiation, confirming that deep, acceptor-like defects in the GaN buffer are primarily responsible for the observed V{sub T} shifts. The proton irradiation induced V{sub T} shifts are found to depend on the barrier thickness in a linear fashion; thus, scaling the barrier thickness could be an effective way to reduce such degradation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Simulation and measurement of the dynamic strain response in a prototypical spallation target

The Second Target Station (STS) at the Spallation Neutron Source (SNS) will address emerging scientific challenges by providing a source of intense cold neutrons to instruments optimized for this source. The STS target will use rotating tungsten blocks and will receive 1.3 GeV proton beam pulses from the SNS accelerator at a repetition rate of 15 Hz. The facility life is planned for 40 years, and each target assembly life is expected to be approximately 10 years. An accurate strain prediction is then critical for fatigue life assessment of STS target blocks because they will be subject to approximately 10 8 beam pulses per lifetime. As an R&D activity, the Los Alamos Neutron Science Center (LANSCE) Weapons Neutron Research (WNR) Target 2 (Blue Room) facility was used to test the strain response of prototypical target blocks to the thermal shock of a proton pulse. The blue room was well suited for a pulsed proton beam impact test of subscale STS target blocks; the 800 MeV proton energy is approximately 60 % of the 1.3 GeV proton energy expected from the SNS accelerator to the STS. The LANSCE Proton Storage Ring (PSR) and SNS are both short-pulse proton beam sources with nominal pulse widths of 250 ns and 661 ns, respectively, so the energy deposition in the target occurs in <1 μs pulse duration. Strain measurements on the outer surface of three target blocks (bare tungsten, tantalum-clad tungsten, niobium-clad tungsten) were recorded for comparison against neutronics and structural simulations. In conclusion, this experiment and the supporting simulations satisfied the following primary research goals for the STS target.

Dynamic strain response↗

Second Target Station Project: LANSCE WNR Target 2 (Blue Room) Experiment 2022

The Second Target Station (STS) at SNS will address emerging scientific challenges by providing a source of intense, cold neutrons to instruments optimized for this source, using rotating, tungsten target blocks. The STS target will receive 1.3 GeV proton beam pulses from the SNS accelerator at a repetition rate of 15 Hz. The facility life is planned for 40 years, and each target assembly life is expected to be approximately 10 years. An accurate strain prediction is then critical for fatigue life assessment of STS target blocks because they will be subject to approximately 108 beam pulses per lifetime. As an R&D activity, the LANSCE WNR Target 2 (blue room) facility was used to test the strain response of prototypical target blocks to the thermal shock of a proton pulse. The blue room was well suited for a pulsed proton beam impact test of subscale STS target blocks; the 800 MeV proton energy is approximately 60% of the 1.3 GeV proton energy expected from the SNS accelerator to the STS. Both the LANSCE Proton Storage Ring (PSR) and SNS are short-pulse proton beam sources with nominal pulse widths of 250 ns and 661 ns, respectively, so the energy deposition in the target occurs in < 1 microsecond pulse duration.

43 PARTICLE ACCELERATORS↗

Effective Dose Reduction to Cardiac Structures Using Protons Compared With 3DCRT and IMRT in Mediastinal Hodgkin Lymphoma

Purpose: We investigated the dosimetric impact of proton therapy (PT) on various cardiac subunits in patients with Hodgkin lymphoma (HL). Methods and Materials: From June 2009 through December 2010, 13 patients were enrolled on an institutional review board-approved protocol for consolidative involved-node radiotherapy (INRT) for HL. Three separate treatment plans were developed prospectively by using three-dimensional conformal radiotherapy (3DCRT), intensity-modulated radiotherapy (IMRT), and PT. Cardiac subunits were retrospectively contoured on the 11 patients with intravenous-contrast simulation scans, and the doses were calculated for all treatment plans. A Wilcoxon paired test was performed to evaluate the statistical significance (p < 0.05) of 3DCRT and IMRT compared with PT. Results: The mean heart doses were 21 Gy, 12 Gy, and 8 Gy (relative biologic effectiveness [RBE]) with 3DCRT, IMRT, and PT, respectively. Compared with 3DCRT and IMRT, PT reduced the mean doses to the left and right atria; the left and right ventricles; the aortic, mitral, and tricuspid valves; and the left anterior descending, left circumflex, and right circumflex coronary arteries. Conclusions: Compared with 3DCRT and IMRT, PT reduced the radiation doses to all major cardiac subunits. Limiting the doses to these structures should translate into lower rates of cardiac toxicities.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Dosimetric Comparison of Proton and Intensity-Modulated Photon Radiotherapy for Pediatric Parameningeal Rhabdomyosarcomas

Purpose: We compared tumor and normal tissue dosimetry of proton radiation therapy with intensity-modulated radiation therapy (IMRT) for pediatric parameningeal rhabdomyosarcomas (PRMS). Methods and Materials: To quantify dosimetric differences between contemporary proton and photon treatment for pediatric PRMS, proton beam plans were compared with IMRT plans. Ten patients treated with proton radiation therapy at Massachusetts General Hospital had IMRT plans generated. To facilitate dosimetric comparisons, clinical target volumes and normal tissue volumes were held constant. Plans were optimized for target volume coverage and normal tissue sparing. Results: Proton and IMRT plans provided acceptable and comparable target volume coverage, with at least 99% of the CTV receiving 95% of the prescribed dose in all cases. Improved dose conformality provided by proton therapy resulted in significant sparing of all examined normal tissues except for ipsilateral cochlea and mastoid; ipsilateral parotid gland sparing was of borderline statistical significance (p = 0.05). More profound sparing of contralateral structures by protons resulted in greater dose asymmetry between ipsilateral and contralateral retina, optic nerves, cochlea, and mastoids; dose asymmetry between ipsilateral and contralateral parotids was of borderline statistical significance (p = 0.05). Conclusions: For pediatric PRMS, superior normal tissue sparing is achieved with proton radiation therapy compared with IMRT. Because of enhanced conformality, proton plans also demonstrate greater normal tissue dose distribution asymmetry. Longitudinal studies assessing the impact of proton radiotherapy and IMRT on normal tissue function and growth symmetry are necessary to define the clinical consequences of these differences.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

L X-ray Intensity Ratios in Pb With Protons

Accelerators play a significant role in the investigation of inner-shell ionization. Inner-shell excitation through the impact of protons has shown renewed interest recently. These studies indicate that in the case of L-shell ionization, most of the experiments have been conducted with protons having energies greater than 500 keV. Thus, there is not only a lack of experimental data but there also exists large discrepancies between the experimental measurements and the theoretical calculations based on different models prevailing in this energy regime. In view of this, we report in this paper the experimentally measured values of L X-ray intensity ratios for Pb, namely, L{sub l}/L{sub {alpha}}, L{sub {beta}}/L{sub {alpha}} and L{sub {gamma}}/L{sub {alpha}} with protons over the energy range 225 keV-400 keV using a Van de Graaff accelerator. Their energy dependence and comparison with theoretical calculations will also be discussed. These measurements have yielded data in the low energy region, which helps in the emergence of better understanding of proton induced X-ray emission phenomenon.

74 ATOMIC AND MOLECULAR PHYSICS↗

Assessing the Clinical Impact of Approximations in Analytical Dose Calculations for Proton Therapy

Purpose: To assess the impact of approximations in current analytical dose calculation methods (ADCs) on tumor control probability (TCP) in proton therapy. Methods: Dose distributions planned with ADC were compared with delivered dose distributions as determined by Monte Carlo simulations. A total of 50 patients were investigated in this analysis with 10 patients per site for 5 treatment sites (head and neck, lung, breast, prostate, liver). Differences were evaluated using dosimetric indices based on a dose-volume histogram analysis, a γ-index analysis, and estimations of TCP. Results: We found that ADC overestimated the target doses on average by 1% to 2% for all patients considered. The mean dose, D95, D50, and D02 (the dose value covering 95%, 50% and 2% of the target volume, respectively) were predicted within 5% of the delivered dose. The γ-index passing rate for target volumes was above 96% for a 3%/3 mm criterion. Differences in TCP were up to 2%, 2.5%, 6%, 6.5%, and 11% for liver and breast, prostate, head and neck, and lung patients, respectively. Differences in normal tissue complication probabilities for bladder and anterior rectum of prostate patients were less than 3%. Conclusion: Our results indicate that current dose calculation algorithms lead to underdosage of the target by as much as 5%, resulting in differences in TCP of up to 11%. To ensure full target coverage, advanced dose calculation methods like Monte Carlo simulations may be necessary in proton therapy. Monte Carlo simulations may also be required to avoid biases resulting from systematic discrepancies in calculated dose distributions for clinical trials comparing proton therapy with conventional radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Proton irradiation effects on deep level states in Mg-doped p-type GaN grown by ammonia-based molecular beam epitaxy

The impact of proton irradiation on the deep level states throughout the Mg-doped p-type GaN bandgap is investigated using deep level transient and optical spectroscopies. Exposure to 1.8 MeV protons of 1 × 10{sup 13 }cm{sup −2} and 3 × 10{sup 13 }cm{sup −2} fluences not only introduces a trap with an E{sub V} + 1.02 eV activation energy but also brings monotonic increases in concentration for as-grown deep states at E{sub V} + 0.48 eV, E{sub V} + 2.42 eV, E{sub V} + 3.00 eV, and E{sub V} + 3.28 eV. The non-uniform sensitivities for individual states suggest different physical sources and/or defect generation mechanisms. Comparing with prior theoretical calculations reveals that several traps are consistent with associations to nitrogen vacancy, nitrogen interstitial, and gallium vacancy origins, and thus are likely generated through displacing nitrogen and gallium atoms from the crystal lattice in proton irradiation environment.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

An Examination of Proton Charge Radius Extractions from e–p Scattering Data

A detailed examination of issues associated with proton radius extractions from elastic electron–proton scattering experiments is presented. Sources of systematic uncertainty and model dependence in the extractions are discussed, with an emphasis on how these may impact the proton charge and magnetic radii. A comparison of recent Mainz data to previous world data is presented, highlighting the difference in treatment of systematic uncertainties as well as tension between different data sets. We find several issues that suggest that larger uncertainties than previously quoted may be appropriate, but do not find any corrections which would resolve the proton radius puzzle.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-E-T-201: Impact of Gantry and Table Angles On Proton Range in XiO Treatment Planning System

Purpose: To investigate if the selection of gantry and table angle has an impact on the calculated proton range (defined at the 90% distal falloff of the spread out Bragg peak) in XiO treatment planning system (TPS). Methods: A homogenous water phantom (40x40x40 cm{sup 3}) was constructed in XiO TPS. Ten treatment plans were generated using identical beam conditions (proton range = 25cm, modulation = 10cm) and device (10 cm diameter aperture) for various combinations of gantry (G) and table (T) angles (G0T90, G90T90, G180T90, G270T90, G90T0, G90T180, G90T270, G270T0, G270T180, and G270T270). The isocenter in each plan was selected at the center of the cubic target volume (5x5x5 cm{sup 3}) inside the phantom. All ten plans were calculated with pencil beam algorithm using a grid size of 3mm. The calculated proton ranges in all 10 plans were then compared against the prescribed (or expected) proton range, which was 25 cm in this study. Results: For all 10 treatment plans, calculated proton range was smaller when compared to the expected value (25cm), with XiO predicting the proton range from 24.62cm to 24.92cm. The difference between the prescribed and calculated proton range was highest (3.8mm) for plans with G90T270 and G270T90. Conclusion: Treatment plans generated in XiO TPS using G90T270 and G270T90 could produce a difference of more than 3 mm between the prescribed and calculated proton ranges. Further study using smaller dose calculation grid size (e.g., 1mm) is under progress to determine if the dose calculation grid size has any impact on the proton range. What causes the angle dependence of proton range calculation with the XiO TPS is also under investigation.

60 APPLIED LIFE SCIENCES↗

Long-term Measurements of Solar Proton Fluxes (1963-present) and the Subsequent Impact on Stratospheric Constituents

The fluxes of solar protons have been measured by satellites for over forty years (1963-present). Eight Interplanetary Monitoring Platform (IMP) satellites measured solar proton fluxes from 1963-1993 and five NOAA Geostationary Operational Environmental Satellites (GOES) were used for the period 1994present. These high energy solar protons precipitate on the Earth's polar atmosphere sporadically, especially during solar proton events (SPEs), which typically last a few days. Solar protons with energies greater than 30 MeV are capable of reaching the stratosphere and causing increases in odd hydrogen (HOx) and odd nitrogen (NOy) constituents at polar latitudes (greater than 60 degrees geomagnetic). The enhanced HOx leads to short-lived ozone depletion (-days) due to the short lifetime of HOx constituents. The enhanced NOy leads to long-lived ozone changes because of the long lifetime of the NOy family in the stratosphere. Several very large SPEs (August 1972, August and October 1989, July and November 2000, September and November 2001, and October 2003) over the 1963-2004 time period were simulated in the GSFC two-dimensional chemistry and transport model and were predicted to cause significant polar upper stratospheric ozone depletion greater than 10%, which lasted for several weeks past the events. Several satellite instruments (BUV, SBUV, SBW/2, SAGE II, HALOE, etc.) have shown constituent changes as a result of SPEs. Long-term (greater than 40 year) model simulations of the influence of the solar protons and satellite measurements during and after some of the very large SPEs will be shown.

Jackman, Charles H.↗

Mercury Handling for the Target System for a Muon Collider

The baseline target concept for a Muon Collider or Neutrino Factory is a free-stream mercury jet being impacted by an 8-GeV proton beam. The target is located within a 20-T magnetic field, which captures the generated pions that are conducted to a downstream decay channel. Both the mercury and the proton beam are introduced at slight downward angles to the magnetic axis. A pool of mercury serves as a receiving reservoir for the mercury and a dump for the unexpended proton beam. The impact energy of the remaining beam and jet are substantial, and it is required that splashes and waves be controlled in order to minimize the potential for interference of pion production at the target. Design issues discussed in this paper include the nozzle, splash mitigation in the mercury pool, the mercury containment vessel, and the mercury recirculation system.

43 PARTICLE ACCELERATORS↗

An Unbalanced Battle in Excellence: Revealing Effect of Ni/Co Occupancy on Water Splitting and Oxygen Reduction Reactions in Triple–Conducting Oxides for Protonic Ceramic Electrochemical Cells

Porous electrodes that conduct electrons, protons, and oxygen ions with dramatically expanded catalytic active sites can replace conventional electrodes with sluggish kinetics in protonic ceramic electrochemical cells. In this work, a strategy is utilized to promote triple conduction by facilitating proton conduction in praseodymium cobaltite perovskite through engineering non-equivalent B-site Ni/Co occupancy. Surface infrared spectroscopy is used to study the dehydration behavior, which proves the existence of protons in the perovskite lattice. The proton mobility and proton stability are investigated by hydrogen/deuterium (H/D) isotope exchange and temperature-programmed desorption. It is observed that the increased nickel replacement on the B-site has a positive impact on proton defect stability, catalytic activity, and electrochemical performance. This doping strategy is demonstrated to be a promising pathway to increase catalytic activity toward the oxygen reduction and water splitting reactions. The chosen PrNi 0.7 Co 0.3 O 3–δ oxygen electrode demonstrates excellent full-cell performance with high electrolysis current density of –1.48 A cm –2 at 1.3 V and a peak fuel-cell power density of 0.95 W cm –2 at 600 °C and also enables lower-temperature operations down to 350 °C, and superior long-term durability.

08 HYDROGEN↗