Search NASA⌕ Search

SEARCH · Search NASA

Results for “PSI”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Stochastic Microgrid Scheduling With Chance‐Constrained Resilience Consideration

Traditionally, it is assumed that microgrids transition seamlessly from grid‐connected operation to islanded mode in the event of sudden main grid outages. In reality, the islanding process, especially unintentional islanding, is rarely seamless. Instead, it is subject to voltage and frequency fluctuations caused by the instantaneous disconnection of the point of common coupling (PCC) switch, variations in loads and renewable generation output and even the protection tripping of distributed energy resources (DERs). To mitigate these fluctuations and facilitate a smooth islanding process, we propose a stochastic microgrid scheduling model that incorporates chance‐constrained resilience measures. Specifically, the resilience measure is defined as the probability of successful islanding (PSI), that is, the probability that a microgrid can mitigate the generation‐demand imbalance caused by the disconnection of the PCC switch, variations in load and renewable generation and DER tripping. This measure is modelled using chance constraints. Unlike existing reliability and resilience indices, which typically neglect the possibility of microgrid/DER failure under extreme events and assume their survival while primarily focussing on reducing impact duration or magnitude, the proposed PSI‐based framework explicitly addresses microgrid and DER survival during the islanding transition. The formulated nonlinear chance constraints are approximated using a multiinterval approach and equivalently represented as a mixed‐integer linear programming (MILP) formulation. Case study results validate the proposed method, showing that the PSI estimation error is reduced to less than 8%, compared to approximately 28% with existing methods. Various sensitivity analyses on the DER tripping rate and PSI settings were performed to validate the robustness of the proposed method. In particular, the necessity of accounting for DER tripping in the PSI calculation was demonstrated.

chance constrained optimization↗

Spectroscopic Studies of a Photosystem I - Hydrogenase Chimera

Our project, working with Kevin Redding at Arizona State University, aimed to overcome the O 2 inactivation of [FeFe] hydrogenase that stymies high-efficiency hydrogen conversion as tied to light-driven proton reduction in a PSI chimera. The HydA from Megasphaera elsdenii was shown to have much better oxygen tolerance; therefore a psaC-MeHydA chimera was constructed in which N-terminal ferredoxin-like domain of the MeHydA replaced the PsaC domain of PSI. The resulting chimeric protein assembles on PSI, accumulates in vivo to ~30% wild-type PSI levels as indicated by Chl/P700 ratio of the thylakoid, and make H 2 in a light-dependent fashion. In vitro spectroscopic characterization of PSI-MeHydA chimera was performed.

08 HYDROGEN↗

Evaluation of materials for sliding at 600F-1800F in air.

Oscillating sliding tests were conducted in air under the following operating conditions: 500 psi, 600 F; 500 psi, 1200 F; 500 psi, 1800 F; 1500 psi, 1800 F; 3000 psi, 1800 F. Sixteen materials combinations were tested including ceramics, alloys and eutectics, cermets, and combinations of these. Friction, wear and surface damage (including surface roughening) were studied. The most outstanding materials combination was found to be nickel-molybdenum-bonded titanium carbide cermet sliding against dense magnesia stabilized ZrO2.

Finkin, E. F.↗

Testing of polyimide second-stage rod seals for single-state applications in advanced aircraft hydraulic systems

Machined polyimide second-stage rod seals were evaluated to determine their suitability for single-stage applications where full system pressure acts on the upstream side of the seal. The 6.35-cm (2.5-in.) K-section seal was tested in impulse screening tests where peak pressure was increased in 3.448-MPa (500-psi) increments each 20,000 cycles. Seal failure occurred at 37.92 MPa (5,500 psi), indicating a potential for acceptability in a 27.58-MPa (4,000-psi) system. Static pressurization for 600 sec at pressures in excess of 10.34 MPa (1,500 psi) revealed structural inadequacy of the seal cross section to resist fracture and extrusion. Endurance testing showed the seals capable of at least 65,000 1.27-cm (0.5-in.) cycles at 450 K (350 F) without leakage. It was concluded that the second-stage seals were proven to be exceptional in the 1.379-MPa (200-psi) applications for which they were designed, but polyimide material properties are not adequate for use in this design at pressure loading equivalent to that present in single-stage applications.

Waterman, A. W.↗

Compound hydraulic shear-modulated vortex amplifiers

A novel two-stage shear-modulated hydraulic vortex amplifier (U.S. patent 3,520,317) has been fabricated and put through preliminary steady-state testing at the 1000 psi supply pressure level with flows up to 15 gpm. The invention comprises a conventional fluidic vortex power stage and a shear-modulated pilot stage. In the absence of any mechanical moving parts, water may be used as the hydraulic medium thus opening the way to many underseas applications. At blocked load, a control input from 0 to 150 psi was required to achieve an output from 0 to 900 psi; at wide-open load, a control input of 0 to 120 psi was needed to achieve an output from 0 to 15 gpm. The power stage has been found unsuitable for the proportional control mode because of its nonlinear performance in the intermediate load range and because of strong pressure fluctuations (plus or minus 150 psi) in the intermediate control range. The addition of the shear-modulated pilot stage improves intermediate load linearity.

Goldschmied, F. R.↗

Excitation of the Earth's Chandler wobble by southern oscillation/El Nino, 1900-1979

The southern oscillation/El Nino (ENSO) is the single most prominent interannual signal in global atmospheric/oceanic fluctuations. The following question is addressed: how important is the angular momentum carried by ENSO in exciting the Earth's Chandler wobble? The question is attacked through a statistical analysis of the coherence spectra (correlation as a function of frequency) between two data sets spanning 1900 to 1979-the southern oscillation index (SOI) time series and the excitation function psi (with x-component psi sub x and y-component psi sub y) of the Chandler wobble derived from the homogeneous ILS (International Latitude Service) polar motion data. The coherence power and phase in the Chandler frequency band (approx. 0.79 to 0.89 cpy) are studied. It is found that, during 1900 to 1979 the coherence between SOI and psi sub x is significant well over the 95% confidence threshold whereas that between SOI and psi sub y is practically nil. Quantitatively, the coherence study shows that ENSO provides some 20% of the observed Chandler wobble excitation power. Since earlier investigations have shown that the total atmospheric/oceanic variation can account for the Chandler wobble excitation at about 20% level, the implication is that ENSO maybe an important (interannual) part of the atmospheric/oceanic variation that is responsible for the Chandler wobble excitation during 1900 to 1979.

Chao, B. F.↗

Internal Luminosity Distribution of Bright Gamma-Ray Bursts and its Relation to Duration and Spectral Hardness

We present first results from a comprehensive investigation into the distribution of luminosity within the 50 brightest cosmic gamma-ray bursts detected by the Burst and Transient Source Experiment (BATSE). The internal luminosity function psi(L) is defined such that the quantity psi(L)dL represents the fraction of total emission time during which the burst possesses a luminosity between L and L + dL. For these brightest bursts, the psi(L) functions are quasi-power-law-like and decrease in amplitude with increasing luminosity. Through investigation of both individual psi(L) distributions and data from the ensemble of bursts, we demonstrate a high probability for correlation between the shape of the internal luminosity function as measured by the average logarithmic slope and the burst duration as measured by the T(sub 90) parameter and, with lower significance, between the shape of psi(L) and the burst photon-fluence spectral index. We furthermore demonstrate a correlation between burst hardness ratio and duration in these brightest bursts which is opposite to that of the entire gamma-ray burst ensemble.

Horack, John M.↗

CO2 Accumulation in the Non-Conformal Helmet of the NASA Launch and Entry Suit During Simulated Unaided Egress

The Launch and Entry Suit (LES) has been worn by astronauts since 1988 for Space Shuttle launch and landing. Previous work indicated that carbon dioxide (CO2) accumulation in the LES non-conformal helmet might be high during locomotion while wearing the LES. The purpose of this study was to characterize the inspired CO2%, metabolic requirements, and egress performance during a simulation of an unaided egress from the Space Shuttle in healthy male subjects wearing the LES and walking on a treadmill. With the helmet visor closed, 12 male subjects completed a 6-min seated prebreathe with 100% O2 followed by a 2-min stand and 5 min of walking at 1.56 m/sec (5.6 km/h, 3.5 mph) as a simulation of unaided egress. All subjects walked with four different G-suit pressures (0.0, 0.5, 1.0, 1.5 psi). After a 10-min recovery, subjects walked 5 min with the same G-suit pressure and helmet visor open for the measurement of metabolic rate (VO2). When G-suit inflation levels were 1.0 or 1.5 psi, only 4 of our 12 healthy, non-micro-gravity exposed subjects completed the unaided egress. Inspired CO2 levels greater than 4% were routinely observed during walking. The metabolic cost at the 1.5 psi G-suit inflation was over 135% of the metabolic cost at 0.0 psi inflation. During unaided egress, G-suit inflation pressures of 1.0 (required inflation for missions greater than 11 days) and 1.5 psi resulted in elevated CO2 in the LES helmet and increased metabolic cost of walking, either of which could impact unaided egress by returning space flight crews.

Greenisen, M. C.↗

Numerical Model of the Plasma Sheath Generated by the Plasma Source Instrument Aboard the Polar Satellite

The plasma sheath generated by the operation of the Plasma Source Instrument (PSI) aboard the POLAR satellite is studied by using a 3-dimensional Particle-In-Cell (PIC) code. When the satellite passes through the region of low density plasma, the satellite charges to positive potentials as high as 4050Volts due to the photoelectrons emission. In such a case, ambient core ions cannot accurately be measured or detected. The goal of the onboard PSI is to reduce the floating potential of the satellite to a sufficiently low value so that the ions in the polar wind become detectable. When the PSI is operated, an ion-rich Xenon plasma is ejected from the satellite, such that the floating potential of the satellite is reduced and is maintained at about 2Volts. Accordingly, in our 3-dimensional PIC simulation, we considered that the potential of the satellite is 2Volts as a fixed bias. Considering the relatively high density of the Xenon plasma in the sheath (approx. 10 - 10(exp 3)/cc), the ambient plasma of low density (less than 1/cc) is neglected. In the simulations, the electric fields and plasma dynamics are calculated self-consistently. We found that an "Apple" shape positive potential sheath forms surrounding the satellite. In the region near the PSI emission, a high positive potential hill develops. Near the Thermal Ion Detection Experiment (TIDE) detector away from the PSI, the potentials are sufficiently low for the ambient polar wind ions to reach it. In the simulations, it takes about a hundred electron gyroperiods for the sheath to reach a quasi-steady state. This time is approximately the time taken by the heavy Xe(+) ions to expand up to about one average Larmor radius of electrons from the satellite surface. Using the steady state sheath, we performed trajectory calculations to characterize the detector response to a highly supersonic polar wind flow. The detected ions' velocity distribution shows significant deviations from a shifted Maxwellian in the ambient polar wind population. The deviations are caused by the effects of electric fields on the ions' motion as they traverse the sheath.

Leung, Wing C.↗

Numerical Model of the Plasma Sheath Generated by the Plasma Source Instrument Aboard the Polar Satellite

The plasma sheath generated by the operation of the Plasma Source Instrument (PSI) aboard the Polar satellite is studied by using a three-dimensional particle-in-cell (PIC) code. When the satellite passes through the region of low-density plasma, the satellite charges to positive potentials as high as 40-50 V, owing to the photoelectron emission. In such a case, ambient core ions cannot accurately be measured or detected. The goal of the onboard PSI is to reduce the floating potential of the satellite to a sufficiently low value so that the ions in the polar wind become detectable. When the PSI is operated, ion-rich xenon plasma is ejected from the satellite, such that the floating potential of the satellite is reduced and is maintained at approximately 2 V. Accordingly, in our three-dimensional PIC simulation we considered that the potential of the satellite is 2 V as a fixed bias. Considering the relatively high density of the xenon plasma in the sheath (10-10(exp 3)/cc), the ambient plasma of low density (<1/cc) is neglected. In the simulations the electric fields and plasma dynamics are calculated self-consistently. We found that an 'apple'-shape positive potential sheath forms surrounding the satellite. In the region near the PSI emission a high positive potential hill develops. Near the Thermal Ion Dynamics Experiment detector away from the PSI, the potentials are sufficiently low for the ambient polar wind ions to reach it. In the simulations it takes only about a couple of tens of electron gyroperiods for the sheath to reach a quasi steady state. This time is approximately the time taken by the heavy Xe(+) ions to expand up to about one average Larmor radius of electrons from the satellite surface. After this time the expansion of the sheath in directions transverse to the ambient magnetic field slows down because the electrons are magnetized. Using the quasi steady sheath, we performed trajectory calculations to characterize the detector response to a highly supersonic polar wind flow. The detected ions' velocity distribution shows significant deviations from a shifted Maxwellian in the ambient polar wind population. The deviations are caused by the effects of electric fields on the ions' motion as they traverse the sheath.

Singh, N.↗

Brassica rapa plants adapted to microgravity with reduced photosystem I and its photochemical activity

The photosynthetic apparatus contains several protein complexes, many of which are regulated by environmental conditions. In this study, the influences of microgravity on PSI and PSII in Brassica rapa plants grown aboard the space shuttle were examined. We found that Brassica plants grown in space had a normal level of growth relative to controls under similar conditions on Earth. Upon return to Earth, cotyledons were harvested and thylakoid membranes were isolated. Analysis of chlorophyll contents showed that the Chl a/b ratio (3.5) in flight cotyledons was much higher than a ratio of 2.42 in the ground controls. The flight samples also had a reduction of PSI complexes and a corresponding 30% decrease of PSI photochemical activity. Immunoblotting showed that the reaction centre polypeptides of PSI were more apparently decreased (e.g. by 24-33% for PsaA and PsaB, and 57% for PsaC) than the light-harvesting complexes. In comparison, the accumulation of PSII complex was less affected in microgravity, thus only a slight reduction in D1, D2 and LHCII was observed in protein blots. However, there was a 32% decrease of OEC1 in the flight samples, indicating a defective OEC subcomplex. In addition, an average 54% increase of the 54 kDa CF1-beta isoform was found in the flight samples, suggesting that space-grown plants suffered from certain stresses, consistent with implications of the increased Chl a/b ratio. Taken together, the results demonstrated that Brassica plants can adapt to spaceflight microgravity, but with significant alterations in chloroplast structures and photosynthetic complexes, and especially reduction of PSI and its activity.

Non-NASA Center↗

Constraints on the Emission and Viewing Geometry of the Transient Anomalous X-ray Pulsar XTE J1810-197

The temporal decay of the flux components of the transient anomalous X-ray pulsar XTE J1 810-197 following its 2002 outburst presents a unique opportunity to probe the emission geometry of a magnetar. Toward this goal, we model the magnitude of the pulsar's modulation in narrow spectral bands over time. Following previous work, we assume that the postoutburst flux is produced in two distinct thermal components arising from a hot spot and a warm concentric ring. We include general relativistic effects on the blackbody spectra due to gravitational redshift and light bending near the stellar surface, which strongly depend on radius. This affects the model fits for the temperature and size of the emission regions. For the hot spot, the observed temporal and energy-dependent pulse modulation is found to require an anisotropic, pencil-beamed radiation pattern. We are able to constrain an allowed range for the angles that the line of sight (psi) and the hot spot pole (xi) make with respect to the spin axis. Within errors, this is defined by the locus of points in the xi-psi plane that lie along the line [xi + beta(R)] [psi + [beta(R)] = const, where beta(R) is a function of the radius R of the star. For a canonical value of R = 12 km, the viewing parameters range from psi = xi = 37deg to (psi, xi) = (85deg, 15deg). We discuss our results in the context of magnetar emission models.

Perna, Rosalba↗

Method for Impeding Degradation of Porous Silicon Structures

This invention relates to surface modification of porosified silicon (pSi) structures with poly(alkylene) glycols for the purpose of controlled degradation of the silicon matrix and tailored release of encapsulated substances for biomedical applications. The pSi structures are currently used in diverse biomedical applications including bio-molecular screening, optical bio-sensoring, and drug delivery by means of injectable/orally administered carriers and implantable devices. The size of the pores and the surface chemistry of the pSi structure can be controlled during the microfabrication process and thereafter. A fine regulation of the degradation kinetics of mesoporous silicon structures is of fundamental importance. Polyethylene glycols (PEGs) represent the major category of surface modifying agents used in classical drug delivery systems and in pharmaceutical dosage forms. PEGylation enables avoidance of RES uptake, thus prolonging circulation time of intravenously injectable nanovectors. PEG molecules demonstrate little toxicity and immunogenicity, and are cleared from the body through the urine (molecular weight, MW less than 30 kDa) or in the feces (MW greater than 30kDa). The invention focuses on the possibility of finely tuning the degradation kinetics of the pSi nanovectors and other structures through surface conjugation of PEGs with various backbone lengths/MWs. To prove the concept, pSi nanovectors were covalently conjugated to seven PEGs with MW from 245 to 5,000 Da and their degradation kinetics in physiologically relevant media (phosphate buffer saline, PBS pH7.4, and fetal bovine serum) was assessed by the elemental analysis of the Si using inductive coupled plasma atomic emission spectroscopy (ICP-AES). The conjugation of the PEG with lowest MW to the nanovectors surface did not induce any change in the degradation kinetics in serum, but inhibited degradation and consequently the release of orthosilicic acid into buffer. When PEGs with the longer chains were evaluated, Si mass loss from the nanovectors was slowed down, and the PEGylated structures were almost fully degraded within 18 24 hours in serum and within 48 hours in PBS. The most dramatic effect was observed for high MW PEGs 3,400 and 5,000 Da, which prominently inhibited the degradation of the systems, with complete degradation achieved only after four days. For these PEGs, during the early stages of the degradation, there was a lag period of little or no Si mass loss from the nanovector. The obtained profiles were in agreement with the erosion of the nanovector surface as observed by scanning electron microscopy.

Vilentchouk, Biana Godin↗

Ambulation Increases Decompression Sickness in Spacewalk Simulations

Musculoskeletal activity has the potential to both improve and compromise decompression safety. Exercise enhances inert gas elimination during oxygen breathing prior to decompression (prebreathe), but it may also promote bubble nuclei formation (nucleation), which can lead to gas phase separation and bubble growth and increase the risk of decompression sickness (DCS). The timing, pattern and intensity of musculoskeletal activity and the level of tissue supersaturation may be critical to the net effect. Understanding the relationships is important to evaluate exercise prebreathe protocols and quantify decompression risk in gravity and microgravity environments. Data gathered during NASA's Prebreathe Reduction Program (PRP) studies combined oxygen prebreathe and exercise followed by low pressure (4.3 psi; altitude equivalent of 30,300 ft [9,235 m]) microgravity simulation to produce two protocols used by astronauts preparing for extravehicular activity. Both the Phase II/CEVIS (cycle ergometer vibration isolation system) and ISLE (in-suit light exercise) trials eliminated ambulation to more closely simulate the microgravity environment. The CEVIS results (35 male, 10 female) serve as control data for this NASA/Duke study to investigate the influence of ambulation exercise on bubble formation and the subsequent risk of DCS. METHODS Four experiments will replicate the CEVIS exercise-enhanced oxygen prebreathe protocol, each with a different exception. The first of these is currently underway. Experiment 1 - Subjects complete controlled ambulation (walking in place with fixed cadence and step height) during both preflight and at 4.3 psi instead of remaining nonambulatory throughout. Experiment 2 - Subjects remain non-ambulatory during the preflight period and ambulatory at 4.3 psi. Experiment 3 - Subjects ambulate during the preflight period and remain non-ambulatory at 4.3 psi. Experiment 4 - The order of heavy and light exercise employed in the CEVIS protocol is reversed, with the light exercise occurring first (subjects remain non-ambulatory throughout). Decompression stress is assessed with non-invasive ultrasound during each of 14 epochs of a 4 hour simulated spacewalk at 4.3 psi; aural Doppler is used to monitor bubbles (Spencer grade 0-IV scale) passing through the pulmonary artery, and two-dimensional echocardiographic imaging is used to look for left ventricular gas emboli (LVGE; the presence of which is a test termination criterion). Venous blood is collected at baseline and twice following repressurization to determine if the decompression stress is correlated with microparticles (cell fragments) accumulation. The plan is to test 25-50 subjects in each experiment. Fisher Exact Tests (one-tailed) are used to compare test and control groups. Trials are suspended when the DCS or grade IV VGE observations reach 70% confidence of DCS risk >15% and grade IV VGE risk >20%. RESULTS Experiment 1 was concluded with 20 complete trials (15 male, 5 female) since the statistical outcome would not change with five additional trials. The observed DCS was significantly greater in Experiment 1 than in CEVIS trials (4/20 [20%] vs. 0/45 [0%], respectively, p=0.007), as was the frequency of peak grade IV VGE (6/21 [29%; including one additional subject that presented grade IV VGE but whose trial was ended before completion when LVGE were observed] vs. 3/45 [7%], respectively, p=0.024). Experiment 3 trials are now underway, with 11 trials completed (10 male, 1 female). Preliminary results indicate no difference in observed DCS between Experiment 3 and CEVIS trials (1/11 [9%] vs. 0/45 [0%], respectively, p=0.196), or between Experiment 3 and Experiment 1 trials (p=0.405). The frequency of peak grade IV VGE in Experiment 3 (2/11 [18%]) did not differ from CEVIS or Experiment 1 trials (p=0.251 and p=0.425, respectively). Microparticle patterns are widely variable and still under analysis. DISCUSSION The results of the Experiment 1 trials support the thesis that decompression stress is increased by ambulation exercise, given the higher incidence of DCS and grade IV VGE when compared to the non-ambulatory PRP CEVIS trials. Experiment 3 trials are incomplete, but suggest that the effect of ambulation during ground level preflight oxygen breathing alone, when subjects are undersaturated with inert gas, may not differ in risk from ambulation at both preflight and spacesuit pressures, the latter when subjects are supersaturated with inert gas. Further trials are needed to confirm the relative effects of ambulation in undersaturated vs. supersaturated states and to determine whether light exercise facilitates the removal of heavy exercise-induced nucleation (Experiment 4).

Pollock, N. W.↗

Novel High Temperature Capacitive Pressure Sensor Utilizing SiC Integrated Circuit Twin Ring Oscillators

This paper describes initial development and testing of a novel high temperature capacitive pressure sensor system. The pressure sensor system consists of two 4H-SiC 11-stage ring oscillators and a SiCN capacitive pressure sensor. One oscillator has the capacitive pressure sensor fixed at one node in its feedback loop and varies as a function of pressure and temperature while the other provides a pressure-independent reference frequency which can be used to temperature compensate the output of the first oscillator. A two-day repeatability test was performed up to 500C on the oscillators and the oscillator fundamental frequency changed by only 1. The SiCN capacitive pressure sensor was characterized at room temperature from 0 to 300 psi. The sensor had an initial capacitance of 3.76 pF at 0 psi and 1.75 pF at 300 psi corresponding to a 54 change in capacitance. The integrated pressure sensor system was characterized from 0 to 300 psi in steps of 50 psi over a temperature range of 25 to 500C. The pressure sensor system sensitivity was 0.113 kHzpsi at 25C and 0.026 kHzpsi at 500C.

high temperature↗

Development and Testing of Pulse Guns for Combustion Instability Testing

To test liquid rocket engines (LREs) for combustion instabilities, devices such as bombs are often used to create pressure wave disturbances. Bombs, while effective, are inherently dangerous, expensive, and difficult to procure. Over the years, pulse guns have been used as a safer and more cost-effective way to generate controlled pressure disturbances in engine chambers. In anticipation of the need for stability testing of prototype LREs at NASA Marshall Space Flight Center (MSFC), a set of pulse guns have been designed, fabricated, tested, and characterized. The pulse gun program is funded by the RS-25 Engine Program managed out of MSFC and funded by NASA’s Space Launch System (SLS) through the MSFC Liquid Engines Office (LEO). A pulse gun is a simple device – like a traditional gun, it has a breech and barrel section. However, unlike a traditional gun, there is no bullet, as the purpose of the pulse gun is strictly to fire a high pressure pulse. Instead of a firing pin and primer that would normally be used in a traditional gun, an initiator is used to activate the gun powder. The initiator is a highly reliable pyrotechnic initiator. For this study, clone versions of the NASA Standard Initiator (NSI) were used. The initiator is used to ignite a pre-measured amount of gun powder loaded into the breech. When the pressure of the burnt gun powder exceeds the set point of a downstream burst disk, the disk ruptures, allowing the high pressure pulse to travel downstream through the barrel section. A ballistic pressure transducer located in the breech section is used to measure the short duration, high pressure pulse. Some configurations of the pulse gun have barrel sections that include one or more additional ballistic pressure transducers. These additional pressure measurements help track the degradation and damping of the pulse as it travels out of the barrel section. The measurements may also be used to determine the velocity of pulse. The objective of this paper is to present the different variants of this newly-developed pulse gun and characterize performance over a range of parameters. The parameters include breech diameter, barrel length, amount of gun powder used, the way the gun powder is packed, and the pressure setting of the burst disk. There are a total of six pulse guns: three with the 0.25 inch breech and three different length barrels, and three with the 0.40 inch breech and three different length barrels. For both breech sizes, the associated barrels are referred to as standard, one-port, and two-port barrels. The standard barrel has no instrumentation and is likely the barrel that will be used for engine stability testing. The one- and two-port barrels were designed specifically for pulse gun component testing to allow measurements of the magnitude and timing of the high pressure pulse as it makes its way through the pulse gun. The burst disks tested were commercially-available burst disks designed to rupture at 8,000, 16,000, and 24,000 psid. Testing was accomplished by firing the pulse gun into a test chamber pressurized with nitrogen at about 2300 psig. A total of four Model 113B23 High frequency ICP® pressure sensors (10k psi) were mounted in the test chamber, in the same plane as the pulse gun. Two of the sensors had “trimmed” adapters, and two did not. Given the symmetrical configuration of the sensors within the test chamber, different amplitudes of pressure measurements are attributed to the use of trimmed versus untrimmed adapters. The untrimmed adapters, with their narrower passages, tended to amplify the pressure amplitudes by as much as 50%. In total, 41 pulse gun tests have been conducted.Data are still being analyzed, but some trends are apparent. For example, measurements taken within the pulse gun are shown in Figures 3 and 4 for Hot-fires (HFs) # 11 and 39, respectively. Both tests were identical in that the 0.40 inch ID breech, two-port barrel, 8,000 psid burst disk, and same amount of gunpowder (6.639 grains for HF# 11, and 6.576 grains for HF# 39) were used, and the back pressure in the nitrogen test chamber was ~2300 psig. Despite keeping all these variables constant, the results from these two tests look quite different. For both tests, the first pressure peak shown in the P2111 trace within the breech is the firing of the initiator. The second peak and any subsequent peaks are from the combustion of the gunpowder. It should be noted that because the sensors are dynamic, the ~2300 psig baseline static pressure is not shown in the figures. For HF# 11, the burst disk clearly ruptured in a little over 0.1 ms from the time the initiator was fired. This is evident from the abrupt rise in pressure for P2112 followed by another abrupt rise in pressure for P2113. The sensors track the movement of the high pressure pulse through the pulse gun. For HF# 39, however, there was nearly 1 ms delay between the initiator firing and the burst disk rupturing. The only difference between these two tests was the way in which the gunpowder was packed within the breech. For HF# 11, the gunpowder was poured directly into the breech, atop the initiator, and held in place with a vegetable fiber wad appropriately sized for the barrel diameter. Once in place, the wad firmly held the gunpowder in place. For HF# 39, the gunpowder was rolled within cigarette paper with the ends of the paper twisted. The rolled gunpowder was gently pushed down into the breech, toward the initiator, and no wad was used. This method of loading the gunpowder consistently produced longer delays in the rupture of the burst disk, presumably because there was a steady, fuller burning of the gunpowder. The burst disk was rated for 8,000 psid, which means that the burst disk should not have opened until the pressure in the breech reached ~10,300 since there was ~2300 psig back pressure in the test chamber. In the case of HF# 11, the breech pressure only reached roughly 4200 psi before there was leakage either through or past the burst disk, but for HF#39, the breech pressure reached 10,600 psi prior to the burst disk opening. The temperature of the burst disk is certainly a factor in determining when the burst disk will rupture. A sharp rise in the burst disk temperature could weaken it and cause it to stray from the designed set point burst pressure. The burst disks are manufactured of Inconel to try to reduce their sensitivity to temperature, but how the burst disks perform above 900°F is not documented. All burst disks were engineered and tested by the manufacturer for ambient temperature conditions. One theory for why rolling the gunpowder in cigarette paper may produce better results is related to a more controlled temperature environment. The cigarette paper may act as a sheath that protects the burst disk from excessive temperatures during the rapid buildup of pressure in the breech. The ultimate benefit of not breeching the burst disk prematurely is shown in Figures 5 and 6, which graphs the resultant pressure pulse produced in the test chamber. For HF #11, the peak pressure on the P2123 trimmed adapter is about 270 psi, while for HF# 39 it is 343 psi, which is about 1.27 times greater in magnitude. In either case, the pressure pulse is ~20 μs in width once it reaches the test chamber. Another pressure rise about 100 μs later can be seen on the sensors located across from the pulse gun port, P2124 and P2121. These pressures are lower due to attenuation of the pressure wave as it moves across the test chamber. After the wave encounters the wall, it reflects back and forth within the chamber until it completely dissipates.

Pulse Gun↗

Overview of the Predictive Simulation Capability Element of the Plume Surface Interaction Project

As part of the Game Changing Development (GCD) Program, funded by NASA’s Space Technology Mission Directorate (STMD), the development of simulation capability for the prediction of extra-terrestrial Plume Surface Interaction (PSI) environments has been undertaken by the Fluid Dynamics Branch at NASA/MSFC. The GCD PSI Project, planned to be completed over a four year period, contains a Predictive Simulation Capability (PSC) Element focused on creating simulation capability for the reliable and accurate prediction of PSI in Martian (~650 Pa) and Lunar (vacuum) ambient environments. In addition to the PSC Element, the GCD Program also contains a companion Ground Testing Element for development of focused datasets for validation of predictive capability as well as a Flight-focused Instrumentation Element. This paper describes the PSC Element of the PSI Project as well as providing descriptions of recent accomplishments and remaining work. The overall structure of the PSC Element is broken down into four areas of focus. The first area is the Prediction of Plume Flow in low pressure environments. The development approach taken is the augmentation of the existing production-mode computational fluid dynamics (CFD) tool Loci/Chem, with targeted extensions necessary to accurately model rarefied conditions found in both Martian and Lunar applications. Production readiness and validation of predictive capability are the major objectives of this task. The second area is the effect of mixed continuum/rarefied flow on crater development and ejecta sheets. A new CFD application, Loci/GGFS (Gas Granular Flow Solver), is being developed which implements an Eulerian/Eulerian two-phase model of gas- and soil-phases in order to simulate the soil erosion, crater formation, and soil ejecta transport in a fully coupled simulation. This task seeks to verify Loci/GGFS is production-ready as well as perform validation studies to determine the degree of predictive capability achieved by Loci/GGFS. The third area is focused on the details and extension of particle phase modeling of soil. In this task, Discrete Element Modeling (DEM) techniques are used to perform direct simulations of complex soil particles under the action of forcing similar to that to be cause by PSI. The simulation results are then used to construct closures to the Eulerian model of the soil phase used by Loci/GGFS. The fourth area is gas-particle interaction modeling. In this task, experiments are being conducted as well as detailed simulation results are being studied to further understand the complexities of gas-particle interactions in dilute, intermediate, and high soil volume fraction regimes. Improved models of particle drag and the particle turbulent kinetic energy (PTKE) resulting from the interaction of gas flows within particle clouds are the objective of this task.

Jeff West↗

Simulating Underexpanded Jets in Martian and Lunar Environments

As part of the Game Changing Development (GCD) Program, funded by NASA’s Space Technology Mission Directorate (STMD), the development of simulation capability for the prediction of extra-terrestrial Plume Surface Interaction (PSI) environments has been undertaken by the Fluid Dynamics Branch at NASA/MSFC. The GCD PSI Project, planned to be accomplished over a four year period, contains a Predictive Simulation Capability (PSC) Element focused on creating simulation capability for the reliable and accurate prediction of PSI in Martian (~650 Pa) and Lunar (vacuum) ambient environments. In addition to the PSC Element, the PSI Project also contains a companion Ground Testing Element for development of focused datasets for validation of predictive capability as well as a Flight-focused Instrumentation Element. This paper describes the activities and accomplishments in the past year for the Prediction of Plume Flow in low pressure environments component of the PSI Project. While the Loci/Chem Computational fluid dynamics (CFD) application has been validated and used extensively for simulating launch environments in atmospheric conditions, use of this tool for simulating supersonic plumes at Mars-like ambient pressure requires further validation. CFD simulations of underexpanded jets have been performed using Loci/Chem for Mars-like conditions to predict several metrics for steady laminar, turbulent, and impinging plumes. The CFD results are compared with an experimental data set for low Reynolds number plumes at these conditions in order to evaluate the current capability of the Loci/Chem tool for these types of environments. The CFD validation results to date show reasonable agreement with the experimental data across all of the metrics of interest for the configurations considered. The Loci/Chem-Boltzmann CFD application is a hybrid continuum/rarefied flow solver which extends modeling capabilities to very low pressure environments such as those on the Moon. The Loci/Chem-Boltzmann solver uses a gradient-based continuum breakdown criterion to restrict solution of the computationally expensive Boltzmann equation to only a subset of the domain, while using the Navier-Stokes equations elsewhere. This CFD application is under active development, and current efforts toward establishing production ready capability for evaluating Lunar plume surface interactions are well under way. Initial simulations of an Apollo LEM indicate that several regions of the flow require solving the Boltzmann equations due to extreme rarefaction. Early simulations are promising, indicating reasonable overall computational time for a full 3D human scale lander simulation.

Thomas Shurtz↗