Search NASA⌕ Search

SEARCH · Search NASA

Results for “PULSE AMPLITUDE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Evaluation of the amperex 56 TVP photomultiplier

Characteristics were measured for the Amperex 56 TVP 42 mm-diameter photomultiplier. Some typical photomultiplier characteristics-such as gain, dark current, transit and rise times-are compared with data provided. Photomultiplier characteristics generally not available such as the single photoelectron time spread, the relative collection efficiency, the relative anode pulse amplitude as a function of the voltage between the photocathode and focusing electrode, and the position of the photocathode sensing area were measured and are discussed for two 56 TVP's. The single photoelectron time spread, the relative collection efficiency, and the transit time difference as a function of the voltage between photocathode and focusing electrode were also measured and are discussed, particularly with respect to the optimization of photomultiplier operating conditions for timing applications.

Lo, C. C.↗

Studies in astronomical time series analysis. I - Modeling random processes in the time domain

Several random process models in the time domain are defined and discussed. Attention is given to the moving average model, the autoregressive model, and relationships between and combinations of these models. Consideration is then given to methods for investigating pulse structure, procedures of model construction, computational methods, and numerical experiments. A FORTRAN algorithm of time series analysis has been developed which is relatively stable numerically. Results of test cases are given to study the effect of adding noise and of different distributions for the pulse amplitudes. A preliminary analysis of the light curve of the quasar 3C 272 is considered as an example.

Scargle, J. D.↗

Synchronization for Optical PPM Signals

Method based on statistical properties of weak pulse-positionmodulated (PPM) signal enables synchronization of receiver clock with received-signal time base. Method applies to weak optical M-ary PPM signals, for which there is only one pulse of length Tp transmitted during one of timeslots of length T in each successive interval of M timeslots. Method requires small dead time, Td, at beginning and end of each timeslot, during which pulse amplitude is zero.

Vilnrotter, V. A.↗

Transient vibration test criteria for spacecraft hardware

Transient vibration test criteria, developed for spacecraft hardware, provide a test rationale to verify the capability of the hardware to withstand the low and mid frequency transient vibration environments induced by launch vehicle events. A test method, consisting of a series of discrete frequency, limited cycle, modulated sine wave pulses, was developed to avoid the slow swept sine drawbacks, yet provide a repeatable test that would excite all frequencies. The shape of the waveform is that of the classic response of the mass of a one degree of freedom system when it is base-excited by an exponentially decayed sine wave transient. Criteria were developed to define pulse amplitudes, shapes, and center frequencies from spacecraft loads analyses. Test tolerance criteria were also developed and specified. The transient vibration test criteria were implemented on spacecraft flight hardware and provided a more realistic test simulation (i.e., less conservative) for qualification of spacecraft hardware without risk of undertest.

Kern, D. L.↗

Radiation effects induced in pin photodiodes by 40- and 85-MeV protons

PIN photodiodes were bombarded with 40- and 85-MeV protons to a fluence of 1.5 x 10 to the 11th power p/sq cm, and the resulting change in spectral response in the near infrared was determined. The photocurrent, dark current and pulse amplitude were measured as a function of proton fluence. Changes in these three measured properties are discussed in terms of changes in the diode's spectral response, minority carrier diffusion length and depletion width. A simple model of induced radiation effects is presented which is in good agreement with the experimental results. The model assumes that incident protons produce charged defects within the depletion region simulating donor type impurities.

Becher, J.↗

Sub-Optimal Control of Nonlinear Flexible Space Structures

A simple yet effective method is presented for the on-line vibration control of nonlinear distributed parameter systems, with constant or time-varying properties, responding to a wide class of dynamic environments. The control procedure uses pulse generators located at selected positions throughout a given system. The degree of system oscillation near each controller determines the controller's activation time and pulse amplitude. The direct method of Liapunov is used to establish that the response of the controlled nonlinear system is Lagrange stable. Analytical and experimental studies of a wing-like plate demonstrate the feasibility, reliability, and robustness of the proposed vibration-suppression method.

Dehghanyar, T. J.↗

Cosmic-ray backgrounds in infrared bolometers

Model calculations for the production of cosmic ray events in IR detectors by energy impulses due to fast charged particles' ionization trails are presently compared to the pulse-amplitude spectrum observed from a balloon at an altitude of 38 km. The results are pertinent to the current understanding of cosmic ray backgrounds found in all high sensitivity bolometer applications. The observed signal transients are in all details consistent with the modeling of known cosmic charged particle flux characteristics and with the detector response. Generally, the optics design should minimize detector/substrate cross section.

Nolt, I. G.↗

Photoelectronic Monitor of Motion Sickness

Instrument includes gallium arsenide light-emitting diode (LED) and silicon phototransistor with infrared filter, all cast in single plastic housing. Housing attached to subject's face with transparent doublesided adhesive tape. LED directs pulses of infrared light to skin, which reflects them to phototransistor. Phototransistor produces signal that is processed by external circuits to yield plot of infrared reflectance with time. External circuits temperature-compensated and respond only to pulsed component of detector output, rejecting those components caused by stray light. Circuits also extract blood-volume pulse amplitude and heart rate.

Oman, C. M.↗

PIN photodiodes irradiated with 40- and 85-MeV protons

PIN photodiodes were bombarded with 40- and 85-MeV protons to a fluence of 1.5 x 10 to the 11th p/sq cm, and the resulting change in spectral response in the near infrared was determined. The photocurrent, dark current, and pulse amplitude were measured as a function of proton fluence. Changes in these three measured properties are discussed in terms of changes in the diode's spectral response, minority carrier diffusion length, and depletion width. A simple model of induced radiation effects is presented which is in good agreement with the experimental results. The model assumes that incident protons produce charged defects within the depletion region simulating donor type impurities.

Reft, C. S.↗

Rapid variability of P Cygni lines in massive X-ray binaries

In early-type X-ray binaries, the recombination time scales for ions such as C IV, Si IV, and N V in the stellar winds of their massive OB companion stars can be very short compared to typical X-ray pulsation or fluctuation time scales. Thus, the authors predict that the 'bleached zones', in which these ions are removed from the stellar wind by X-ray photoionization, will track the X-ray beam as it rotates and that the P Cygni line profiles due to these ions will pulsate. With the IUE satellite the authors obtained low-resolution UV spectra of the binary X-ray system HD 77581/4U 0900-40 resolved into six phase bins of the 283 s pulse period; the observed upper limit to the pulse amplitude of the equivalent width of C IV 1550 A was less than the predicted value. However, the pulsations should be easy to observe with the Hubble Space Telescope.

Kallman, Timothy R.↗

A lower bound on the minimum Euclidean distance of trellis-coded modulation schemes

A lower bound on the minimum free Euclidean distance of trellis-coded modulation (TCM) is derived that guarantees the existence of good TCM codes of any complexity. The bound is used to compare trellis codes combined with phase-shift keying, pulse amplitude modulation, and quadrature amplitude-shift keying modulation. This random coding bound is the first lower bound on the free distance of trellis codes, is tighter than any upper bound for large constraint lengths, and predicts the asymptotic performance of TCM when the complexity of the code becomes large. The bound can be used with any code rate and any modulation scheme and shows that the free distance increases linearly with the constraint length for large values of the constraint length.

Rouanne, Marc↗

Propagation of high-power microwave pulses in air breakdown environment

A chamber experiment is conducted to study the propagation of high-power microwave pulses through the air. Two mechanisms responsible for two different degrees of tail erosion have been identified experimentally. The optimum pulse amplitude for maximum energy transfer through the air has also been determined.

Kuo, S. P.↗

Preliminary analysis of measured sound propagation over various seasonal snow covers

Measurements of acoustic pulse propagation in the 5 to 500-Hz frequency band were conducted under various snow cover conditions during the 1989 to 1990 winter in New Hampshire. The objective was to determine the effect of snow cover thickness and other snow properties on the absorption of acoustic pulses. Blank pistol shots were used as the source of the acoustic waves, and geophones and microphones in an 80 m-long linear array served as receivers. Snow thicknesses ranged from 0.05 to 0.35 m, and densities varied from 100 to 350 kg m(sup -3) during the 10 separate measurement days. Preliminary analysis indicates that the peak pulse amplitude decayed in proportion to approx. gamma (sup -1.7) for most conditions and that the acoustic-to-seismic ratios varied from about 4 to 15 x 10(exp -6) m s(sup -1) Pa(sup -1). Theoretical waveforms were calculated for propagation in a homogeneous atmosphere using Attenborough's model of ground impedance. An automatic fitting procedure for the normalized experimental and theoretical waveforms was used to determine the effective flow resistivity of the snow covers, and gave values of 10 to 35 kN s m(sup -4), in agreement with earlier results.

Albert, Donald G.↗

Soft x ray window encapsulant for HgI2 detectors

HgI2 is an excellent semiconductor material for a low energy, room temperature x-ray spectrometer. The high values of the atomic numbers for its constituent elements gives high x-ray and gamma ray stopping power. The band gap of HgI2 is significantly higher than other commonly used semiconductors. Owing to the large value band gap, the leakage current for HgI2 devices is smaller, thus allowing low noise performance. Devices fabricated from HgI2 crystals have demonstrated energy resolution sufficient to distinguish the x-ray emission from the neighboring elements on the periodic table. Also the power requirements of HgI2 are very low. These characteristics make a HgI2 spectrometer an ideal component in a satellite based detection system. Unfortunately, HgI2 crystals tend to deteriorate with time, even if protected by standard semiconductor encapsulants. This degradation ruins the performance of the device in terms of its energy resolution and pulse amplitude. The degrading mechanism is believed to be material loss occurring from below the electrodes, due to high vapor pressure of HgI2 at room temperature. To address this major obstacle to rapid expansion of HgI2 technology, a research program aimed at improving device stability by encapsulation with inert polymeric materials was carried out. The program focused specifically on optimizing the encapsulant materials and their deposition techniques. The principal objectives for this program were device encapsulation, device testing, and accelerated testing to ensure very long term stability of these high resolution sensors. A variety of encapsulants were investigated with the selection criteria based on their chemical diffusion barrier properties, mechanical stability, reactivity, and morphology of encapsulant films. The investigation covered different classes of encapsulants including solvent based encapsulants, vapor deposited encapsulants, and plasma polymerized encapsulants. A variety of characterization techniques were employed to examine their effectiveness in stabilizing HgI2 devices; these included permeability evaluation, vacuum and heat testing, scanning electron microscopy (SEM) as well as studying the detector performance of coated detectors. The plasma polymerized films appear to have entirely solved the HgI2 degradation problem. Another achievement of this program was the development of an accelerated testing technique which correlates extremely well with long term tesing.

Entine, G.↗

Digital data over video channels - Techniques for Spacelab

A study was made of various techniques for transmitting digital data over a composite video channel. Transmitting data from experiments on the Space Shuttle Orbiter over a video channel is attractive since extra channel capacity is needed. Broadcast television telecommunications schemes and other techniques described in the literature were reviewed and compared. PSK (Phase Shift Keying), MPSK (m-ary PSK), or PAM (Pulse Amplitude Modulation) can be transmitted on visible lines of a frame, unassigned lines of the VBI (Vertical Blanking Interval), or during the HBI (Horizontal Blanking Interval). All three modulation techniques can be attractive under the proper conditions. However, PAM on visible lines or during the VBI should be relatively easy to implement, provide adequate average data rates, and give acceptable BERs (Bit Error Rates).

Smith, Dean L.↗

Techniques for transmitting digital data on the Spacelab's analog video channel

A study was made of various techniques for transmitting digital data over a composite video channel. Transmitting data from experiments on the Space Shuttle Orbiter over a video channel is attractive since extra channel capacity is needed. Broadcast television telecommunications schemes and other techniques described in the literature were reviewed and compared. PSK (Phase Shift Keying), MPSK (m-ary PSK), or PAM (Pulse Amplitude Modulation) can be transmitted on visible lines of a frame, unassigned lines of the VBI (Vertical Blanking Interval), or during the HBI (Horizontal Blanking Interval). All three modulation techniques can be attractive under the proper conditions. However, PAM on visible lines or during the VBI should be relatively easy to implement, provide adequate average data rates, and give acceptable BERs (Bit Error Rates).

Smith, Dean L.↗

Digital modulation schemes for high speed transmission through low bandwidth lowpass analog links

Existing NTSC (National Television System Committee) standard will be phased out and replaced with HDTV (High Definition Television) standard within the next 10 years. Accordingly, the existing video network system operated by NASA will become obsolete and requires either replacement or modification to accommodate digital transmission. Network replacement is extremely expensive, hence, several digital modulation schemes are investigated in this report to accomplish digital transmission over existing analog links saving NASA from the cost of network replacement. There are two competing transmission systems available for HDTV transmission over limited bandwidth channels. The cost and performance of the two competing schemes are remarkably similar. However, the input data rate in such a case is limited to 40 Mbit/s. Transmission of higher data rates is possible using simple signal processing techniques. On the other hand, a third transmission system, multilevel pulse amplitude modulation (M-PAM) is proposed. M-PAM is the first stage of the well known M-VSB. This M-PAM scheme is much simpler and uses the channel more efficiently. The three schemes are compared and preliminary conclusions were made. Despite of several similarities, each modulation scheme has it unique merits. To determine the suitability of each scheme, more investigations and laboratory tests for all schemes are needed.

Andrawis, Alfred S.↗

Miniature High-Let Radiation Spectrometer for Space and Avionics Applications

This paper reports on the design and characterization of a small, low power, and low weight instrument, a High-LET Radiation Spectrometer (HiLRS), that measures energy deposited by heavy ions in microelectronic devices. The HILRS operates on pulse-height analysis principles and is designed for space and avionics applications. The detector component in the instrument is based on large scale arrays of p-n junctions. In this system, the pulse amplitude from a particle hit is directly proportional to the particle LET. A prototype flight unit has been fabricated and calibrated using several heavy ions with varying LETs and protons with several energies. The unit has been delivered to the Ballistic Missile Defense Organization (BMDO) c/o the Air Force Research Laboratory in Albuquerque, NM, for integration into the military Space Technology Research Vehicle (STRV), a US-UK cooperative mission. Another version of HILRS is being prepared for delivery in April to the Hubble Space Telescope (HST) project, to fly on the HST Orbital Systems Test (HOST) Platform on a shuttle mission.

Stassinopoulos, E. G.↗