Search NASA⌕ Search

SEARCH · Search NASA

Results for “PULSE AMPLITUDE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Local oscillator induced degradation of medium-term stability in passive atomic frequency standards

As the performance of passive atomic frequency standards improves, a new limitation is encountered due to frequency fluctuations in an ancillary local oscillator (L.O.). The effect is due to time variation in the gain of the feedback which compensates L.O. frequency fluctuations. The high performance promised by new microwave and optical trapped ion standards may be severely compromised by this effect. Researchers present an analysis of this performance limitation for the case of sequentially interrogated standards. The time dependence of the sensitivity of the interrogation process to L.O. frequency fluctuations is evaluated for single-pulse and double-pulse Ramsey RF interrogation and for amplitude modulated pulses. The effect of these various time dependencies on performance of the standard is calculated for an L.O. with frequency fluctuations showing a typical 1/f spectral density. A limiting 1/sq. root gamma dependent deviation of frequency fluctuations is calculated as a function of pulse lengths, dead time, and pulse overlap. Researchers also present conceptual and hardware-oriented solutions to this problem which achieve a much more nearly constant sensitivity to L.O. fluctuations. Solutions involve use of double-pulse interrogation; alternate interrogation of multiple traps so that the dead time of one trap can be covered by operation of the other; and the use of double-pulse interrogation for two traps, so that during the time of the RF pulses, the increasing sensitivity of one trap tends to compensate for the decreasing sensitivity of the other. A solution making use of amplified-modulated pulses is also presented which shows nominally zero time variation.

Dick, G. John↗

Pressure-Application Device for Testing Pressure Sensors

A portable pressure-application device has been designed and built for use in testing and calibrating piezoelectric pressure transducers in the field. The device generates pressure pulses of known amplitude. A pressure pulse (in contradistinction to a steady pressure) is needed because in the presence of a steady pressure, the electrical output of a piezoelectric pressure transducer decays rapidly with time. The device includes a stainless- steel compressed-air-storage cylinder of 500 cu cm volume. A manual hand pump with check valves and a pressure gauge are located at one end of the cylinder. A three-way solenoid valve that controls the release of pressurized air is located at the other end of the cylinder. Power for the device is provided by a 3.7-V cordless-telephone battery. The valve is controlled by means of a pushbutton switch, which activates a 5 V to +/-15 V DC-to-DC converter that powers the solenoid. The outlet of the solenoid valve is connected to the pressure transducer to be tested. Before the solenoid is energized, the transducer to be tested is at atmospheric pressure. When the solenoid is actuated by the push button, pressurized air from inside the cylinder is applied to the transducer. Once the pushbutton is released, the cylinder pressure is removed from the transducer and the pressurized air applied to the transducer is vented, bringing the transducer back to atmospheric pressure. Before this device was used for actual calibration, its accuracy was checked with a NIST (National Institute of Standards and Technology) traceable calibrator and commercially calibrated pressure transducers. This work was done by Wanda Solano of Stennis Space Center and Greg Richardson of Lockheed Martin Corp.

Source record↗

Focusing of Finite-Amplitude Cylindrical and Spherical Sound Waves in a Viscous and Heat-Conducting Medium

The focusing of acoustic pulses is studied analytically by considering the region of study in three parts: the converging, interaction and diverging regions. First, the linear problem of a pulse of infinitesimal amplitude is studied. For the spherical case, the expected phase change as a result of focusing is verified. The nonlinear case of finite-amplitude pulses leads to the development of M-waves, as determined by applying the method of matched-asymptotic expansions to Burges equation.

Chu, T.↗

Fiber-optic displacement sensor with temporally separated signal and reference channels

A fiber-optic displacement sensor with temporally separated signal and reference channels is proposed. The sensing technique used is based on determining the relative amplitude of the signal and reference pulses that together form a double pulse. The relative amplitude of the pulses in the double pulse is a function of the displacement. A setup to generate the double pulse with individual pulses of 5-ns duration and 10-ns delay is described. A novel signal processing technique, used to determine the relative amplitude of such pulses in the double pulse by analyzing different portions of the signal spectrum, is explained. Experimental data are also provided.

Adamovsky, Grigory↗

Prediction of blade-vortex interaction noise using measured blade pressures

In the study reported here, blade-vortex interaction noise was predicted using a simplified model of blade pressures measured on a one-seventh scale model AH-1/OLS main rotor. The methods used for the acoustic prediction are based on the acoustic analogy and have been developed by Nakamura (1981) and by Brentner, Nystrom, and Farassat (referred to as the WOPWOP method). The waveforms predicted by the two methods are in good agreement with each other and with the measurements in terms of the number of pulses, the pulse widths, and the separation times between the pulses. The peak amplitude of the dominant pulse may, however, be underpredicted by up to 40 percent, depending on flight conditions. Ways of improving the accuracy of the prediction methods are suggested.

Joshi, Mahendra C.↗

Smooth Phase Interpolated Keying

Smooth phase interpolated keying (SPIK) is an improved method of computing smooth phase-modulation waveforms for radio communication systems that convey digital information. SPIK is applicable to a variety of phase-shift-keying (PSK) modulation schemes, including quaternary PSK (QPSK), octonary PSK (8PSK), and 16PSK. In comparison with a related prior method, SPIK offers advantages of better performance and less complexity of implementation. In a PSK scheme, the underlying information waveform that one seeks to convey consists of discrete rectangular steps, but the spectral width of such a waveform is excessive for practical radio communication. Therefore, the problem is to smooth the step phase waveform in such a manner as to maintain power and bandwidth efficiency without incurring an unacceptably large error rate and without introducing undesired variations in the amplitude of the affected radio signal. Although the ideal constellation of PSK phasor points does not cause amplitude variations, filtering of the modulation waveform (in which, typically, a rectangular pulse is converted to a square-root raised cosine pulse) causes amplitude fluctuations. If a power-efficient nonlinear amplifier is used in the radio communication system, the fluctuating-amplitude signal can undergo significant spectral regrowth, thus compromising the bandwidth efficiency of the system. In the related prior method, one seeks to solve the problem in a procedure that comprises two major steps: phase-value generation and phase interpolation. SPIK follows the two-step approach of the related prior method, but the details of the steps are different. In the phase-value-generation step, the phase values of symbols in the PSK constellation are determined by a phase function that is said to be maximally smooth and that is chosen to minimize the spectral spread of the modulated signal. In this step, the constellation is divided into two groups by assigning, to information symbols, phase values that result in equal numbers of clockwise and counter-clockwise phase rotations for equally likely symbols. The purpose served by assigning phase values in this way is to prevent unnecessary generation of spectral lines and prevent net shifts of the carrier signal. In the phase-interpolation step, the smooth phase values are interpolated over a number, n, of consecutive symbols (including the present symbol) by means of an unconventional spline curve fit.

Borah, Deva K.↗

Electrical filtering in gerbil isolated type I semicircular canal hair cells

1. Membrane potential responses of dissociated gerbil type I semicircular canal hair cells to current injections in whole cell current-clamp have been measured. The input resistance of type I cells was 21.4 +/- 14.3 (SD) M omega, (n = 25). Around the zero-current potential (Vz = -66.6 +/- 9.3 mV, n = 25), pulsed current injections (from approximately -200 to 750 pA) produced only small-amplitude, pulse-like changes in membrane potential. 2. Injecting constant current to hyperpolarize the membrane to around -100 mV resulted in a approximately 10-fold increase in membrane resistance. Current pulses superimposed on this constant hyperpolarization produced larger and more complex membrane potential changes. Depolarizing currents > or = 200 pA caused a rapid transient peak voltage before a plateau. 3. Membrane voltage was able to faithfully follow sine-wave current injections around Vz over the range 1-1,000 Hz with < 25% attenuation at 1 kHz. A previously described K conductance, IKI, which is active at Vz, produces the low input resistance and frequency response. This was confirmed by pharmacologically blocking IKI. This conductance, present in type I cells but not type II hair cells, would appear to confer on type I cells a lower gain, but a much broader bandwidth at Vz, than seen in type II cells.

Non-NASA Center↗

Attributes of GRB Pulses: Analysis of BATSE TTE Data

Our extensive program of modeling GRB profiles is aimed at elucidating the physical processes responsible for the burst itself, as well as possible extrinsic phenomena (e.g. time dilation) as discussed in another paper in this Symposium (Norris et al., "GRB PROFILES AS COSMIC PROBES"). We have developed special methods to extract the wealth of short time-scale information contained in the BATSE time-tag event (TTE) data. Our algorithm yields a piecewise-constant representation of the light curve -- using only the raw photon arrival times, and based on Bayesian change-point methods. This representation in effect lets the data determine the bin size and location, and avoids unwanted effects due to arbitrary choices of the bin parameters. We have determined widths, separations, and amplitudes of pulses contained in the bursts, without invoking a specific pulse model. The effect of cosmic time dilation can be easily seen in a direct plot of amplitude vs. time scale for individual pulses, without the need to lump the data into a small number of brightness classes. We are also performing noise equalization on these data (to reduce a well-known bias of pulse width as a function of signal-to-noise ratio), as well as fits of parametric pulse-shape models -- including explicit energy dependence of the pulse parameters. Such refinements are expected to improve the quality and physical significance of these results.

Norris, J. P.↗

Thundercloud radio emission from cosmic-ray-shower ionization electrons

The drift of shower ionization electrons in thundercloud fields constitutes a traveling current pulse whose amplitude is modulated by shower development and by the thundercloud field. The radio emission from such a pulse is calculated for a simple modulation model. The response of electric dipole antennas to such pulses is evaluated. To distinguish shower ionization radio pulses from random noise, the use of two receiver bands centered at a common frequency is proposed. It is shown that the ratio of the power in the two bands can be used to distinguish shower ionization radio signals from random noise. For modulated current pulses traveling above the speed of light in a medium, an inverse modulation effect is found. For unmodulated current pulses traveling above the speed of light in a medium, a new class of realizations of the Cerenkov effect is discovered.

Tompkins, D. R., Jr.↗

Interactive signal analysis and ultrasonic data collection system user's manual

The interactive signal analysis and ultrasonic data collection system (ECHO1) is a real time data acquisition and display system. ECHO1 executed on a PDP-11/45 computer under the RT11 real time operating system. Extensive operator interaction provided the requisite parameters to the data collection, calculation, and data modules. Data were acquired in real time from a pulse echo ultrasonic system using a Biomation Model 8100 transient recorder. The data consisted of 2084 intensity values representing the amplitude of pulses transmitted and received by the ultrasonic unit.

Smith, G. R.↗

Studies in astronomical time series analysis: Modeling random processes in the time domain

Random process models phased in the time domain are used to analyze astrophysical time series data produced by random processes. A moving average (MA) model represents the data as a sequence of pulses occurring randomly in time, with random amplitudes. An autoregressive (AR) model represents the correlations in the process in terms of a linear function of past values. The best AR model is determined from sampled data and transformed to an MA for interpretation. The randomness of the pulse amplitudes is maximized by a FORTRAN algorithm which is relatively stable numerically. Results of test cases are given to study the effects of adding noise and of different distributions for the pulse amplitudes. A preliminary analysis of the optical light curve of the quasar 3C 273 is given.

Scargle, J. D.↗

Advanced Water Vapor Lidar Detection System

In the present water vapor lidar system, the detected signal is sent over long cables to a waveform digitizer in a CAMAC crate. This has the disadvantage of transmitting analog signals for a relatively long distance, which is subjected to pickup noise, leading to a decrease in the signal to noise ratio. Generally, errors in the measurement of water vapor with the DIAL method arise from both random and systematic sources. Systematic errors in DIAL measurements are caused by both atmospheric and instrumentation effects. The selection of the on-line alexandrite laser with a narrow linewidth, suitable intensity and high spectral purity, and its operation at the center of the water vapor lines, ensures minimum influence in the DIAL measurement that are caused by the laser spectral distribution and avoid system overloads. Random errors are caused by noise in the detected signal. Variability of the photon statistics in the lidar return signal, noise resulting from detector dark current, and noise in the background signal are the main sources of random error. This type of error can be minimized by maximizing the signal to noise ratio. The increase in the signal to noise ratio can be achieved by several ways. One way is to increase the laser pulse energy, by increasing its amplitude or the pulse repetition rate. Another way, is to use a detector system with higher quantum efficiency and lower noise, on the other hand, the selection of a narrow band optical filter that rejects most of the day background light and retains high optical efficiency is an important issue. Following acquisition of the lidar data, we minimize random errors in the DIAL measurement by averaging the data, but this will result in the reduction of the vertical and horizontal resolutions. Thus, a trade off is necessary to achieve a balance between the spatial resolution and the measurement precision. Therefore, the main goal of this research effort is to increase the signal to noise ratio by a factor of 10 over the current system, using a newly evaluated, very low noise avalanche photo diode detector and constructing a 10 MHz waveform digitizer which will replace the current CAMAC system.

Elsayed-Ali, Hani↗

Infrared focal plane performance in the South Atlantic anomaly

Proton-induced pulse height distributions (PHD's) in Si:XX detectors were studied analytically and experimentally. In addition, a preliminary design for a flight experiment to characterize the response of Si:XX detectors to the trapped proton environment and verify PHD models was developed. PHD's were computed for two orbit altitudes for a variety of shielding configurations. Most of the proton-induced pulses have amplitudes less that about 3.5 x 10(exp 5) e-h pairs. Shielding has a small effect on the shape of the PHD's. The primary effect of shielding is to reduce the total number of pulses produced. Proton-induced PHD's in a Si:Sb focal plane array bombarded by a unidirectional 67-MeV beam were measured. The maximum pulse height recorded was 6 x 10(exp 5) pairs. The distribution had two peaks: the larger peak corresponded to 3.8 x 10(exp 5) pairs and the smaller peak to 1.2 x 10(exp 5) pairs. The maximum pulse height and the larger peak are within a factor of two of predicted values. The low-energy peak was not expected, but is believed to be an artifact of inefficient charge collection in the detector. The planned flight experiment will be conducted on a Space Shuttle flight. Lockheed's helium extended life dewar (HELD) will be used to provide the required cryogenic environment for the detector. Two bulk Si:Sb arrays and two Si:As impurity band conduction arrays will be tested. The tests will be conducted while the Space Shuttle passes through the South Atlantic Anomaly. PHD's will be recorded and responsivity changes tracked. This experiment will provide a new database on proton-induced PHD's, compare two infrared detector technologies in a space environment, and provide the data necessary to validate PHD modeling.

Junga, Frank A.↗

Accelerating Continuous Variable Coherent Ising Machines Via Momentum

The Coherent Ising Machine (CIM) is a non-conventional architecture that takes inspiration from physical annealing processes to solve Ising problems heuristically. Its dynamics are naturally continuous and described by a set of ordinary differential equations that have been proven to be useful for the optimization of continuous variables nonconvex quadratic optimization problems. The dynamics of such Continuous Variable CIMs (CV-CIM) encourage optimization via optical pulses whose amplitudes are determined by the negative gradient of the objective; however, standard gradient descent is known to be trapped by local minima and hampered by poor problem conditioning. In this work, we propose to modify the CV-CIM dynamics using more sophisticated pulse injections based on tried-and-true optimization techniques such as momentum and Adam. Through numerical experiments, we show that the momentum and Adam updates can significantly speed up the CV-CIM’s convergence and improve sample diversity over the original CV-CIM dynamics. We also find that the Adam-CV-CIM’s performance is more stable as a function of feedback strength, especially on poorly conditioned instances, resulting in an algorithm that is more robust, reliable, and easily tunable. More broadly, we identify the CIM dynamical framework as a fertile opportunity for exploring the intersection of classical optimization and modern analog computing.

Ising Model↗