Search NASA⌕ Search

SEARCH · Search NASA

Results for “PULSE RATE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

CO2 lasers and applications II; Proceedings of the Third European Congress on Optics, The Hague, Netherlands, Mar. 12-14, 1990

Recent advances in CO2 laser technology and its applications are examined. Topics discussed include the excitation of CO2 lasers by microwave discharge, a compact RF-excited 12-kW CO2 laser, a robotic laser for three-dimensional cutting and welding, three-dimensional CO2-laser material processing with gantry machine systems, and a comparison of hollow metallic waveguides and optical fibers for transmitting CO2-laser radiation. Consideration is given to an aerodynamic window with a pump cavity and a supersonic jet, cutting and welding Al using a high-repetition-rate pulsed CO2 laser, speckle reduction in CO2 heterodyne laser radar systems, high-power-laser float-zone crystal growth, melt dynamics in surface processing with laser radiation, laser hardfacing, surface melting of AlSi10Mg with CO2 laser radiation, material processing with Cu-vapor lasers, light-induced flow at a metal surface, and absorption measurements in high-power CW CO2-laser processing of materials.

Opower, Hans↗

Radar Altimetry For Topographical Mapping

Two altimeter concepts based on spaceborne synthetic-aperture-radar (SAR) proposed to gather global, uniformly sampled, high-resolution, topographical data on land and ice. Wide swath and high pulse rate of SAR makes possible to acquire spatially contiguous data over large areas in reasonable amount of time, and time needed for altimetric processing of SAR data considerably less than that needed to generate topographical maps from stereoscopic photographs. Radar less vulnerable to cloud cover and other weather conditions than optical techniques.

Im, Eastwood↗

The PIT MkV pulsed inductive thruster

The pulsed inductive thruster (PIT) is an electrodeless, magnetic rocket engine that can operate with any gaseous propellant. A puff of gas injected against the face of a flat (spiral) coil is ionized and ejected by the magnetic field of a fast-rising current pulse from a capacitor bank discharge. Single shot operation on an impulse balance has provided efficiency and I(sub sp) data that characterize operation at any power level (pulse rate). The 1-m diameter MkV thruster concept offers low estimated engine mass at low powers, together with power capability up to more than 1 MW for the 1-m diameter design. A 20 kW design estimate indicates specific mass comparable to Ion Engine specific mass for 10,000 hour operation, while a 100,000 hour design would have a specific mass 1/3 that of the Ion Engine. Performance data are reported for ammonia and hydrazine. With ammonia, at 32 KV coil voltage, efficiency is a little more than 50 percent from 4000 to more than 8000 seconds I(sub sp). Comparison with data at 24 and 28 kV indicates that a wider I(sub sp) range could be achieved at higher coil voltages, if required for deep space missions.

Dailey, C. Lee↗

The CRRES IDM spacecraft experiment for insulator discharge pulses

The Internal Discharge Monitor (IDM) is designed to observe electrical pulses from common electrical insulators in space service. The characteristics of the instrument are described. The IDM was flown on the Combined Release and Radiation Effects Satellite (CRRES). The sixteen insulator samples included G10 circuit boards, FR4 and PTFE fiberglass circuit boards, FEP Teflon, alumina, and wires with common insulations. The samples are fully enclosed, mutually isolated, and space radiation penetrates 0.02 cm of aluminum before striking the samples. Published data in the literature provides a simple method for determining the flux of penetrating electrons. The pulse rate is compared to the penetrating flux of electrons.

Frederickson, A. R.↗

In-flight imaging of transverse gas jets injected into transonic and supersonic crossflows: Design and development

The design and development of an airborne flight-test experiment to study nonreacting gas jets injected transversely into transonic and supersonic crossflows is presented. Free-stream/crossflow Mach numbers range from 0.8 to 2.0. Planar laser-induced fluorescence (PLIF) of an iodine-seeded nitrogen jet is used to visualize the jet flow. Time-dependent images are obtained with a high-speed intensified video camera synchronized to the laser pulse rate. The entire experimental assembly is configured compactly inside a unique flight-test-fixture (FTF) mounted under the fuselage of the F-104G research aircraft, which serves as a 'flying wind tunnel' at NASA Dryden Flight Research Center. The aircraft is flown at predetermined speeds and altitudes to permit a perfectly expanded (or slightly underexpanded) gas jet to form just outside the FTF at each free-stream Mach number. Recorded gas jet images are then digitized to allow analysis of jet trajectory, spreading, and mixing characteristics. Comparisons will be made with analytical and numerical predictions. This study shows the viability of applying highly sophisticated groundbased flow diagnostic techniques to flight-test vehicle platforms that can achieve a wide range of thermo/fluid dynamic conditions. Realistic flow environments, high enthalpies, unconstrained flowfields, and moderate operating costs are also realized, in contrast to traditional wind-tunnel testing.

Wang, Kon-Sheng Charles↗

Aircraft-borne, laser-induced fluorescence instrument for the in situ detection of hydroxyl and hydroperoxyl radicals

The odd-hydrogen radicals OH and HO2 are central to most of the gas-phase chemical transformations that occur in the atmosphere. Of particular interest is the role that these species play in controlling the concentration of stratospheric ozone. This paper describes an instrument that measures both of these species at volume mixing ratios below one part in 10(exp 14) in the upper troposphere and lower stratosphere. The hydroxyl radical (OH) is measured by laser induced fluorescence at 309 nm. Tunable UV light is used to pump OH to the first electric state near 282 nm. the laser light is produced by a high-repetition rate pulsed dye-laser powered with all solid-state pump lasers. HO2 is measured as OH after gas-phase titration with nitric oxide. Measurements aboard a NASA ER-2 aircraft demonstrate the capability of this instrument to perform reliably with very high signal-to-noise ratios (greater than 30) achieved in short integration times (less than 20 sec).

Wennberg, P. O.↗

The Mars Orbiter Altimeter (MOLA) Investigation of the Shape and Topography of Mars

The Mars Orbiter Laser Altimeter (MOLA) is an instrument on the Mars Global Surveyor (MGS) spacecraft that has been orbiting Mars since September 1997. After some preliminary observations in Sept/Oct, 1997 and in the spring and summer of 1998, the MGS spacecraft entered its mapping orbit of 400 km above the surface of Mars in February 1999. MGS began a 2 year program of systematically mapping the planet with a camera (MOC), thermal emission spectrometer (TES), magnetometer (MAG), laser altimeter (MOLA), and a radio science investigation for gravity and radio occultations. MOLA has a 48mJ, 1064 nrn ND:YAG, diode pumped laser with a 8 nanosecond pulse width, a pulse rate of 10 Hz, and a range precision of less than 40 cm. MOLA has been operating almost continuously for over two years and obtained over 600 million measurements of the radius of Mars. Using very precise orbits for the MGS spacecraft derived from the Doppler and range tracking of MGS by the Deep Space Network a topographical map of Mars has been developed with an average radial accuracy of a meter and a horizontal accuracy of 100 meters. This topographical map has revealed a new Mars, a planet with some of the flattest areas in the solar system and one of the largest impact basins. MOLA has revealed clear evidence of the effect of past fluid action on the surface and found icecaps that contain as much water ice today as the icecap of Greenland.

Smith, David E.↗

Mining CRRES IDM Pulse Data and CRRES Environmental Data to Improve Spacecraft Charging/Discharging Models and Guidelines

One can truly predict the charging and pulsing in space over a year's time using only the physics that worked for periods of an hour and less in prior publications. All portions of the task were achieved, including the optional portion of determining a value for conductivity that best .t the data. Fortran statements were developed that are required for the NUMIT runs to work with this kind of data from space. In addition to developing the Fortran for NUMIT, simple correlations between the IDM pulsing history and the space radiation were observed because we now have a better characterization of the space radiation. The study showed that: (1) the new methods for measurement of charge storage and conduction in insulators provide the correct values to use for prediction of charging and pulsing in space; (2) the methods in NUMIT that worked well for time durations less than hours now work well for durations of months; (3) an average spectrum such as AE8 is probably not a good guide for predicting pulsing in space one must take time dependence into account in order to understand insulator pulsing; and (4) the old method for predicting pulse rates in space that was based on the CRRES data could be improved to include dependencies on material parameters.

Brautigam, D. H.↗

Study of Static Microchannel Plate Saturation Effects for the Fast Plasma Investigation Dual Electron Spectrometers on NASA's Magnetospheric MultiScale Mission

Imaging detecting systems based on microchannel plates (MCPs) are the most common for low energy plasma measurements for both space borne and ground applications. One of the key parameters of these detection systems is the dynamic range of the MCP's response to the input fluxes of charged particles. For most applications the dynamic range of the linear response should be as wide as possible. This is especially true for the Dual Electron Spectrometers (DESs) of the Fast Plasma Investigation (FPI) on NASA's Magnetospheric MultiScale (MMS) mission because a wide range of input fluxes are expected. To make use of the full available dynamic range, it is important to understand the MCP response behavior beyond the linear regime where the MCPs start to saturate. We have performed extensive studies of this during the characterization and calibration of the DES instruments and have identified several saturation effects of the detection system. The MCP itself exhibits saturation when the channels lack the ability to replenish charge sufficiently rapidly. It is found and will be shown that the ground system can significantly impact the correct measurement of this effect. As the MCP starts to saturate, the resulting pulse height distribution (PHD) changes shape and location (with less pulse height values), which leads to truncation of the PHD by the threshold set on the detection system discriminator. Finally, the detection system pulse amplifier exhibits saturation as the input flux drives pulse rates greater than its linear response speed. All of these effects effectively change the dead time of the overall detection system and as a result can affect the quality and interpretation of the flight data. We present results of detection system saturation effects and their interaction with special emphasis on the MCP related effects.

detecting system↗

Design of a Direct-Detection Wind and Aerosol Lidar for Mars Orbit

The present knowledge of the Mars atmosphere is greatly limited by a lack of global measurements of winds and aerosols. Hence, measurements of height-resolved wind and aerosol profiles are a priority for new Mars orbiting missions. We have designed a direct-detection lidar (MARLI) to provide global measurements of dust, winds and water ice profiles from Mars orbit. From a 400-km polar orbit, the instrument is designed to provide wind and backscatter measurements with a vertical resolution of 2 km and with resolution of 2° in latitude along track. The instrument uses a single-frequency, seeded Nd:YAG laser that emits 4 mJ pulses at 1064 nm at a 250 Hz pulse rate. The receiver utilizes a 50-cm diameter telescope and a double edge Fabry-Pérot etalon as a frequency discriminator to measure the Doppler shift of the aerosol-backscatter profiles. The receiver also includes a polarization-sensitive channel to detect the cross-polarized backscatter profiles from water ice. The receiver uses a sensitive 4 × 4 pixel HgCdTe avalanche photodiode array as a detector for all signals. Here we describe the measurement concept, instrument design, and calculate its performance for several cases of Mars atmospheric conditions. The calculations show that under a range of atmospheric conditions MARLI is capable of measuring wind speed profiles with random error of 2–4 m/s within the first three scale heights, enabling vertically resolved mapping of transport processes in this important region of the atmosphere.

Cremons, Daniel R.↗

TPSAS-NF1676L-11930-DND

Under the NASA Laser Risk Reduction Program (LRRP), funded by Earth Science Technology Office (ESTO), an efficient, injection seeded, high repetition rate Tm:fiber laser pumped Ho:YLF laser has been developed and operation between 100 Hz to 10 kHz has been demonstrated. The work is underway to develop an efficient, high-repetition-rate, pulsed, 2-micron, coherent Differential Absorption Lidar (DIAL) / Integrated Path Differential Absorption (IPDA) instrument for measuring the atmospheric CO2 profiles (DIAL) and column densities (IPDA) from an airborne platform. In DIAL mode, this instrument will provide the first ever range-resolved, high-precision, remote measurements of the CO2 content of the atmospheric boundary layer (ABL) and lower troposphere.

Upendra N Singh↗

A Semi-Empirical Scheme for Bathymetric Mapping in Shallow Water by ICESat-2 and Sentinel-2: A Case Study in the South China Sea

To derive shallow water bathymetry for coastal areas, a common approach is to deploy a scanning airborne bathymetric light detection and ranging (LiDAR) system or a shipborne echosounder for ground surveys. However, recent advancements in satellite remote sensing, including the Ice, Cloud and land Elevation Satellite-2 (ICESat-2) offer new tools for generating satellite derived bathymetry (SDB). The key payload onboard ICESat-2 is the Advanced Topographic Laser Altimeter System (ATLAS), a micro-pulse, photon-counting LiDAR system, simultaneously emitting six separate 532 nm beams at 10 kHz pulse rate. However, despite its high resolution, the major limitation for bathymetry is that ICESat-2 only provides along-track height profiles, leaving observation gaps between the parallel ground tracks. Merging ICESat-2 observations with optical multispectral imagery, as demonstrated herein, provides an effective solution for deriving a full scene of water depth in light of the spectral attenuation behavior. This study aims to combine ICESat-2 and Sentinel-2 optical data to derive shallow water bathymetry (depth <20 m) at six islands and reefs in the South China Sea. ICESat-2 ATL03 point clouds of georeferenced photons are first filtered to determine the seafloor elevation along the ground track. Results indicate a root-mean-square error (RMSE) of 0.26–0.61 m as compared with independent observations from an airborne LiDAR campaign. Next, three semi-empirical functions, namely the Modified Linear/Polynomial/Exponential Ratio Models with its kernel formed by the log ratio between Sentinel-2′s green and blue bands, are used to fit the spectral data with ICESat-2 height profiles. After water depth mapping using the trained model, independent ICESat-2 point clouds are used to validate the Sentinel-2 derived bathymetry. The RMSE values of the three models using the weighted average of multiple images for these six islands are within 0.50–0.90 m in 0–15 m deep. We also demonstrate that a synthesis of satellite laser altimetry and optical remote sensing can produce SDB results that potentially meet the requirement of category C in Zones of Confidence (ZOC) of the Electronic Navigational Chart (ENC) in 0–8 m deep. It is foreseen that ICESat-2 will be a helpful tool for mapping coastal and shallow waters around the world especially where bathymetric data are unavailable.

Coastal Bathymetry↗

Preparation for an Earth Independent Medical Operations Demonstration using the Tempus ALS™ Medical Device

NASA’s exploration-class missions have severe resource constraints, long return trip durations, significant communication delays and limited resupply opportunities. Validation on the International Space Station (ISS) of medical devices that fit within Earth-Independent Medical Operations (EIMO) systems is a necessary preparation step. Key features of an EIMO medical system include: 1) technologies that support the prevention, diagnosis, and treatment of spaceflight medical events; 2) components that meet mass, volume, power and crew time/training constraints; 3) consideration of the medical skill level of the astronaut caregiver; 4) collection, storage and analysis of medical data within a central data architecture; and 5) incorporation of appropriate guidance and support tools that allow crew autonomy. The Human Research Program’s (HRP) Exploration Medical Capability (ExMC) Element and the Exploration Medical Integrated Product Team (XM-IPT) are planning an ISS technology demonstration to determine the feasibility of including a multifunctional medical device into an EIMO medical system. Demonstration Preparations: The Tempus ALS (Remote Diagnostic Technologies, Ltd., Philips Corp., Farnborough, UK) is a commercial-off-the-shelf medical device, with United States Food and Drug Administration clearance and is Conformité Européene marked in Europe. Several thousand units have been sold and are successfully operating in pre-hospital and in remote settings, such as by European Space Agency (ESA) flight surgeons and some of NASA’s commercial partners during post-flight medical operations. The Tempus ALS provides vital sign measurements such as blood pressure, electrocardiograms, heart rate, end tidal CO2, respiration rate, pulse oximetry and temperature. The device has ultrasound imaging and video laryngoscopy capabilities and has automatic or manual defibrillation modes for treating cardiac arrhythmias. It includes procedural guidance capabilities to assist in the collection of the vital sign measurements and it has various data transmission and report generation features. NASA’s HRP ExMC and XM-IPT are partnering with the ESA to demonstrate the Tempus ALS on ISS, with ESA manifesting the Tempus ALS and its accessories. ESA will compare performance of periodic health status exams and medical contingency drills performed nominally and with the Tempus ALS. NASA’s EIMO demonstration will include the use of Tempus ALS to diagnose a complaint of abdominal pain under increasingly independent circumstances. The caregiver must assess the present illness, collect vital sign measurements, and perform an abdominal ultrasound, under one of three communication situations, including real-time, with a several second delay and with a delay on the order of minutes. Expected Outcomes: Information will be gained about the feasibility, benefits, and challenges of using a multifunctional, all-in-one, medical device for medical diagnosis instead of separate devices with singular functionalities. Information will also be collected about performance differences as communication delays increase and available ground support decreases. Gaining this understanding will allow for further development of exploration medical system capabilities which takes the EIMO construct into consideration.

Beth Lewandowski↗

A Multi-Faceted Approach to Demonstrating Multi-Functional Integrated Medical Devices to Advance Earth-Independent Medical Operations

INTRODUCTION TO MIM DEVICES Multi-functional Integrated Medical (MIM) devices conveniently incorporate multiple medical system capabilities within one device. The NASA Exploration Medical Integrated Product Team (XM-IPT) sponsored a market survey and trade study which identified the Tempus ProTM and the LifeBot 10® as the MIM devices that best met the evaluation criteria of the trade study. The Tempus ProTM (Remote Diagnostic Technologies, Ltd., Philips Corp., Farnborough, UK) and LifeBot 10® (LifeBot Health, Chicago, IL) both provide vital sign measurements such as blood pressure, electrocardiograms, heart rate, end tidal CO2, respiration rate, pulse oximetry and temperature along with ultrasound imaging. A video laryngoscopy capability is unique to the Tempus ProTM, while the LifeBot 10® supports connectivity with a digital stethoscope, otoscope, eye exam camera, and dermatoscope. Both devices include procedural guidance capabilities and have various data transmission and report generation features. TECHNOLOGY DEMONSTRATIONS NASA’s exploration-class missions will have severe resource constraints, long return trip durations, significant communication delays, and limited resupply opportunities. The medical systems of these missions will need to fit within an Earth-Independent Medical Operations (EIMO) construct. Key features of an EIMO medical system include: 1) technologies that support the prevention, diagnosis, and treatment of spaceflight medical events; 2) components that meet mass, volume, power and crew time/training constraints; 3) consideration of the medical skill level of the astronaut caregiver; 4) collection, storage and analysis of medical data within a central data architecture; and 5) incorporation of appropriate guidance and support tools that allow crew autonomy. Evaluations are underway to determine if it will be beneficial to include MIM devices within exploration medical systems by conducting a series of planned technical demonstrations. Exploration Atmosphere Chamber studies are being performed to determine MIM functionality in a high oxygen concentration atmosphere. A side-by-side comparison of the Tempus ProTM and LifeBot 10® will be performed during ground-based demonstrations. Use of the MIM devices within an EIMO medical scenario simulation will be practiced during ground-based demonstrations in preparation for International Space Station (ISS) demonstrations of the MIM device. These various demonstrations are designed to gather evidence for or against the inclusion of MIM devices within an EIMO medical system. EXPECTED DEMONSTRATION OUTCOMES Information will be gained about the feasibility, benefits, and challenges of using a multifunctional, all-in-one, medical device for medical diagnosis. Information will also be collected about performance differences as available ground support decreases. Gaining this understanding will allow for further development of exploration medical system capabilities, which take the EIMO construct into consideration.

B. E. Lewandowski↗

Separation Control in a Multistage Compressor Using Impulsive Surface Injection

Control of flow separation using impulsive surface injection is investigated within the multistage environment of a low speed axial-flow compressor. Measured wake profiles behind a set of embedded stator vanes treated with suction-surface injection indicate significant reduction in flow separation at a variety of injection-pulse repetition rates and durations. The corresponding total pressure losses across the vanes reveal a bank of repetition rates at each pulse duration where the separation control remains nearly complete. This persistence allows for demands on the injected-mass delivery system to be economized while still achieving effective flow control. The response of the stator-vane boundary layers to infrequently applied short injection pulses is described in terms of the periodic excitation of turbulent strips whose growth and propagation characteristics dictate the lower bound on the band of optimal pulse repetition rates. The eventual falloff in separation control at higher repetition rates is linked to a competition between the benefits of pulse-induced mixing and the aggravation caused by the periodic introduction of low-momentum fluid. Use of these observations for impulsive actuator design is discussed and their impact on modeling the time-average effect of impulsive surface injection for multistage steady-flow simulation is considered.

Wundrow, David W.↗

Reliability of Autonomic Responses and Malaise Across Multiple Motion Sickness Stimulation Tests

There is general agreement that a high degree of variability exists between subjects in their autonomic nervous system responses to motion sickness stimulation. Additionally, a paucity of data exists that examines the variability within an individual across repeated motion sickness tests. Investigators have also examined the relationship of autonomic responses to motion sickness development. These investigations have used analyses at discrete points in time to describe this relationship. This approach fails to address the time course of autonomic responses and malaise development throughout the motion sickness test. Our objectives were to examine the reliability of autonomic responses and malaise using the final minute of the motion sickness test across five testing occasions, to examine the reliability of the change in autonomic responses and the change in malaise across five testing occasions, and to examine the relationship between changes in autonomic responses and changes in malaise level across the entire motion sickness test. Our results indicate that, based on the final minute of testing, the autonomic responses of heart rate, blood volume pulse, and respiration rate are moderately stable across multiple tests. Changes in heart rate, blood volume pulse, respiration rate, and malaise throughout the test duration were less stable across the tests. We attribute this instability to variations in individual susceptibility and the error associated with estimating a measure of autonomic gain.

Stout, Cynthia S.↗