Search NASA⌕ Search

SEARCH · Search NASA

Results for “PULSES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Behavior of 2-Cell CPV Ni-H2 Battery During Pulse Discharge

A study was carried out to determine the transient voltage behavior of the 2-cell CPV nickel-hydrogen battery with the objective of using the results as a basis for mathematical modeling. The 2-cell CPV battery which is manufactured by Eagle Picher, Inc. for the GOES program yields 18.5 Ah at C/2 rate of discharge at 10 C with a mid-discharge voltage of 2.514 V. The capacity increased with decrease of temperature and a maximum capacity of 22 Ah was obtained at -5 C. The pulse tests consisted of obtaining the voltage profile in the first 20 milliseconds of the one minute pulse discharge at 37 A and pulse discharge was repeated as a function of state-of-charge. The pulse test at 10 C and 20 C provided voltage profiles with the expected decrease in voltage as the pulse was applied. The end of pulse voltage decreased with the state-of-charge. The battery voltage was above 2V at the end of the one-minute pulse at 8 % state-of-charge at 10 C. The voltage profile during the 37 A pulse discharge consists of an initial drop in voltage which was independent of the state of charge. The invariability in the value for the initial drop in voltage with state of charge is a very important observation. The results show that towards the end of discharge the dominant resistance is not ohmic in nature. It could be hypothesized from the nature of the voltage transients that the dominant mechanism towards the end of discharge is proton diffusion. The study also shows that the dominant resistance in the voltage plateau during discharge is activation polarization.

Vaidyanathan, Hari↗

Behavior of 2 Cell CPV NI-H2 Battery During Pulse Discharge

A study was carried out to determine the transient voltage behavior of the 2-cell CPV nickel-hydrogen battery with the objective of using the results as a basis for mathematical modeling. The 2-cell CPV battery which is manufactured by Eagle Picher, Inc. for the GOES program yields 18.5 Ah at C/2 rate of discharge at 10 C with a mid-discharge voltage of 2.514 V. The capacity increased with decrease of temperature and a maximum capacity of 22 Ah was obtained at - 5 C. The pulse test consisted of obtaining the voltage profile in the first 20 milliseconds of the one minute pulse discharge at 37 A and pulse discharge was repeated as a function of state-of-charge. The pulse test at 10 C and 20 C provided voltage profiles with the expected decrease in voltage as the pulse was applied. The end of pulse voltage decreased with the state-of-charge. The battery voltage was above 2V at the end of the one-minute pulse at 12% state-of-charge at 10 C. The voltage profile during the 37 A pulse discharge consists of an initial drop in voltage which was independent of the state of charge. The invariability in the value for the initial drop in voltage with state of charge is a very important observation and indicates that towards the end of discharge the dominant resistance is not ohmic in nature. It could be hypothesized from the nature of the voltage transients that the dominant mechanism towards the end of discharge is proton diffusion. The study also shows that the dominant resistance in the voltage plateau during discharge is activation polarization.

Gopalakrishna, M. Rao↗

Pulsed Laser Illumination of Photovoltaic Cells

In future space missions, free electron lasers (FEL) may be used to illuminate photovoltaic array receivers to provide remote power. The induction FEL and the radio-frequency (RF) FEL both produce pulsed rather than continuous output. In this work, we investigate cell response to pulsed laser light which simulates the RF FEL format, producing 50 ps pulses at a frequency of 78 MHz. A variety of Si, GaAs, CaSb and CdInSe2 (CIS) solar cells are tested at average incident powers between 4 mW/sq cm and 425 mW/sq cm. The results indicate that if the pulse repetition is high, cell efficiencies are only slightly reduced by using a pulsed laser source compared to constant illumination at the same wavelength. Because the pulse separation is less than or approximately equal to the minority carrier lifetime, the illumination conditions are effectively those of a continuous wave laser. The time dependence of the voltage and current response of the cells are also measured using a sampling oscilloscope equipped with a high frequency voltage probe and current transformer. The frequency response of the cells is weak, with both voltage and current outputs essentially dc in nature. Comparison with previous experiments shows that the RF FEL pulse format yields much more efficient photovoltaic conversion of light than does an induction FEL pulse format.

Yater, Jane A.↗

Evaluation and Characterization Study of Dual Pulse Laser-Induced Spark (DPLIS) for Rocket Engine Ignition System Application

This paper addresses the progress of technology development of a laser ignition system at NASA Marshall Space Flight Center (MSFC). Laser ignition has been used at MSFC in recent test series to successfully ignite RP1/GOX propellants in a subscale rocket chamber, and other past studies by NASA GRC have demonstrated the use of laser ignition for rocket engines. Despite the progress made in the study of this ignition method, the logistics of depositing laser sparks inside a rocket chamber have prohibited its use. However, recent advances in laser designs, the use of fiber optics, and studies of multi-pulse laser formats3 have renewed the interest of rocket designers in this state-of the-art technology which offers the potential elimination of torch igniter systems and their associated mechanical parts, as well as toxic hypergolic ignition systems. In support of this interest to develop an alternative ignition system that meets the risk-reduction demands of Next Generation Launch Technology (NGLT), characterization studies of a dual pulse laser format for laser-induced spark ignition are underway at MSFC. Results obtained at MSFC indicate that a dual pulse format can produce plasmas that absorb the laser energy as efficiently as a single pulse format, yet provide a longer plasma lifetime. In an experiments with lean H2/air propellants, the dual pulse laser format, containing the same total energy of a single laser pulse, produced a spark that was superior in its ability to provide sustained ignition of fuel-lean H2/air propellants. The results from these experiments are being used to optimize a dual pulse laser format for future subscale rocket chamber tests. Besides the ignition enhancement, the dual pulse technique provides a practical way to distribute and deliver laser light to the combustion chamber, an important consideration given the limitation of peak power that can be delivered through optical fibers. With this knowledge, scientists and engineers at Los Alamos National Laboratory and CFD Research Corporation have designed and fabricated a miniaturized, first-generation optical prototype of a laser ignition system that could be the basis for a laser ignition system for rocket applications. This prototype will be tested at MSFC in future subscale rocket ignition tests.

Osborne, Robin↗

Analysis of Pulsed Airborne Lidar Measurements of Atmospheric CO2 Column Absorption from 3-13 km Altitudes

We have developed a pulsed lidar technique for measuring the tropospheric CO2 concentrations as a candidate for NASA's ASCENDS space mission [1]. It uses two pulsed laser transmitters allowing simultaneous measurement of a CO2 absorption line in the 1575 nm band, O2 extinction in the Oxygen A-band, surface height and backscatter profile. The lasers are precisely stepped in wavelength across the CO2 line and an O2 line region during the measurement. The direct detection receiver measures the energies of the laser echoes from the surface along with the range profile of scattering in the path. The column densities for the CO2 and O2 gases are estimated from the ratio of the on- and off-line signals via the integrated path differential absorption (IPDA) technique. The time of flight of the laser pulses is used to estimate the height of the scattering surface and to reject laser photons scattered in the atmosphere. We developed an airborne lidar to demonstrate an early version of the CO2 measurement from the NASA Glenn Lear-25 aircraft. The airborne lidar stepped the pulsed laser's wavelength across the selected CO2 line with 20 wavelength steps per scan. The line scan rate is 450 Hz, the laser pulse widths are 1 usec, and laser pulse energy is 24 uJ. The time resolved laser backscatter is collected by a 20 cm telescope, detected by a NIR photomultiplier and is recorded on every other reading by a photon counting system [2]. During August 2009 we made a series of 2.5 hour long flights and measured the atmospheric CO2 absorption and line shapes using the 1572.33 nm CO2 line. Measurements were made at stepped altitudes from 3-13 km over locations in the US, including the SGP ARM site in Oklahoma, central Illinois, north-eastern North Carolina, and over the Chesapeake Bay and the eastern shore of Virginia. Although the received signal energies were weaker than expected for ASCENDS, clear CO2 line shapes were observed at all altitudes, and some measurements were made through thin clouds. The Oklahoma and east coast flights were coordinated with a LaRC/ITT CO2 lidar on the LaRC UC-12 aircraft, and in-situ measurements were made using its CO2 sensor and radiosondes. We have conducted an analysis of the ranging and IPDA lidar measurements from these four flights. Most flights had 5-6 altitude steps with 200-300 seconds of recorded measurements per step. We used a cross-correlation approach to process the laser echo records. This was used to estimate the range to the scattering surface, to define the edges of the laser pulses and to determine echo pulse energy at each wavelength. We used a minimum mean square approach to fit an instrument response function and to solve for the best-fit CO2 absorption line shape. We then calculated the differential optical depth (DOD) of the fitted CO2 line. We computed its statistics at the various altitude steps, and compare them to the DODs calculated from spectroscopy based on HITRAN 2008 and the column conditions calculated from the airborne in-situ readings. The results show the lidar and in-situ measurements have very similar DOD change with altitude and greater than 10 segments per flight where the scatter in the lidar measurements are less than or equal to 1ppm. We also present the results from subsequent CO2 column absorption measurements, which were made with stronger detected signals during three flights on the NASA DC-8 over the southwestern US in during July 2010.

Abshire, James B.↗

Self-Calibration and Laser Energy Monitor Validations for a Double-Pulsed 2-Micron CO2 Integrated Path Differential Absorption Lidar Application

Double-pulsed 2-micron integrated path differential absorption (IPDA) lidar is well suited for atmospheric CO2 remote sensing. The IPDA lidar technique relies on wavelength differentiation between strong and weak absorbing features of the gas normalized to the transmitted energy. In the double-pulse case, each shot of the transmitter produces two successive laser pulses separated by a short interval. Calibration of the transmitted pulse energies is required for accurate CO2 measurement. Design and calibration of a 2-micron double-pulse laser energy monitor is presented. The design is based on an InGaAs pin quantum detector. A high-speed photo-electromagnetic quantum detector was used for laser-pulse profile verification. Both quantum detectors were calibrated using a reference pyroelectric thermal detector. Calibration included comparing the three detection technologies in the single-pulsed mode, then comparing the quantum detectors in the double-pulsed mode. In addition, a self-calibration feature of the 2-micron IPDA lidar is presented. This feature allows one to monitor the transmitted laser energy, through residual scattering, with a single detection channel. This reduces the CO2 measurement uncertainty. IPDA lidar ground validation for CO2 measurement is presented for both calibrated energy monitor and self-calibration options. The calibrated energy monitor resulted in a lower CO2 measurement bias, while self-calibration resulted in a better CO2 temporal profiling when compared to the in situ sensor.

Refaat, Tamer F.↗

Development and Testing of Pulse Guns for Combustion Instability Testing

Combustion stability requirements of a liquid propellant rocket engine are most commonly verified by evaluating the oscillatory pressure or vibration characteristics following an artificial disturbance of the combustion in the combustion chamber. Two types of devices are most commonly used for dynamic stability rating – nondirectional bombs and pulse guns. Bombs have historically been used most often, especially for the large engines developed around the Apollo era. However, bombs in recent years have become much more expensive and difficult to procure, and their transportation and handling requirements have become more demanding. Pulse guns, with inherently less expensive materials, and far less restrictive handling and shipping requirements, have become an attractive alternative. The NASA Marshall Space Flight Center has developed a pulse gun for use during future development programs at the center, and as a design reference for interested commercial users. The objective of this paper is to present the different variants of the pulse gun and characterize performance over a range of parameters. The parameters include the breech diameter and corresponding volume, barrel length, amount of gun powder used, the method of containing the gunpowder within the breech, and the pressure rating of the burst disk. In total, 44 tests were conducted with the pulse gun firing into a test chamber pressurized to 2300 psig with gaseous nitrogen. The best experimental results – including the highest and most consistent peak pressure amplitudes recorded by dynamic pressure sensors in the test chamber – were from a configuration consisting of a 0.40” inner-diameter breech, 15-16 grains of gunpowder wrapped in cigarette paper, and a 24,000 psid burst disk. With this configuration, the zero-to-peak overpressures recorded in the test chamber ranged from about 37% to 58% of the 2300 psig mean pressure, which is adequate for typical combustion stability rating. To complement the data analysis, the acoustics of the pressure waves as they propagated through the pulse gun and into the test chamber were modeled. A more comprehensive final report of this pulse gun development program is planned to be available in the near future.

Pulse Gun↗

Effect of thruster pulse length on thruster-exhaust damage of S13G white thermal control coatings

Rocket exhaust products which strike thermal control surfaces cause changes in solar absorptance (Alpha Sub s) and thermal emittance (Epsilon) of these surfaces. A study was made of the effect of rocket pulse duration on exhaust damage to S13G white coatings. Two pulse lengths were used - 14 msec and 50 msec. An MMH/N204 bipropellant 5-lb thrust rocket was fired into a simulated space environment with a vacuum of 0.00001 torr, a liquid helium temperature enclosure, and solar radiation. The changes in solar absorptance and thermal emittance of S13G white coatings due to rocket exhaust were made in-situ for total firing times of 58 seconds with 14 msec pulses and 223.7 sec with 50 msec pulses. The solar absorptance of S13G increased 25 percent due to 223.7 sec of exposure to 50 msec pulses and the thermal emittance was unaffected. The ratio of Alpha Sub s/Epsilon therefore increased by 25 percent. The short 14 msec pulse exhaust exposure caused between 40 and 70 percent increase in solar absorptance and a decrease of between 13 and 18 percent in thermal emittance. The corresponding increase in Alpha Sub s/Epsilon ratio was between 80 and 100 percent. Ultraviolet radiation was present in the short pulse test and may have contributed to the large damage of that test.

Sommers, R. D.↗

Pulse pile-up in hard X-ray detector systems

When pulse-height spectra are measured by a nuclear detection system at high counting rates, the probability that two or more pulses will arrive within the resolving time of the system is significant. This phenomenon, pulse pile-up, distorts the pulse-height spectrum and must be considered in the interpretation of spectra taken at high counting rates. A computational technique for the simulation of pile-up is developed. The model is examined in the three regimes where (1) the time between pulses is long compared to the detector-system resolving time, (2) the time between pulses is comparable to the resolving time, and (3) many pulses occur within the resolving time. The technique is used to model the solar hard X-ray experiment on the OSO-7 satellite; comparison of the model with data taken during three large flares shows excellent agreement. The paper also describes rule-of-thumb tests for pile-up and identifies the important detector design factors for minimizing pile-up, i.e., thick entrance windows and short resolving times in the system electronics.

Datlowe, D. W.↗

ADRF experiments using near n.pi pulse strings

Adiabatic demagnetization (ADRF) can be achieved in a dipolar coupled nuclear spin system in solids by applying a string of short RF pulses and gradually modulating the pulse amplitudes or pulse angles. This letter reports an adiabatic inverse polarization effect in solids and a rotary spin echo phenomenon observed in liquids when the pulse angle is gradually changed across integral multiples of pi during a string of RF pulses. The RF pulse sequence used is illustrated along with the NMR signal from a CaF2 single crystal as observed between the RF pulses and the rotary spin echo signal observed in liquid C6F6 for n = 2. The observed effects are explained qualitatively on the basis of average Hamiltonian theory.

Rhim, W. K.↗

Integrated pulse profiles and mean fluxes of 24 pulsars at 2.388 gigahertz

Integrated pulse profiles are presented which represent the superposition of several hundred thousand pulses and approximate the true mean pulse profiles at 2.388 GHz for 24 pulsars. Observed interpulses are examined, the mean pulse energy associated with each integrated pulse profile is determined, and peak pulse fluxes are estimated. Comparison with later observations at 2.7 GHz indicates significant differences between the mean pulse energies measured at 2.388 and 2.7 GHz in several cases.

Downs, G. S.↗

Observations and interpretations of the pulsed emission from the Crab pulsar

HEAO 1 observations of the 18-200 keV pulsed emission from the Crab pulsar show that the systematic variation of spectral slope as a function of pulse shape rises continuously from 4-60 keV to at least 150 keV. This strengthens the claims for the existence of both the emission from the two main pulse peaks, and a separate, interpulse emission connecting the two peaks which contributes 22% of the total pulsed flux in the 15-200 keV range and has a harder spectrum than that of the two pulse peaks. These observations are combined with others from IR to gamma-ray energies. It is concluded that the phase-averaged pulsed spectrum, dominated by the emission from the two pulse peaks, calls for at least three power law components, and that the interpulse emission has a spectrum which is better fitted by either a thin, thermal bremsstrahlung model or a Comptonization model.

Knight, F. K.↗

SETI Pulse Detection Algorithm: Analysis of False-alarm Rates

Some earlier work by the Search for Extraterrestrial Intelligence (SETI) Science Working Group (SWG) on the derivation of spectrum analyzer thresholds for a pulse detection algorithm based on an analysis of false alarm rates is extended. The algorithm previously analyzed was intended to detect a finite sequence of i periodically spaced pulses that did not necessarily occupy the entire observation interval. This algorithm would recognize the presence of such a signal only if all i-received pulse powers exceeded a threshold T(i): these thresholds were selected to achieve a desired false alarm rate, independent of i. To simplify the analysis, it was assumed that the pulses were synchronous with the spectrum sample times. This analysis extends the earlier effort to include infinite and/or asynchronous pulse trains. Furthermore, to decrease the possibility of missing an extraterrestrial intelligence signal, the algorithm was modified to detect a pulse train even if some of the received pulse powers fall below the threshold. The analysis employs geometrical arguments that make it conceptually easy to incorporate boundary conditions imposed on the derivation of the false alarm rates. While the exact results can be somewhat complex, simple closed form approximations are derived that produce a negligible loss of accuracy.

Levitt, B. K.↗

The experimental cascade curves of EAS at E sub 0 10(17) eV obtained by the method of detection of Cherenkov pulse shape

The individual cascade curves of EAS with E sub 0 10 to the 17th power eV/I to 3/ were studied by detection of EAS Cherenkov light pulses. The scintillators located at the center of the Yakutsk EAS array within a 500-m radius circle were used to select the showers and to determine the main EAS parameters. The individual cascade curves N(t) were obtained using the EAS Cherenkov light pulses satisfying the following requirements: (1) the signal-to-noise ratio fm/delta sub n 15, (2) the EAS axis-detector distance tau sub 350 m, (3) the zenith angle theta 30 deg, (4) the probability for EAS to be detected by scintillators W 0.8. Condition (1) arises from the desire to reduce the amplitude distortion of Cherenkov pulses due to noise and determines the range of EAS sizes, N(t). The resolution times of the Cherenkov pulse shape detectors are tau sub 0 approx. 23 ns which results in distortion of a pulse during the process of the detection. The distortion of pulses due to the finiteness of tau sub 0 value was estimated. It is shown that the rise time of pulse becomes greater as tau sub 0.5/tau sub 0 ratio decreases.

Fomin, Y. A.↗

Vela X-1 pulse timing. I - Determination of the neutron star orbit

Analysis and interpretation of observations of the pulsed X-ray emission from Vela X-1 are presented. The interrelated tasks of determining the neutron-star orbit and calculating pulse emission times in the rest frame of the source are considered, with the underlying motivation to utilize this time series for analysis of fluctuations in the pulse emission frequency, which are interpreted as noise in the neutron-star rotation rate. However, the redness and strength of this noise in Vela X-1 pose a nontrivial complication, because the parameters of the neutron-star orbit are estimated by pulse timing and hence are themselves affected by fluctuations in the pulse emission frequency. A second challenge is presented by substantial fluctuations in the Vela X-1 pulse shape that, if ignored, would significantly reduce both the precision of the orbital solution and the ability to study fluctuations in the rotation rate. The report emphasizes the analysis techniques that have been developed to obtain the most precise orbital solution possible in the face of these difficulties. These techniques are general and may be applied to other pulsars that exhibit substantial fluctuations in pulse shape and frequency, such as Her X-1 and Cen X-3.

Boynton, P. E.↗

Picosecond pulse measurements using the active laser medium

A simple method for measuring the pulse lengths of synchronously pumped dye lasers which does not require the use of an external nonlinear medium, such as a doubling crystal or two-photon fluorescence cell, to autocorrelate the pulses is discussed. The technique involves feeding the laser pulses back into the dye jet, thus correlating the output pulses with the intracavity pulses to obtain pulse length signatures in the resulting time-averaged laser power. Experimental measurements were performed using a rhodamine 6G dye laser pumped by a mode-locked frequency-doubled Nd:YAG laser. The results agree well with numerical computations, and the method proves effective in determining lengths of picosecond laser pulses.

Bernardin, James P.↗

Experiment and theoretical study of the propagation of high power microwave pulse in air breakdown environment

In the study of the propagation of high power microwave pulse, one of the main concerns is how to minimize the energy loss of the pulse before reaching the destination. In the very high power region, one has to prevent the cutoff reflection caused by the excessive ionization in the background air. A frequency auto-conversion process which can lead to reflectionless propagation of powerful EM pulses in self-generated plasmas is studied. The theory shows that under the proper conditions the carrier frequency, omega, of the pulse will indeed shift upward with the growth of plasma frequency, omega(sub pe). Thus, the plasma during breakdown will always remain transparent to the pulse (i.e., omega greater than omega(sub pe)). A chamber experiment to demonstrate the frequency auto-conversion during the pulse propagation through the self-generated plasma is then conducted in a chamber. The detected frequency shift is compared with the theoretical result calculated y using the measured electron density distribution along the propagation path of the pulse. Good agreement between the theory and the experiment results is obtained.

Kuo, S. P.↗

Applications of ultrashort laser pulses in science and technology; Proceedings of the Meeting, The Hague, Netherlands, Mar. 12, 13, 1990

Topics discussed are on the generation of high-intensity femtosecond lasers, the high-repetition and infrared femtosecond pulses, and physics of semiconductors and applications. Papers are presented on the femtosecond pulse generation at 193 nm; the generation of intense subpicosecond and femtosecond pulses; intense tunable subpicosecond and femtosecond pulses in the visible and infrared, generated by optical parametric oscillators; a high-efficiency high-energy optical amplifier for femtosecond pulses; and the generation of solitons, periodic pulsing, and nonlinearities in GaAs. Other papers are on ultrafast relaxation dynamics of photoexcited carriers in GaAs, high-order optical nonlinear susceptibilities of transparent glasses, subnanosecond risetime high-power pulse generation using photoconductive bulk GaAs devices, femtosecond studies of plasma formation in crystalline and amorphous silicon, and subpicosecond dynamics of hot carrier relaxation in InP and GaAs.

Antonetti, Andre↗