Search NASA⌕ Search

SEARCH · Search NASA

Results for “PV CAPACITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Agrivoltaics: Solar Farming for a Greener Future

Resilient, secure, diversified, and disaster-hardened energy systems are critical to Puerto Rico's clear energy future. This presentation builds on NREL's PR100 One Year Progress Summary Report, discussing the intersection of land availability, PV capacity growth, and the potential role of agrivoltaics in contributing to Puerto Rico's 100% renewable energy goal and agricultural sector resilience. An overview of the state-of-the-science in agrivoltaics is provided, including the NREL InSPIRE Puerto Rican pilot project on hurricane-resistant, shade-grown agrivoltaic coffee. Agrivoltaics is discussed in the context of food-energy resilience for island nations, and future research & development needs are highlighted.

agrivoltaics↗

PV + Storage, Resiliency, Capacity, and Ancillary Services in SAM

This presentation from the PV Performance Modeling Collaborative workshop, grid integration track, in May 2019 outlines the current PV + Storage capabilities in the System Advisor Model (SAM) and highlights several upcoming capabilities related to storage, resiliency, capacity, and ancillary services.

14 SOLAR ENERGY↗

Influence of Hybridization on the Capacity Value of PV and Battery Resources

Utility-scale systems that combine solar photovoltaic and battery (PV+battery) technologies are growing in popularity on the U.S. bulk power system. The business case for PV+battery systems depends on both their ability to reduce costs and their ability to generate value synergies associated with the provision of energy, capacity, and ancillary services. Capacity value can constitute a significant portion of the value PV+battery hybrids provide to the grid (e.g., through avoided or deferred capacity) and receive through revenues. Throughout this report, we define capacity value as the monetary value of a plant's contribution towards the planning reserve margin, which ultimately depends on market rules and structures. PV+battery hybrids do not always fit into current market structures because of the interactions between the PV and battery components. Unique considerations for the capacity value of PV+battery hybrids include the disparate nature of participation models for PV and battery technologies in existing market rules and the potential influence of a shared interconnection capacity; limitations imposed by a shared inverter; limited ability to charge the battery in advance of capacity events if charging must be sourced from the coupled PV; and challenges or uncertainties associated with co-optimizing the operations of the PV and battery components. Grid operators are currently considering how market structures can be modified to optimally determine the capacity value provided by PV+battery systems, and the rules of how they are integrated into markets are still being written. As with any resource, poorly designed rules could increase the cost of energy and reduce system reliability, while well-designed rules could allow markets to receive the full benefits hybrid systems can offer without overcompensating them for the services they provide. Well-designed rules for PV+battery systems must consider the unique aspects listed above, while leveraging the commonalities with existing resource types. In this report, we summarize the technical capability and market rules that influence the capacity value of PV+battery systems. We further discuss the potential tradeoffs between computational complexity and accuracy for the various ways in which grid operators can credit PV+battery systems for capacity. Finally, we describe markets for capacity, survey current wholesale market rules applying to PV+battery systems, and provide a snapshot of the current regulatory landscape for PV+battery systems.

14 SOLAR ENERGY↗

Comparing Capacity Value Estimation Techniques for Photovoltaic Solar Power

In this paper, we estimate the capacity value of photovoltaic (PV) solar plants in the western U.S. Our results show that PV plants have capacity values that range between 52% and 93%, depending on location and sun-tracking capability. We further compare more robust but data- and computationally-intense reliability-based estimation techniques with simpler approximation methods. We show that if implemented properly, these techniques provide accurate approximations of reliability-based methods. Overall, methods that are based on the weighted capacity factor of the plant provide the most accurate estimate. We also examine the sensitivity of PV capacity value to the inclusion of sun-tracking systems.

14 SOLAR ENERGY↗

Closing the Loops on Solar Photovoltaics Modules: An Agent-Based Modeling Approach for the Study of Circular Economy Strategies

Solar photovoltaics (PV) installed capacity have grown exponentially since the early 2000s (average annual growth rate of 50%). With 4,700 GW projected installed capacity by 2050, the volume of PV panels waste is also expected to become substantial. Though renewables are a sine qua non to the establishment of a truly circular economy (CE), the issue arising from their end-of-life management needs to be resolved. The management of PV end-of-life also represent a singular opportunity to create value, from recovered valuable, rare or critical materials (e.g. silver, tellurium, indium). Moreover, the PV case illustrates some of the current barriers to CE; for instance, the need for a common definition of waste (PV are defined as e-waste in the European Union but as general waste in the United States) and potential loss of innovations' advantages (PV average efficiency has continuously grown the past 10 years). In this study, an agent-based modeling (ABM) approach is proposed to simulate PV end-of-life management in the United States. The model explores how the decisions of the various actors involved in handling PV waste affect the quantities of PV that are reused, recycled, or land-filled. In the model, manufacturers, residential, and nonresidential PV owners, installers, and recyclers are represented by agents while governmental policies and regulations are treated as exogenous variables. PV-market data are used to define agents' characteristics (e.g., installed PV capacities or producing costs). Agents' decision rules draw on the literature related to industrial symbiosis (IS) and peoples' waste behaviors as they appear as the most widely used model to implement CE principles at a meso level. Specifically, the concepts of mutual trust between IS actors and knowledge about the IS philosophy are yielded to define the agents' decision process. The primary outputs of the ABM are the costs and volume of waste associated with each end-of-life pathway. Preliminaries results indicate recycling of residential PV is affected by the cost, perceived difficulty of recycling behaviors, and social norms. Moreover, the type of network connecting agents and the initial recycling rate strongly influence results. The model also highlights the crucial role of recycling behavior adoption: in case of early failure of PV, recycled volumes increase by about 40%. This represents an additional 5.7 billion USD from potential recovered silver. Finally, although results for the PV case are presented here, the developed ABM aims at being a general tool for the study of CE strategies and the CE transition. Furthermore, steps of this research include extending the model to encompass circular economy strategies (e.g., design for recycling or lifetime extension) and validating its general architecture from various case studies.

14 SOLAR ENERGY↗

Breakeven Prices for Photovoltaics on Supermarkets in the United States

The photovoltaic (PV) breakeven price is the PV system price at which the cost of PV-generated electricity equals the cost of electricity purchased from the grid. This point is also called 'grid parity' and can be expressed as dollars per watt ($\$$W) of installed PV system capacity. Achieving the PV breakeven price depends on many factors, including the solar resource, local electricity prices, customer load profile, PV incentives, and financing. In the United States, where these factors vary substantially across regions, breakeven prices vary substantially across regions as well. In this study, we estimate current and future breakeven prices for PV systems installed on supermarkets in the United States. We also evaluate key drivers of current and future commercial PV breakeven prices by region. The results suggest that breakeven prices for PV systems installed on supermarkets vary significantly across the United States. Non-technical factors -- including electricity rates, rate structures, incentives, and the availability of system financing -- drive break-even prices more than technical factors like solar resource or system orientation. In 2020 (where we assume higher electricity prices and lower PV incentives), under base-case assumptions, we estimate that about 17% of supermarkets will be in utility territories where breakeven conditions exist at a PV system price of $\$$3/W; this increases to 79% at $\$$1.25/W (the DOE SunShot Initiative's commercial PV price target for 2020). These percentages increase to 26% and 91%, respectively, when rate structures favorable to PV are used.

14 SOLAR ENERGY↗

Impacts of Voltage-Based Grid Support Functions on Energy Production of PV Customers

This paper presents the impact of inverter grid- support functions (GSFs) on photovoltaic (PV) customer energy production on a real distribution feeder in Oahu, HI. These autonomous GSFs based on local voltage measurements are good alternatives to increase PV hosting capacity. However, these functions can result in PV energy curtailment to the customer, and this study addresses the concerns about the impact of inverter GSFs through detailed quasi-static time series (QSTS) simulations. It proposes four metrics: maximum and average GSF curtailment, average increased generation and average net generation change, to assess the impact of a given control on PV systems located on customer sites. It was found that curtailment of PV production is negligible for customers where peak voltage is within ANSI C84.1 range. A reliable relationship between curtailment and peak customer voltage is demonstrated, suggesting that peak voltage could be used as an indicator of customer curtailment.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Endogenous Assessment of the Capacity Value of Solar PV in Generation Investment Planning Studies. Draft

There exist several different reliability- and approximation-based methods to determine the capacity contribution of solar resources towards resource adequacy. However, most of these approaches require knowing in advance the installed capacities of both conventional and solar generators. This is a complication since generator capacities are actually decision variables in capacity planning studies. In this article we study the effect of time resolution and solar PV penetration using a capacity planning model that accounts for the full distribution of generator outages and solar resource variability. We also describe a modification of a standard deterministic planning model that enforces a resource adequacy target through a reserve margin constraint. Our numerical experiments show that at least 50 days worth of data are necessary to approximate the results of the full-resolution model with a maximum error of 2.5% on costs and capacity. We also show that the amount of displaced capacity of conventional generation decreases rapidly as the penetration of solar PV increases. We find that using an exogenously defined and constant capacity factor based on time-series data can yield relatively accurate results for small penetration levels (less than 5%). For higher penetration levels (up to 20%), the modified deterministic planning model better captures avoided costs and the decreasing value of solar PV. Although our results are not general, they highlight the importance of accounting for the variation in both energy and capacity value of solar resources endogenously in capacity planning models. A11 numerical experiments are performed using the IEEE Reliability Test System and 7 years worth of demand and solar data from a utility in Arizona.

14 SOLAR ENERGY↗

Photovoltaic Hosting Capacity of Feeders with Reactive Power Control and Tap Changers

This paper proposes an algorithm to determine photovoltaic (PV) hosting capacity of power distribution networks as a function of number of PV injection nodes, reactive power support from the PVs, and the sub-station load tap changers (LTCs). In the proposed method, several minute by minute simulations are run based on randomly chosen PV injection nodes, daily PV output profiles, and daily load profiles from a pool of high-resolution realistic data set. The simulation setup is built using OpenDSS and MATLAB. The performance of the proposed method is investigated in the IEEE 123-node distribution feeder for multiple scenarios. The case studies are performed particularly for one, two, five and ten PV injection nodes, and looking at the maximum voltage deviations. Case studies show that the PV hosting capacity of the 123-node feeder greatly differs with the number of PV injection nodes. We have also observed that the PV hosting capacity increases with reactive power support and higher tap position of sub-station LTC.

14 SOLAR ENERGY↗

Estimating Spatial Distribution Impacts of Rooftops Solar PV on Dynamic Hosting Capacity Evaluation for a Real Distribution Feeder

This paper models the sensitivity of dynamic hosting capacity analysis to the spatial distribution of distributed PV scenarios, random, close and far from substation deployments, at various penetration levels on a real distribution feeder, in a quasi-static time series (QSTS) power flow simulation using high resolution time-aware metrics. These spatial distribution scenarios were chosen to capture a wide range of potential operation impacts of these deployments using a set of thermaland voltage-based metrics such as instantaneous violations and moving averages for both thermal and voltage constraints. This study uses actual load and PV data up-scaled from 1-hour time step to 1-minute resolution to fully characterize the interaction between the daily changes in load and PV output, and their impacts on distribution system operations.

distribution system↗

A novel framework for hosting capacity analysis with spatio-temporal probabilistic voltage sensitivity analysis

Smart grids are envisioned to accommodate high penetration of distributed photovoltaic (PV) generation, which may cause adverse grid impacts in terms of voltage violations. Therefore, PV Hosting capacity is being used as a planning tool to determine the maximum PV installation capacity that causes the first voltage violation and above which would require infrastructure upgrades. Additionally, traditional methods of Hosting capacity analysis are scenario based and computationally complex as they rely on iterative load flow algorithms that require investigating a large number of scenarios for accurate assessment of PV impacts. Therefore, this paper presents a computationally efficient analytical approach to compute the probability distribution of voltage change due to random behavior of randomly located multiple distributed PVs. The proposed approach is based on Spatio-temporal probabilistic voltage sensitivity analysis that exploits both spatial and temporal uncertainties associated with PV injections. Thereafter, the derived distribution is used to quantify voltage violations for various PV penetration levels and subsequently determine the hosting capacity of the system without the need to examine large number of scenarios. Results of the proposed framework are validated via conventional load flow based simulation approach on the IEEE 37 and IEEE 123 node test systems.

42 ENGINEERING↗

Utility-Scale Solar, 2023 Edition: Empirical Trends in Deployment, Technology, Cost, Performance, PPA Pricing, and Value in the United States [Slides]

Berkeley Lab’s “Utility-Scale Solar, 2023 Edition” presents analysis of empirical plant-level data from the U.S. fleet of ground-mounted photovoltaic (PV), PV+battery, and concentrating solar-thermal power (CSP) plants with capacities exceeding 5 MWAC (PV plants of 5 MWAC or less, including residential rooftop systems, are covered separately in Berkeley Lab’s companion annual report, Tracking the Sun). Highlights of this year’s update include: -10.4 GWAC of new utility-scale PV capacity came online in 2022, bringing cumulative installed capacity to more than 61.7 GWAC across 46 states. -94% of all new utility-scale PV capacity added in 2022 uses single-axis tracking. -Median installed project costs declined to $\$1.32$/WAC (or $\$1.07$/WDC) in 2022. -Plant-level capacity factors vary widely, from 9% to 35% (on an AC basis), with a sample median of 24%. The report explores drivers of this variation. -Utility-scale PV’s LCOE fell to $\$39$/MWh in 2022 ($\$29$/MWh if factoring in the federal investment tax credit, or ITC). -PPA prices have largely followed the decline in solar’s LCOE over time, but have recently stagnated and even moved slightly higher. Prices from a sample of recent contracts average around $\$20-30$/MWh (levelized) in the West and $\$30-40$/MWh elsewhere in the continental US. -In 2022, solar’s average market value (defined in the report to include only energy and capacity value) rose by 40% to $\$71$/MWh and exceeded average wholesale prices in 4 of the 7 ISOs/RTOs and 11 of 18 other balancing authorities analyzed. -Adding battery storage is one way to increase the value of solar. Our public data file tracks metadata and PPA prices from ~100 PV+battery hybrid projects that are already online or that have secured offtake arrangements. -the end of 2022, there were at least 947 GW of utility-scale solar power capacity within the interconnection queues across the nation, 456 GW of which include batteries. For more information, and to explore related interactive data visualizations, go to utilityscalesolar.lbl.gov.

14 SOLAR ENERGY↗

Is $50/MWh solar for real? Falling project prices and rising capacity factors drive utility-scale PV toward economic competitiveness

Recently announced low-priced power purchase agreements (PPAs) for US utility-scale photovoltaic (PV) projects suggest $50/MWh solar might be viable under certain conditions. To explore this possibility, this paper draws on an increasing wealth of empirical data to analyze trends in three of the most important PPA price drivers: upfront installed project prices, operations, and maintenance (O&M) costs, and capacity factors. Average installed prices among a sample of utility-scale PV projects declined by more than one third (from 5.8/W AC to 3.7/WAC) from the 2007–2009 period through 2013, even as costlier systems with crystalline-silicon modules, sun tracking, and higher inverter loading ratios (ILRs) have constituted an increasing proportion of total utility-scale PV capacity (all values shown here are in 2013 dollars). Actual and projected O&M costs from a very small sample of projects appear to range from $20–$40/kW AC -year. Furthermore, the average net capacity factor is 30% for projects installed in 2012, up from 24% for projects installed in 2010, owing to better solar resources, higher ILRs, and greater use of tracking among the more recent projects. Based on these trends, a pro-forma financial model suggests that $50/MWh utility-scale PV is achievable using a combination of aggressive-but-achievable technical and financial input parameters (including receipt of the 30% federal investment tax credit). Although the US utility-scale PV market is still young, the rapid progress in the key metrics documented in this paper has made PV a viable competitor against other utility-scale renewable generators, and even conventional peaking generators, in certain regions of the country.

14 SOLAR ENERGY↗

Endogenous Assessment of the Capacity Value of Solar PV in Generation Investment Planning Studies

There exist several different reliability-and approximation-based methods to determine the contribution of solar resources toward resource adequacy. However, most of these approaches require knowing in advance the installed capacities of both conventional and solar generators. This is a complication since generator capacities are actually decision variables in capacity planning studies. In this paper, we study the effect of time resolution and solar PV penetration using a planning model that accounts for the full distribution of generator outages and solar resource variability. We also describe a modification of a standard deterministic planning model that enforces a resource adequacy target through a reserve margin constraint. Our numerical experiments show that at least 50 days worth of data are necessary to approximate the results of the full-resolution model with a maximum error of 2.5% on costs and capacity. We also show that the amount of displaced capacity of conventional generation decreases rapidly as the penetration of solar PV increases. We find that using an exogenously defined and constant capacity value based on time-series data can yield relatively accurate results for small penetration levels. For higher penetration levels, the modified deterministic planning model better captures avoided costs and the decreasing value of solar PV.

14 SOLAR ENERGY↗

High Penetration of Photovoltaic Generation Study – Flagstaff Community Power (Final Technical Report, Results of Phases 2-5)

APS’s renewable energy portfolio, driven in part by Arizona’s Renewable Energy Standard (RES) currently includes more than 1100 MW of installed capacity, equating to roughly 3000 GWh of annual production. Overall renewable production is expected to grow to 6000 GWh by 2025. It is expected that distributed photovoltaics, driven primarily by lower cost, will contribute to much of this growth and that by 2025, distributed installations will account for half of all renewable production (3000GHW). As solar penetration increases, additional analysis may be required for routine utility processes to ensure continued safe and reliable operation of the electric distribution network. Such processes include residential or commercial interconnection requests and load shifting during normal feeder operations. Circuits with existing high solar penetration will also have to be studied and results will need to be evaluated for adherence to utility practices or strategy. Increased distributed PV penetration may offer benefits such as load offsetting, but it also has the potential to adversely impact distribution system operation. These effects may be exacerbated by the rapid variability of PV production. Detailed effects of these phenomena in distributed PV applications continue to be studied. Comprehensive, high-resolution electrical models of the distribution system were developed to analyze the impacts of PV on distribution circuit protection systems (including coordination and anti-islanding), predict voltage regulation and phase balance issues, and develop volt/VAr control schemes. Modeling methods were refined by validating against field measurements. To augment the field measurements, methods were developed to synthesize high resolution load and PV generation data to facilitate quasi-static time series simulations. The models were then extended to explore boundary conditions for PV hosting capability of the feeder and to simulate common utility practices such as feeder reconfiguration. The modeling and analysis methodology was implemented using open source tools and a process was developed to aid utility engineers in future interconnection requests. Methods to increase PV hosting capacity were also explored during the course of the study. A 700kVA grid-supportive inverter was deployed on the feeder and each grid support mode was demonstrated. Energy storage was explored through simulation and models were developed to calculate the optimum size and placement needed to increase PV hosting capacity. A tool was developed to aid planners in assigning relative costs and benefits to various strategies for increasing PV hosting capacity beyond current levels. Following the completion of the project, APS intends to use the tools and methods to improve the framework of future PV integration on its system. The tools and methods are also expected to aid other utilities to accelerate distributed PV deployment.

14 SOLAR ENERGY↗

Sequential Mitigation Solutions to Enable Distributed PV Grid Integration

This paper presents a method to assess the technical impacts of a series of distribution system mitigations for integrating increasing penetrations of distributed generation from solar photovoltaics (DGPV). Solutions considered include distribution grid upgrades and advanced control technologies. This study helps pave the way to estimate the distribution integration costs needed to reach various PV penetration levels. The approach uses three stream-lined, bounding scenarios for increased PV penetration patterns. It begins by studying the distribution impact of PV power and quantifying the PV hosting capacity. Then, it studies multiple mitigation solutions to increase PV penetration on distribution feeders. These mitigation solutions are implemented in a sequential manner according to their typical costs. The proposed technique is demonstrated on two representative distribution feeders.

14 SOLAR ENERGY↗