Evaluating the Durability of Balance of Systems Components Using Combined-Accelerated Stress Testing

The degradation of photovoltaic (PV) balance of systems (BoS) components is not well-studied, but the consequences include offline modules, strings, and inverters; system shutdown; arc faults; and fires. A utility provider experienced a ~30% failure rate in their power transfer chain, originally attributed to branch connectors. Field-failed specimen assemblies were therefore examined, consisting of cable connector, branch connector, and discrete fuse components. Previous papers and presentations have focused on the development of the test method using a benchtop prototype. This presentation covers the early results of C-AST aging of static and dynamic specimens.

balance of systems↗

UV Degradation in Backsheets: A Ray-Tracing Irradiance Simulation Approach

Around 90% of current photovoltaic (PV) modules are less than ten years old. New PV technologies and materials are deployed without documented durability and performance histories. Accelerated testing attempts to capture degradation modes but can produce false results with such rapid deployment of new materials. Current testing assumes UV dosage on the rear of a module to be 10% of that incident on the front. We present a method to quantify degradation on PV backsheets in the field. We aim to evaluate if current acceleration factors for UV damage in chambers are properly estimating degradation for different PV site installations. The method leverages bifacial_radiance to ray-trace and evaluate irradiance on the front and the rear of the modules. Then an equation to estimate the relative degradation is proposed.

accelerated testing↗

First principles modeling of polymer encapsulant degradation in Si photovoltaic modules

An outstanding issue in the longevity of photovoltaic (PV) modules is the accelerated degradation caused by the presence of moisture. Moisture leads to interfacial instability, de-adhesion, encapsulant decomposition, and contact corrosion. However, experimental characterization of moisture in PV modules is not trivial and its impacts can take years or decades to establish in the field, presenting a major obstacle to designing high-reliability modules. First principles calculations provide an alternative way to study the ingress of water and its detrimental effect on the structure and decomposition of the polymer encapsulant and interfaces between the encapsulant and the semiconductor, the metal contacts, or the dielectric layer. Here, we use density functional theory (DFT) computations to model single chain, crystalline and cross-linked structures, infrared (IR) signatures, and degradation mechanisms of ethylene vinyl acetate (EVA), the most common polymer encapsulant used in Si PV modules. IR-active modes computed for low energy EVA structures and possible decomposition products match well with reported experiments. The EVA decomposition energy barriers computed using the Nudged Elastic Band (NEB) method show a preference for acetic acid formation as compared to acetaldehyde, are lowered in the presence of a water solvent or hydroxyl ion catalyst, and match well with reported experimental activation energies. This systematic study leads to a clear picture of the hydrolysis-driven decomposition of EVA in terms of energetically favorable mechanisms, possible intermediate structures, and IR signatures of reactants and products.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Photovoltaic Inverter Failure Mechanism Estimation Using Unsupervised Machine Learning and Reliability Assessment

This article introduces a data-driven approach to assessing failure mechanisms and reliability degradation in outdoor photovoltaic (PV) string inverters. The manufacturer's stated PV inverter lifetime can vary due to the impact of operating site conditions. To address limitations in degradation estimation through accelerated testing, condition monitoring, or degradation modeling, we propose a machine learning (ML) oriented approach. Utilizing data from a 1.4 MW PV power plant operational since 2016, with 46 string PV inverters tied to the grid, we employ the unsupervised one-class support vector machine ML technique to analyze inverter and sensor data, capable of classifying humidity cycling and temperature fluctuations as dominant failure mechanisms. Utilizing the anomaly alert relationship and alert details specific to the inverter, the level of PV inverter output is considered as its availability or available reliability. Subsequently, a continuous Markov model is applied to six-month alert data, revealing an average stated reliability of 20% after 20 years of continuous operation. These results support recommendations for time-bound preventive measures to enhance PV inverter reliability under diverse outdoor conditions. Furthermore, the approach provides a nondestructive, top–down, and generalized method for analyzing any commercial PV inverter exposed to outdoor conditions, contingent on the availability of relevant data.

14 SOLAR ENERGY↗

Enhancing lifetime, forecasting, and economic benefits of photovoltaic technologies undergoing UV-induced degradation with optical filtering

Ultraviolet-induced degradation (UV-ID) of various PV cell types was analyzed under optical UV filters with different cutoff wavelengths. Cell types studied included interdigitated back contact (IBC), passivated emitter and rear totally diffused (PERT), and heterojunction technology (HJT) based on crystalline Si (c-Si), and metal halide perovskite (MHP) cells. Analyzing degradation rates in two distinct regimes proved beneficial for all cell types. We used empirical linearizing functions ln(t) for c-Si technologies and 2 √t for MHP samples where t is time. These were applied to extrapolate UV-induced degradation over the lifetime of PV modules under various levels of optical UV filtering and used to predict the relative economic benefits for PV power plants. Degradation rates for all technologies were generally faster under the long pass optical filters having shorter cutoff wavelengths transmitting more UV irradiation and at elevated temperatures when testing MHP samples in the range between 60 °C and 90 °C.

14 SOLAR ENERGY↗

Glass/glass photovoltaic module reliability and degradation: a review

Glass/glass (G/G) photovoltaic (PV) module construction is quickly rising in popularity due to increased demand for bifacial PV modules, with additional applications for thin-film and building-integrated PV technologies. G/G modules are expected to withstand harsh environmental conditions and extend the installed module lifespan to greater than 30 years compared to conventional glass/backsheet (G/B) modules. With the rapid growth of G/G deployment, understanding the outdoor performance, degradation, and reliability of this PV module construction becomes highly valuable. In this review, we present the history of G/G modules that have existed in the field for the past 20 years, their subsequent reliability issues under different climates, and methods for accelerated testing and characterization of both cells and packaging materials. We highlight some general trends of G/G modules, such as greater degradation when using poly(ethylene-co-vinyl acetate) (EVA) encapsulants, causing the industry to move toward polyolefin-based encapsulants. Transparent backsheets have also been introduced as an alternative to the rear glass for decreasing the module weight and aiding the effusion of trapped gaseous degradation products in the laminate. New amendments to IEC 61215 standard protocols for G/G bifacial modules have also been proposed so that the rear side power generation and UV exposure will be standardized. We further summarize a suite of destructive and non-destructive characterization techniques, such as current-voltage scans, module electro-optical imaging, adhesion tests, nanoscale structural/chemical investigation, and forensic analysis, to provide deeper insights into the fundamental properties of the module materials degradation and how it can be monitored in the G/G construction. This will set the groundwork for future research and product development.

14 SOLAR ENERGY↗

Network Models of Active Degradation Mechanisms and Pathways for Service Life Prediction of Indoor and Outdoor PV Modules

ct: PV service lifetime prediction (SLP) enables accurate calculation of levelized cost of energy (LCOE), which is crucial to rationalizing PV investment and installation. However, SLP is challeging since PV reliability in the field is affected by many combined factors, including various environmental stresses and module quality. In order to map out the active degradation mechanisms and pathways that best resemble real world conditions, we introduce the framework of a study protocol and use network models fitted to data, to enable analysis and SLP of complex PV systems with multiple active degradation mechanisms. The study protocol is the experimental design, including module variants and different exposure conditions, selection of evaluation methods, time-series data acquisition and training of network models to these data. We present SLP of minimodules in the lab and PV systems in the field. For lab SLP, minimodules with 8 variants based on manufacturer, architecture, and encapsulation were prepared and aged in modified damp heat with or without full spectrum light exposure. Stepwise I-V and Suns-Voc data acquisition tracks changes in electrical properties including Rs,IV, Isc,IV, Vmp,PIV providing insights into power loss of minimodules. Network structural equation modeling (netSEM) was utilized to construct degradation pathway models that identify active degradation mechanisms and predict power loss over time. For field SLP, datastreams of Pmp values and I-V curve datastreams of two types of modules installed in three distinctly different Köppen-Geiger climate zones for 9 years were acquired. With power loss modes corresponding to uniform current loss (ΔPIsc), recombination (ΔPVoc), series resistance (ΔPRs), and current mismatch (ΔPImis) determined, the performance loss rates (PLR) were determined using PVplr. We show how to establish a study protocol framework to ensure appropriate parametric variations and valid data collection from the variants of your complex systems. Then the data-driven netSEM model fitting provides a comprehensive mapping of multiple active degradation mechanisms, and accurate service life prediction.

network model, degradation, photovoltaic, solar↗

Numerical Validation of an Algorithm for Combined Soiling and Degradation Analysis of Photovoltaic Systems

We describe and demonstrate an open-source algorithm for simultaneously quantifying degradation and soiling of photovoltaic (PV) systems from energy-production time series data. The new analysis is based on year-on-year degradation rate analysis combined with stochastic rate and recovery soiling analysis. The algorithm is designed to fit into the workflow provided by RdTools, a Python module maintained by NREL and collaboratively developed with the community, which provides a framework and functions for degradation and loss-factor analysis of PV field data. We demonstrate the method on numerically simulated PV data sets and show that it reduces the root-mean-square error of the P50 degradation rate estimate when soiling is present.

14 SOLAR ENERGY↗

Thermal behaviors of ethylene vinyl acetate encapsulants in fielded silicon photovoltaic modules

Aging of silicon photovoltaic (PV) module packaging is one of the greatest limiters of PV module service lifetimes. Module characterization typically focuses on power degradation metrics, which do not convey the complexities of often simultaneous degradation mechanisms. In this work, PV modules with pristine references and known fielding histories were investigated by non-destructive and destructive methods. Modules from Canadian Solar, Mission Solar, and Hanwha Q-Cells were fielded for up to three years; select modules were removed from fielding each year for coring to allow for characterization of the encapsulant. Modules are commonly encapsulated with two protective layers of partially-crystalline ethylene vinyl acetate (EVA) polymer that must undergo a crosslinking reaction to achieve desired properties. The extent of crystallinity of the encapsulants as studied by differential scanning calorimetry showed differences between manufacturers and over time. Some encapsulants showed different magnitudes of crystal sizes which changed after fielding; encapsulants with the monodisperse crystal sizes did not change with fielding. This is due to differences in thermal history. In conclusion, these results have implications for stress development during module aging, since EVA crystal melting and crosslinking reactions can result in encapsulant density changes.

36 MATERIALS SCIENCE↗

Photovoltaic fleet degradation insights

Abstract In the PV Fleet Performance Data Initiative, high‐frequency data from commercial and utility‐scale photovoltaic (PV) systems have been collected to examine performance loss rates (PLRs) at a fleet scale. To date, performance data from more than 7.2‐gigawatt (GW) capacity, 1700 sites and 19,000 inverters—approximately equivalent to 6% to 7% of the entire US PV market—have been collected. An overall PLR of −0.75%/year was found, which is in line with historical and recent findings. Tracked silicon (Si) and cadmium telluride (CdTe) performed comparably with all fixed‐tilt systems. Higher PLRs were found for hotter temperature zones; cooler climates exhibit a median −0.48%/year loss, which increases to −0.88%/year in hotter climates. High‐efficiency module technologies showed median PLRs in line with conventional Si technologies but demonstrated markedly different PLR behavior when filtered only for low‐light conditions <600 W/m 2 . Causes for this technology‐dependent behavior are under investigation.

14 SOLAR ENERGY↗

Assessment of Accelerated Stress Testing Data for Silicon Photovoltaics Using Tensor Decomposition Methods

In this work, we examine the use of high-order tensor decompositions to analyze degradation pathways emerging from accelerated stress testing of silicon photovoltaic (PV) modules. Matrix-based decompositions are powerful tools for studying two-dimensional data arrays and form the foundation of a host of classical data analysis techniques. Tensors are high-order extrapolations of matrices that are able to account for more parameter dimensions, and a variety of tensor decomposition methods have been developed that similarly seek to extend insights from matrix decompositions to higher dimensions. Applying and interpreting tensor decomposition methods to sequences of PV module image data, we seek to uncover and isolate different degradation modes occurring from accelerated stress testing procedures. Further, we consider the contributions of different modes to PV module performance degradations.

data analysis↗

Low-Temperature Gold Deposition Improves CdTe Back Contacts

Improved back contacts can benefit CdTe photovoltaics (PV). In this work, Cd(Se,Te) PV absorbers are cooled during Au evaporation to thermally quench a chemical reaction occurring between gold and CdTe and the generation of a reaction product that lowers device efficiency. Reducing substrate temperature enhances PV power conversion efficiency via open-circuit voltage and fill factor increases. X-ray photoelectron spectroscopy (XPS) reveals that lower temperature also reduces chemical perturbations of the CdTe, potentially linking back contact formation to a CdTe degradation product that hinders PV performance. Comparing reaction enthalpy and substrate heating energy shows that back contact formation by sputtering elemental metals onto ZnTe may exhibit a degradation pathway analogous to that of CdTe/Au reported here. Degradation-diminishing contact formation processes are therefore of general interest for optoelectronic devices, and the reduced substrate temperature in this study is one example.

14 SOLAR ENERGY↗

Plant-level performance and degradation of 31 GW DC of utility-scale PV in the United States

In this updated study, which samples 50% more capacity than the original and adds two additional years of operating history, we assess the performance of a fleet of 631 utility-scale PV plants totaling 31.0 GW DC (23.6 GW AC ) of capacity that achieved commercial operations in the United States from 2007-2018 and that have operated for at least two full calendar years. We use detailed information on individual plant characteristics, in conjunction with modeled irradiance data, to model expected or “ideal” capacity factors in each full calendar year of each plant’s operating history. A comparison of ideal versus actual first-year capacity factors finds that this fleet has modestly underperformed initial expectations (as modeled) on average, though perhaps due as much to modeling issues as to actual underperformance. We then analyze fleet-wide performance degradation in subsequent years by employing a “fixed effects” regression model to statistically isolate the impact of age on plant performance. The resulting average fleet-wide degradation rate of -1.2%/year (±0.1%) represents a slight improvement (seemingly driven by the oldest plants in our sample) over the -1.3%/year (±0.2%) found in our original study, yet is still of greater magnitude than is commonly found. We emphasize, however, that these fleet-wide estimates reflect both recoverable and unrecoverable degradation across the entire plant, and so will naturally be of greater magnitude than module- or cell-level studies, and/or studies that focus only on unrecoverable degradation. Moreover, when focusing on a sub-sample of newer and larger plants with higher DC:AC ratios—i.e., plants that more-closely resemble what is being built today—we find a more moderate sample-wide average performance decline of -0.7%/year (±0.4%), which is more in line with other estimates from the recent literature.

14 SOLAR ENERGY↗

PV Durability at Scale: Assessing Bifacial and TOPCon Field Performance

Recent field performance results of TOPCon and PERC Bifacial modules are presented based on small-scale deployments at NLR, and a selection of 3rd-party residential data. Bifacial PERC degradation rates are a median of -1 % / yr with bifacial TOPCon modules at a similar rate of -1.1 %/yr over the first couple of years. Comparable PERC Monofacial modules have a degradation rate of -0.5%/yr. Some TOPCon modules exhibited an indoor dark metastability effect which requires recovery by light soaking or UV exposure prior to IV curve measurement. Further monitoring is needed to confirm the long-term stability of TOPCon modules.

14 SOLAR ENERGY↗

Glass/Glass Photovoltaic Module Reliability and Degradation: A Review - Figures

Glass/glass (G/G) photovoltaic (PV) module construction is quickly rising in popularity due to increased demand for bifacial PV modules, with additional applications for thin-film and building-integrated PV technologies. G/G modules are expected to withstand harsh environmental conditions and extend the installed module lifespan to greater than 30 years compared to conventional glass/backsheet (G/B) modules. With the rapid growth of G/G deployment, understanding the outdoor performance, degradation, and reliability of this PV module construction becomes highly valuable. In this review, we present the history of G/G modules that have existed in the field for the past 20 years, their subsequent reliability issues under different climates, and methods for accelerated testing and characterization of both cells and packaging materials. We highlight some general trends of G/G modules, such as greater degradation when using poly(ethylene-co-vinyl acetate) (EVA) encapsulants, causing the industry to move toward polyolefin-based encapsulants. Transparent backsheets have also been introduced as an alternative to the rear glass for decreasing the module weight and aiding the effusion of trapped gaseous degradation products in the laminate. New amendments to IEC 61215 standard protocols for G/G bifacial modules have also been proposed so that the rear side power generation and UV exposure will be standardized. We further summarize a suite of destructive and non-destructive characterization techniques, such as current-voltage scans, module electro-optical imaging, adhesion tests, nanoscale structural/chemical investigation, and forensic analysis, to provide deeper insights into the fundamental properties of the module materials degradation and how it can be monitored in the G/G construction. This will set the groundwork for future research and product development.

transparent backsheet↗

Evaluation of Surface Crack Formation in Photovoltaic Backsheets Using Fragmentation and Finite Element Simulations: Preprint

Backsheet cracking is among the most commonly observed degradation modes of photovoltaic (PV) modules in the field. Cracks can reduce the ability of backsheets to fulfil their functions, for example, protection of the modules from the environment or electrical insulation. This work presents an evaluation of the degradation and cracking propensity of two backsheets during accelerated IEC TS 62788-7-2 A3 (International Electrotechnical Commission) aging with the fragmentation test: a co-extruded polyamide backsheet (AAA), and a laminated multilayer backsheet with a polyethylene terephthalate core and outer layer and ethylene vinyl acetate inner layer (PPE). Results show the surface embrittlement of the AAA outer layer during exposure. A longer time of exposure causes cracks to form at lower strains during stretching and creates deeper cracks. Accordingly, Young's modulus of the outer layer increases, as measured by cross-sectional nanoindentation. PPE exhibits cracking after exposure as well. While no similar increase of modulus or crack depth can be observed, the outer layer of PPE exhibits more obvious signs of erosion during exposure, including progressive morphological changes and thickness losses. A finite element model to simulate surface crack formation is devised, based on initially zero-thickness decohesion elements. Decohesion criteria define a critical stress, at which these elements grow, and cracks can begin to form. These criteria are obtained via parameter optimization by comparison between simulation and experiment. The model is used to interpret crack formation in both backsheets.

backsheet↗

Power Electronics Based Self-Monitoring and Diagnosing for Photovoltaics Systems

Self-monitoring and diagnosing technology for photovoltaic (PV) systems is a method to reduce energy production losses. The proposed technology will enable existing panel-level power optimizers and inverters in a PV system to actively perturb the system, measure its response to these small-signal perturbations, and detect any changes in the small-signal impedances. Impedance measurement will be used to identify specific faults and power degradation trends in a PV panel. This information can be used to instantly alert Operations and Maintenance (O&M) personnel of the need for corrective action, thereby reducing energy production losses earlier relative to standard PV systems.

Panchal, Jeet↗