Adaptive Protection and Validated Models to Enable Deployment of High Penetrations of Solar PV (PV-MOD)

The availability and validation of various PV models in commercial tools differ, with some models not yet thoroughly validated for advanced inverter functionalities and reliable performance under weak system conditions. Many existing models do not fully incorporate new inverter control functions, which can affect system stability. The increasing deployment of solar PV and other inverter-based resources (IBRs), including distributed energy resources (DERs), is influencing the reliable operation of protection schemes in distribution systems and microgrids. Emerging adaptive protection schemes (APS) offer new opportunities for protecting these systems during varying configurations and DER operating conditions, though their demonstration and validation remain limited. Adaptive protection schemes face similar challenges, as they are typically designed for specific configurations. There is a growing need for tools and methodologies to streamline the deployment of adaptive protection for safe and reliable DER integration. The project main objective was to develop and validate high-fidelity generic models of solar PV facilities for stability, protection, EMT, and QSTS analyses. This objective was achieved, and these models can now be integrated into commercial software tools, enabling utilities, vendors, and developers to study high-penetration PV systems more confidently. The project also demonstrated advanced applications of these models, including the design and deployment of adaptive protection schemes in high-penetration field applications and microgrids, supporting grid safety and reliability. Several milestones were reached by the end of the project. A sophisticated inverter test plan was developed, and inverters representative of the North American marketplace were selected. EPRI and NREL tested various inverters, conforming to IEEE standards. Improvements were made to existing generic models of IBR units, IBR plants, and aggregated feeders for various analyses. The first generic electromagnetic transient (EMT) model for a solar PV plant was developed, conforming to IEEE Std 2800™-2022 and validated against laboratory measurements of a 2.2 MVA large-scale battery energy storage system (BESS) inverter. That model was then used to produce reference responses illustrating examples of validated and verified IBR plant models that pass or fail tests for technical minimum capability and performance as specified in the IEEE standard. The developed, tested, and validated generic models can be used for transmission planning, stability assessments, expansion planning, and evaluating potential future IBR interconnection requirements. They can also support interconnection screens and conformity assessments of IBR plants, including solar PV. The project significantly contributed to the ongoing standardization and model-based representation and verification of IBR responses. The project further addressed challenges of common distribution protection schemes with increasing deployment of DER by developing, validating, and demonstrating adaptive protection schemes (APS) that can improve the reliable and safe integration of DER into distribution systems. New APS were designed using improved DER models for three common distribution systems: a radial feeder, a meshed network, and a microgrid. Modeling and hardware-in-the-loop (HIL) testing of the APS were conducted, successfully showing their effectiveness and selectivity. Proof-of-concept field demonstration was achieved for two APS, i.e., one on a radial feeder and another one in a microgrid. Field demonstration could not be achieved for the APS on a meshed network, primarily due apprehension of one utility partner and also due to limited access to the protective algorithms in the network protectors. Guidelines developed from the lessons learned in the project lay out the general process followed in the design, installation, and commissioning of APS for various distribution systems. Distribution utility partners’ apprehension about field demonstration of the new APS were addressed—with varying success—by taking a stepped risk-management approach of modeling of a wide range of sensitivities first, performing in-depth proof-of-concept testing in the laboratory including HIL next, and finally deliberately implementing and commissioning the actual protection equipment and algorithms into parts of—or in parallel operation to—the three real distribution systems. Future work should include pilot projects that further show the acceptable performance of the developed APS before these schemes be rolled out more widely. Inclusion of both utility and original equipment manufacturers (OEMs) in future projects could increase chances of successful field demonstration. Despite challenges in achieving the field demonstration goal of the project for all three APS, the research significantly contributed to the innovation of adaptive protection solutions for scalable and reliable DER integration into distribution systems. This project significantly enhances the understanding of the impact of using appropriate inverter models on distribution and transmission (T&D) systems. By addressing the limitations of existing generic models, the project introduces high-fidelity models for stability, protection, electromagnetic transient (EMT), and quasi-static time series (QSTS) analyses. These models, integrated into commercial software tools, enable utilities, vendors, and developers to confidently study high-penetration PV systems. The project also demonstrates advanced applications, including adaptive protection schemes (APS) for distribution systems and microgrids, ensuring grid safety and reliability. The technical effectiveness and economic feasibility of the methods are evident through the development and validation of sophisticated inverter test plans and the selection of representative inverters. Testing by EPRI and NREL on retail, commercial, and utility-scale inverters, conforming to IEEE standards, underscores the robustness of the models. Improvements to existing generic models for various analyses further enhance their validity and applicability. The project also identifies gaps in common distribution protection schemes and designed new APS using improved DER models, demonstrating their effectiveness through modeling and hardware-in-the-loop (HIL) testing. The project’s benefits to the public are manifold. By advancing the standardization and model-based representation of IBR response, it supports transmission planning, stability assessments, and future IBR interconnection requirements. The generic models can facilitate better communication between transmission planners and developers, supporting expected IBR plant capability and performance. Additionally, the development of APS for radial feeders, meshed networks, and microgrids supports the integration of distributed energy resources (DERs) into distribution systems, enhancing grid reliability and safety. The project’s emphasis on thorough testing and simplicity in design ensures practical and scalable solutions for DER integration.

14 SOLAR ENERGY↗

Design principles of tandem cascade photoelectrochemical devices

Cascade photoelectrocatalysis (PEC) is a possible method to improve the selectivity of solar-driven CO 2 reduction (CO 2 R). This concept can be realized by coupling different CO 2 R catalysts to different subcells in a multijunction photovoltaic (PV) stack. Efficient implementation will require careful tuning of the photocurrents and design of the photovoltages provided by the subcells to the CO 2 R catalysts in such a way as to facilitate the target reaction. Here, we outline the design principles of the tandem PEC approach using two-step conversion of CO 2 to ethylene in aqueous electrolyte, via a CO intermediate, as a model system. To perform this reaction, the first coupled PV-catalyst component should provide 4 electrons to reduce 2 molecules of CO 2 to CO; the second component should provide 8 electrons to reduce 2 CO molecules to C 2 H 4 . Based on known CO 2 R catalysts, the overpotential required to produce CO can be less than that required to reduce it to ethylene, creating the opportunity for improved efficiency. Cascade PEC can be realized in a three-terminal tandem (3TT) configuration using III–V-semiconductor based subcells coupled to Au (produces CO intermediate) and Cu (converts CO to ethylene). The current to each catalyst can be controlled by the area of the subcell exposed to the electrolyte, and the photovoltage is determined by the materials selected and device configuration. Operating conditions are found by simulating the coupled system using the open-source circuit simulator SPICE (Simulation Program with Integrated Circuits Emphasis). We identify conditions under which a 3TT configuration can have a higher solar to chemical conversion efficiency compared to a two-terminal two-junction tandem (2T 2J) with the same absorbers and a Cu catalyst only. We also show that 3TT PEC devices can be less sensitive to variations in catalyst activity compared to 2T devices. Lastly, we discuss the applications of cascade PEC to CO 2 reduction, using different intermediates, and to other chemical networks.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Time Dilated Bundt Cake Analysis of PV Output [Poster]

We present a novel method for modeling time-dependent statistics in the power signal generated by a photovoltaic (PV) system. Our white-box machine learning method is interpretable and auditable, based on principles of multiperiodic basis functions and convex optimization. Our proposed method of time dilating the daily signal to remove night time values results in a novel representation of PV power signals, evocative of a ‘Bundt cake’. The proposed model describes the marginal distribution of power output as a function of date and time. The resulting probabilistic model of a PV system can be used to perform a variety of tasks, and here, we demonstrate the application of clear sky detection.

14 SOLAR ENERGY↗

Solar and Storage Integration in the U.S. Southeast: Implications for Resource Adequacy

Resource adequacy concerns may be very different in electricity systems that have higher levels of solar and storage, requiring changes to existing planning models. This study explores a novel approach to evaluating resource adequacy under future scenarios with higher solar and storage in the Southeast U.S. It uses NREL’s Probabilistic Resource Adequacy Suite (PRAS), a collection of probabilistic resource adequacy modeling tools, and compares results when interacting PRAS and a portfolio planning tool with a more traditional modeling approach. The results suggest that traditional models perform reasonably well with lower levels of solar PV, but at higher levels of solar probabilistic tools better capture the changes in resource adequacy concerns—such as winter energy availability—associated with higher solar systems. This is the final study in the Preparing Southeast Markets for Reliable and Affordable Integration of Solar into Operations and Planning project. Two prior reports can be found at: Solar and Storage Integration in the Southeastern United States: Economics, Reliability, and Operations. https://emp.lbl.gov/publications/solar-and-storage-integration Solar and Wind Forecast Error Reserve Sharing in a Multi-Utility Region. https://eta-publications.lbl.gov/sites/default/files/2024-11/multiutility_fe_reserve_sharing_final.pdf

14 SOLAR ENERGY↗

CIGS Technology Advancement via Fundamental Modeling of Defect/Impurity Interactions (Final Technical Report)

The primary goals of the proposed work were to provide modeling tools (and the associated insight which comes along with model development) for design and optimization of CuIn x Ga 1-x Se 2 (CIGS) and CdSeTe (CST) solar cell manufacturing processes and to establish the foundation for comprehensive end-to-end predictive modeling tools to enable optimization of thin film photovoltaic technology for performance, cost, yield, and reliability. The initial focus of efforts within this project was to develop coupled process/optical/device models for CIGS PV technology and to work with Siva Power to apply that TCAD (technology computer-aided design) system to improve the efficiency and reduce manufacturing costs for CIGS solar cells. Our approach to that end was to generate an extensive database of DFT calculations and to use those calculations via statistical thermodynamics methods and Monte Carlo simulation to develop and characterize models for the behavior of native defects as well as intentional and unintentional impurities, including the redistribution of the primary components of CIGS films. Increased effort went toward coupling those models for defect behavior and composition evolution to the performance of multicrystalline CIGS solar cells via prediction of doping level and recombination lifetime as function of manufacturing process. In the second budget period, the project pivoted to developing a similar system for the CdSeTe system, focused especially on understanding the role of Se/Te alloy concentration. Execution of the project resulted in the successful development of TCAD systems for both CIGS and CdSeTe thin film PV within the Synopsys Sentaurus framework by utilizing the Alagator interface. In the first budget period of the project, we developed quantitative models for the major components of CIGS PV and implemented them within a framework that couples process, optical, and device simulation. From the insights we have gained, we identified novel opportunities for enhancing CIGS solar cell performance and have laid the groundwork to further optimize the layer structure, composition profile, and thermal cycles for substantially improved efficiency and lower manufacturing costs. For the CIGS system, process changes to achieve greater than 1% absolute enhancement in efficiency were identified, but testing of those approaches was stymied by lack of a domestic CIGS manufacturing partner after the closure of Siva Power as well as Miasole. For CdSeTe, a fully capable TCAD system only became ready to apply near the end of the project period, so substantial opportunities remain to apply those models to enhance the leading thin film PV technology.

14 SOLAR ENERGY↗

What you get is not always what you see—pitfalls in solar array assessment using overhead imagery

Effective integration planning for small, distributed solar photovoltaic (PV) arrays into electric power grids requires access to high quality data: the location and power capacity of individual solar PV arrays. Unfortunately, national databases of small-scale solar PV do not exist; those that do are limited in their spatial resolution, typically aggregated up to state or national levels. While several promising approaches for solar PV detection have been published, strategies for evaluating the performance of these models are often highly heterogeneous from study to study. The resulting comparison of these methods for practical applications for energy assessments becomes challenging and may imply that the reported performance evaluations overly optimistic. The heterogeneity comes in many forms, each of which we explore in this work: the degree of diversity of the locations and sensors (e.g. different satellites, aerial photography) from which the training and validation data originate, the validation of ground truth (manual annotation of imagery vs known solar PV locations), the level of spatial aggregation (e.g. array-level vs regional estimates), and inconsistencies in the training and validation datasets (e.g. different datasets are used for each study and those data are not always made accessible). For each, we discuss emerging practices from the literature to address them or suggest directions of future research. As part of our investigation, we evaluate solar PV identification performance in two large regions: the entire state of Connecticut and the city of San Diego, CA. In Connecticut, we also use 33,114 known parcel-level solar PV installations from Berkeley Lab’s Tracking the Sun dataset to evaluate parcel-level performance and evaluate capacity estimates using 169 municipalities. We also make our code (which we call SolarMapper), pre-trained models, training data, and predictions publicly available and provide a web portal for interactively inspecting each prediction that was made. Here our findings suggest that traditional performance evaluation of the automated identification of solar PV from satellite imagery may be optimistic due to common limitations in the validation process. The takeaways from this work are intended to inform and catalyze the large-scale practical application of automated solar PV assessment techniques by energy researchers and professionals.

14 SOLAR ENERGY↗

Selection of optimal wavelengths for optical soiling modelling and detection in photovoltaic modules

Soiling impacts the photovoltaic (PV) module performance by decreasing the amount of light reaching the photovoltaic cells and by changing their external spectral response. Currently, the soiling monitoring market is moving toward optical sensors that measure transmittance or reflectance, rather than directly measuring the impact of soiling on the performance of photovoltaic modules. These sensors, which use a single optical measurement, are not able to correct the soiling losses that depend on the solar irradiance spectra and on the spectral response of the monitored PV material. This work investigates methods that can improve the optical detection of soiling by extracting the full soiling spectrum profiles using only two or three monochromatic measurements. Spectral transmittance data, measured with a spectrophotometer and collected during a 46-week experimental soiling study carried out in Jaén, Spain, was analysed in this work. The use of a spectral profile for the hemispherical transmittance of soiled PV glass is found to significantly improve the soiling detection, returning the lowest errors independently of the PV materials and irradiance conditions. In addition, this work shows that it is also possible to select the measurement wavelengths to minimize the soiling loss detection error depending on the monitored PV semiconductor material (silicon, CdTe, a-Si, CIGS and a representative perovskite). The approaches discussed in this work are also found to be more robust to potential measurement errors compared to single wavelength measurement techniques.

14 SOLAR ENERGY↗

High-Performance Computing Based EMT Simulation of Large PV or Hybrid PV Plants

Faults in the transmission grid have led to reduced power generation from power electronics resources that are typically not connected to the faulted transmission line. In many of the cases, partial loss of power is observed within the power electronics resources like large photovoltaic (PV) power plants. This phenomena is not captured in existing simulation models and/or simulators. High-fidelity switched system electromagnetic transient (EMT) dynamic models of PV power plants can improve the fidelity of models available for accurate analysis of the impact on PV plants during simulation of faults. However, these models are extremely computationally expensive and take a long time to simulate. Long simulation times limit the ability to use these models as larger regions are studied in EMT simulations with more power electronics resources. In this paper, numerical simulation algorithms are combined with high-performance computing techniques and applied to the high-fidelity switched system EMT model of PV plants. Using these techniques, a speed-up of up to 58x is obtained, while preserving the accuracy of the simulation at greater than 98%.

Debnath, Suman↗

Evaluating Cell Temperature Models and the Effect of Wind Speed in PV System Capacity Testing: Preprint

Capacity testing is a routine procedure for assessing a photovoltaic system's performance relative to expectations. The most common test method involves fitting a regression model that predicts system output power using operating weather conditions including wind speed. Structural modifications to the regression model to incorporate wind in different ways improved the model's ability to fit measured system performance, but the observed improvements were small and unlikely to change the result of a capacity test. However, the results showed that the choice of reporting wind speed and inclusion or exclusion of wind speed in the performance model used as the test benchmark can significantly change the test result.

41 EE - Solar Energy Technologies Office (EE-4S)↗

PV Reference Cells for Outdoor Use: Stability Over Four Years of Deployment

Photovoltaic (PV) reference cells are frequently used to evaluate the performance of PV power plants. They provide a measure of irradiance that strongly correlates with the electrical output of PV modules, which makes them very useful for detecting short-term anomalies or long-term degradation in PV power plant output. One very important quality is long-term stability. This report presents observations about the stability of a set of 22 commercial reference cells that have been in continuous operation for a period of four years at the Solar Radiation Research Laboratory (SRRL) site at the National Renewable Energy Laboratory (NREL). The 22 reference cells at the SRRL represent 10 different models from 6 manufacturers.

14 SOLAR ENERGY↗

Arbitrage and Capacity Firming in Coordination with Day-Ahead Bidding of a Hybrid PV Plant

A hybrid PV plant (HPP) combines a photovoltaic (PV) plant with a battery energy storage system (BESS), which is considered a promising step towards the future of renewable power plants by the U.S. Department of Energy. When the renewable penetration reaches a significant level, a hybrid PV plant can bid in as a controllable thermal plant in the future electricity market. In this study, a bidding and BESS scheduling model is proposed for the HPP. The robust optimization (RO) technique has been utilized to identify the worst-case scenario of uncertainties during the bidding process. To address the overly conservative issue of the single-stage RO, we have decoupled the BESS schedule for arbitrage and PV capacity firming by a two-stage RO formulation. By comparing the output of single-stage RO and two-stage RO, the two-stage RO bids and schedules in a more aggressive manner, which increases the income of HPP. Also, the penalty of under-generation is considered in our model so that the day-ahead bidding decision and arbitrage schedules can be adjusted based on the potential UNDER-GENERATION penalty. Because the proposed model is non-convex and contains multi-stages, the Column-and-Constraint Generation (C&CG) algorithm is applied to the model as the solution. The proposed model has shown better economic performance compared to a state-of-art single-stage bidding method in case studies.

BESS scheduling↗

Measuring and Modeling Bifacial Technologies

Measuring and modeling bifacial technologies is of interest for new system design, capacity testing, and performance evaluation. The bifacial PV field at NREL has been gathering data for different bifacial technologies and sensors for the last 2.5 years, making it possible to compare bifacial performance with monofacial counterparts, as well as experimental demonstrations of best locations to place sensors to match modeled and perceived irradiance non-uniformity on the rear of the bifacial modules. This presentation summarizes performance, degradation, sensor position for module edge effects and the impact of row edge effects, and the roadmap for NREL bifacial modeling tools.

bifacial PV↗

Data-Driven Model for Photovoltaic Generation: Comparison with Physical Models Using a Microgrid in Puerto Rico

Photovoltaic (PV) generation is a critical component of microgrids, but its accurate modeling is challenging due to the complex and dynamic interactions between solar irradiance, temperature, and PV system installation. This paper develops a multilayer perceptron (MLP) model that inputs solar irradiance and temperature to estimate the PV generation, and it compares the proposed data-driven model’s performance to two well-known physical models: the single-diode model and the inverter model. The results demonstrate that all the models can reach high levels of accuracy. However, the MLP model outperforms the physical models on average by 4.5 to 6.6 percent in R squared scores and 220 to 290 Watts in RMSE scores, and it does not require physical system parameters. Moreover, the data-driven model can overcome the limitations of the lack of real-time PV generation data.

R pesante colón, Marcos↗

Advancing Agrivoltaic Modeling With ADAM

Designing an agrivoltaic system presents a complex set of tradeoffs around PV system configuration, resulting performance, agricultural needs, and system economics. Developing tools for agrivoltaic analysis can assist system designers when making decisions related to these tradeoffs. We are developing the Agrivoltaics Design and Analysis Model (ADAM) as a free, publicly available web tool for agrivoltaics economics analysis. Features of ADAM include automated calculations for available agrivoltaic cropland, user-friendly configuration changes, inter-row irradiance calculations, and integrated economic modeling of energy and non-energy revenues. We will discuss the iterative process of agrivoltaic tool development including tradeoffs between accuracy and uncertainty, feature prioritization, and ease of use driven by our multi-disciplinary stakeholder design process. Finally, we will share modeling results from existing agrivoltaics systems as a preliminary case study.

14 SOLAR ENERGY↗

Reliability and performance experience with flat-plate photovoltaic modules

Statistical models developed to define the most likely sources of photovoltaic (PV) array failures and the optimum method of allowing for the defects in order to achieve a 20 yr lifetime with acceptable performance degradation are summarized. Significant parameters were the cost of energy, annual power output, initial cost, replacement cost, rate of module replacement, the discount rate, and the plant lifetime. Acceptable degradation allocations were calculated to be 0.0001 cell failures/yr, 0.005 module failures/yr, 0.05 power loss/yr, a 0.01 rate of power loss/yr, and a 25 yr module wear-out length. Circuit redundancy techniques were determined to offset cell failures using fault tolerant designs such as series/parallel and bypass diode arrangements. Screening processes have been devised to eliminate cells that will crack in operation, and multiple electrical contacts at each cell compensate for the cells which escape the screening test and then crack when installed. The 20 yr array lifetime is expected to be achieved in the near-term.

Ross, R. G., Jr.↗

Viscoelastic Material Characterization and Modeling of Photovoltaic Module Packaging Materials for Direct Finite-Element Method Input

Numerical tools, such as the finite-element method, are increasingly used to design and evaluate the photovoltaic (PV) modules, providing for the reduction of development time and improved performance and reliability. However, high-fidelity material models are necessary to accurately model the complex structural behavior of the involved packaging materials. A common simplification used in recent years is to model the polymer materials (i.e., encapsulant and backsheet) as linear elastic, which will lead to inaccurate results. Therefore, in this work, we present a thorough characterization of the time- and temperature-dependent mechanical response of predominant PV module encapsulant and backsheet materials. Based on this material characterization, we developed and experimentally validated generalized Maxwell models to describe each material's viscoelastic response. In addition, we included measurements of the coefficient of thermal expansion and presented all material models in such a fashion for direct input into commercial finite-element method modeling software.

FEM↗

LID and LeTID Impacts to PV Module Performance and System Economics: Draft Analysis

This webinar is a technical review of the measurements and causes of BO LID, UV LID and LeTID, as well as modeling their impacts to PV project financial metrics. We will first review how Boron-Oxygen complexes form and detail the range of impacts to PV module power ratings over time and across climates. Similarly, we will also discuss the measurements and extent of UV LID over time and across climates. Then, we will demonstrate a methodology for translating these effects to pro forma cash flow models and their impacts to PV project financial returns and levelized cost of electricity (LCOE). We will conclude with estimates of the value of solutions to these degradation mechanisms.

41 EE - Solar Energy Technologies Office (EE-4S)↗