Search NASA⌕ Search

SEARCH · Search NASA

Results for “Particulate Contamination”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Report of tritide study at the Responsive Neutron Generator Product Deployment Center.

This report documents a study of sample counting results for wipes from routine surface area monitoring conducted at the Responsive Neutron Generator Product Deployment Center (RNGPDC) at Sandia National Laboratories (SNL). The study was initiated in November 2006, with two samples suspected of containing erbium tritide, after some samples were found to exhibit higher tritium counting rates upon recount at a later time. The main goal of the study was to determine whether the current practice of analyzing tritium wipe samples once, within a few days of sample collection, is adequate to accurately quantify the amount of tritium on the sample when tritides may be present. Recommendations are made toward routine recounting of vials suspected of containing particulate forms of tritium.

61 RADIATION PROTECTION AND DOSIMETRY↗

DEVELOPMENT OF A TAMPER RESISTANT/INDICATING AEROSOL COLLECTION SYSTEM FOR ENVIRONMENTAL SAMPLING AT BULK HANDLING FACILITIES

Environmental sampling has become a key component of International Atomic Energy Agency (IAEA) safeguards approaches since its approval for use in 1996. Environmental sampling supports the IAEA's mission of drawing conclusions concerning the absence of undeclared nuclear material or nuclear activities in a Nation State. Swipe sampling is the most commonly used method for the collection of environmental samples from bulk handling facilities. However, augmenting swipe samples with an air monitoring system, which could continuously draw samples from the environment of bulk handling facilities, could improve the possibility of the detection of undeclared activities. Continuous sampling offers the opportunity to collect airborne materials before they settle onto surfaces which can be decontaminated, taken into existing duct work, filtered by plant ventilation, or escape via alternate pathways (i.e. drains, doors). Researchers at the Savannah River National Laboratory and Oak Ridge National Laboratory have been working to further develop an aerosol collection technology that could be installed at IAEA safeguarded bulk handling facilities. The addition of this technology may reduce the number of IAEA inspector visits required to effectively collect samples. The principal sample collection device is a patented Aerosol Contaminant Extractor (ACE) which utilizes electrostatic precipitation principles to deposit particulates onto selected substrates. Recent work has focused on comparing traditional swipe sampling to samples collected via an ACE system, and incorporating tamper resistant and tamper indicating (TRI) technologies into the ACE system. Development of a TRI-ACE system would allow collection of samples at uranium/plutonium bulk handling facilities in a manner that ensures sample integrity and could be an important addition to the international nuclear safeguards inspector's toolkit. This work was supported by the Next Generation Safeguards Initiative (NGSI), Office of Nonproliferation and International Security (NIS), National Nuclear Security Administration (NNSA).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Evaluating Age Effects on HEPA Filter Performance

Nuclear grade high efficiency particulate air (HEPA) filters are routinely employed as the final control element in confinement ventilation systems. The traditional HEPA filter utilizes a pleated filter medium of fibrous glass that has been produced in a manner analogous to manufacturing paper. These filters are the physically weakest element in a containment ventilation system. Containment ventilation systems are designed to condition the air-stream (temperature, relative humidity, moisture, particle size distribution of aerosols, and aerosol concentration) to levels/conditions that fibrous glass HEPA filters can handle. Approximately 6000 nuclear grade HEPA filters are purchased each year for use in the DOE/NNSA complex. Additional filters are purchased for use in commercial nuclear power generation and ventilation systems of other nuclear applications. These filters are designed and tested in accordance with the American Society of Mechanical Engineers (ASME) AG-1 Code Nuclear Air and Gas Treatment. This code establishes design requirements and qualification procedures. Qualification testing of axial flow filters is described in paragraphs 5000 and following of AG-1. The series of qualification tests are intended to describe the operating envelope of HEPA filters and verify the reliability of a filter design. AG-1 qualification also confirms the pedigree of components used in manufacture for that filter design. The collective set of qualification tests establishes the assumed operating envelope for AG-1 filters. The effects of age on HEPA filter performance have been a concern for at least two decades. A combination of physical evaluation of aged filter media and a review of filter failure records resulted in Appendix C of the Nuclear Air Cleaning Handbook (NACH), Determination of HEPA Filter Life. This states that HEPA filters are not to be used beyond 10 years from the date of manufacture. Additionally, filters put into service in locations where they may become wet are to be taken out of service five years from date of manufacture. Filters that have become wet are to be taken out of service immediately. Finally, it should also be pointed out that filters held in Level B storage are subject to the same 10-year service life. Very limited bench-scale testing in the 1990's raised concern that aging HEPA filters do not have the strength to withstand an accident scenario. In May of 1999, the DNFSB released a Technical Report 23 entitled HEPA Filters Used in the Department of Energy's Hazardous Facilities. This report expressed concerns for the potential vulnerability of HEPA filters in vital safety systems. Concerns and uncertainty associated with degradation of HEPA filter performance over time led the DOE sites to limit HEPA filter service life to 10 years from the date of manufacture or five years in cases where filters may become wet. Establishment of a conservative service life needs to be based on data from a structured series of tests comparing the performance envelope of new and aged full-scale filters. A service life that is insufficiently conservative endangers workers and the public. One that is excessively conservative costs can cause hundreds of otherwise unnecessary filter changes. This increases exposure of employees, disrupts facility operations, and increase disposal costs by millions of dollars annually. Conclusive data are needed to resolve uncertainty associated with the damaging effects of aging on durability of HEPA filters. Therefore, this study needs to provide a sufficient body of evidence to allow DOE and site professionals to make prudent decisions. An updated version of ASME AG-1 Section FC included a non-mandatory appendix that would include the DOE guidance for service life of HEPA filters. Balloting of this revision generated significant resistance to inclusion of any kind of service life language citing the lack of supporting experimental data. Efforts to resolve negative votes failed and resistance to acceptance of the language increased. The result has been to not include service language in Section FC and requests to remove it from sections that already include such language. The recent activity of the ASME AG-1 Committee on Nuclear Air and Gas Treatment effectively de-emphasizes following DoE's service life guidelines. The DOE Office of Nuclear Safety under its NSR and D program provided the Mississippi State University Institute for Clean Energy Technology (ICET) finding to initiate a study to determine the effects of aging on AG-1 axial flow filters just prior to actions taken within the AG-1 committee regarding service life. The NSR and D funding facilitated timely development of a national technical working group comprised of members from the regulatory community, DOE complex, and commercial power to resolve uncertainty associated with effects of aging. The Department of Energy Office of Environmental Management (DOE-EM) has been funding the ICET to evaluate the performance envelope for AG-1 HEPA filters. ICET is one of DOE-EM's qualified suppliers. Synergy has been achieved by associating the NSR and D aged filter activities to testing activities evaluating the performance envelopes of separator and separator-less AG-1 HEPA filters funded by DOE-EM. The DOE-EM funded activities establish baseline data for the aged filter study and future EM funding will provide long term support for testing additional aged filters. EM funding of new filters includes analytical evaluation of media tensile strength by thermal analysis to establish baseline values and determine mass loss of moisture resistance and acrylic binders due to use. All of these values can be used for comparison of test results for aged filters. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Surface Cleaning Techniques: Ultra-Trace ICP-MS Sample Preparation and Assay of HDPE

The world’s most sensitive radiation detection and assay systems depend upon ultra-low background (ULB) materials to reduce unwanted radiological backgrounds. Herein, we evaluate methods to clean HDPE, a material of interest to ULB systems and the means to provide rapid assay of surface and bulk contamination. ULB level material and ultra-trace level detection of actinide elements is difficult to attain, due to the introduction of contamination from sample preparation equipment such as pipette tips, sample vials, forceps, etc. and airborne particulate. To date, literature available on the cleaning of such polymeric materials and equipment for ULB applications and ultra-trace analyses is limited. For these reasons, a study has been performed to identify an effective way to remove surface contamination from polymers in an effort to provide improved instrumental detection limits. Inductively Coupled Plasma Mass Spectroscopy (ICP-MS) was utilized to assess the effectiveness of a variety of leachate solutions for removal of inorganic uranium and thorium surface contamination from polymers, specifically high density polyethylene (HDPE). HDPE leaching procedures were tested to optimize contaminant removal of thorium and uranium. Calibration curves for thorium and uranium ranged from 15 ppq (fg/mL) to 1 ppt (pg/mL). Detection limits were calculated at 6 ppq for uranium and 7 ppq for thorium. Results showed the most effective leaching reagent to be clean 6 M nitric acid for 72 hour exposures. Contamination levels for uranium and thorium found in the leachate solutions were significant for ultralow level radiation detection applications.

HDPE, Leaching, Ultra-trace, ICP-MS, Uranium, Thor↗

Project 57 Air Monitoring Report: October 1, 2013, through December 31, 2014

On April 24, 1957, the Atomic Energy Commission (AEC, now the Department of Energy [DOE]) conducted the Project 57 safety experiment in western Emigrant Valley north east of the Nevada National Security Site (NNSS, formerly the Nevada Test Site) on lands withdrawn by the Department of Defense (DoD) for the Nevada Test and Training Range (NTTR). The test was undertaken to develop (1) a means of estimating plutonium distribution resulting from a nonnuclear detonation; (2) biomedical evaluation techniques for use in plutonium-laden environments; (3) methods of surface decontamination; and (4) instruments and field procedures for prompt estimation of alpha contamination (Shreve, 1958). Although the test did not result in the fission of nuclear materials, it did disseminate plutonium across the land surface. Following the experiment, the AEC fenced the contaminated area and returned control of the surrounding land to the DoD. Various radiological surveys have been performed in the area and in 2007, the DOE expanded the demarked contamination area by posting signs 200 to 400 feet (60 to 120 meters) outside of the original fence. Plutonium in soil is thought to attach preferentially to smaller particles. Therefore, redistribution of soil particulates by wind (dust) is the mechanism most likely to transport plutonium beyond the boundary of the Project 57 contamination area. In 2011, DRI installed two instrumentation towers to measure radiological, meteorological, and dust conditions. The monitoring activity was implemented to determine if radionuclide contamination was detectable in samples of airborne dust and characterize meteorological and environmental parameters that influence dust transport. Collected data also permits comparison of radiological conditions at the Project 57 monitoring stations to conditions observed at Community Environmental Monitoring Program (CEMP) stations around the NTTR. Biweekly samples of airborne particulates are submitted for laboratory assessment of gross alpha and gross beta radioactivity and for determination of gamma-emitting radionuclides. Annual average gross alpha values at the Project 57 monitoring stations are in the same range as the highest two values reported for the CEMP stations surrounding the NTTR. Annual average gross beta values at the Project 57 monitoring stations are slightly higher than the lowest value reported for the CEMP stations surrounding the NTTR. Gamma spectroscopy analyses on samples collected from the Project 57 stations identified only naturally occurring radionuclides. No manmade radionuclides were detected. Thermoluminescent dosimeters (TLDs) indicated that the average annual radioactivity dose at the monitoring stations is higher than the dose determined at surrounding CEMP stations but approximately half of the estimated national average dose received by the general public as a result of exposure to natural sources. The TLDs at the Project 57 monitoring stations are exposed to both natural sources (terrestrial and cosmic) and radioactive releases from the Project 57 contamination area. These comparisons show that the gross alpha, gross beta, and gamma spectroscopy levels at the Project 57 monitoring stations are similar to levels observed at the CEMP stations but that the average annual dose rate is higher than at the CEMP stations. Winds in excess of approximately 15 mph begin to generate dust movement by saltation (migration of sand at the ground surface) or direct suspension in the air. Saltated sand, PM10 (inhalable) dust, and PM2.5 (fine particulate dust) exhibit an approximately exponential increase with increasing wind speed. The greatest concentrations of dust occur for winds exceeding 20 mph. During the reporting period, winds in excess of 20 mph occurred approximately 1.6 percent of the time. Preliminary assessment of individual wind events suggests that dust generation is highly variable likely because of the influence of other meteorological and environmental parameters. Although winds sufficient to generate significant amounts of dust occur at the Project 57 site, they are infrequent and of short duration. Additionally, the potential for wind transport of dust is dependent on other parameters whose influence have not yet been assessed.

54 ENVIRONMENTAL SCIENCES↗

Development and Characterization of Cementitious Waste Forms for Immobilization of Granular Activated Carbon, Silver Mordenite, and HEPA Filter Media Solid Secondary Waste

Solid secondary waste materials expected to be generated during Hanford Waste Treatment and Immobilization Plant (WTP) operations were characterized (using representative materials) with respect to their ability to retain technetium-99 (Tc), iodine-129 (I), and mercury (Hg) as input to future updates to the Integrated Disposal Facility (IDF) performance assessments (PAs). The waste materials included granular activated carbon (GAC), silver mordenite (AgM), and high-efficiency particulate air (HEPA) filter media; all are used for removal of contaminants and radionuclides from the gaseous effluent treatment systems within the WTP. It is expected that the GAC and AgM will be mixed into a cementitious waste form in which the GAC and AgM particles will be blended/stabilized into the cementitious material. It is also expected that the HEPA filter media will be compacted and placed in a container that is then backfilled with a grout to macroencapsulate the medium. Here we report Kds for all waste materials of interest, examine the physical properties of grout specimens containing the waste materials, and provide solid-state characterization information to further understand the interaction of the waste materials with the encapsulating grout. The Kds are used in PA calculations that estimate contaminant release from the disposal site. Monolithic test specimens were prepared with the GAC and AgM mixed in either a Cast Stone grout formulation (8 weight percent [wt%] ordinary Portland cement [OPC], 45 wt% fly ash [FA], 47 wt% blast furnace slag [BFS]) or a Hanford grout mix 5 (HGM-5) formulation (25 wt% OPC, 75 wt% FA). As the specimens were being prepared, the fluid grout mixes were characterized for processing properties including flowability, set time, and the presence of free liquids during curing. After curing, compressive strengths of the waste forms were measured; the compressive strengths were above 2000 psi, easily exceeding the 500 psi minimum requirement. The cured waste forms were also characterized for their density, porosity, hydraulic conductivity, and water characteristic curve—all properties needed in PA calculations of radionuclide release from the waste forms in the IDF. Finally, EPA Method 1315 leach tests were conducted on the GAC and AgM waste materials encapsulated in the Cast Stone and HGM-5 grouts to determine the rate of release of contaminants from the waste forms. Effective diffusivities are provided, which can be used in future PA analyses of the disposal of these solid secondary waste materials.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of a Radioactive Release in a Nuclear Waste Disposal Facility

The Waste Isolation Pilot Plant (WIPP) is a 655-meter deep mine near Carlsbad, New Mexico, used to dispose the nation’s defense transuranic waste. Limited airborne radioactivity was released from a container of radioactive waste in WIPP on 14 February, 2014. As designed, a mine ventilation filtration system prevented the large scale release of contamination from the underground. However, isolation dampers leaked, which allowed the release of low levels of contaminants after the event until they were sealed. None of the exposed individuals received any recordable dose. While surface contamination was limited, contamination in the ventilation system and portions of the underground was substantial. High efficiency particulate air (HEPA) filters in the operating ventilation system ensure continued containment during recovery and resumption of disposal operations. However, ventilation flow is restricted since the incident, with all exhaust air directed through the filters. Decontamination and natural fixation by the hygroscopic nature of the salt host rock has reduced the likelihood of further contamination spread. Contamination control and ventilation system operability are crucial for resumption of operations. This article provides an operational assessment and evaluation of these two key areas.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

ULTRA SECURE HIGH RELIABILITY WIRELESS RADIATION MONITOR

Radiation monitoring in nuclear facilities is essential to safe operation of the equipment as well as protecting personnel. In specific, typical air monitoring of radioactive gases or particulate involves complex systems of valves, pumps, piping and electronics. The challenge is to measure a representative sample in areas that are radioactively contaminated. Running cables and piping to these locations is very expensive due to the containment requirements. Penetration into and out of an airborne or containment area is complex and costly. The process rooms are built with thick rebar-enforced concrete walls with glove box containment chambers inside. Figure 1 shows high temperature radiation resistance cabling entering the top of a typical glove box. In some case, the entire processing area must be contained in a 'hot cell' where the only access into the chamber is via manipulators. An example is shown in Figure 2. A short range wireless network provides an ideal communication link for transmitting the data from the radiation sensor to a 'clean area', or area absent of any radiation fields or radioactive contamination. Radiation monitoring systems that protect personnel and equipment must meet stringent codes and standards due to the consequences of failure. At first glance a wired system would seem more desirable. Concerns with wireless communication include latency, jamming, spoofing, man in the middle attacks, and hacking. The Department of Energy's Savannah River National Laboratory (SRNL) has developed a prototype wireless radiation air monitoring system that address many of the concerns with wireless and allows quick deployment in radiation and contamination areas. It is stand alone and only requires a standard 120 VAC, 60 Hz power source. It is designed to be mounted or portable. The wireless link uses a National Security Agency (NSA) Suite B compliant wireless network from Fortress Technologies that is considered robust enough to be used for classified data transmission in place of NSA Type 1 devices.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Trace Uranium Partitioning in a Multiphase Nano-FeOOH System

The characterization of trace elements in nanomaterials using extended X-ray absorption fine structure (EXAFS) spectroscopy constitutes a first step toward understanding how impurities or dopants affect the properties of the host phase. However, limitations to EXAFS interpretation complicate the analysis of trace concentrations of impurities that are distributed across multiple phases in a heterogeneous system. Ab initio molecular dynamics (AIMD)-informed EXAFS analysis was employed to investigate the immobilization of trace uranium associated with nanophase iron (oxyhydr)oxides, a model system for the geochemical sequestration of radiotoxic contaminants. The reductive transformation of ferrihydrite (Fe(OH)3) to nano-particulate iron oxyhydroxide minerals in the presence of uranyl (UO2)2+(aq) resulted in the preferential incorporation of U into goethite (a-FeOOH) over lepidocrocite (g-FeOOH), even though reaction conditions favored the formation of excess lepidocrocite. This unexpected result is supported by atomically resolved transmission electron microscopy. Using this model system, we demonstrate how AIMD-informed EXAFS analysis lifts the strict statistical limitations of traditional shell-by-shell EXAFS modeling, enabling the detailed analysis of the local bonding environment, charge compensation mechanisms, and oxidation states of polyvalent impurities in complex multi-phase nano-systems.

ab initio molecular dynamics↗

"Soiling, Cleaning, and Abrasion: The Results of the Five-Year Photovoltaic Glass Coating Field Study" [Slides]

External contamination ("soiling") of the incident surface is a major limiting factor for solar technologies. A 5-year field glass coupon study was conducted to better understand external contamination and its effects; compare cleaning methods and the use of preventative coatings; and explore the abrasion resulting from cleaning to advise on accelerated abrasion testing. Test sites included the cities of Dubai (UAE), Kuwait City (Kuwait), Mesa (AZ), Mumbai (India), and Sacramento (CA). Through the 5-year cumulative study, dry brush, water spray, and wet sponge and squeegee cleaning methods were compared to no cleaning. Optical microscopy was used to obtain images, including representative color images, grayscale images for object analysis, and oblique images for coating integrity assessment. A thresholding protocol was developed to analyze and distinguish specimens using the ImageJ software. Optical performance was quantified using a spectrophotometer, including comprehensive optical characterization (transmittance, reflectance, and absorptance in addition to forward- and back-scattering). Atomic force microscopy was used to verify the abrasion damage morphology, including the width and depth of surface scratches. Analysis of the results included correlation of optical performance and particle area coverage, rank order (by coating or location), and the acceleration factor for abrasion damage. The efficacy of external cleaning was more readily distinguished from the effectiveness of antisoiling coatings. The acceleration factor for dry brush cleaning of a porous silica coating was found to be on the order of unity.

14 SOLAR ENERGY↗

Performance Evaluation of AG-1 FC HEPA Filters and Medium in Nuclear Complex Facilities - 20434

High Efficiency Particulate Air (HEPA) filters are credited as the final barrier against the release of radioactive aerosol contamination in nearly every operating U. S. Department of Energy (DOE) and National Nuclear Security Agency (NNSA) nuclear facility. The Institute for Clean Energy Technology (ICET) at Mississippi State University maintains a research program that studies various aspects of these components of containment systems and seeks to answer key questions from across the industry. This programmatic overview will include results from recent and ongoing studies, including a study on filter design and performance envelope, degradation due to aging or fatigue, fire event impact on HEPA filters, and accelerated aging of medium and component parts. ICET has completed a study helping to define the threshold for combined elevated temperature and relative humidity resistance of separator style and separator-less style HEPA filters that are used in DOE complexes. The study provides experimental data that considers elevated temperature, elevated relative humidity (RH), and target differential pressure (dP) in an attempt to gain a better understanding or more comprehensive insight into the operating envelope of different configurations of ASME (American Society for Mechanical Engineers) AG-1 Section FC filters. Test variables including air temperature ranges of 48.88 deg. C, 54.44 deg. C, or 60 deg. C (120, 130, or 140 deg. F); air RH ranges including 60-70%, 80%, or 90+% with initial filter dP of either 497.68 Pa, 746.52 Pa, or 995.36 Pa (2 inches water column (in. w. c.), 3 in. w. c., or 4 in. w. c.) included for full bracketing of each set of conditions. A study examining the effects of aging and fatigue on nuclear grade HEPA filters and medium elucidates the physical properties of media along with testing of new and aged ASME AG-1 HEPA filters. In addition to performing autopsies of the tested, aged filters to help better understand the service life of their performance, newly designed accelerated aging chambers allow new medium to undergo accelerated aging and exposure treatments. Evaluation of degradation in physical properties and functionality requires a high population of aged filters of different ages, designs, manufacturers, and operational histories. The limited availability of this population and the impropriety of looking solely at formulations and components from past years requires experimental design that will provide foresight into future filter performance. This undertaking therefore involves not only properties analysis of aged medium from different operational histories, ages, designs, and manufacturers, but also prescience in analytical goals via accelerated aging studies of newly manufactured media. A more complete understanding of the mechanisms of degradation from past formulations as well as current and future formulations is possible. Accelerated Aging of newly manufactured media utilizes exposure treatments based on the Arrhenius equation to artificially age medium and therefore glimpse into the future. Evaluation of current media properties This testing allows for the comparison of performance and durability of new filters under upset or design basis conditions with aged filters that were in service under ambient conditions and other aged filters retained in storage. Susceptibility of HEPA filters to the effects of combustion byproducts, heat, and water is also being studied in an attempt to gain understanding on the prevention of filter failures during fire events in nuclear facilities. ICET seeks to determine the effect of filter performance due to smoke loading using characterized smoke from variable fuel compositions, geometries, and loads; the smoke capacity of various filters with different burning conditions, heat release rates and transport, as well as mass transport from the air stream will be studied in low flow containment systems. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Diel mercury concentration variations in a mercury-impacted stream

Here, filtered and particulate mercury (Hg) and methylmercury (MMHg), and associated water chemistry parameters, were evaluated bi-hourly for several 30 h periods during the summer and winter seasons at several distinct locations (downstream forested, midstream urban/suburban, upstream industrial) along a creek contaminated with high levels of inorganic Hg to determine if biogeochemical Hg and MMHg cycles respond to the daily photocycle. In summer particulate Hg and MMHg concentrations doubled overnight (excluding the upstream industrial site) concurrent with increases in turbidity and total suspended sediment; no such pattern was evident in winter. Seasonal and diel changes in the activity of macrobiota affecting the suspension of contaminated sediments are likely responsible for these patterns as other potential explanatory variables (e.g., instrument drift, pH, discharge) could not account for the range and timing of our observations. Diel patterns in filtered Hg (Hg D ) were significant only at locations and times of the year when channel shading was not present and daytime concentrations increased 22–89% above nighttime minima likely caused by direct and indirect photochemical reactions. Relationships between Hg D and dissolved organic carbon (DOC) concentration or character were inconsistent between sites. Unlike Hg D , there were significant diel patterns in filtered MMHg (MMHg D ) at all sites and times of year, with summer concentrations peaking in mid to late afternoon while the timing differed in winter, with concentrations peaking after sunset. Daily variability in MMHg D concentration ranged between 25 and 75%. The results imply key controls on net methylation occur within the stream or on the stream bed and include factors such as small-scale temperature changes in the water column and photosynthetic activity of stream biofilm. With respect to stream monitoring, results from this study indicate (1) consistent timing in stream Hg and MMHg sampling is required for accurate assessment of long-term trends, (2) in situ measurements of turbidity can be used to quantify diel dynamics of both particulate Hg and MMHg concentrations, and (3) in situ fluorescing dissolved organic matter (FDOM), a potential proxy for DOC, was not capable of resolving diel dynamics of filtered Hg or MMHg.

54 ENVIRONMENTAL SCIENCES↗

Intraday Water Quality Patterns in East Fork Poplar Creek with an Emphasis on Mercury and Monomethylmercury

We conducted a diel sampling campaign at three locations along the Hg contaminated East Fork Poplar Creek (EFPC) in Oak Ridge, Tennessee to (i) quantify diel patterns of particulate and dissolved mercury (Hg) and monomethylmercury (MMHg) (Hg D , Hg P , MMHg D , and MMHg P , respectively) and associated water quality parameters along a longitudinal gradient of EFPC during the summer season, (ii) determine if diel patterns in Hg and/or MMHg are related to the daily photocycle or any other short term cycle, such as wastewater treatment plant discharge, (iii) determine if diel variability in turbidity and dissolved organic matter (DOM) composition correspond to particulate Hg P or MMHg P and dissolved organic carbon (DOC) or dissolved Hg D or MMHg D . Samples were collected every two hours for a 30 hour period. The farthest upstream site was located at the boundary of Y-12 and the City of Oak Ridge (EFK 23.4) while two additional sites were located 7.2 kilometers (Wiltshire Drive, EFK 16.2) and 18 kilometers (Horizon Center, EFK 5.4) downstream of EFK 23.4). Hg P and MMHg P concentrations increased overnight at EFK 16.2 and EFK 5.4 coincident with increases in turbidity and total suspended solids (TSS). These overnight increases were likely due to diel changes in the activity of macrobiota (re)suspending contaminated sediments in the creek. Both Hg D and MMHg D were higher during the day at EFK 23.4 and EFK 5.4. The underlying causes for the patterns in Hg D and MMHg D are less clear but correspond with similar patterns in DOC concentration and DOM composition. Photochemical reactions may also play a role in these Hg D , MMHg D , DOC, and DOM patterns. Total loads of both Hg and MMHg increased with downstream distance. The greatest increase in loading occurred in the reach from EFK 23.4 to EFK 16.2 which encompasses areas where the Historic Release Deposits (HRD) have been identified. These results demonstrate that diffuse legacy sources of Hg, outside of Y-12, contribute Hg load to EFPC. Both total and dissolved MMHg loads increased approximately linearly with downstream distance. Particluate MMHg loading increased in the upper reach but did not change over the lower reach. The HRD may contribute to MMHg P load in the upper reach but most of the total, dissolved, and particulate MMHg appears to originate from in-stream production. Due to intraday patterns in concentration and flow rate, loading estimates are best derived from diel sampling campaigns. Intraday patterns in Hg and MMHg concentration and speciation have implications with respect to biotic exposure. Greater biotic activity and feeding during times of higher concentration would correspond to greater exposure than estimated from daily or longer-term averages. Both Hg and MMHg responded rapidly to processes governing their concentration. This latter point is encouraging from the perspective of site remediation as it suggests that MMHg concentrations and flux in EFPC would respond rapidly to appropriate remedial actions.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Confocal (micro)-XRF for 3D anlaysis of elements distribution in hot environmental particles

Studies on the fate and transport of radioactive contaminates in the environment are often constrained by a lack of knowledge on the elemental distribution and general behavior of particulate bound radionuclides contained in hot particles. A number of hot particles were previously isolated from soil samples collected at former U.S. nuclear test sites in the Marshall Islands and characterized using non-destructive techniques [1]. The present investigation at HASYLAB is a part of larger research program at ITU regarding the characterization of environmental radioactive particles different locations and source-terms. Radioactive particles in the environment are formed under a number of different release scenarios and, as such, their physicochemical properties may provide a basis for identifying source-term specific contamination regimes. Consequently, studies on hot particles are not only important in terms of studying the elemental composition and geochemical behavior of hot particles but may also lead to advances in assessing the long-term impacts of radioactive contamination on the environment. Six particles isolated from soil samples collected at the Marshall Islands were studied. The element distribution in the particles was determined by confocal {micro}-XRF analysis using the ANKA FLUO beam line. The CRL (compound refractive lens) was used to focus the exciting beam and the polycapillary half lens to collimate the detector. The dimensions of confocal spot were measured by 'knife edge scanning' method with thin gold structure placed at Si wafer. The values of 3.1 x 1.4 x 18.4 {micro}m were achieved if defined as FWHMs of measured L?intensity profiles and when the19.1 keV exciting radiation was used. The collected XRF spectra were analyzed offline with AXIL [2] software to obtain net intensities of element characteristic lines.Further data processing and reconstruction of element distribution was done with the software 'R' [3] dedicated for statistical calculations. In figure 1 the distributions of Pu, Fe and Ti obtained for one of the studied hot particles are presented. The strongest signal was recorded for plutonium; the signals from iron and titanium are respectively 14 and 38 times less. It means that Pu is the most abundant of the observed elements. However, since the light elements are not detectable with the applied measurement conditions, it cannot be definitely stated if plutonium is the main element present in the sample. The isosurfaces are calculated at 20 % of maximum intensity for each element. Please note that the isosurfaces on the drawing are transparent. Changes in the spatial distribution of Pu, Fe, and Ti within the particle are shown in Fig. 2a, 2b, and 2c. Distinct elemental patterns are clearly visible at the higher concentration levels. The distributions of Cr, Cu, and Pb were also reconstructed but the results are not presented here. As it is shown in Fig. 1, the correlation between elements is good at low concentrations but the maxima of concentrations are not strongly correlated (see Fig. 2.). In general, the particle is inhomogeneous in terms of its elemental composition. Similar inhomogeneities were found for other particles with Pu identified as a major element in three of the six particles examined.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Investigation of the Effects of Biodiesel-based Na on Emissions Control Components

A single-cylinder diesel engine was used to investigate the impact of biodiesel-based Na on emissions control components using specially blended 20% biodiesel fuel (B20). The emissions control components investigated were a diesel oxidation catalyst (DOC), a Cu-zeolite-based NH{sub 3}-SCR (selective catalytic reduction) catalyst, and a diesel particulate filter (DPF). Both light-duty vehicle, DOC-SCR-DPF, and heavy-duty vehicle, DOC-DPF-SCR, emissions control configurations were employed. The accelerated Na aging is achieved by introducing elevated Na levels in the fuel, to represent full useful life exposure, and periodically increasing the exhaust temperature to replicate DPF regeneration. To assess the validity of the implemented accelerated Na aging protocol, engine-aged lean NO{sub x} traps (LNTs), DOCs and DPFs are also evaluated. To fully characterize the impact on the catalytic activity the LNT, DOC and SCR catalysts were evaluated using a bench flow reactor. The evaluation of the aged DOC samples and LNT show little to no deactivation as a result of Na contamination. However, the SCR in the light-duty configuration (DOC-SCR-DPF) was severely affected by Na contamination, especially when NO was the only fed NO{sub x} source. In the heavy-duty configuration (DOC-DPF-SCR), no impact is observed in the SCR NO{sub x} reduction activity. Electron probe micro-analysis (EPMA) reveals that Na contamination on the LNT, DOC, and SCR samples is present throughout the length of the catalysts with a higher concentration on the washcoat surface. In both the long-term engine-aged DPF and the accelerated Na-aged DPFs, there is significant Na ash present in the upstream channels; however, in the engine-aged sample lube oil-based ash is the predominant constituent.

33 ADVANCED PROPULSION SYSTEMS↗

The Challenges of Air Monitoring at a Soil Remediation Project in a Suburban Setting - 20448

Air monitoring during soil excavation at a chemically and radiologically impacted site in a suburban setting presents unique challenges. Site activities were conducted in a manner that minimized the release of airborne particulates of concern, principally radionuclides of concern (ROC). Dust and air monitoring were performed to ensure the public was not being exposed to the soil contaminants. The project team collected representative air and dust data while being mindful to not impose on the lives of residents in the area. Due to the close proximity to the public, there was a high level of oversight from the client and regulatory agencies. The challenges involved with air sampling at this soil remediation site located in a suburban setting included the number of contaminants, the ranges of risks and hazards presented by the contaminants and the method of remediation, the concerns of the regulators and the public, and the perception of risk from the public. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Healthy Zero Energy Buildings (HZEB) Program - Cross-Sectional Study of Contaminant Levels, Source, Strengths, and Ventilation Rates in Retail Stores

This field study measured ventilation rates and indoor air quality parameters in 21 visits to retail stores in California. The data was collected to guide the development of new, science-based commercial building ventilation rate standards that balance the dual objectives of increasing energy efficiency and maintaining acceptable indoor air quality. Data collection occurred between September 2011 and March 2013. Three types of stores participated in this study: grocery stores, furniture/hardware stores, and apparel stores. Ventilation rates and indoor air contaminant concentrations were measured on a weekday, typically between 9 am and 6 pm. Ventilation rates measured using a tracer gas decay method exceeded the minimum requirement of California’s Title 24 Standard in all but one store. Even though there was adequate ventilation according to Title 24, concentrations of formaldehyde, acetaldehyde, and acrolein exceeded the most stringent chronic health guidelines. Other indoor air contaminants measured included carbon dioxide (CO{sub 2}), carbon monoxide (CO), ozone (O{sub 3}), and particulate matter (PM). Concentrations of CO{sub 2} were kept low by adequate ventilation, and were assumed low also because the sampling occurred on a weekday when retail stores were less busy. CO concentrations were also low. The indoor-outdoor ratios of O{sub 3} showed that the first-order loss rate may vary by store trade types and also by ventilation mode (mechanical versus natural). Analysis of fine and ultrafine PM measurements showed that a substantial portion of the particle mass in grocery stores with cooking-related emissions was in particles less than 0.3 μm. Stores without cooking as an indoor source had PM size distributions that were more similar indoors and outdoors. The whole-building emission rates of volatile organic compounds (VOCs) and PM were estimated from the measured ventilation rates and indoor and outdoor contaminant concentrations. Mass balance models were then used to determine the ventilation rates, filtration strategies, or source reductions needed to maintain indoor contaminant concentrations below reference levels. Several scenarios of potential concern were considered: (i) formaldehyde levels in furniture/hardware stores, (ii) contaminants associated with cooking (e.g., PM, acrolein, and acetaldehyde) in grocery stores, and (iii) outdoor contaminants (e.g., PM and O{sub 3}) impacting stores that use natural ventilation. Estimated formaldehyde emission rates suggest that retail stores would need to ventilate at levels far exceeding the current Title 24 requirement to lower indoor concentrations below California’s stringent formaldehyde reference level. Given the high costs of providing ventilation but only modest chronic health benefit is expected, effective source control is an attractive alternative, as demonstrated by some retail stores in this study. Predictions showed that grocery stores need MERV 13 air filters, instead of MERV 8 filters that are more commonly used, to maintain indoor PM at levels that meet the chronic health standards for PM. Exposure to acrolein is a potential health concern in grocery stores, and should be addressed by increasing the use of kitchen range hoods or improving their contaminant removal efficiency. In stores that rely on natural ventilation, indoor PM can be a health concern if the stores are located in areas with high outdoor PM. This concern may be addressed by switching to mechanical ventilation when the outdoor air quality is poor, while continuing natural ventilation when outdoor air quality is good.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗