Search NASA⌕ Search

SEARCH · Search NASA

Results for “Performance, Reliability, Design, Measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Techniques for measuring aerosol attenuation using the Central Laser Facility at the Pierre Auger Observatory

The Pierre Auger Observatory in Malargüe, Argentina, is designed to study the properties of ultra-high energy cosmic rays with energies above 10(18)eV. It is a hybrid facility that employs a Fluorescence Detector to perform nearly calorimetric measurements of Extensive Air Shower energies. To obtain reliable calorimetric information from the FD, the atmospheric conditions at the observatory need to be continuously monitored during data acquisition. In particular, light attenuation due to aerosols is an important atmospheric correction. The aerosol concentration is highly variable, so that the aerosol attenuation needs to be evaluated hourly. We use light from the Central Laser Facility, located near the center of the observatory site, having an optical signature comparable to that of the highest energy showers detected by the FD. This paper presents two procedures developed to retrieve the aerosol attenuation of fluorescence light from CLF laser shots. Cross checks between the two methods demonstrate that results from both analyses are compatible, and that the uncertainties are well understood. The measurements of the aerosol attenuation provided by the two procedures are currently used at the Pierre Auger Observatory to reconstruct air shower data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance and Reliability Assessment of the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) Data Advisor (ADA)

The Atmospheric Radiation Measurement (ARM) User Facility provides one of the world's largest openly accessible repositories of atmospheric observations through the ARM Data Discovery platform. Although the repository contains more than three decades of measurements collected from permanent observatories, mobile facilities, aircraft campaigns, and field experiments, identifying appropriate datasets can be challenging, particularly for new users unfamiliar with ARM instrumentation and datastream organization. To improve data accessibility, the ARM Data Center developed the ARM Data Advisor (ADA), an artificial intelligence-powered assistant designed to facilitate scientific data discovery, dataset interpretation, and user guidance. This report evaluates ADA's performance as a domain-specific scientific assistant using realistic atmospheric science workflows. The evaluation examines five key capabilities: data retrieval and curation efficiency, hallucination resistance, scientific reasoning, response to ambiguous queries, and content retention and session continuity. Representative prompts were developed to simulate typical interactions between researchers and the ARM Data Discovery platform, and ADA's responses were assessed for retrieval completeness, scientific accuracy, consistency, and practical usefulness. In these representative tests, ADA reduced the complexity of discovering and accessing ARM datasets by recommending appropriate datastreams, explaining instrumentation, interpreting metadata, and assisting with data processing workflows. ADA also exhibits strong domain knowledge of atmospheric science terminology and generally resists hallucination by acknowledging unavailable datasets and requesting clarification when appropriate. Overall, the results indicate that ADA represents a promising advancement in scientific data discovery within the ARM User Facility and has considerable potential to improve researcher productivity, particularly for new users and interdisciplinary scientists seeking efficient access to ARM observations.

Salvador, Christian [ORNL] (ORCID:0000000283287777↗

High Temperature Irradiation-Resistant Thermocouple Performance Improvements

Traditional methods for measuring temperature in-pile degrade at temperatures above 1100 ºC. To address this instrumentation need, the Idaho National Laboratory (INL) developed and evaluated the performance of a high temperature irradiation-resistant thermocouple (HTIR-TC) that contains alloys of molybdenum and niobium. Data from high temperature (up to 1500 ºC) long duration (up to 4000 hours) tests and on-going irradiations at INL’s Advanced Test Reactor demonstrate the superiority of these sensors to commercially-available thermocouples. However, several options have been identified that could further enhance their reliability, reduce their production costs, and allow their use in a wider range of operating conditions. This paper presents results from on-going Idaho National Laboratory (INL)/University of Idaho (UI) efforts to investigate options to improve HTIR-TC ductility, reliability, and resolution by investigating specially-formulated alloys of molybdenum and niobium and alternate diameter thermoelements (wires). In addition, on-going efforts to evaluate alternate fabrication approaches, such as drawn and loose assembly techniques will be discussed. Efforts to reduce HTIR-TC fabrication costs, such as the use of less expensive extension cable will also be presented. Finally, customized HTIR-TC designs developed for specific customer needs will be summarized to emphasize the varied conditions under which these sensors may be used.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NREL RSF Measured Data 2011

Modern buildings are complex energy systems that must be controlled for energy efficiency. The Research Support Facility (RSF) at the National Renewable Energy Laboratory (NREL) has hundreds of controllers -- computers that communicate with the building's various control systems -- to control the building based on tens of thousands of variables and sensor points. These control strategies were designed for the RSF's systems to efficiently support research activities. Many events that affect energy use cannot be reliably predicted, but certain decisions (such as control strategies) must be made ahead of time. NREL researchers modeled the RSF systems to predict how they might perform. They then monitor these systems to understand how they are actually performing and reacting to the dynamic conditions of weather, occupancy, and maintenance. This submission includes the Measured Energy Data from the RSF Systems Model. The data includes a csv with measured data from NREL's Research and Support Facility (RSF) for 2011. The dataset contains hourly data for: Total Cooling (kW)- Total Heating (kW)- Total Mechanical (kW)- Total Lighting (kW)- Total Plug Loads (kW)- Total Data Center (kW)- Total Building (kW)- PV (kW)- Building Net (kW). Energy Model data and Weather data related to the RSF Systems Model can be found in the "Related Datasets" section of this submission.

2011↗

A SUMMARY COMPARISON OF DESIGN EVALUATION TECHNIQUES

The United States’ fleet of Nuclear Reactors is considering modernizing their control rooms and instrumentation as an effort to avoid component obsolescence, keep up with competing industries, and cater to a new work force among others. Multiple technologies have potential to improve the control room. In attempts to evaluate the available options researchers employ a variety of measures to ensure the best candidate is used in a modernizing effort. The NRC is in charge of ensuring any new design has been thoroughly vetted before approving a license. Laid out in NUREG-0711 “Human Factors Engineering Program Review Model” is the review criteria for design validation. As there are a variety of measures currently used to evaluate candidate technologies, this paper seeks to identify weaknesses in the common measures used to design and validate technology in control room modernization efforts. Identifying where measurements are not meeting the criteria will help the control room modernization research platform identify where measurement development needs to occur. This will help ensure that current performance measurements are producing as reliable results as possible to select the right technology to integrate into nuclear operating control rooms.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

ATRIUM{sup TM} 11 operating experience

AREVA NP developed the ATRIUM{sup TM}11 BWR fuel assembly to address the industry need for substantial improvements in fuel reliability and economic performance. The product development effort initially consisted of analytical design assessments and out-of-pile testing of prototype fuel assemblies and components. An integral component of the development project is a comprehensive in-pile demonstration program designed to fully exercise the new fuel assembly under a variety of operating conditions and to provide performance measurements of new design features. Fuel vendors, reactor operators, and regulators have successfully relied upon irradiation feedback derived from in-pile demonstration programs to safely introduce new features in reload quantities. The primary ATRIUM{sup TM} 11 in-pile demonstration program consists of 40 lead fuel assemblies (LFA) operating among five BWR reactors globally, covering the range of operational regimes and licensing environments necessary to confirm reload applications for the product. Since the initial irradiation in 2012, multiple pool-side inspection examinations have been performed. The inspection activities primarily focused on the new design features; including the spacer, fuel rod array, upper tie plate and fuel channel. These inspections have resulted in the collection of a substantial set of visual images, dimensional measurements, and performance feedback that are of general interest to the industry. Results from the inspections are compared to the database for existing products and to predetermined acceptance criteria. This paper provides details of the global in-pile demonstration program and the characteristics of the LFAs. Results of the inspection campaigns will be presented, including a summary of the technical assessment of specific new design features and the overall performance of the ATRIUM{sup TM} 11 product. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Assessment of operational availability for the PIP-II Superconducting Radio Frequency linear accelerator facility

Operational availability is a critical performance measure for an accelerator facility in modern time. A high availability enables the facility to serve a wide range of users simultaneously. Consequently, besides pure accelerator physics considerations, newly proposed accelerator facilities account for the availability and reliability aspects in the design phases. It allows incorporation of appropriate mitigation strategies for the most vulnerable systems in the machine and therefore, minimizes unscheduled interruptions during the operation. This report lays out a methodology for the availability assessment of the complete particle accelerator facility and presents an initial assessment of the availability of the newly proposed Proton Improvement Plan-II (PIP-II) accelerator facility at Fermilab. The paper describes a comprehensive reliability model of the PIP-II facility that comprises not only 800 MeV linear accelerator (linac) system but also essential utility systems in the form of cryogenic, water, power and air systems. The paper details estimations of the availability of the PIP-II facility for two operational modes i.e. the nominal operational mode featuring 800 MeV beam and critical operational mode involving operation with the lowest objective beam energy of 600 MeV.

43 PARTICLE ACCELERATORS↗

A new event builder for CMS Run II

The data acquisition system (DAQ) of the CMS experiment at the CERN Large Hadron Collider (LHC) assembles events at a rate of 100 kHz, transporting event data at an aggregate throughput of 100 GB/s to the high-level trigger (HLT) farm. The DAQ system has been redesigned during the LHC shutdown in 2013/14. The new DAQ architecture is based on state-of-the-art network technologies for the event building. For the data concentration, 10/40 Gbps Ethernet technologies are used together with a reduced TCP/IP protocol implemented in FPGA for a reliable transport between custom electronics and commercial computing hardware. A 56 Gbps Inniband FDR CLOS network has been chosen for the event builder. This paper discusses the software design, protocols, and optimizations for exploiting the hardware capabilities. In conclusion, ee present performance measurements from small-scale prototypes and from the full-scale production system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thermal Testing Quality Assurance of 24LCC & 3LCC Electronic Packages

The purpose of this project is to experimentally validate the thermal fatigue life of solder interconnects for a variety of surface mount electronic packages. Over the years, there has been a significant amount of research and analysis in the fracture of solder joints on printed circuit boards. Solder is important in the mechanical and electronic functionality of the component. It is important throughout the life of the product that the solder remains crack and fracture free. The specific type of solder used in this experiment is a 63Sn37Pb eutectic alloy. Each package was manufactured with conformal coating along with and without an underfill material below the device. Conformal coating helps protect the board from environments such as electrostatic discharge and humidity. It is commonly used in broad types of engineering disciplines such as commercial, military, research and development, etc. Conformal coating can also pose a risk for the life of the board because of its high thermal expansion coefficient. This can greatly decrease the life of the product if it regularly sees high temperature variations. This leads to a shorter fatigue life of the solder. The fatigue life is a common mechanical problem in the field of electronic devices. Adding underfill can help increase the fatigue life of the solder. However, applying underfill adds time to manufacturing and production. This ultimately increases the cost per unit. The study of conformal coated printed circuit boards with and without underfill was done on two different surface mount electronic packages. The electronic packages studied were 24 and 3 contact Leadless Ceramic Chips packages. When the package was not underfilled, the coating was allowed to flow underneath. The assembly was analyzed and tested to obtain the best available combination of conformal coating, underfill, and potting to design the most robust and reliable circuit board while keeping in mind certain factors such as cost, manufacturing time, and need. Different types of conformal coatings were considered with and without underfill for each device. 29 of each component were manufactured to have a large sample size and for the sake of individual defects and imperfections. Finite Element Analysis (FEA) was performed by an engineer at Sandia National Laboratories for both Leadless Ceramic Chips. From the FEA results, a test acceleration profile was derived and the number of temperature cycles to fail the solder interconnects were found for three different cases. Experimentation was done as a secondary measure to validate this data to show confidence in the theoretical analysis. Accelerated testing functions as a quality check for the product. Accelerated testing is extremely useful in the research and development phase of engineering. It can save money from the potential of early life defects and the costs that come along with warranties. Accelerated testing makes a weaker design more robust and checks the reliability of a strong design in a shorter period of time. It is extremely helpful in a world where deliverables are in high demand and scheduling is tight. Accelerated testing helps the engineer gain an understanding of what needs to be improved and what works well. There are many different types of accelerated tests. Our circuit boards were accelerated inside a closed thermal chamber because of the high number of use cycles. The ultimate goal of this experimentation is to help identify what will prevent any premature cracking or fracturing in the solder alloy. It is important to understand that underfilling each component may or may not be needed. If underfill is not needed, there are several production benefits.

42 ENGINEERING↗

Analysis of Respirator Cartridge Performance Testing on the 702-AZ Primary Exhauster for the Hanford AY/AZ Tank Farms during a Waste-Disturbing Event

Washington River Protection Solutions (WRPS) conducted tests using two types of chemical cartridges for use in air-purifying respirators (APR) to determine the period of time that the cartridges would provide adequate performance1 for APRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from vapors exiting the 702-AZ Primary Exhauster for the Hanford AY-AZ tank farms. Unlike prior cartridge testing on the 702-AZ Primary Exhauster, the recent tests were performed during a waste-disturbing event. The Occupational Safety and Health Administration (OSHA) identifies cartridge testing as a valid approach for establishing a cartridge change schedules. Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate the cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted from February 10–11, 2017, on a slipstream from the 702-AZ exhauster fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina), were assessed on separate days. Sample media (sorbent tubes) and canisters (e.g., Summa) sampling were used to collect samples of the vapor stream entering and exiting the respirator cartridge and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of ITM Oxygen Technology for Low-cost and Low-emission Gasification and Other Industrial Applications

Air Products carried out a scope of work under DOE Award No. DE-FE0012065 “Development of ITM Oxygen Technology for Low-cost and Low-emission Gasification and Other Industrial Applications” with subcontractors Ceramatec, Penn State, and WorleyParsons. The scope of work under this award was aimed at furthering the development of the Ion Transport Membrane (ITM) Oxygen production process toward a demonstration-scale facility known as the Oxygen Development Facility (ODF). Specific activities will help to enable design and construction of the ODF through advancement of a number of challenging technical elements that are required to manage risk in the initial deployment of ITM technology. Major objectives of the work included developing ITM Oxygen ceramic membrane materials with improved performance and reliability, optimizing ceramic module geometry and fabrication methods, testing module performance, trialing the improved fabrication process at commercial scale in the Ceramic Membrane Module Fabrication Facility (CerFab), and advancing engineering development of the ITM oxygen production process, including vessel design and contaminant control measures to prepare for deployment of the ODF. The comprehensive report that follows details the team’s work, which includes several notable accomplishments: 1) compressive creep, a likely limiter of ceramic module lifetime in service, was demonstrated to be retarded by an order of magnitude by changes in material formulation, module joining dimensions, and internal wafer geometry; 2) two promising new materials were shown to be superior to the incumbent ITM material in a key material parameter related to oxygen flux; 3) module degradation mechanisms were identified following operation in large pilot-scale equipment; 4) options for utilizing ITM in a coal-to-liquids (CTL) facility to enable liquids production with carbon capture were identified and studied; and 5) the benefits of potential improvements to the technology were assessed for their cost impact on ITM Oxygen applications to clean power, fuels, and other applications.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Development of ITM Oxygen Technology for Low-cost and Low-emission Gasification and Other Industrial Applications

Air Products carried out a scope of work under DOE Award No. DE-FE0012065 “Development of ITM Oxygen Technology for Low-cost and Low-emission Gasification and Other Industrial Applications” with subcontractors Ceramatec, Penn State, and WorleyParsons. The scope of work under this award was aimed at furthering the development of the Ion Transport Membrane (ITM) Oxygen production process toward a demonstration-scale facility known as the Oxygen Development Facility (ODF). Specific activities will help to enable design and construction of the ODF through advancement of a number of challenging technical elements that are required to manage risk in the initial deployment of ITM technology. Major objectives of the work included developing ITM Oxygen ceramic membrane materials with improved performance and reliability, optimizing ceramic module geometry and fabrication methods, testing module performance, trialing the improved fabrication process at commercial scale in the Ceramic Membrane Module Fabrication Facility (CerFab), and advancing engineering development of the ITM oxygen production process, including vessel design and contaminant control measures to prepare for deployment of the ODF. The comprehensive report that follows details the team’s work, which includes several notable accomplishments: 1) compressive creep, a likely limiter of ceramic module lifetime in service, was demonstrated to be retarded by an order of magnitude by changes in material formulation, module joining dimensions, and internal wafer geometry; 2) two promising new materials were shown to be superior to the incumbent ITM material in a key material parameter related to oxygen flux; 3) module degradation mechanisms were identified following operation in large pilot-scale equipment; 4) options for utilizing ITM in a coal-to-liquids (CTL) facility to enable liquids production with carbon capture were identified and studied; and 5) the benefits of potential improvements to the technology were assessed for their cost impact on ITM Oxygen applications to clean power, fuels, and other applications.

42 ENGINEERING↗

wtDigiTwin (Wind Turbine Digital Twin) [SWR-21-15]

This wind turbine digital twin software (wtDigiTwin) provides a digital twin solution for wind turbine applications. The focus of wtDigiTwin is to estimate loads, motions and environmental conditions for an operating wind turbine. The program uses supervisory control and data acquisition (SCADA) measurements as inputs, together with a wind turbine model. The wind industry is currently challenged by the high cost of operation and maintenance. These costs could be mitigated if component failures are predicted, but such predictions are difficult unless the turbines are equipped with expensive measuring devices. The alternative is to use a digital twin such as wtDigiTwin to estimate the necessary signals. wtDigiTwin can perform online prediction of signals that are otherwise not measured, using a limited set of reliable measurements and a physics-based model. The predicted signals can be used in applications that have direct cost benefits: 1) real-time estimation of the fatigue consumption of key components of the wind turbine; 2) root cause analyses and failure detections ; 3) lifetime reassessments ; 4) improvements to follow-on designs. The current version provides examples to estimate wind speed, thrust, torque, tower-top position, and tower loads on an onshore wind turbine using the following measurements tower top acceleration, generator torque, pitch, and rotational speed. The model combines a linear state-space model, a wind speed estimator, and a Kalman filter algorithm that integrates measurements with the state model to perform state estimations. The state space model is obtained either using OpenFAST linearizations, or using the yams package provided with the software.

Branlard, Emmanuel↗

Development of risk mitigation guidance for sensor placement inside mechanically ventilated enclosures – Phase 1

Guidance on Sensor Placement was identified as the top research priority for hydrogen sensors at the 2018 HySafe Research Priority Workshop on hydrogen safety in the category Mitigation, Sensors, Hazard Prevention, and Risk Reduction. This paper discusses the initial steps (Phase 1) to develop such guidance for mechanically ventilated enclosures. This work was initiated as an international collaborative effort to respond to emerging market needs related to the design and deployment equipment for hydrogen infrastructure that is often installed in individual equipment cabinets or ventilated enclosures. The ultimate objective of this effort is to develop guidance for an optimal sensor placement such that, when integrated into a facility design and operation, will allow earlier detection at lower levels of incipient leaks, leading to significant hazard reduction. Reliable and consistent early warning of hydrogen leaks will allow for the risk mitigation by reducing or even eliminating the probability of escalation of small leaks into large and uncontrolled events. To address this issue, a study of a real-world mechanically ventilated enclosure containing GH2 equipment was conducted, where CFD modeling of the hydrogen dispersion (performed by AVT and UQTR, and independently by the JRC) was validated by the NREL Sensor laboratory using a Hydrogen Wide Area Monitor (HyWAM) consisting of a 10-point gas and temperature measurement analyzer. In the release test, helium was used as a hydrogen surrogate. Expansion of indoor releases to other larger facilities (including parking structures, vehicle maintenance facilities and potentially tunnels) and incorporation into QRA tools, such as HyRAM is planned for Phase 2. It is anticipated that results of this work will be used to inform national and international standards such as NFPA 2 Hydrogen Technologies Code, Canadian Hydrogen Installation Code (CHIC) and relevant ISO/TC 197 and CEN documents.

08 HYDROGEN↗

Design and performance of the Fermilab Constant Fraction Discriminator ASIC

Here, we present the design and performance characterization results of the novel Fermilab Constant Fraction Discriminator ASIC (FCFD) developed to readout low gain avalanche detector (LGAD) signals by directly using a constant fraction discriminator (CFD) to measure signal arrival time. Silicon detectors with time resolutions less than 30ps will play a critical role in future collider experiments, and LGADs have been demonstrated to provide the required time resolution and radiation tolerance for many such applications. The FCFD has a specially designed discriminator that is robust against amplitude variations of the signal from the LGAD that normally requires an additional correction step when using a traditional leading edge discriminator. The application of the CFD directly in the ASIC promises to be more reliable and reduces the complication of evolving time-walk corrections throughout the operational lifetime of the detector system. We will present a summary of the measured performance of the FCFD for input signals generated by internal charge injection, LGAD signals from an infrared laser, and LGAD signals from minimum-ionizing particles. The mean time response for LGAD signals with charge ranging between 5 and 26 fC has been measured to vary no more than 10ps, orders of magnitude more stable than an uncorrected leading edge discriminator based measurement, and effectively removes the need for any additional time-walk correction. The measured contribution to the time resolution from the FCFD ASIC is found to be 10ps for signals with charge above 20fC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of Cathode Materials with Lithium-Metal Anodes: Baseline Performance and Protocol Standardization of Coin Cells

The collaborative evaluation of electrode materials across multiple research entities requires standardized electrochemical testing protocols to produce reliable, one-to-one comparisons between different systems of interest. Similar to the work done by Long et al. on protocol standardization for coin-cell testing with graphite anodes [J. Electrochem. Soc., 163, A2999, (2016)], here we introduce two standardized testing protocols designed to quickly evaluate important electrochemical properties of cathode materials using lithium-metal anodes. The two protocols measure kinetic and thermodynamic capacity losses, rate- and voltage-dependent cycling capacities, instabilities at high voltage and high cycling rate, and overpotentials at various states of charge. We then apply these protocols to four commercially available cathode materials to establish benchmark performance metrics that can be used to screen and evaluate new cathode materials.

25 ENERGY STORAGE↗

Novel HPGe Probe solution for Harsh Environments

In situ measurement is a privileged way of monitoring radioactive contamination compared to analyzing samples in a distant, specialized laboratory. Scintillators based spectrometers offer small footprints and are easy to easy to use, however they do not provide an accurate nuclide identification capability and activities measurement because notably of their limited energy resolution, for instance when low minimum detectable activity (MDA) are required, or in complex mixture of sources. On the other hand, High Purity Germanium (HPGe) detectors provide unmatched nuclide identification capability with the lowest MDA but they are not always of practical use on the field because the crystal needs to be cooled down to liquid nitrogen temperature, increasing the overall weight, bulkiness and complexity of the measurement. This paper presents the configuration and performance of a novel turnkey and compact HPGe solution developed by Canberra for radionuclide identification under harsh environments. Radio-contaminations surveys now can be undertaken outdoor under various weather conditions, in contaminated areas, underground or underwater locations (including under sea water), with fast on site deployment. The spectrometer is also designed in a small diameter tubular shape to offer minimal footprint for an operation in narrow and confined spaces. Besides, this innovative design does not mitigate the performances nor the reliability experienced with standard laboratory-grade HPGe spectrometers. This achievement relies on advanced technologies such as the encapsulation of the crystal in ultra-high vacuum (UHV) which provides higher robustness and does not requires thermal cycles faced with regular HPGe equipment. It also relies on a low vibration, low consumption electrical cooler so that no liquid nitrogen is being used. The detector is connected to a state-of-the-art digital spectroscopy suite embedded in an autonomous acquisition station monitoring the cryo-cooler and including the spectroscopy software. This system presented is therefore a new solution to perform high resolution spectroscopy where no current products are compact or robust enough to be installed, for instance for soil and water decontamination measurement when anthropogenic radioactive sources must be identified from natural ones or when low contamination levels are expected, the MDA being 3 to 5 times higher than scintillator-based detectors of similar sizes. Environmental inspection such as well logging for geophysics and mining, water contamination monitoring, or decommissioning works can thus benefits from both ruggedness, mobility without compromise on the nuclide identification or activity measurement capability. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advanced Power Electronics and Electric Machines

NLR's advanced power electronics and electric machines (APEEM) research group develops world-class experimental and modeling capabilities to design and evaluate efficient and reliable power electronics and electric machines, as well as innovative thermal management systems to maximize their performance. They also design, fabricate, and characterize advanced power electronics packaging and are developing state-of-health monitoring techniques.

25 ENERGY STORAGE↗