Search NASA⌕ Search

SEARCH · Search NASA

Results for “Performance Deviation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

The failure analysis, redesign, and final preparation of the Brilliant Eyes Thermal Storage Unit for flight testing

This paper describes the engineering thought process behind the failure analysis, redesign, and rework of the flight hardware for the Brilliant Eyes Thermal Storage Unit (BETSU) experiment. This experiment was designed to study the zero-g performance of 2-methylpentane as a suitable phase change material. This hydrocarbon served as the cryogenic storage medium for the BETSU experiment which was flown 04 Mar 94 on board Shuttle STS-62. Ground testing had indicated satisfactory performance of the BETSU at the 120 Kelvin design temperature. However, questions remained as to the micro-gravity performance of this unit; potential deviations in ground (1 g) versus space flight (0 g) performance, and how the unit would operate in a realistic space environment undergoing cyclical operation. The preparations and rework performed on the BETSU unit, which failed initial flight qualification, give insight and lessons learned to successfully develop and qualify a space flight experiment.

Lamkin, T.↗

Investigation of Best-Practices and Computationally Inexpensive Radiative Exchange Models for Discrete Element Method Modeling of Aluminosilicate Particles in Concentrating Solar Power Environments

Chemically inert, aluminosilicate based particles have been investigated as both a thermal transport and sensible energy storage medium for concentrating solar power facilities. These particles will experience a wide range of operating temperatures (300-1000 K) and handling conditions (dense to dilute falling particle curtains, dense granular flows, or dense structures), requiring specially-designed and optimized infrastructures. The relative influence of collisional and frictional interactions between particles varies based on temperature-dependent particulate properties and greatly impacts the bulk, granular flow behavior. These underlying physics are captured using discrete element method modeling tools. However, this modeling method is computationally expensive as each particle position and interaction is tracked during the simulation. These modeling methods are further complicated by introducing temperature-dependent particle properties, high-temperature radiative exchange, and directional irradiation sources experienced by granular flows in concentrating solar power environments. In this study, coupled experimental and numerical slump testing of aluminosilicate particles was performed and computationally efficient radiative exchange models were evaluated to establish best-practices for discrete element method models for concentrating solar power environments. The three particle types investigated included Carbobead HSP 30 /60, Carbobead CP 30/60, and Granusil 4030. Existing modeling limitations and computationally-efficient multi-modal heat transfer models were evaluated using Aspherix®, a commercial discrete element method software. High-temperature (< 1073 K) slump testing of aluminosilicate particles was performed to investigate the deviation between experimentally-observed and numerically-predicted angles of repose introduced by computation-time reduction practices including the relaxation of the particle elastic modulus and coarse-graining. Coarse-graining is used to use a single modeled particle that is representative of a collection of smaller particles, decreasing the computational cost at the expense of geometric accuracy. Additionally, relaxation of the elastic modulus is used to reduce computational time at the expense of an increased, modeled particle overlap. Prior studies have determined that aluminosilicate particles retain a high elastic modulus at high temperatures (< 1073 K), requiring small simulation timesteps to ensure resolved contact forces resemble appropriate solid mechanics. A parametric study was performed to evaluate the influence of computation time improvements on the deviation between experimental and modeled angle of repose across high temperatures < 1073 K. Additionally, numerical case studies were performed on candidate particle systems at varying porosities and temperatures. These studies were performed to investigate the influence of computationally-efficient radiative-exchange modeling methods coupled to Aspherix® on modeled accuracy and computation time. The recently-developed distance-based approximation was evaluated in estimating radiative exchange between particles and participating surfaces located in close proximity. The distance based approximation was developed to use tabulated estimates of the radiative distribution factor between individual particles and surfaces in close proximity (< 40 particle radii). These methods were expanded to the aluminosilicate particles of interest, including the influence of particle size distributions. To capture radiative exchange between particles and surfaces not in close proximity (> 40 particle radii) and to capture the absorption of directional irradiation from concentrating solar resources, a volumetrically-averaged radiative distribution factor was calculated between the modeled granular flow and surfaces using Monte Carlo ray-tracing for participating media. Volume-averaged absorption and scattering coefficients were predicted using a volumetric discretization of the modeled domain with monodisperse approximations based on geometric optics and experimentally-determined scattering phase functions for aluminosilicate particles.

14 SOLAR ENERGY↗

Automated detection of photovoltaic cleaning events: A performance comparison of techniques as applied to a broad set of labeled photovoltaic data sets

Extracting accurate soiling loss information from photovoltaic (PV) production data first requires segmenting the time series data per natural or manually occurring cleaning events. Maintenance logs are often incomplete, rain data are often unavailable, and the debate on rain thresholds for cleaning and dew or wind cleanings is still ongoing. The present work aims to overtake these issues by improving automated methods to detect these cleaning events and therefore improve extraction of soiling loss information. Time series power production data from 22 PV inverters were labeled for natural or manually occurring cleaning events. The data sets were carefully selected to include varying degrees of soiling, cleaning events, and noise. Several algorithms, including filtering logic and change point detection, were examined for efficacy at detecting the labeled cleanings. All the methods introduced except for changepoint detection showed significant improvement at detecting the labeled cleaning events per the mean F 1 score. Furthermore, the highest performing cleaning detection algorithm achieved an absolute increase in the mean F 1 score of 43% over the default version of the RdTools stochastic rate and recovery (SRR) algorithm. The highest performing algorithm included irradiance filtering and a cleaning detection threshold, adjusted based on the 40-day centered rolling median of the absolute day-to-day deviations in the daily performance index (PI). Furthermore, these improvements are promising as cleaning detection is an essential step in the automated analysis of PV soiling.

14 SOLAR ENERGY↗

Analysis of spacecraft on-orbit anomalies and lifetimes

Analyses of the on-orbit performance of forty-four unmanned NASA spacecraft are presented. Included are detailed descriptions and classifications of over 600 anomalies; each anomalous incident represents one reported deviation from expected spacecraft performance. Charts depicting satellite lifetimes and the performance of their major subsystems are included. Engineering analyses to further investigate the kinds and frequencies of various classes of anomalies have been conducted. An improved method for charting spacecraft capability as a function of time on orbit is explored.

Bloomquist, C.↗

An initial test of a normative Figure Of Merit for the quality of overall task performance

An overall indicator, or Figure Of Merit (FOM), of the quality of crew/vehicle system performance is needed to establish the effect of workload on efficiency and to identify overload conditions. A normative FOM is proposed in which performance is measured on a representative task and a normative data base obtained. FOMs for subsequent executions of the task are then reported in terms of weighted deviations from average task performance. Performance of discrete tasks is measured primarily in terms of subtask time and errors. Discrete task performance is then combined with a measure of continuous vehicle control. In order to test the normative FOM procedure, the technique was applied to an existing set of data from a simulated landing task in which standard communications with ATC was compared with a data link communications system. The results indicated that while mean task performance was not affected, task variability, as measured by the FOM, was significantly higher when data link communications were used. In order to establish the sensitivity of the normative FOM method, further testing of the measure is recommended.

Lemay, Moira↗

Multiple-Zone Variable Refrigerant Flow System Modeling and Equipment Performance Mapping

We developed a variable refrigerant flow (VRF) vapor compression system model, which has five indoor units, one outdoor unit and one water heater. The VRF system can run simultaneous space conditioning (cooling or heating) and water heating. The indoor units and outdoor unit use fin-&-tube coil heat exchangers, and the water heater uses a tube-in-tube heat exchanger. The fin-&-tube coil heat exchangers are modeled using a segment-by-segment approach and the tube-in-tube water heater is modeled using a phase-by-phase approach. The compressor used is a variable-speed rotary design. We calibrated our model against a manufacturer s product literature. Based on the vapor compression system model, we investigated the methodology for generating VRF equipment performance maps, which can be used for energy simulations in TRNSYS and EnergyPlus, etc. In the study, the major independent variables for mapping are identified and the deviations between the simplified performance map and the actual equipment system simulation are quantified.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Continuous-Energy ENDF/B-VIII.0 Cross Section and SCALE 6.2.4 Performance for Nuclear Criticality Safety Applications: 1 H, C, 58,60 Ni, 182,183,184,186 W, 235,238 U, 239 Pu

As part of the nuclear data evaluation and validation cycle, the ENDF/B-VIII.0 cross-section library released in 2018 requires testing to determine areas of improvement and deterioration. Previous work by the authors investigated the performance of 16 O, 56 Fe, and 63,65 Cu cross sections, with this study acting as an extension of the prior work. In addition to the isotopes and nuclear criticality safety benchmarks of interest to the prior work, benchmarks from the International Criticality Safety Benchmark Evaluation Project Handbook were selected for their k eff sensitivity to 1 H, C, 58,60 Ni, 182,183,184,186 W, 235,238U, or 239 Pu cross sections and were modeled in the SCALE code system maintained by Oak Ridge National Laboratory. In total, 253 benchmark configurations were selected for their sensitivities and modeled using SCALE 6.2.4 Criticality Safety Analysis Sequences (CSAS) continuous-energy Monte Carlo k eff calculations. This collection includes and expands upon the 99 benchmarks in the prior work. The AMPX-processed ENDF/B-VIII.0 library was decomposed into individual ENDF/B-VIII.0 datum libraries for each isotope of interest. Doing so allowed for the individual substitution of an ENDF/B-VIII.0 cross section in the place of ENDF/B-VII.1, determining isotope-specific effects of ENDF/B-VIII.0 relative to ENDF/B-VII.1. Full library calculations with entirely ENDF/B-VII.1 data or entirely ENDF/B-VIII.0 data were also executed. As a measure of performance, the average relative deviation was determined as the ratio of the deviation between calculated and experimental keff to the propagated calculational and experimental uncertainty. With calculated full library and isotope-specific ENDF/B-VIII.0 k eff ’s, an optimized combination of data libraries was estimated and confirmed with SCALE calculations. This showed that reverting 239 Pu, 58 Ni, 16 O, and 65 Cu cross sections to ENDF/B-VII.1 resulted in improved performance relative to the full ENDF/B-VIII.0 library. Across all 253 benchmarks, the average relative deviation was 1.29σ for the full ENDF/B-VII.1 library, 1.17σ for the full ENDF/B-VIII.0 library, and 0.97σ for the optimized combination. The reversion of 239 Pu, 58 Ni, 16 O, and 65 Cu cross sections to ENDF/B-VII.1 in the 99 benchmarks of the prior work resulted in further improved experimental agreement compared to the previously reported improvement from 16 O and 65 Cu alone. Therefore, it is suggested that applications with significant sensitivities to 239 Pu, 58 Ni, 16 O, and 65 Cu consider their choice of nuclear data library.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Repeatability of Cryogenic Multilayer Insulation

Due to the variety of requirements across aerospace platforms, and one off projects, the repeatability of cryogenic multilayer insulation has never been fully established. The objective of this test program is to provide a more basic understanding of the thermal performance repeatability of MLI systems that are applicable to large scale tanks. There are several different types of repeatability that can be accounted for: these include repeatability between multiple identical blankets, repeatability of installation of the same blanket, and repeatability of a test apparatus. The focus of the work in this report is on the first two types of repeatability. Statistically, repeatability can mean many different things. In simplest form, it refers to the range of performance that a population exhibits and the average of the population. However, as more and more identical components are made (i.e. the population of concern grows), the simple range morphs into a standard deviation from an average performance. Initial repeatability testing on MLI blankets has been completed at Florida State University. Repeatability of five GRC provided coupons with 25 layers was shown to be +/- 8.4 whereas repeatability of repeatedly installing a single coupon was shown to be +/- 8.0. A second group of 10 coupons have been fabricated by Yetispace and tested by Florida State University, through the first 4 tests, the repeatability has been shown to be +/- 16. Based on detailed statistical analysis, the data has been shown to be statistically significant.

multilayer insulation↗

Repeatability of Cryogenic Multilayer Insulation

Due to the variety of requirements across aerospace platforms, and one off projects, the repeatability of cryogenic multilayer insulation has never been fully established. The objective of this test program is to provide a more basic understanding of the thermal performance repeatability of MLI systems that are applicable to large scale tanks. There are several different types of repeatability that can be accounted for: these include repeatability between multiple identical blankets, repeatability of installation of the same blanket, and repeatability of a test apparatus. The focus of the work in this report is on the first two types of repeatability. Statistically, repeatability can mean many different things. In simplest form, it refers to the range of performance that a population exhibits and the average of the population. However, as more and more identical components are made (i.e. the population of concern grows), the simple range morphs into a standard deviation from an average performance. Initial repeatability testing on MLI blankets has been completed at Florida State University. Repeatability of five GRC provided coupons with 25 layers was shown to be +/- 8.4% whereas repeatability of repeatedly installing a single coupon was shown to be +/- 8.0%. A second group of 10 coupons have been fabricated by Yetispace and tested by Florida State University, through the first 4 tests, the repeatability has been shown to be +/- 15-25%. Based on detailed statistical analysis, the data has been shown to be statistically significant.

multilayer insulation↗

Evidence for the charge asymmetry in $pp$ → $t\bar{t}$ production at $\sqrt{s}$ = 13 TeV with the ATLAS detector

Inclusive and differential measurements of the top–antitop ($t\bar{t}$) charge asymmetry ${A}_{C}^{t\bar{t}}$ and the leptonic asymmetry ${A}_{C}^{\ell\bar{\ell}}$ are presented in proton–proton collisions at $\sqrt{s}$ = 13 TeV recorded by the ATLAS experiment at the CERN Large Hadron Collider. The measurement uses the complete Run 2 dataset, corresponding to an integrated luminosity of 139 fb –1 , combines data in the single-lepton and dilepton channels, and employs reconstruction techniques adapted to both the resolved and boosted topologies. A Bayesian unfolding procedure is performed to correct for detector resolution and acceptance effects. The combined inclusive $t\bar{t}$ charge asymmetry is measured to be ${A}_{C}^{t\bar{t}}$ = 0.0068 ± 0.0015, which differs from zero by 4.7 standard deviations. Differential measurements are performed as a function of the invariant mass, transverse momentum and longitudinal boost of the $t\bar{t}$ system. Both the inclusive and differential measurements are found to be compatible with the Standard Model predictions, at next-to-next-to-leading order in quantum chromodynamics perturbation theory with next-to-leading-order electroweak corrections. The measurements are interpreted in the framework of the Standard Model effective field theory, placing competitive bounds on several Wilson coefficients.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Influence of Electrotactile Tongue Feedback on Controlling Upright Stance during Rotational and/or Translational Sway-referencing with Galvanic Vestibular Stimulation

Integration of multi-sensory inputs to detect tilts relative to gravity is critical for sensorimotor control of upright orientation. Displaying body orientation using electrotactile feedback to the tongue has been developed by Bach-y-Rita and colleagues as a sensory aid to maintain upright stance with impaired vestibular feedback. MacDougall et al. (2006) recently demonstrated that unpredictably varying Galvanic vestibular stimulation (GVS) significantly increased anterior-posterior (AP) sway during rotational sway referencing with eyes closed. The purpose of this study was to assess the influence of electrotactile feedback on postural control performance with pseudorandom binaural bipolar GVS. Postural equilibrium was measured with a computerized hydraulic platform in 10 healthy adults (6M, 4F, 24-65 y). Tactile feedback (TF) of pitch and roll body orientation was derived from a two-axis linear accelerometer mounted on a torso belt and displayed on a 144-point electrotactile array held against the anterior dorsal tongue (BrainPort, Wicab, Inc., Middleton, WI). Subjects were trained to use TF by voluntarily swaying to draw figures on their tongue, both with and without GVS. Subjects were required to keep the intraoral display in their mouths on all trials, including those that did not provide TF. Subjects performed 24 randomized trials (20 s duration with eyes closed) including four support surface conditions (fixed, rotational sway-referenced, translating the support surface proportional to AP sway, and combined rotational-translational sway-referencing), each repeated twice with and without GVS, and with combined GVS and TF. Postural performance was assessed using deviations from upright (peak-to-peak and RMS sway) and convergence toward stability limits (time and distance to base of support boundaries). Postural stability was impaired with GVS in all platform conditions, with larger decrements in performance during trials with rotation sway-referencing. Electrotactile feedback improved performance with GVS toward non-GVS levels, again with the greatest improvement during trials with rotation sway-referencing. These results demonstrate the effectiveness of tongue electrotactile feedback in providing sensory substitution to maintain postural stability with distorted vestibular input.

Wood, Scott J.↗

Design of an optical PPM communication link in the presence of component tolerances

A systematic approach is described for estimating the performance of an optical direct detection pulse position modulation (PPM) communication link in the presence of parameter tolerances. This approach was incorporated into the JPL optical link analysis program to provide a useful tool for optical link design. Given a set of system parameters and their tolerance specifications, the program will calculate the nominal performance margin and its standard deviation. Through use of these values, the optical link can be designed to perform adequately even under adverse operating conditions.

Chen, C.-C.↗

Sea level static calibration of a compact multimission aircraft propulsion simulator with inlet flow distortion

Wind tunnel tests of propulsion-integrated aircraft models have identified inlet flow distortion as a major source of compressor airflow measurement error in turbine-powered propulsion simulators. Consequently, two Compact Multimission Aircraft Propulsion Simulator (CMAPS) units were statically tested at sea level ambient conditions to establish simulator operating performance characteristics and to calibrate the compressor airflow against an accurate bellmouth flowmeter in the presence of inlet flow distortions. The distortions were generated using various-shaped wire mesh screens placed upstream of the compressor. CMAPS operating maps and performance envelopes were obtained for inlet total pressure distortions (ratio of the difference between the maximum and minimum total pressures to the average total pressure) up to 35 percent, and were compared to baseline simulator operating characteristics for a uniform inlet. Deviations from CMAPS baseline performance were attributed to the coupled variation of both compressor inlet-flow distortion and Reynolds number index throughout the simulator operating envelope for each screen configuration. Four independent methods were used to determine CMAPS compressor airflow; direct compressor inlet and discharge measurements, an entering/exiting flow-balance relationships, and a correlation between the mixer pressure and the corrected compressor airflow. Of the four methods, the last yielded the least scatter in the compressor flow coefficient, approximately + or - 3 percent over the range of flow distortions.

Won, Mark J.↗

Lighting installations

Model computations that give the lay-out of a lighting installation have to be implemented in the real world. There, deviations from the ideal performance of just about every element of the installation will be felt. A list of possible sources of non-ideal behavior, based on practical experience, are: lamps, ballasts, reflectors, mounting position, sagging of lamps, and soiling. It is clear that with all possible deviations from the ideal the homogeneity of a real lighting installation can never be as good as the one computed. The only way to make sure it is nearly as good is by measurement of the actual light distribution. Then, an occasional adjustment or replacement may often yield a satisfactory result. This measurement should really be part of the installation contract.

Schurer, Kees↗

Comparison of the performance of TLD, OSL and RPL personal dosimetry systems to the American National Standard Institute (ANSI) test categories

The Laboratory Accreditation Program (LAP) tests the capability and performance of the United States Department of Energy's (USDOE) facilities to accurately measure and quantify the whole-body and extremity radiation equivalent doses to the occupational workers. The dosimetry methods used in personal dosimetry can be Thermoluminescence (TL), Optically Stimulated Luminescence (OSL) and Radiophotoluminescence (RPL), among other techniques available. Currently, the TL (LiF:Mg,Ti) and OSL (Al 2 O 3 :C) dosimetry systems are DOELAP-accredited for occupational dose measurements and regulatory reporting. In this study, the performance of a beryllium oxide (BeO) OSL dosimetry system and of a silver-doped phosphate glass RPL dosimetry system is compared against the performance of an accredited LiF:Mg,Ti TL dosimetry system. The bias and standard deviation in each of the performance test categories are compared between these three systems for exposures to photons, beta, and mixed radiation fields with the criteria established by the American National Standard Institute (ANSI) and Health Physics Society (HPS) N13.11-2022 standard. The practical implementation of the dosimetry program and its equivalency to the occupational personal equivalent dose H p (0.07) and H p (10) measurements were evaluated. The TL, OSL and RPL dosimetry systems passed the ANSI performance test criteria for H p (0.07) and H p (10) occupational dose measurements and met the DOELAP accreditation requirements.

61 RADIATION PROTECTION AND DOSIMETRY↗

The Power Curve Working Group's assessment of wind turbine power performance prediction methods

Wind turbine power production deviates from the reference power curve in real-world atmospheric conditions. Correctly predicting turbine power performance requires models to be validated for a wide range of wind turbines using inflow in different locations. The Share-3 exercise is the most recent intelligence-sharing exercise of the Power Curve Working Group, which aims to advance the modeling of turbine performance. The goal of the exercise is to search for modeling methods that reduce error and uncertainty in power prediction when wind shear and turbulence digress from design conditions. Herein, we analyze data from 55 wind turbine power performance tests from nine contributing organizations with statistical tests to quantify the skills of the prediction-correction methods. We assess the accuracy and precision of four proposed trial methods against the baseline method, which uses the conventional definition of a power curve with wind speed and air density at hub height. The trial methods reduce power-production prediction errors compared to the baseline method at high wind speeds, which contribute heavily to power production; however, the trial methods fail to significantly reduce prediction uncertainty in most meteorological conditions. For the meteorological conditions when a wind turbine produces less than the power its reference power curve suggests, using power deviation matrices leads to more accurate power prediction. We also determine that for more than half of the submissions, the data set has a large influence on the effectiveness of a trial method. Overall, this work affirms the value of data-sharing efforts in advancing power curve modeling and establishes the groundwork for future collaborations.

17 WIND ENERGY↗

Performance analysis of a generalized concurrent error detection procedure

A general procedure for error detection in complex systems, called the data block capture and analysis monitoring process, is described and analyzed. It is assumed that, in addition to being exposed to potential external fault sources, a complex system will in general always contain embedded hardware and software fault mechanisms which can cause the system to perform incorrect computations and/or produce incorrect output. Thus, in operation, the system continuously moves back and forth between error and no-error states. These external fault sources or internal fault mechanisms are extremely difficult to detect. The data block capture and analysis monitoring process is concerned with detecting deviations from the normal performance of the system, known as errors, which are symptomatic of fault conditions. The process consists of repeatedly recording a fixed amount of data from a set of predetermined observation lines of the system being monitored (i.e., capturing a block of data) and then analyzing the captured block in an attempt to determine whether the system is functioning correctly. The performances of linear, quadratic, and logarithmic data analysis algorithms are rigorously characterized in terms of the probability of correctly detecting an error, the expectation and variance of the number of false alarms per error, and the expectation and variance of the latency in detection of errors. Insight into the nature of the general problem of error detection is obtained.

Blough, Douglas M.↗

Reducing Design Risk Using Robust Design Methods: A Dual Response Surface Approach

Space transportation system conceptual design is a multidisciplinary process containing considerable element of risk. Risk here is defined as the variability in the estimated (output) performance characteristic of interest resulting from the uncertainties in the values of several disciplinary design and/or operational parameters. Uncertainties from one discipline (and/or subsystem) may propagate to another, through linking parameters and the final system output may have a significant accumulation of risk. This variability can result in significant deviations from the expected performance. Therefore, an estimate of variability (which is called design risk in this study) together with the expected performance characteristic value (e.g. mean empty weight) is necessary for multidisciplinary optimization for a robust design. Robust design in this study is defined as a solution that minimizes variability subject to a constraint on mean performance characteristics. Even though multidisciplinary design optimization has gained wide attention and applications, the treatment of uncertainties to quantify and analyze design risk has received little attention. This research effort explores the dual response surface approach to quantify variability (risk) in critical performance characteristics (such as weight) during conceptual design.

Unal, Resit↗