Search NASA⌕ Search

SEARCH · Search NASA

Results for “Performance Deviation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

TH-CD-207B-12: Quantification of Clinical Feedback On Image Quality Differences Between Two CT Scanner Models

Purpose: This work sought to quantify a radiology team’s assessment of image quality differences between two CT scanner models currently in clinical use, with emphasis on noise and low-contrast detectability (LCD). Methods: A water phantom and a Kagaku anthropomorphic body phantom were scanned on GE Discovery CT750 HD and LightSpeed VCT scanners (4 each) with identical scan parameters and reconstructed to 2.5mm/5.0mm thicknesses. Images of water phantom were analyzed at the scanner console with a built-in LCD tool that uses statistical methods to compute requisite CT-number contrast for 95% confidence in detection of a user-defined object size. LCD value was computed for 5mm, 3mm, and 1mm objects. Analysis of standard deviation and LCD values were performed on Kagaku phantom images within liver, stomach, and spleen. LCD value was computed for 4mm, 3mm, and 1mm objects using a benchmarked MATLAB implementation of the GE scanner-console tool. Results: Water LCD values were larger (poorer performance) for all HD scanners compared to VCT scanners. Mean scanner model difference in requisite CT-number contrast for 5mm, 3mm, and 1mm objects for 5.0mm/2.5mm images was 3.0%/3.4% (p=0.02/p=0.10), 5.3%/5.7% (0.00002/0.02), and 8.5%/8.2% (0.0004/0.002), respectively. Mean standard deviations within Kagaku phantom ROIs were greater in HD compared to VCT images, with mean differences for the liver, stomach, and spleen for 5.0mm/2.5mm of 16%/12% (p=0.04/0.10), 8%/12% (0.15/0.11), and 16%/15% (0.05/0.11), respectively. Mean LCD value difference between HD and VCT scanners over all ROIs for 4mm, 3m, and 1mm objects and 5.0mm/2.5mm was 34%/9%, 16%/8%, and 18%/10%, respectively. HD scanners outperformed VCT scanners only for the 4mm stomach object. Conclusion: Using both water and anthropomorphic phantoms, it was shown that HD scanners are outperformed by VCT scanners with respect to noise and LCD in a consistent and in most cases statistically significant manner. The relationship between statistical and clinical significance demands further work.

60 APPLIED LIFE SCIENCES↗

GPS Spoofing Mitigation and Timing Risk Analysis in Networked Phasor Measurement Units via Stochastic Reachability

To address phasor measurement unit (PMU) vulnerability to spoofing, we propose the use of a set-valued state estimation technique known as stochastic reachability (SR)-based distributed Kalman filter (DKF) that computes secure global positioning system (GPS) timing across a network of receivers. Utilizing SR, we estimate not only GPS time but also its stochastic reachable set, which is parameterized by probabilistic zonotope (p-Zonotope). While requiring known measurement error bounds in only non-spoofed conditions, we designed a two-tiered approach. We first performed measurement-level spoofing mitigation via deviation of a measurement innovation from its expected p-Zonotope. We then performed state-level timing risk analysis via a determination of the intersection probability of the estimated p-Zonotope with an unsafe set that violates IEEE C37.118.1a-2014 standards. Finally, we validated our SR-DKF algorithm by subjecting it to a simulated receiver network to coordinate signal-level spoofing. We demonstrate improved timing accuracy and successful spoofing mitigation via the use of our SR-DKF algorithm. We also validated the robustness of the estimated timing risk as the number of receivers were varied.

47 OTHER INSTRUMENTATION↗

Reduction of baseplate distortion during directed energy deposition using compliant features

Distortion in additive manufacturing (AM) remains a barrier to its adoption in precision industries. Baseplate warpage is one such issue which compromises the feasibility of post-process precision machining. The restriction to thermal contraction of the deposited part, imposed by the baseplate, generates bending moments, that in turn causes warpage. A novel distortion mitigation strategy using baseplates with integrated compliant features, which enables thermal contraction of the build is presented. Six unique design concepts are evaluated, including a solid reference, using two deposition geometries. A laser, hot-wire, directed energy deposition (DED) process is used to deposit a symmetric cylindrical part (C-part) and a T-shaped asymmetric part (T-part). Flatness deviation of baseplates is measured using structured light 3D scanning. Measurements reveal a reduction in net flatness deviation of 58.8% for the C-part and 40.9% for the T-part, compared to the solid reference. While most designs yielded reductions exceeding 30% and 20% for the C- and T-parts, respectively, one configuration resulted in increased deviation. Finite element (FE) simulations are performed to elucidate the underlying mechanisms affecting distortion of compliant baseplates during DED. Despite variations between predictions and measurements, agreement in the general trend is observed. It also revealed that initial flatness errors in baseplates significantly affect its deviation during deposition. Predictions indicate that compliant features significantly affect the thermal distribution as well as the evolution of flatness deviation in the baseplate during deposition. Notably, one design exhibited a reduction in distortion during cooling, following its initial increase during deposition. FE predictions show a maximum reduction of 60.9% and 38.8% in net flatness deviation for the C- and T-parts, respectively. The performance of compliant baseplates is found to be governed by both its the thermal and mechanical characteristics, which are crucial factors to be considered during design.

Mathews, Ritin [ORNL] (ORCID:0000000301440828)↗

Method, system, and computer-readable medium for determining performance characteristics of an object undergoing one or more arbitrary aging conditions

A method, system, and computer-readable medium are described for characterizing performance loss of an object undergoing an arbitrary aging condition. Baseline aging data may be collected from the object for at least one known baseline aging condition over time, determining baseline multiple sigmoid model parameters from the baseline data, and performance loss of the object may be determined over time through multiple sigmoid model parameters associated with the object undergoing the arbitrary aging condition using a differential deviation-from-baseline approach from the baseline multiple sigmoid model parameters. The system may include an object, monitoring hardware configured to sample performance characteristics of the object, and a processor coupled to the monitoring hardware. The processor is configured to determine performance loss for the arbitrary aging condition from a comparison of the performance characteristics of the object deviating from baseline performance characteristics associated with a baseline aging condition.

97 MATHEMATICS AND COMPUTING↗

Fluidization of Group A Glass Particles: Experiments and Preliminary Validation

This work is aimed at providing reliable high-quality data from fluidization experiments. Geldart Group A glass beads are used as bed material. The fluidizing medium is air at atmospheric pressure which enters the system at 40% relative humidity. The air inlet velocity is varied over a broad range from 2 U mf to 26 U mf , where the minimum fluidization velocity, U mf , is 0.608 cm/s. There is not a significant change in the mean values of differential pressure; however, there are noticeable trends in their standard deviation values. Preliminary validation studies are performed using the open-source software Multiphase Flow with Interphase eXchanges (MFiX) developed by the National Energy Technology Laboratory (NETL). The results from Eulerian-Eulerian (MFiX-TFM, two-fluid model) and Eulerian-Lagrangian (MFiX-PIC, particle-in-cell) formulations are compared. The work presented in this report highlights the applicability of MFiX-PIC for large-scale applications, and reveals that PIC simulation offers a suitable alternative to TFM simulation when effects due to multiple components or polydispersity are significant. PIC modeling provides a readily extendible framework for such systems. However, PIC models do rely on an empirical closure for inter-particle stress. Some solution discrepancies were evident in MFiX-PIC predictions which require further analysis. As such, the study underlines the need for a systematic approach to quantify the sources of numerical uncertainty within the PIC model. However, even with known empiricism, MFiX-PIC has demonstrated considerable potential in analyzing gas-solid systems. The results obtained are encouraging and warrant further investigation to improve the predictive capability of MFiX-PIC.

36 MATERIALS SCIENCE↗

Alpha image reconstruction (AIR): A new iterative CT image reconstruction approach using voxel-wise alpha blending

Purpose: Iterative image reconstruction gains more and more interest in clinical routine, as it promises to reduce image noise (and thereby patient dose), to reduce artifacts, or to improve spatial resolution. Among vendors and researchers, however, there is no consensus of how to best achieve these aims. The general approach is to incorporatea priori knowledge into iterative image reconstruction, for example, by adding additional constraints to the cost function, which penalize variations between neighboring voxels. However, this approach to regularization in general poses a resolution noise trade-off because the stronger the regularization, and thus the noise reduction, the stronger the loss of spatial resolution and thus loss of anatomical detail. The authors propose a method which tries to improve this trade-off. The proposed reconstruction algorithm is called alpha image reconstruction (AIR). One starts with generating basis images, which emphasize certain desired image properties, like high resolution or low noise. The AIR algorithm reconstructs voxel-specific weighting coefficients that are applied to combine the basis images. By combining the desired properties of each basis image, one can generate an image with lower noise and maintained high contrast resolution thus improving the resolution noise trade-off. Methods: All simulations and reconstructions are performed in native fan-beam geometry. A water phantom with resolution bar patterns and low contrast disks is simulated. A filtered backprojection (FBP) reconstruction with a Ram-Lak kernel is used as a reference reconstruction. The results of AIR are compared against the FBP results and against a penalized weighted least squares reconstruction which uses total variation as regularization. The simulations are based on the geometry of the Siemens Somatom Definition Flash scanner. To quantitatively assess image quality, the authors analyze line profiles through resolution patterns to define a contrast factor for contrast-resolution plots. Furthermore, the authors calculate the contrast-to-noise ratio with the low contrast disks and the authors compare the agreement of the reconstructions with the ground truth by calculating the normalized cross-correlation and the root-mean-square deviation. To evaluate the clinical performance of the proposed method, the authors reconstruct patient data acquired with a Somatom Definition Flash dual source CT scanner (Siemens Healthcare, Forchheim, Germany). Results: The results of the simulation study show that among the compared algorithms AIR achieves the highest resolution and the highest agreement with the ground truth. Compared to the reference FBP reconstruction AIR is able to reduce the relative pixel noise by up to 50% and at the same time achieve a higher resolution by maintaining the edge information from the basis images. These results can be confirmed with the patient data. Conclusions: To evaluate the AIR algorithm simulated and measured patient data of a state-of-the-art clinical CT system were processed. It is shown, that generating CT images through the reconstruction of weighting coefficients has the potential to improve the resolution noise trade-off and thus to improve the dose usage in clinical CT.

60 APPLIED LIFE SCIENCES↗

Assessment of dedicated low-dose cardiac micro-CT reconstruction algorithms using the left ventricular volume of small rodents as a performance measure

Purpose: Phase-correlated microcomputed tomography (micro-CT) imaging plays an important role in the assessment of mouse models of cardiovascular diseases and the determination of functional parameters as the left ventricular volume. As the current gold standard, the phase-correlated Feldkamp reconstruction (PCF), shows poor performance in case of low dose scans, more sophisticated reconstruction algorithms have been proposed to enable low-dose imaging. In this study, the authors focus on the McKinnon-Bates (MKB) algorithm, the low dose phase-correlated (LDPC) reconstruction, and the high-dimensional total variation minimization reconstruction (HDTV) and investigate their potential to accurately determine the left ventricular volume at different dose levels from 50 to 500 mGy. The results were verified in phantom studies of a five-dimensional (5D) mathematical mouse phantom. Methods: Micro-CT data of eight mice, each administered with an x-ray dose of 500 mGy, were acquired, retrospectively gated for cardiac and respiratory motion and reconstructed using PCF, MKB, LDPC, and HDTV. Dose levels down to 50 mGy were simulated by using only a fraction of the projections. Contrast-to-noise ratio (CNR) was evaluated as a measure of image quality. Left ventricular volume was determined using different segmentation algorithms (Otsu, level sets, region growing). Forward projections of the 5D mouse phantom were performed to simulate a micro-CT scan. The simulated data were processed the same way as the real mouse data sets. Results: Compared to the conventional PCF reconstruction, the MKB, LDPC, and HDTV algorithm yield images of increased quality in terms of CNR. While the MKB reconstruction only provides small improvements, a significant increase of the CNR is observed in LDPC and HDTV reconstructions. The phantom studies demonstrate that left ventricular volumes can be determined accurately at 500 mGy. For lower dose levels which were simulated for real mouse data sets, the HDTV algorithm shows the best performance. At 50 mGy, the deviation from the reference obtained at 500 mGy were less than 4%. Also the LDPC algorithm provides reasonable results with deviation less than 10% at 50 mGy while PCF and MKB reconstruction show larger deviations even at higher dose levels. Conclusions: LDPC and HDTV increase CNR and allow for quantitative evaluations even at dose levels as low as 50 mGy. The left ventricular volumes exemplarily illustrate that cardiac parameters can be accurately estimated at lowest dose levels if sophisticated algorithms are used. This allows to reduce dose by a factor of 10 compared to today's gold standard and opens new options for longitudinal studies of the heart.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Versailles Project on Advanced Materials and Standards interlaboratory study on intensity calibration for x-ray photoelectron spectroscopy instruments using low-density polyethylene

We report the results of a Versailles Project on Advanced Materials and Standards interlaboratory study on the intensity scale calibration of x-ray photoelectron spectrometers using low-density polyethylene (LDPE) as an alternative material to gold, silver, and copper. An improved set of LDPE reference spectra, corrected for different instrument geometries using a quartz-monochromated Al Kα x-ray source, was developed using data provided by participants in this study. Using these new reference spectra, a transmission function was calculated for each dataset that participants provided. When compared to a similar calibration procedure using the NPL reference spectra for gold, the LDPE intensity calibration method achieves an absolute offset of ~3.0% and a systematic deviation of ±6.5% on average across all participants. For spectra recorded at high pass energies (≥90 eV), values of absolute offset and systematic deviation are ~5.8% and ±5.7%, respectively, whereas for spectra collected at lower pass energies (<90 eV), values of absolute offset and systematic deviation are ~4.9% and ±8.8%, respectively; low pass energy spectra perform worse than the global average, in terms of systematic deviations, due to diminished count rates and signal-to-noise ratio. Differences in absolute offset are attributed to the surface roughness of the LDPE induced by sample preparation. We further assess the usability of LDPE as a secondary reference material and comment on its performance in the presence of issues such as variable dark noise, x-ray warm up times, inaccuracy at low count rates, and underlying spectrometer problems. In response to participant feedback and the results of the study, we provide an updated LDPE intensity calibration protocol to address the issues highlighted in the interlaboratory study. Finally, we also comment on the lack of implementation of a consistent and traceable intensity calibration method across the community of x-ray photoelectron spectroscopy (XPS) users and, therefore, propose a route to achieving this with the assistance of instrument manufacturers, metrology laboratories, and experts leading to an international standard for XPS intensity scale calibration.

36 MATERIALS SCIENCE↗

Savings in Action: Lessons from Observed and Modeled Residential Solar Plus Storage Systems

The electric grid is rapidly evolving as small-scale, demand-side resources play increasingly important roles in grid operations and decarbonization. Maximizing the potential of demand-side resources involves incentivizing electricity customers to use those resources in ways that benefit the broader electrical grid. These incentives depend largely on the electricity cost savings that customers can realize from demand-side resource adoption. Determining these potential cost savings is a complex task. Cost savings depend on numerous factors, including the characteristics of different technologies, the algorithms that control these devices, system performance, customer behavior, electricity rate structures, and climatic factors. Another challenge is that estimated cost savings are frequently based on modeled rather than observed system performance, particularly in the academic literature. In this study, we begin to fill the gap in empirical research of demand-side resources using data from a new construction residential community equipped with rooftop solar and storage (S+S) in Arizona. We use these data to analyze the factors that determine customer electricity cost savings and emissions impacts of S+S in the real world. We then compare these data to modeled system performance to understand how models deviate from real-world outcomes. Based on these findings, we explore ways to improve such models and, conversely, use modeled results to suggest improvements to actual S+S deployment. The results of these analyses can be summarized in four key findings: 1) rate structures play a central role in the grid and customer value of demand-side resources; 2) certain customers can benefit more from demand-side resource adoption than others; 3) modeled battery dispatch and sizing reveals opportunities for additional cost savings; and 4) optimal dispatches can reduce grid emissions while maximizing bill savings.

14 SOLAR ENERGY↗

Nonuniformity in Mechanical Properties of Linear Friction Welded Mild Steel Joint

Mild steel was successfully joined by linear friction welding. Grain size at peripheral region was coarser than that at the other zones of the weld interface, which had no significant effect on microhardness. The local tensile properties were considerably decreased when oxides or lack of bonding appeared at the interface. Ductile fracture dominated the fracture mode for all joints. Variation in local tensile properties could be relieved under a medium friction pressure, a relatively high amplitude with a sufficient friction time. It was attributed to the facts that plastic metal layer of joint became uniform to some extent and interfacial defects were eliminated. The standard deviation of plastic metal layer thickness (χ{sub p}) could be used to describe the combined effects of welding parameters on joint integral performance. It was found that the standard deviation of plastic metal layer thickness showed a strong inverse correlation with the joint integral performance. Well-formed and defect-free joints exhibiting 90% of the base metal tensile strength could be produced when processing at a frequency of 20 Hz with a friction pressure of 103 MPa or 155 MPa, an amplitude of 2.5 mm and a friction time of at least 4 s.

36 MATERIALS SCIENCE↗

The study of the core–valence and core–core correlation effects on the radiative properties along the magnesium isoelectronic sequence

We investigated the effect of core–valence and core–core correlations on the energy levels and transition probabilities along the Mg isoelectronic sequence from Si{sup 2+} to U{sup 80+}. In order to attain a certain accuracy for the atomic structure we considered configurations obtained by electron promotions from the n=3 up to n=7 valence shells. Core–valence and core–core correlations are systematically included in the model by allowing single and double electron promotions from the n=2 core up to the n=6 and n=5 shells with l≤4 and l≤2, respectively. The present results contain the energy of the levels arising from the valence configurations along with oscillator strengths and radiative rates corresponding to E1, M1, E2, M2 transitions between states arising from 3l3l{sup ′} with l,l{sup ′}≤2 and 3snl{sup ′′} with n≤7 and l{sup ′′}≤4 configurations. We conclude the data accuracy trend along the magnesium isoelectronic sequence as a result of the detailed study of the correlation effects on the radiative properties. The core–valence correlations generally improve both energy and radiative rate values, while the core–core correlations mostly give better oscillator strengths but may slightly increase the energy deviations. The calculations have been performed by employing the fully relativistic model-potential Flexible Atomic Code.

74 ATOMIC AND MOLECULAR PHYSICS↗

Off-normal and failure condition analysis of the MITICA negative-ion accelerator

The negative-ion accelerator for the MITICA neutral beam injector has been designed and optimized in order to reduce the thermo-mechanical stresses in all components below limits compatible with the required fatigue life. However, deviation from the expected beam performances can be caused by “off-normal” operating conditions of the accelerator. The purpose of the present work is to identify and analyse all the “off-normal” operating conditions, which could possibly become critical in terms of thermo-mechanical stresses or of degradation of the optical performances of the beam.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improved Controller Design of Grid Friendly™ Appliances for Primary Frequency Response

The Grid Friendly$^\textrm{TM}$ Appliance~(GFA) controller, developed at Pacific Northwest National Laboratory, can autonomously switch off the appliances by detecting the under-frequency events. In this paper, the impacts of curtailing frequency threshold on the performance of frequency responsive GFAs are carefully analyzed first. The current method of selecting curtailing frequency thresholds for GFAs is found to be insufficient to guarantee the desired performance especially when the frequency deviation is shallow. In addition, the power reduction of online GFAs could be so excessive that it can even impact the system response negatively. As a remedy to the deficiency of the current controller design, a different way of selecting curtailing frequency thresholds is proposed to ensure the effectiveness of GFAs in frequency protection. Moreover, it is also proposed to introduce a supervisor at each distribution feeder to monitor the curtailing frequency thresholds of online GFAs and take corrective actions if necessary.

Lian, Jianming↗

WE-AB-204-06: Pseudo-CT Generation Using Undersampled, Single-Acquisition UTE-MDixon and Direct-Mapping Artificial Neural Networks for MR-Based Attenuation Correction and Radiation Therapy Planning

Purpose: Emerging technologies such as dedicated PET/MRI and MR-therapy systems require robust and clinically practical methods for determining photon attenuation. Herein, we propose using novel MR acquisition methods and processing for the generation of pseudo-CTs. Methods: A single acquisition, 190-second UTE-mDixon sequence with 25% (angular) sampling density and 3D radial readout was performed on nine volunteers. Three water-filled tubes were placed in the FOV for trajectory-delay correction. The MR data were reconstructed to generate three primitive images acquired at TEs of 0.1, 1.5 and 2.8 ms. In addition, three derived MR images were generated, i.e. two-point Dixon water/fat separation and R2* (1/T2*) map. Furthermore, two spatial features, i.e. local binary pattern (S-1) and relative spatial coordinates (S-2), were incorporated. A direct-mapping operator was generated using Artificial Neural Networks (ANNs) for transforming the MR features to a pseudo-CT. CT images served as the training data and, using a leave-one-out method, for performance evaluation using mean prediction deviation (MPD), mean absolute prediction deviation (MAPD), and correlation coefficient (R). Results: The errors between measured CT and pseudo-CT declined dramatically when the spatial features, i.e. S-1 and S-2, were included. The MPD, MAPD, and R were, respectively, 5±57 HU, 141±41 HU, and 0.815±0.066 for results generated by the ANN trained without the spatial features and were 32±26 HU, 115±18 HU, and 0.869±0.035 with the spatial features. The estimation errors of the pseudo-CT were smaller when both the S-1 and S-2 were used together than when either the S-1 or the S-2 was used. Pseudo-CT generation (256×256×256 voxels) by ANN took < 0.5 s using a computer having an Intel i7 3.4GHz CPU and 16 GB RAM. Conclusion: The proposed direct-mapping ANN approach is a technically accurate, clinically practical method for pseudo-CT generation and can potentially help improve the accuracy of MR-AC and MR-RTP applications. Please note that the project was completed with partial funding from the Ohio Department of Development grant TECH 11-063 and a sponsored research agreement with Philips Healthcare that is managed by Case Western Reserve University. As noted in the affiliations, some of the authors are Philips employees.

60 APPLIED LIFE SCIENCES↗

TU-FG-201-03: Automatic Pre-Delivery Verification Using Statistical Analysis of Consistencies in Treatment Plan Parameters by the Treatment Site and Modality

Purpose: A novel computer software system, namely APDV (Automatic Pre-Delivery Verification), has been developed for verifying patient treatment plan parameters right prior to treatment deliveries in order to automatically detect and prevent catastrophic errors. Methods: APDV is designed to continuously monitor new DICOM plan files on the TMS computer at the treatment console. When new plans to be delivered are detected, APDV checks the consistencies of plan parameters and high-level plan statistics using underlying rules and statistical properties based on given treatment site, technique and modality. These rules were quantitatively derived by retrospectively analyzing all the EBRT treatment plans of the past 8 years at authors’ institution. Therapists and physicists will be notified with a warning message displayed on the TMS computer if any critical errors are detected, and check results, confirmation, together with dismissal actions will be saved into database for further review. Results: APDV was implemented as a stand-alone program using C# to ensure required real time performance. Mean values and standard deviations were quantitatively derived for various plan parameters including MLC usage, MU/cGy radio, beam SSD, beam weighting, and the beam gantry angles (only for lateral targets) per treatment site, technique and modality. 2D-based rules of combined MU/cGy ratio and averaged SSD values were also derived using joint probabilities of confidence error ellipses. The statistics of these major treatment plan parameters quantitatively evaluate the consistency of any treatment plans which facilitates automatic APDV checking procedures. Conclusion: APDV could be useful in detecting and preventing catastrophic errors immediately before treatment deliveries. Future plan including automatic patient identify and patient setup checks after patient daily images are acquired by the machine and become available on the TMS computer. This project is supported by the Agency for Healthcare Research and Quality (AHRQ) under award 1R01HS0222888. The senior author received research grants from ViewRay Inc. and Varian Medical System.

60 APPLIED LIFE SCIENCES↗

A search for new physics in central exclusive production using the missing mass technique with the CMS detector and the CMS-TOTEM precision proton spectrometer

A generic search is presented for the associated production of a Z boson or a photon with an additional unspecified massive particle X, pp → pp + Z/γ + X, in proton-tagged events from proton–proton collisions at $\sqrt{s}$ = 13 TeV, recorded in 2017 with the CMS detector and the CMS-TOTEM precision proton spectrometer. The missing mass spectrum is analysed in the 600–1600 GeV range and a fit is performed to search for possible deviations from the background expectation. No significant excess in data with respect to the background predictions has been observed. Model-independent upper limits on the visible pro duction cross section of pp → pp + Z/γ + X are set

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Xenon implantation of nanodiamond films for targeted color center emission at sub-nanosecond time scales

In this work, the lifetime of nitrogen-vacancy color centers within nanodiamonds is reduced from 550±13 ps to 297±10 ps through the implantation of xenon. Coupled-mode analysis is employed to characterize the mechanism responsible for the reduction in emission lifetime. The observed spectral lineshape is found to be consistent with a Voigt profile consisting of two Lorentzian resonant peaks at 637 nm and 811 nm that are inhomogeneously broadened by a Gaussian distribution. A convolution of the frequency-domain Lorentzian output, with linewidths less than 1 nm, from the coupled-mode system of equations with a Gaussian with standard deviation of 85 nm is performed to generate the Voigt profile. The shortened emission lifetime is found to be consistent with a coupled mode theory model incorporating coupling between nitrogen-vacancy and xenon-vacancy color centers.

36 MATERIALS SCIENCE↗

SPND Sensitivity Calculations Using MCNP and Experimental Data from ACRR

The use of the Monte Carlo N-Particle Transport Code (MCNP) to calculate detector sensitivity for Self-Powered Neutron Detectors (SPNDs) in the Annular Core Research Reactor (ACRR) could be a vital tool in the effort to optimize the design of next-generation SPNDs. Next-generation SPND designs, which consider specific materials and geometry, may provide experimenters with capabilities for advanced mixed field dosimetry. These detectors will need to be optimized for configuration, materials, and geometries and the ability to model and iterate must be available in order to decide on the ideal. SPND design. SPNDs were modeled in MCNP which closely resembled the dimensions and location of actual detectors used in the ACRR. Tallies were used to calculate detector sensitivity. Using metrics from a previous report, oscilloscope data from pulses were manipulated in a Matrix Laboratory computing environment (MATLAB) script to calculate experimental detector sensitivity. This report outlines the process in which experimental data from ACRR pulses verified results from tallies in an MCNP ACRR model. The sensitivity values from experiments and MCNP calculations agreed within one standard deviation. Parametric studies were also performed with MCNP to investigate the effects of materials and dimensions of different SPNDs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗