Search NASA⌕ Search

SEARCH · Search NASA

Results for “Permeability Measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Acoustic velocity and permeability of acidized and propped fractures in shale

We report that from geochemical reactions to proppant emplacement, hydraulic fracturing induces various chemomechanical fracture alterations in shale reservoirs. Hydraulic fracturing through the injection of a vast amount and variety of fluids and proppants has substantial impacts on fluid flow and hydrocarbon production. There is a strong need to improve our understanding on how fracture alterations affect flow pathways within the stimulated rock volume and develop monitoring tools. We have conducted time-lapse rock-physics experiments on clay-rich (carbonate-poor) Marcellus shales to characterize the acoustic velocity and permeability responses to fracture acidizing and propping. Acoustic P- and S-wave velocities and fracture permeability were measured before and after laboratory-induced fracture alterations along with microstructural imaging through X-ray computed tomography and scanning electron microscopy. Our experiments indicate that the S-wave velocity is an important geophysical observable, particularly the S-wave polarized perpendicular to fractures because it is sensitive to fracture stiffness. The acidizing and propping of a fracture decrease its elastic stiffness. This effect is stronger for acidizing, so it is possible that proppant monitoring will be masked by chemical alteration except when propping is highly efficient (i.e., most fractures are propped). However, fracture permeability is undermined by the softening of fracture surfaces due to acidizing, while being greatly enhanced by propping. These contrasting effects on fluid flow in combination with similar seismic attributes indicate the importance of experiments to improve existing rock-physics models, which must include changes to the rock frame. Such improvements are necessary for a correct interpretation of seismic velocity monitoring of flow pathways in stimulated shales.

58 GEOSCIENCES↗

Synthesis of Alkoxy-TEMPO Aminoxyl Radicals and Electrochemical Characterization in Acetonitrile for Energy Storage Applications

In this paper, we describe the synthesis and characterization of alkoxylated TEMPO, (2,2,6,6-tetramethylpiperidin-1-yl)oxyl, radicals with potential application in organic non-aqueous redox flow batteries. The behavior of a series of TEMPO derivatives with varying lengths of alkoxy chain is analyzed in acetonitrile solutions using electrochemistry techniques, electron paramagnetic resonance (EPR) spectroscopy, and measurements of permeability through three different membranes. Electrochemical redox potentials are only weakly dependent on the substituent, but, in contrast, exchange current densities derived from the data do depend on the substitution. EPR lends further insight into these properties via the determination of hyperfine splitting constant and rotational correlation time. There is a negligible effect of the substituents on those parameters among the modified TEMPO radicals. Finally, permeation rates of modified TEMPO derivatives through membranes depend significantly on both the membrane and the substitution of TEMPO, providing insights into capacity fade measurements in the literature.

25 ENERGY STORAGE↗

Developing High-Throughput Organ-On-A-Chip Models to Investigate the Effects of Ionizing Radiation on the Central Nervous System

One of the main health risks in human space exploration is central nervous system (CNS) damage by ionizing radiation. Irradiation with simulated GCRs or their components, or high doses of low-LET radiation such as gamma rays, in animal models has been shown to cause neuronal damage together with glial cell activation and neuroinflammation and has been associated with prolonged cognitive and behavioral dysfunction. The extent of CNS damage in response to any insult, including ionizing radiation, is partially regulated by the blood-brain barrier (BBB), which enables immune cells to enter the CNS. The main cellular regulators of BBB permeability are astrocytes, which also modulate neuronal death, immune responses and oxidative stress, and thus could serve as a robust CNS-specific target for countermeasure development. However, studies on BBB permeability and astrocyte functions in regulating CNS responses to ionizing radiation have been limited, especially in human tissue/organ analogs. Therefore, we have established a high throughput 3D organ-on-a-chip system to study human CNS functions in response to ionizing radiation, with the eventual goal of adapting it to spaceflight missions. We utilized commercially available OrganoPlate system (Mimetas, Inc.) seeded with primary or induced pluripotent stem cell-derived human cells for developing 3D neuronal-astrocytic and BBB models. We investigated both immediate and delayed CNS dose responses to 0.5-1 Gy X-rays by measuring BBB permeability and morphology, and astrocyte activation. We have also quantified secreted markers of oxidative stress and cell viability. In the future, we are planning to monitor dendritic, axonal and synaptic changes in neurons, evaluate the combined exposures to simulated microgravity and ionizing radiation, and compare the responses to low and high-LET ionizing radiation. We anticipate these studies could indicate novel cellular and mechanistic targets for countermeasure developments to improve CNS functions in astronauts.

Malkani, Sherina↗

Integrated geological, economic, and risk assessment of underground hydrogen storage

Underground hydrogen storage (UHS) is a promising option to buffer variable renewable power and support the hydrogen economy. Yet this technology is early-stage, and key uncertainties remain about how coupled processes such as geochemical and geomechanical impacts affect long-term storage security. In this paper, we seek to integrate the results from a large, multi-scale research program to quantify core feasibility metrics and situate these studies within ongoing efforts. Through this work, we evaluate hydrogen recoverability during storage by assessing diffusive losses, losses to geochemical interactions and their subsequent impact on geomechanical properties, and losses to residual saturation during injection and withdrawal. Molecular and laboratory studies show that lithologic heterogeneity, pore geometry, and mineral surface chemistry govern hydrogen–rock interactions, controlling loss pathways. High-pressure coreflooding is used to estimate relative permeabilities and measure parameters needed for reservoir-scale sensitivity analyses. These core-scale experiments found early hydrogen breakthrough at low saturations driven by capillary and viscous fingering, which limits pore-space utilization at early times, while repeated injection and withdrawal cycles improve deliverability over time. Technoeconomic factors and purity requirements for end uses are also considered as part of our comprehensive feasibility analysis. Finally, we underscore the importance of geophysical monitoring and tailored injection strategies to maintain integrity and efficiency. Together, these results provide a quantitative foundation for safe, scalable deployment of UHS and highlight priorities for future integrated studies.

08 HYDROGEN↗

Strategies for mitigating residual magnetic field effect on pre-production PIP-II SSR2 cryomodule performance

This paper outlines the strategy aimed at mitigating the adverse effects of residual magnetic fields on the performance of pre-production SSR2 superconducting cavities within the context of the PIP-II project at Fermilab. Residual magnetic fields can significantly impact cavity performance, leading to reduced quality factor. To address this challenge, our strategy integrates various approaches including magnetic shielding, careful selection of materials, quality controls aimed at measuring magnetic permeability, magnetic hygiene to reduce residual magnetic field at the installation phase. Additionally, experimental studies are being planned to analyze the behavior of the cavities under different magnetic field conditions, and the effectiveness of advanced demagnetization procedures.

43 PARTICLE ACCELERATORS↗

High temperature permeameter for measuring magnetic properties

Instrument for measuring magnetic permeability of materials undergoing heat treatment as method for monitoring stress relief and tempering is described. Procedure is based on magnetic potentiometer principle with yoke compensating coils to cancel effects of reluctance of yoke and joint gaps. Instrument is heated with specimen being heat treated.

Barranger, J. P.↗

The non-Newtonian heat and mass transport of He 2 in porous media used for vapor-liquid phase separation

This investigation of vapor-liquid phase separation (VLPS) of He 2 is related to long-term storage of cryogenic liquid. The VLPS system utilizes porous plugs in order to generate thermomechanical (thermo-osmotic) force which in turn prevents liquid from flowing out of the cryo-vessel (e.g., Infrared Astronomical Satellite). An apparatus was built and VLPS data were collected for a 2 and a 10 micrometer sintered stainless steel plug and a 5 to 15 micrometer sintered bronze plug. The VLPS data obtained at high temperature were in the nonlinear turbulent regime. At low temperature, the Stokes regime was approached. A turbulent flow model was developed, which provides a phenomenological description of the VLPS data. According to the model, most of the phase separation data are in the turbulent regime. The model is based on concepts of the Gorter-Mellink transport involving the mutual friction known from the zero net mass flow (ZNMF) studies. The latter had to be modified to obtain agreement with the present experimental VLPS evidence. In contrast to the well-known ZNMF mode, the VLPS results require a geometry dependent constant (Gorter-Mellink constant). A theoretical interpretation of the phenomenological equation for the VLPS data obtained, is based on modelling of the dynamics of quantized vortices proposed by Vinen. In extending Vinen's model to the VLPS transport of He 2 in porous media, a correlation between the K*(GM) and K(p) was obtained which permits an interpretation of the present findings. As K(p) is crucial, various methods were introduced to measure the permeability of the porous media at low temperatures. Good agreement was found between the room temperature and the low temperature K(p)-value of the plugs.

Yuan, S. W. K.↗

Permeation of halide anions through phospholipid bilayers occurs by the solubility-diffusion mechanism

Two alternative mechanisms are frequently used to describe ionic permeation of lipid bilayers. In the first, ions partition into the hydrophobic phase and then diffuse across (the solubility-diffusion mechanism). The second mechanism assumes that ions traverse the bilayer through transient hydrophilic defects caused by thermal fluctuations (the pore mechanism). The theoretical predictions made by both models were tested for halide anions by measuring the permeability coefficients for chloride, bromide, and iodide as a function of bilayer thickness, ionic radius, and sign of charge. To vary the bilayer thickness systematically, liposomes were prepared from monounsaturated phosphatidylcholines (PC) with chain lengths between 16 and 24 carbon atoms. The fluorescent dye MQAE (N-(ethoxycarbonylmethyl)-6-methoxyquinolinium bromide) served as an indicator for halide concentration inside the liposomes and was used to follow the kinetics of halide flux across the bilayer membranes. The observed permeability coefficients ranged from 10(-9) to 10(-7) cm/s and increased as the bilayer thickness was reduced. Bromide was found to permeate approximately six times faster than chloride through bilayers of identical thickness, and iodide permeated three to four times faster than bromide. The dependence of the halide permeability coefficients on bilayer thickness and on ionic size were consistent with permeation of hydrated ions by a solubility-diffusion mechanism rather than through transient pores. Halide permeation therefore differs from that of a monovalent cation such as potassium, which has been accounted for by a combination of the two mechanisms depending on bilayer thickness.

NASA Discipline Exobiology↗

Encapsulation system for the immunoisolation of living cells

The present invention is drawn to a composition of matter comprising high viscosity sodium alginate, cellulose sulfate and a multi-component polycation. Additionally, the present invention provides methods for making capsules, measuring capsule permeability to immunologically-relevant proteins and treating disease in an animal using encapsulated cells. Over one thousand combinations of polyanions and polycations were examined as polymer candidates suitable for encapsulation of living cells and thirty-three pairs were effective. The combination of sodium alginate, cellulose sulfate, poly(methylene-co-guanidine) hydrochloride, calcium chloride, and sodium chloride produced the most desirable results. Pancreatic islets encapsulated in this multicomponent capsule demonstrated glucose-stimulated insulin secretion in vitro and reversed diabetes without stimulating immune reaction in mice. The capsule formulation and system of the present invention allows independent adjustments of capsule size, wall thickness, mechanical strength and permeability, and offers distinct advantages for immunoisolating cells.

Wang, Taylor G.↗

Measurement of Helium and Xenon Knudsen permeability in graphite IG-11

Here, understanding the flow and diffusion (transport) of gases through nuclear graphite is of interest in both the prismatic and pebble bed high-temperature gas reactors (HTGRs), for normal operation and under accident conditions, for example, as related to graphite oxidation. Both the laminar and turbulent gaseous transport are of interest. It has also been noted that nuclear graphite can have pore sizes that can possibly lead to non-continuum transport, as the pore size can be comparable to the gaseous mean free path. We report measurements and analyzes of experiments performed with IG-11 graphite in the pressure range of 10 Pa to 14,700 Pa, 293 K, using Helium, and research grade xenon (99.999%), respectively. These values are in fair agreement with those reported for different graphites and gases by other investigators, but are also higher by six orders of magnitude than those reported for Kr permeability in a developmental very low permeability graphite-HXT-90. Our measured ratio of the Helium and Xenon permeabilities is about 4, different from $\sqrt{\frac{m_{Xe}}{m_{He}}}$ ≈ 5.72 that corresponds to diffuse reflection at the graphite surface for both gases. Simple analysis indicates that the two gases have slightly different accommodation coefficients (about 25%) with the graphite surface. However, there could also be other reasons, such as experimental uncertainties or the need for a more detailed analysis.

36 MATERIALS SCIENCE↗

Permeability Testing of Impacted Composite Laminates for Use on Reusable Launch Vehicles

Since composite laminates are beginning to be identified for use in reusable launch vehicle propulsion systems, an understanding of their permeance is needed. A foreign object impact event can cause a localized area of permeability (leakage) in a polymer matrix composite, and it is the aim of this study to assess a method of quantifying permeability-after-impact results. A simple test apparatus is presented, and variables that could affect the measured values of permeability-after-impact were assessed. Once it was determined that valid numbers were being measured, a fiber/resin system was impacted at various impact levels and the resulting permeability measured, first with a leak check solution (qualitative) then using the new apparatus (quantitative). The results showed that as the impact level increased, so did the measured leakage. As the pressure to the specimen was increased, the leak rate was seen to increase in a nonlinear fashion for almost all the specimens tested.

Nettles, A. T.↗

Permeability Testing of Impacted Composite Laminates for Use on Reusable Launch Vehicles

Since composite laminates are beginning to be identified for use in reusable launch vehicle propulsion systems, an understanding of their permeance is needed. A foreign object impact event can cause a localized area of permeability (leakage) in a polymer matrix composite, and it is the aim of this study to assess a method of quantifying permeability-after-impact results. A simple test apparatus is presented, and variables that could affect the measured values of permeability-after-impact were assessed. Once it was determined that valid numbers were being measured, a fiber/resin system was impacted at various impact levels and the resulting permeability measured, first with a leak check solution (qualitative) then using the new apparatus (quantitative). The results showed that as the impact level increased, so did the measured leakage. As the pressure to the specimen was increased, the leak rate was seen to increase in a nonlinear fashion for almost all the specimens tested.

Nettles, Alan T.↗

Permeability After Impact Testing of Composite Laminates

Since composite laminates are beginning to be identified for use in reusable launch vehicle propulsion systems, an understanding of their permeance is needed. A foreign object impact event can cause a localized area of permeability (leakage) in a polymer matrix composite and it is the aim of this study to assess a method of quantifying permeability-after-impact results. A simple test apparatus is presented and variables that could affect the measured values of permeability-after-impact were assessed. Once it was determined that valid numbers were being measured, a fiber/resin system was impacted at various impact levels and the resulting permeability measured, first with a leak check solution (qualitative) then using the new apparatus (quantitative). The results showed that as the impact level increased, so did the measured leakage. As the pressure to the specimen was increased, the leak rate was seen to increase in a non-linear fashion for almost all of the specimens tested.

Nettles, A.T.↗

Permeability After Impact Testing of Composite Laminates

Since composite laminates are beginning to be identified for use in reusable launch vehicle propulsion systems, an understanding of their permeance is needed. A foreign object impact event can cause a localized area of permeability (leakage) in a polymer matrix composite and it is the aim of this study to assess a method of quantifying permeability-after-impact results. A simple test apparatus is presented and variables that could affect the measured values of permeability-after-impact were assessed. Once it was determined that valid numbers were being measured, a fiber/resin system was impacted at various impact levels and the resulting permeability measured, first with a leak check solution (qualitative) then using the new apparatus (quantitative). The results showed that as the impact level increased, so did the measured leakage. As the pressure to the specimen was increased, the leak rate was seen to increase in a non-linear fashion for almost all of the specimens tested.

Nettles, Alan T.↗

Permeability of a New Parachute Fabric – Measurements, Modeling, and Application

In response to a NASA request, Heathcoat Fabrics Limited has woven a new parachute fabric (Custom Design 1 G-60315-1800-Q01). This fabric was tested to obtain its permeability in air (i.e., flow-through volume of air per area per time) over a range of differential pressures from 0.146 to 25 psf (7 to 1197 Pa). The fabric met its specification permeability of 60 to 100 ft3/ft2/min (30.5 to 50.8 cm3/cm2/s) at the U.S. standard differential pressure of 0.5 inch of water (2.60 psf, 124 Pa). The permeability results were transformed into an effective porosity model for use in calculations related to the total porosity of parachutes. The tested fabric is being considered for use in parachutes for future missions to Mars. Calculations of drag coefficient were performed for two geometrically identical parachutes using either the new fabric or fabric woven to Parachute Industry Specification PIA-C-7020D Type I (Mars Science Laboratory Disk-Gap-Band parachute operating on Mars at a Mach number of 0.41). These calculations indicate essentially no difference in the drag coefficient between the two parachutes.

Cruz, Juan R.↗

3D Printing of Functional Hydrogel Devices for Screenings of Membrane Permeability and Selectivity

Developing a fundamental understanding of the effects of varying ligand chemistries on mass transport rates is key to designing membranes with solute-specific selectivity. While permeation cells offer a robust method to characterize membrane performance, they are limited to assessing a single membrane chemistry or salt solution per test. As a result, investigating the effects of varying ligand chemistries on membrane performance can be a tedious process, involving both the preparation of multiple samples and numerous, time-consuming permeation tests. This study uses digital light processing (DLP) 3D printing to fabricate a millifluidic flow-based permeation device made from a hydrogel active ester network that can be easily functionalized with ion-selective ligands. Without the need for bonding or assembly steps, ligands can be introduced and tested in the permeation device by simply injecting a small volume of a ligand solution. Various salt concentrations and molecular species can be cycled through a single device by switching the solution feeding into the salt reservoir, thereby reducing the number of samples needed for permeability and selectivity screenings. This research sets the groundwork for formulation development and postprocessing methods to 3D-print functional millifluidic devices capable of assessing solute selectivity in membranes and polymer adsorbents for aqueous separations. In this work, comparable salt permeability trends were observed with both 3D-printed devices and traditional assays. Devices were functionalized with an imidazole ligand to investigate salt permeability and selectivity of monovalent and divalent salts. Measurements showed increasing permeability for monovalent salts (NaCl) relative to divalent salts (MgCl 2 , CuCl 2 ) in functionalized membranes, with higher monovalent/divalent selectivity at increasing imidazole grafting densities. Here, the methods and findings described here represent a step toward developing higher-throughput methods with 3D-printed devices for screening the effects of ligand chemistry on mass transport rates in membrane materials.

36 MATERIALS SCIENCE↗