A Study to Analyze the Permeation of High Density Gases and Propellant Vapors Through Single Layer Teflon or Teflon Structure Materials and Laminations

This report contains the results of a fifteen month analytical and experimental study of the leakage rate of the pressurant gases (N2, He) and the propellant vapors (N2O4,N2H4) through bladder structures consisting of two layers of Teflon separated by a metallic foil diffusion barrier containing microscopic or larger holes. Results were obtained for the steady state leakage rate through circular holes and long rectangular openings in the barrier for arbitrary thicknesses of the two Teflon layers. The effect of hole shape and relative hole position on the leakage rate were studied. The transient problem was analyzed and it was shown that steady state calculations are adequate for estimating the leakage rate. A computer program entitled "Diffusion Analyzer Program" was developed to calculate the leakage rate, both transient and steady state. Finally, the analytical results were compared to experimentally determined values of the leakage rate through a model laminated bladder structure. The results of the analysis are in good agreement with experiment. The experimental effort (Part II of the Bladder Permeation Program) measured the solubility, diffusion coefficient and permeability of helium, nitrogen and nitrogen tetroxide vapor through Teflon TFE and FEP membranes. Data were obtained in the temperature range of 25 to 100 C at pressures ranging from near vacuum to about 20 atmospheres. Results of the experimental effort were compared with the limited data previously reported. As a verification to the applicability of results to actual bladder systems, counter diffusion tests were performed with a laminated sample containing aluminum foil with a selected group of holes.

Johnson, R. L.↗

A Novel Silicon Micromachined Integrated MCM Thermal Management System

This research concerned the development of a novel porous wick, fabricated totally out of silicon, using state-of-the-art MEMS technology. A comprehensive summary of results, as well as additional fabrication details, can be found in the following three documents located in the attached Appendices: A) Selected pages and excerpts from Year 2 progress report of the principal NASA Grant awarded from NASA Lewis Research Center, Grant Number NAG3-1706 entitled "A Novel Silicon Nficromachined Integrated MCM Thermal Management System" submitted to NASA LRC on 4/4/98. B) Selected viewgraphs from the joint NASA, TEES, and UC meeting held at the University of Cincinnati on April 24, 1998. C) Pre-print of the paper entitled "Coherent Macro Porous Silicon as a Wick Structure in an Integrated Nficrofluidic Two-Phase Cooling System" to be presented September 20-25, 1998 at the SPIE conference held in Santa Clara, Ca. To summarize,. nearly all of the proposed work was successfully accomplished (albeit a 3-month time extension was required), proving that micromachining can indeed be used to fabricate porous silicon wick structures with precise hole sizes and patterning control, thus permitting a substantial improvement in future wick designs. In addition, the appropriate range of thermal conductivities of the porous samples were theoretically predicted (see Appendix A). Although not part of the scope of work, the permeability of the test samples were measured (see results sections of Appendices B and C).

Kazmierczak, M. J.↗

Magnetism and the interior of the moon

During the time period 1961-1972 eleven magnetometers were sent to the moon. The results of lunar magnetometer data analysis are reviewed, with emphasis on the lunar interior. Magnetic fields have been measured on the lunar surface at the Apollo 12, 14, 15, and 16 landing sites. The remanent field values at these sites are given. Satellite and surface measurements show strong evidence that the lunar crust is magnetized over much of the lunar globe. The origin of the lunar remanent field is not yet satisfactorily understood; several source models are presented. Simultaneous data from the Apollo 12 lunar surface magnetometer and the Explorer 35 Ames magnetometer are used to construct a wholemoon hysteresis curve, from which the global lunar permeability is determined. Total iron abundance is calculated for two assumed compositional models of the lunar interior. Other lunar models with a small iron core and with a shallow iron-rich layer are also discussed in light of the measured global permeability.

Dyal, P.↗

Permeability of membranes to amino acids and modified amino acids: mechanisms involved in translocation

The amino acid permeability of membranes is of interest because they are one of the key solutes involved in cell function. Membrane permeability coefficients (P) for amino acid classes, including neutral, polar, hydrophobic, and charged species, have been measured and compared using a variety of techniques. Decreasing lipid chain length increased permeability slightly (5-fold), while variations in pH had only minor effects on the permeability coefficients of the amino acids tested in liposomes. Increasing the membrane surface charge increased the permeability of amino acids of the opposite charge, while increasing the cholesterol content decreased membrane permeability. The permeability coefficients for most amino acids tested were surprisingly similar to those previously measured for monovalent cations such as sodium and potassium (approximately 10(-12)-10(-13) cm s-1). This observation suggests that the permeation rates for the neutral, polar and charged amino acids are controlled by bilayer fluctuations and transient defects, rather than partition coefficients and Born energy barriers. Hydrophobic amino acids were 10(2) more permeable than the hydrophilic forms, reflecting their increased partition coefficient values. External pH had dramatic effects on the permeation rates for the modified amino acid lysine methyl ester in response to transmembrane pH gradients. It was established that lysine methyl ester and other modified short peptides permeate rapidly (P = 10(-2) cm s-1) as neutral (deprotonated) molecules. It was also shown that charge distributions dramatically alter permeation rates for modified di-peptides. These results may relate to the movement of peptides through membranes during protein translocation and to the origin of cellular membrane transport on the early Earth.

Review↗

Effects of Porous Gap Fillers on 30P30N Leading-Edge SlatNoise. Part I: Surface Pressure and Acoustics

The leading edge slat of a high-lift system is one of the main contributors to airframe noise during approach. In a previous experimental study, we assessed the performance of an impermeable slat gap filler as a passive flow control device to reduce the slat noise associated with a two-dimensional, three-element high-lift airfoil. The present paper, the first of two parts,represents a follow-on investigation to assess the relative efficacy of permeable gap fillers thatallow successively higher amounts of flow to pass through the gap. To evaluate the influence of this passive flow control device on the acoustics generated by the unsteady flow near the slat, experiments are conducted in an anechoic wind tunnel by mounting a gap filler to the slat element of the two-dimensional 30P30N high-lift configuration. Measurements are performed at a single geometric angle of attack (𝛼𝑘=8◦) and three different flow speeds that correspond to Reynolds numbers of𝑅𝑒𝑐=1.2𝑒6,1.5𝑒6, and1.71𝑒6, respectively. Steady surface pressure measurements are used to gauge the influence of the permeable gap filler treatments on the overall lift. The effect of each treatment on the radiated noise is analyzed via acoustic array measurements, followed by delay-and-sum beamforming to locate the slat noise sources and to provide the integrated acoustic spectra. The porous gap fillers are found to eliminate the narrowband peaks in the acoustic spectra and, also, to yield a 10 dB reduction in the broadband noise in comparison with the baseline case with no gap filler. The porous gap filler with thelowest permeability acts similar to the impermeable gap filler examined previously. However, the aerodynamics and noise reduction both degrade with increasing permeability. An accompanying abstract describes the particle image velocimetry measurements of the flowfield within the slat cove and on either side of the permeable gap f

slat noise↗

The permanent and induced magnetic dipole moment of the moon

Magnetic field observations with the Apollo 15 subsatellite have been used to deduce the components of both the permanent and induced lunar dipole moments in the orbital plane. The present permanent lunar magnetic dipole moment in the orbital plane is less than 1.3 times ten to the eighteenth power gauss-cu cm. Any uniformly magnetized near surface layer is therefore constrained to have a thickness-magnetization product less than 2.5 emu-cm per g. The induced moment opposes the external field, implying the existence of a substantial lunar ionosphere with a permeability between 0.63 and 0.85. Combining this with recent measures of the ratio of the relative field strength at the ALSEP and Explorer 35 magnetometers indicates that the global lunar permeability relative to the plasma in the geomagnetic tail lobes is between 1.008 and 1.03.

Russell, C. T.↗

Static structural tests of a 1.5-meter diameter fabric attached inflatable decelerator

Meridional tape forces, permeability, and change in model contours were measured on the aft half of a 1.5-m-diameter attached inflatable decelerator (AID). Inflation pressures up to 103 kN per square meter and external pressures of 0.14 to 102 kN per square meter were used. The results indicated that the model stresses were near the desired isotensoid condition. Future AID designs should consider both stiffness and strength of the meridional tapes to obtain the optimum division of load between tapes and fabric. Permeability of pressurized fabric structures is a few orders of magnitude higher than that obtained in the standard low-pressure test on material specimens.

Willis, C. M.↗

Biomechanics of the Optic Nerve Sheath in VIIP Syndrome

Long-duration space flight carries the risk of developing Visual Impairment and Intracranial Pressure (VIIP) syndrome, a spectrum of ophthalmic changes including posterior globe flattening, choroidal folds, distension of the optic nerve sheath (ONS), optic nerve kinking and potentially permanent degradation of visual function. The slow onset of VIIP, its chronic nature, and certain clinical features strongly suggest that biomechanical factors acting on the ONS play a role in VIIP. Here we measure several relevant ONS properties needed to model VIIP biomechanics. The ONS (meninges) of fresh porcine eyes (n7) was reflected, the nerve proper was truncated near the sclera, and the meninges were repositioned to create a hollow cylinder of meningeal connective tissue attached to the posterior sclera. The distal end was cannulated, sealed, and pressure clamped (mimicking cerebrospinal fluid [CSF] pressure), while the eye was also cannulated for independent control of intraocular pressure (IOP). The meninges were inflated (CSF pressure cycling 7-50 mmHg) while ONS outer diameter was imaged. In another set of experiments (n4), fluid permeation rate across the meninges was recorded by observing the drainage of an elevated fluid reservoir (30 mmHg) connected to the meninges. The ONS showed behavior typical of soft tissues: viscoelasticity, with hysteresis in early preconditioning cycles and repeatable behavior after 4 cycles, and nonlinear stiffening, particularly at CSF pressures 15 mmHg (Figure). Tangent moduli measured from the loading curve were 372 101, 1199 358, and 2050 379 kPa (mean SEM) at CSF pressures of 7, 15 and 30 mmHg, respectively. Flow rate measurements through the intact meninges at 30mmHg gave a permeability of 1.34 0.46 lmincm2mmHg (mean SEM). The ONS is a tough, strain-stiffening connective tissue that is surprisingly permeable. The latter observation suggests that there could be significant CSF drainage through the ONS into the orbit, likely important for CSF transport in the optic nerve. These experimental measurements, extended to human eyes, are informing computational models of the pathophysiology and biomechanics of the ONS in VIIP syndrome.

fluid shifts↗

Effects of Porous Gap Fillers on Leading-Edge Slat Noise of 30P30N. Part II: PIV Measurements

The leading edge slat of a high-lift system is one of the main contributors to the airframe noise during approach conditions. This paper, the second of two parts, continues our previous studies on the slat gap filler as a passive noise control device on the two-dimensional, 30P30N multielement airfoil. Whereas the earlier study was focused on the effects of an impermeable gap filler that completely blocks the flow through the gap, this follow-on assessment is devoted to permeable slat gap fillers that allow limited amounts of flow to pass through the gap. Part I of this two-part abstract described the aerodynamic and acoustic effects of the permeable gap fillers, as inferred from both the measurements of static and unsteady surface pressures and the microphone array data for the radiated noise. To understand the physical mechanism responsible for the noise reduction documented in Part I, as well as for the accompanying aerodynamic penalty due to the porous gap fillers, Particle Image Velocimetry (PIV) is used in this paper to measure the flow details in the slat-cove region of the 30P30N model. A single angle of attack (𝛼 = 5.5◦) and a chord based Reynolds number of 1.71𝑒6 are selected as the test conditions. The PIV results show that the slat flow features are significantly altered with the presence of the porous gap filler, resulting in a more stable slat-cove shear layer and, thus, reduced velocity fluctuations with a successive decrease in the permeability. The porous gap filler with the lowest permeability acts similar to the solid gap filler. However, flow separation is observed on the upper side of the porous interface, which leads to an aerodynamic performance penalty via a reduction in lift on the main wing.

slat noise↗

Lunar magnetic permeability studies and magnetometer sensitivity

A regression of quiet magnetic field components simultaneously measured by the two Explorer 35 magnetometers reveals uncertainties in effective sensitivity factors of up to a few percent in one or both of these instruments. Given this, the validity of previous lunar permeability studies based on Explorer 35/ALSEP regressions, wherein inferences are drawn from regression line slopes differing from unity by the order of one percent, is called into question. We emphasize the need to critically address the question of small deviations in magnetometer sensitivity factors from nominal values as a part of any two-magnetometer lunar permeability study.

King, J. H.↗

Optic Nerve Sheath Mechanics and Permeability in VIIP Syndrome

Long-duration space flight carries the risk of developing Visual Impairment and Intracranial Pressure (VIIP) syndrome, a spectrum of ophthalmic changes including posterior globe flattening, choroidal folds, distension of the optic nerve sheath (ONS), optic nerve kinking and potentially permanent degradation of visual function. The slow onset of VIIP, its chronic nature, and certain clinical features strongly suggest that biomechanical factors acting on the ONS play a role in VIIP. Here we measure several relevant ONS properties needed to model VIIP biomechanics. The ONS (meninges) of fresh porcine eyes (n7) was reflected, the nerve proper was truncated near the sclera, and the meninges were repositioned to create a hollow cylinder of meningeal connective tissue attached to the posterior sclera. The distal end was cannulated, sealed, and pressure clamped (mimicking cerebrospinal fluid [CSF] pressure), while the eye was also cannulated for independent control of intraocular pressure (IOP). The meninges were inflated (CSF pressure cycling 7-50 mmHg) while ONS outer diameter was imaged. In another set of experiments (n4), fluid permeation rate across the meninges was recorded by observing the drainage of an elevated fluid reservoir (30 mmHg) connected to the meninges. The ONS showed behavior typical of soft tissues: viscoelasticity, with hysteresis in early preconditioning cycles and repeatable behavior after 4 cycles, and nonlinear stiffening, particularly at CSF pressures 15 mmHg (Figure). Tangent moduli measured from the loading curve were 372 101, 1199 358, and 2050 379 kPa (mean SEM) at CSF pressures of 7, 15 and 30 mmHg, respectively. Flow rate measurements through the intact meninges at 30mmHg gave a permeability of 1.34 0.46 lmincm2mmHg (mean SEM). The ONS is a tough, strain-stiffening connective tissue that is surprisingly permeable. The latter observation suggests that there could be significant CSF drainage through the ONS into the orbit, likely important for CSF transport in the optic nerve. These experimental measurements, extended to human eyes, are informing computational models of the pathophysiology and biomechanics of the ONS in VIIP syndrome.

biomechanics↗

Metal Standards for Waveguide Characterization of Materials

Rectangular-waveguide inserts that are made of non-ferromagnetic metals and are sized and shaped to function as notch filters have been conceived as reference standards for use in the rectangular- waveguide method of characterizing materials with respect to such constitutive electromagnetic properties as permittivity and permeability. Such standards are needed for determining the accuracy of measurements used in the method, as described below. In this method, a specimen of a material to be characterized is cut to a prescribed size and shape and inserted in a rectangular- waveguide test fixture, wherein the specimen is irradiated with a known source signal and detectors are used to measure the signals reflected by, and transmitted through, the specimen. Scattering parameters [also known as "S" parameters (S11, S12, S21, and S22)] are computed from ratios between the transmitted and reflected signals and the source signal. Then the permeability and permittivity of the specimen material are derived from the scattering parameters. Theoretically, the technique for calculating the permeability and permittivity from the scattering parameters is exact, but the accuracy of the results depends on the accuracy of the measurements from which the scattering parameters are obtained. To determine whether the measurements are accurate, it is necessary to perform comparable measurements on reference standards, which are essentially specimens that have known scattering parameters. To be most useful, reference standards should provide the full range of scattering-parameter values that can be obtained from material specimens. Specifically, measurements of the backscattering parameter (S11) from no reflection to total reflection and of the forward-transmission parameter (S21) from no transmission to total transmission are needed. A reference standard that functions as a notch (band-stop) filter can satisfy this need because as the signal frequency is varied across the frequency range for which the filter is designed, the scattering parameters vary over the ranges of values between the extremes of total reflection and total transmission. A notch-filter reference standard in the form of a rectangular-waveguide insert that has a size and shape similar to that of a material specimen is advantageous because the measurement configuration used for the reference standard can be the same as that for a material specimen. Typically a specimen is a block of material that fills a waveguide cross-section but occupies only a small fraction of the length of the waveguide. A reference standard of the present type (see figure) is a metal block that fills part of a waveguide cross section and contains a slot, the long dimension of which can be chosen to tailor the notch frequency to a desired value. The scattering parameters and notch frequency can be estimated with high accuracy by use of commercially available electromagnetic-field-simulating software. The block can be fabricated to the requisite precision by wire electrical-discharge machining. In use, the accuracy of measurements is determined by comparison of (1) the scattering parameters calculated from the measurements with (2) the scattering parameters calculated by the aforementioned software.

Lambert, Kevin M.↗

Lunar surface magnetometer experiment

The Apollo 15 lunar-surface magnetometer (LSM) is one of a network of magnetometers that have been deployed on the moon to study intrinsic remanent magnetic fields and global magnetic response of the moon to large-scale solar and terrestrial magnetic fields. From these field measurements, properties of the lunar interior such as magnetic permeability, electrical conductivity, and temperature can be calculated. In addition, correlation with solar-wind-spectrometer data allows study of the the solar-wind plasma interaction with the moon and, in turn, investigation of the resulting absorption of gases and accretion of an ionosphere. These physical parameters and processes determined from magnetometer measurements must be accounted for by comprehensive theories of origin and evolution of the moon and solar system.

Dyal, P.↗

VARTM Process Modeling of Aerospace Composite Structures

A three-dimensional model was developed to simulate the VARTM composite manufacturing process. The model considers the two important mechanisms that occur during the process: resin flow, and compaction and relaxation of the preform. The model was used to simulate infiltration of a carbon preform with an epoxy resin by the VARTM process. The model predicted flow patterns and preform thickness changes agreed qualitatively with the measured values. However, the predicted total infiltration times were much longer than measured most likely due to the inaccurate preform permeability values used in the simulation.

Song, Xiao-Lan↗

Stress Analysis and Permeability Testing of Cryogenic Composite Feed Line

For the next generation Single-Stage-To-Orbit (SSTO) Reusable Launch Vehicle (RLV), the use of advanced composite materials is highly desirable and critical to the success of the mission. NASA Marshall Space Flight Center (MSFC) has been working with the aerospace industry for many years to develop and demonstrate the cryogenic composite propellant tanks and feed lines technologies. A 50.8-mm diameter composite feed line for the Clipper Graham (DCY.A) was developed and tested. The purpose of the program is to demonstrate the LH2 permeability, composite to composite and metal joints, as well as composite flange interface of the composite feed line. Stress analysis and permeability testing have been performed on this article. Recently, a larger composite feed line design is being investigated and developed at MSFC for potential use in future RLV. The diameter of the feed line is 203 mm and the overall length is approximately 2.2 meters. This one piece unlined feed line consists of three straight tubular sections joined by two 90 degree elbows. The material chosen is IM7/977-3 prepreg fabric. The lay-up pattern is [0/90, plus or minus 45]s and is built up to 18 plies to the flanges at both ends. A preliminary stress analysis has been conducted to identify potential critical stresses and to develop the finite element analysis (FEA) capability of composite feed lines. As expected, the critical stresses occurred at the rims of some flange holes and the onset of the tapered tubular sections. Further analysis is required to determine the loads, flange deflection, vibration, and combined maximum loads. Two permeability-testing apparatuses were also designed for both flat panel specimens and curved feed line sections after impact damage. A larger permeant gas exposed area is required to accurately determine the effect of impact damage on the permeability of the feed line materials. The flat panel tester was fabricated and assembled. Three test coupons were made of graphite/epoxy plain weave prepreg and unidirectional prepreg. The flow rate was calculated by measuring the change of manometer fluid height per unit time. The permeability of the coupons is then calculated according to Darcy's Law. The pressure increase due to the head rise in the manometer was not considered for the initial estimation. The result of the unidirectional composite coupon agreed with that obtained from the DC-XA feed line testing of a similar material. Further improvement on the design may be required to improve the accuracy and efficiency of permeability testing.

Chu, Tsuchin Philip↗

A proposed magnetic digital temperature transducer, volume 1

A study has been made of the feasibility of using the discontinuous permeability versus temperature characteristics of some magnetic materials for a digital temperature transducer and a thermally controlled ON-OFF switch. Simple logic converts the number of output pulse to a digital word recognizable by the system. Efforts have been concentrated on materials with Curie temperatures between 0 and 100 C. One compound has the composition Mn(5-x)Fe(x)Ge3 where the amount of iron determines the transition temperature. The other compound is Ni-Zn ferrite and has the compositon Ni(1-x)Zn(x)Fe(1.95)O4 where the nickel: zinc ratio determines the transition temperature. A detailed report of materials prepared is presented. Toroidal inductors of the material have been constructed and the change in inductance with temperature measured. In view of these initial measurements, it is felt that a transducer utilizing the permeability versus temperature characteristics of these materials has promise as a reliable and sensitive solid state digital temperature transducer.

Collier, T. E.↗