Search NASA⌕ Search

SEARCH · Search NASA

Results for “Phonon detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Toward a DM Search with Phonon-Mediated MKID Devices at NEXUS

To continue the search for dark matter (DM) into the sub-GeV mass range, the development and characterization of new detectors with sub-eV thresholds is critical. Microwave Kinetic Inductance Detectors (MKIDs) offer an attractive architecture for novel microcalorimeters with the requisite energy resolution and threshold for probing DM down to the fermionic thermal relic mass limit of a few keV. A phonon-sensitive MKID device featuring an aluminum resonator patterned onto a silicon substrate has been operating at the NEXUS low-background facility at Fermilab for characterization and evaluation of its efficacy for a dark matter search. Currently, our estimate of the energy resolution of this device is limited by the efficiency for phonons produced via particle interactions in the substrate to propagate to the superconductor and break Cooper pairs. In this poster, I will present our constraints on the substrate-superconductor coupling and the progress on an absolute energy calibration performed by exposing the rear of the substrate to a pulsed source of 470 nm photons. I will also review the current status and next steps of the phonon-mediated MKID effort at Fermilab.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Twelve-crystal prototype of Li 2 MoO 4 scintillating bolometers for CUPID and CROSS experiments

An array of twelve 0.28 kg lithium molybdate (LMO) low-temperature bolometers equipped with 16 bolometric Ge light detectors, aiming at optimization of detector structure for CROSS and CUPID double-beta decay experiments, was constructed and tested in a low-background pulse-tube-based cryostat at the Canfranc underground laboratory in Spain. Performance of the scintillating bolometers was studied depending on the size of phonon NTD-Ge sensors glued to both LMO and Ge absorbers, shape of the Ge light detectors (circular vs. square, from two suppliers), in different light collection conditions (with and without reflector, with aluminum coated LMO crystal surface). The scintillating bolometer array was operated over 8 months in the low-background conditions that allowed to probe a very low, μBq/kg, level of the LMO crystals radioactive contamination by 228 Th and 226 Ra.

47 OTHER INSTRUMENTATION↗

Sub-Kelvin High-Mass CCD Detectors for Dark Matter & Neutrino Searches (Technical Report)

This project aims to achieve two synergistic goals: 1) Develop a high mass low temperature CCD detector to measure charge transfer efficiency at sub-kelvin temperatures. 2) Use alternating surface bias at low voltages to produce NL phonons at the same rate as CDMS HV but without the need for HV bias. This will allow for a non-invasive NL amplification and paves the way for future single electron resolution large mass DM or CE NS detectors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Electrical NEP in Hot-Electron Titanium Superconducting Bolometers

We are presenting the current progress on the titanium (Ti) hot-electron transition-edge devices. The ultimate goal of this work is to develop a submillimeter Hot-Electron Direct Detector (HEDD) with the noise equivalent power NEP = 10(sup -1) - 10(sup -20) W/Hz(sup 1/2) for the moderate resolution spectroscopy and Cosmic Microwave Background (CMB) studies on future space telescope (e.g., SPICA, SAFIR, SPECS, CMBPol) with cryogenically cooled (approximately 4-5 K) mirrors. Recently, we have achieved the extremely low thermal conductance (approximately 20 fW/K at 300 mK and approximately 0.1 fW/K at 40 mK) due to the electron-phonon decoupling in Ti nanodevices with niobium (Nb) Andreev contacts. This thermal conductance translates into the "phonon-noise" NEP approximately equal to 3 x 10(sup -21) W/Hz(sup 1/2) at 40 mK and NEP approximately equal to 3 x 10(sup -19) W/Hz(sup 1/2) at 300 mK. These record data indicate the great potential of the hot-electron detector for meeting many application needs. Beside the extremely low phonon-noise NEP, the nanobolometers have a very low electron heat capacitance that makes them promising as detectors of single THz photons. As the next step towards the practical demonstration of the HEDD, we fabricated and tested somewhat larger than in Ref.1 devices (approximately 6 micrometers x 0.35 micrometers x 40 nm) whose critical temperature is well reproduced in the range 300-350 mK. The output electrical noise measured in these devices with a low-noise dc SQUID is dominated by the thermal energy fluctuations (ETF) aka "phonon noise". This indicates the high electrothermal loop gain that effectively suppresses the contributions of the Johnson noise and the amplifier (SQUID) noise. The electrical NEP = 6.7 x 10(sup -18) W/Hz(sup 1/2) derived from these measurements is in good agreement with the predictions based on the thermal conductance data. The very low NEP and the high speed (approximately microns) are a unique combination not found in other detectors.

transition-edge sensor↗

Probing nanoparticle substrate interactions with synchrotron infrared nanospectroscopy: Coupling gold nanorod Fabry-Pérot resonances with SiO 2 and $h$-BN phonons

Spectroscopic interrogation of materials in the midinfrared with nanometer spatial resolution is inherently difficult due to the long wavelengths involved, reduced detector efficiencies, and limited availability of spectrally bright, coherent light sources. Technological advances are driving techniques that overcome these challenges, enabling material characterization in this relatively unexplored spectral regime. Synchrotron infrared nanospectroscopy (SINS) is an imaging technique that provides local sample information of nanoscale target specimens in an experimental energy window between 330 and 5000 cm -1 . Here, using SINS, we analyzed a series of individual gold nanorods patterned on a SiO 2 substrate and on a flake of hexagonal boron nitride. The SINS spectra reveal interactions between the nanorod photonic Fabry-Pérot resonances and the surface phonon polaritons of each substrate, which are characterized as avoided crossings. A coupled oscillator model of the hybrid system provides a deeper understanding of the coupling and provides a theoretical framework for future exploration.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Tunable superlattice p-i-n photodetectors: Characteristics, theory, and applications

Extended measurements and theory on the recently developed monolithic wavelength demultiplexer consisting of voltage-tunable superlattice p-i-n photodetectors in a waveguide configuration are discussed. It is shown that the device is able to demultiplex and detect two optical signals with a wavelength separation of 20 nm directly into different electrical channels at a data rate of 1 Gb/s and with a crosstalk attenuation varying between 20 and 28 dB, depending on the polarization. The minimum acceptable crosstalk attenuation at a data rate of 100 Mb/s is determined to be 10 dB. The feasibility of using the device as a polarization angle sensor for linearly polarized light is also demonstrated. A theory for the emission of photogenerated carriers out of the quantum wells is included, since this is potentially a speed limiting mechanism in these detectors. It is shown that a theory of thermally assisted tunneling by polar optical phonon interaction is able to predict emission times consistent with the observed temporal response.

Larsson, Anders↗

Athermal Energy Loss from X-rays Deposited in Thin Superconducting Films on Solid Substrates

When energy is deposited in a thin-film cryogenic detector, such as from the absorption of an X-ray, an important feature that determines the energy resolution is the amount of athermal energy that can be lost to the heat bath prior to the elementary excitation systems coming into thermal equilibrium. This form of energy loss will be position-dependent and therefore can limit the detector energy resolution. An understanding of the physical processes that occur when elementary excitations are generated in metal films on dielectric substrates is important for the design and optimization of a number of different types of low temperature detector. We have measured the total energy loss in one relatively simple geometry that allows us to study these processes and compare measurements with calculation based upon a model for the various di.erent processes. We have modeled the athermal phonon energy loss in this device by finding an evolving phonon distribution function that solves the system of kinetic equations for the interacting system of electrons and phonons. Using measurements of device parameters such as the Debye energy and the thermal di.usivity we have calculated the expected energy loss from this detector geometry, and also the position-dependent variation of this loss. We have also calculated the predicted impact on measured spectral line-shapes, and shown that they agree well with measurements. In addition, we have tested this model by using it to predict the performance of a number of other types of detector with di.erent geometries, where good agreement is also found.

Kozorezov, Alexander G.↗

Measurement of a high electrical quality factor in a niobium resonator for a gravitational radiation detector

The mechanical and electrical quality factors of a 10-g niobium resonator were measured at 4.4 K and were found to be 8.1 x 10 to the 6th, and 3.8 x 10 to the 6th, respectively. The value for the electrical quality factor is high enough for a system operating at 50 mK at a sensitivity level of one phonon. The resonator's low damping properties make it suitable for use as a transducer for a cryogenic three-mode gravitational radiation detector. A practical design is given for the mounting of the resonator on a 2400-kg aluminum-bar detector. Projections are made for the sensitivity of a 2400-kg bar instrumented as a three-mode system with this resonator inductively coupled to a SQUID.

Folkner, W. M.↗

SuperCDMS Event Reconstruction Using Convolutional Neural Networks [Thesis]

The SuperCDMS experiment uses cryogenic silicon and germanium detectors to search for dark matter candidates such as WIMPs (Weakly Interacting Massive Particles) streaming through the Earth. Collisions in the silicon and germanium crystals are expected to produce phonons whose thermal signatures can be measured. This thesis first describes the integration of a new Signal Distribution Unit (SDU) to the SuperCDMS data acquisition system, which allows for synchronization of multiple detectors and electronic/mechanical noise characterization via accelerometer, antenna, and AC phase measurements. From SuperCDMS detector data it is necessary to reconstruct the energies of the particle events. This thesis explores the use of Convolutional Neural Networks (CNNs) to perform this reconstruction and finds that, although they perform well, changing the noise model breaks the model and requires the neural network to be retrained. In order to mitigate this issue, a new CNN model is proposed which includes the noise Power Spectral Density (PSD) of the data as an additional input to the CNN. While it proves to be effective as a denoising algorithm, it still fails for data with a different noise model. However, including data from multiple PSDs in the neural network training sample allows it to handle data with different types of noise while still maintaining the quality of the reconstruction. Nevertheless, neural networks trained even on multiple PSDs do not robustly handle data taken with PSDs dissimilar to those in the training sample, suggesting that CNNs may need to be retrained whenever the noise environment changes in a significant way.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advances toward high spectral resolution quantum X-ray calorimetry

Thermal detectors for X-ray spectroscopy combining high spectral resolution and quantum efficiency have been developed. These microcalorimeters measure the energy released in the absorption of a single photon by sensing the rise in temperature of a small absorbing structure. The ultimate energy resolution of such a device is limited by the thermodynamic power fluctuations in the thermal link between the calorimeter and isothermal bath and can in principle be made as low as 1 eV. The performance of a real device is degraded due to noise contributions such as excess 1/f noise in the thermistor and incomplete conversion of energy into phonons. The authors report some recent advances in thermometry, X-ray absorption and thermalization, fabrication techniques, and detector optimization in the presence of noise. These improvements have resulted in a device with a spectral resolution of 17 eV FWHM, measured at 6 keV.

Moseley, S. H.↗

Spin-phonon coupling in AFM transition-metal mono-oxide

Time-of-flight INS measurements were performed on single crystal NiO with the Wide Angular Range Chopper Spectrometer (ARCS) at the Spallation Neutron Source. Experiments were performed on NiO single crystal mounted in an aluminum can and cooled using a closed-cycle helium refrigerator. Measurements were conducted at T = 100 K and 650 K, with the [HHL] scattering plane aligned horizontally. A Fermi chopper with slit spacing of 1.52mm, spinning at 300 Hz, was used to select an incident neutron energy of 100 meV. All datasets were normalized to a vanadium standard to correct for detector efficiency and solid angle coverage. The data sets include the .nxs files, the generated .hdf5 files (for use with Phonon Explorer), and Python scripts used to create them.

36 MATERIALS SCIENCE↗

Distributed Antenna-Coupled TES for FIR Detectors Arrays

We describe a new architecture for a superconducting detector for the submillimeter and far-infrared. This detector uses a distributed hot-electron transition edge sensor (TES) to collect the power from a focal-plane-filling slot antenna array. The sensors lay directly across the slots of the antenna and match the antenna impedance of about 30 ohms. Each pixel contains many sensors that are wired in parallel as a single distributed TES, which results in a low impedance that readily matches to a multiplexed SQUID readout These detectors are inherently polarization sensitive, with very low cross-polarization response, but can also be configured to sum both polarizations. The dual-polarization design can have a bandwidth of 50The use of electron-phonon decoupling eliminates the need for micro-machining, making the focal plane much easier to fabricate than with absorber-coupled, mechanically isolated pixels. We discuss applications of these detectors and a hybridization scheme compatible with arrays of tens of thousands of pixels.

antenna↗

Directional detection of dark matter using solid-state quantum sensing

Next-generation dark matter (DM) detectors searching for weakly interacting massive particles (WIMPs) will be sensitive to coherent scattering from solar neutrinos, demanding an efficient background-signal discrimination tool. Directional detectors improve sensitivity to WIMP DM despite the irreducible neutrino background. Wide-bandgap semiconductors offer a path to directional detection in a high-density target material. A detector of this type operates in a hybrid mode. Here, the WIMP or neutrino-induced nuclear recoil is detected using real-time charge, phonon, or photon collection. The directional signal, however, is imprinted as a durable sub-micron damage track in the lattice structure. This directional signal can be read out by a variety of atomic physics techniques, from point defect quantum sensing to x-ray microscopy. In this Review, we present the detector principle as well as the status of the experimental techniques required for directional readout of nuclear recoil tracks. Specifically, we focus on diamond as a target material; it is both a leading platform for emerging quantum technologies and a promising component of next-generation semiconductor electronics. Based on the development and demonstration of directional readout in diamond over the next decade, a future WIMP detector will leverage or motivate advances in multiple disciplines toward precision dark matter and neutrino physics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Heat Capacity and Thermal Conductance Measurements of a Superconducting-Normal Mixed State by Detection of Single 3 eV Photons in a Magnetic Penetration Thermometer

We report on measurements of the detected signal pulses in a molybdenum-gold Magnetic Penetration Thermometer (MPT) in response to absorption of one or more 3 eV photons. We designed and used this MPT sensor for x-ray microcalorimetry. In this device, the diamagnetic response of a superconducting MoAu bilayer is used to sense temperature changes in response to absorbed photons, and responsivity is enhanced by a Meissner transition in which the magnetic flux penetrating the sensor changes rapidly to minimize free energy in a mixed superconducting normal state. We have previously reported on use of our MPT to study a thermal phonon energy loss to the substrate when absorbing x-rays. We now describe results of extracting heat capacity C and thermal conductance G values from pulse height and decay time of MPT pulses generated by 3 eV photons. The variation in C and G at temperatures near the Meissner transition temperature (set by an internal magnetic bias field) allow us to probe the behavior in superconducting normal mixed state of the condensation energy and the electron cooling power resulting from quasi-particle recombination and phonon emission. The information gained on electron cooling power is also relevant to the operation of other superconducting detectors, such as Microwave Kinetic Inductance Detectors.

superconductivity↗

Diamond and SiC Detectors for Rare Event Searches

In recent years, there has been increasing interest in developing detectors which are sensitive to sub-GeV dark matter and low-energy events from coherent neutrino scattering. Due to carbon’s light atomic weight and its tendency to form crystals with high-energy, long-lived phonon modes, carbon-based crystals (including diamond and silicon carbide (SiC)) present themselves as natural target materials for scattering-based searches in this regime. Here, we present our preliminary results in adapting our TES-based detectors to these substrates, specifically 4-H SiC and polycrystalline diamond. We focus on our fabrication efforts, specifically tuning the transition temperature (T C ) of tungsten films sputtered on these materials, as well as our advancement toward fabricating and testing devices on these substrates.

47 OTHER INSTRUMENTATION↗

Sapphire substrate qubit-based detector for light dark matter search

Harnessing sub-eV energy excitations from light dark matter interaction with a target material is one of the challenges in exploring promising novel materials for dark matter searches. In polar materials like sapphire, dark matter interaction can excite sub-eV optical phonon modes. Furthermore, the anisotropy of sapphire crystal could provide a signature of daily modulation of the dark matter scattering rate, making it a promising target material. We plan to utilize superconducting qubits on a sapphire substrate to take advantage of the excitation of phonons, which scatter and further down-convert to lower-energy phonons. A good fraction of these phonons are expected to reach the qubit superconductor on the substrate and break Cooper pairs. Such a process can cause qubit decoherence, which can be measured using standard qubit readout protocol. In this talk, we describe our ongoing attempt to build such a prototype detector.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

An Ultrasensitive Hot-Electron Bolometer for Low-Background SMM Applications

We are developing a hot-electron superconducting transition-edge sensor (TES) that is capable of counting THz photons and operates at T = 0.3K. The main driver for this work is moderate resolution spectroscopy (R approx. 1000) on the future space telescopes with cryogenically cooled (approx. 4 K) mirrors. The detectors for these telescopes must be background-limited with a noise equivalent power (NEP) approx. 10(exp -19)-10(exp -20) W/Hz(sup 1/2) over the range v = 0.3-10 THz. Above about 1 THz, the background photon arrival rate is expected to be approx. 10-100/s), and photon counting detectors may be preferable to an integrating type. We fabricated superconducting Ti nanosensors with a volume of approx. 3x10(exp -3) cubic microns on planar substrate and have measured the thermal conductance G to the thermal bath. A very low G = 4x10(exp -14) W/K, measured at 0.3 K, is due to the weak electron-phonon coupling in the material and the thermal isolation provided by superconducting Nb contacts. This low G corresponds to NEP(0.3K) = 3x10(exp -19) W/Hz(sup 1/2). This Hot-Electron Direct Detector (HEDD) is expected to have a sufficient energy resolution for detecting individual photons with v > 0.3 THz at 0.3 K. With the sensor time constant of a few microseconds, the dynamic range is approx. 50 dB.

bolometers↗