Search NASA⌕ Search

SEARCH · Search NASA

Results for “Physics, Optics and optical instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

High-resolution inelastic x-ray scattering at the high energy density scientific instrument at the European X-Ray Free-Electron Laser

We introduce a setup to measure high-resolution inelastic x-ray scattering at the High Energy Density scientific instrument at the European X-Ray Free-Electron Laser (XFEL). The setup uses the Si (533) reflection in a channel-cut monochromator and three spherical diced analyzer crystals in near-backscattering geometry to reach a high spectral resolution. An energy resolution of 44 meV is demonstrated for the experimental setup, close to the theoretically achievable minimum resolution. The analyzer crystals and detector are mounted on a curved-rail system, allowing quick and reliable changes in scattering angle without breaking vacuum. The entire setup is designed for operation at 10 Hz, the same repetition rate as the high-power lasers available at the instrument and the fundamental repetition rate of the European XFEL. Among other measurements, it is envisioned that this setup will allow studies of the dynamics of highly transient laser generated states of matter.

47 OTHER INSTRUMENTATION↗

Phase segregation and miscibility of TiO x nanocomposites in Gd-doped ceria solid electrolyte material

Electro-chemo-mechanical (ECM) coupling refers to mechanical deformation due to electrochemically driven compositional change in a solid. An ECM actuator producing micrometre-size displacements and long-term stability at room temperature was recently reported, comprising a 20 mol% Gd-doped ceria (20GDC), a solid electrolyte membrane, placed between two working bodies made of TiO x /20GDC (Ti-GDC) nanocomposites with Ti concentration of 38 mol%. The volumetric changes originating from oxidation or reduction in the local TiO x units are hypothesized to be the origin of mechanical deformation in the ECM actuator. Studying the Ti concentration-dependent structural changes in the Ti-GDC nanocomposites is therefore required for (i) understanding the mechanism of dimensional changes in the ECM actuator and (ii) maximizing the ECM response. Here, the systematic investigation of the local structure of the Ti and Ce ions in Ti-GDC over a broad range of Ti concentrations using synchrotron X-ray absorption spectroscopy and X-ray diffraction is reported. The main finding is that, depending on the Ti concentration, Ti atoms either form a cerium titanate or segregate into a TiO 2 anatase-like phase. The transition region between these two regimes with Ti(IV) concentration between 19% and 57% contained strongly disordered TiO x units dispersed in 20GDC containing Ce(III) and Ce(IV) and hence rich with oxygen vacancies. As a result, this transition region is proposed to be the most advantageous for developing ECM-active materials.

47 OTHER INSTRUMENTATION↗

Earth Scanner Bearing Accelerated Life Test

The Moderate Resolution Imaging Spectrometer (MODIS) optical instrument for NASA Goddard will measure biological and physical processes on the Earth's surface and in the lower atmosphere. A key component of the instrument is an extremely accurate scan mirror motor/encoder assembly. Of prime concern in the performance and reliability of the scan motor/encoder is bearing selection and lubrication. This paper describes life testing of the bearings and lubrication selected for the program.

Brian J Dietz↗

Position-Dependent Neutron Time-of-Flight Deviation at VULCAN Diffractometer

In neutron diffraction, it is critical to precisely measure the lattice spacing, as it is an indicator of a material’s physical characteristics, such as lattice strain, thermal expansion, and phase structures. In time-of-flight (TOF) measurements, the lattice spacing is determined by the recorded TOF from a well-calibrated instrument. However, changes in neutron time-of-flight are sensitive to many factors, such as the alignment of instrument optics, temperature, sample positions, sample dimensions, internal strains, and chemical or physical heterogeneities at the grain level. At VULCAN (SNS, ORNL), which is a high-flux engineering neutron diffractometer, we used a 1-mm-diameter diamond powder sample to scan for changes in TOF by measuring d-spacing values at different sample positions under several configurations. The 2D map of the TOF deviation or d-spacing deviation, in terms of lattice shift/lattice strain, is reported. The change in TOF is dependent on the scanned location in the beam as well as on detector locations. The results are informative for experimental planning, data interpretation, and future instrument design.

36 MATERIALS SCIENCE↗

Cassini/Huygens Science Instruments, Spacecraft, and Mission

The Cassini spacecraft will take 18 scientific instruments to Saturn. After launch and a seven-year cruise, Cassini will arrive at Saturn and separate into a Saturn orbiter and an atmospheric probe, called Huygens, which will descend to the surface of Titan. The orbiter will orbit the planet for four years, making close flybys of five satellites, including multiple flybys of Titan. Communication with Earth is at X-band; the maximum downlink rate from Saturn is 166 x 10(exp 3) bps. Orbiter instruments are body mounted; the spacecraft must be turned to point some of them toward objects of interest. The orbiter carries 12 instruments. Optical instruments provide imagery and spectrometry. Radar supplies imaging, altimetry, and radiometry. Radio links contribute information about intervening material and gravity fields. Other instruments measure electromagnetic fields and the properties of plasma, energetic particles, and dust particles. The probe is spin stabilized. It returns data via an S-band link to the orbiter. The probe's six instruments include sensors to determine atmospheric physical properties and composition. Radiometric and optical sensors will produce data on thermal balance and obtain images of Titan's atmosphere and surface. Doppler measurements between probe and orbiter will provide wind profiles. Surface sensors will measure impact acceleration, thermal and electrical properties, and, if the surface is liquid, density and refractive index. This design will enable Cassini to determine the composition; the physical, morphological, and geological nature; and the physical and chemical processes of the atmospheres, surfaces, and magnetosphere of the Saturnian system. This paper briefly describes the Cassini mission and spacecraft and, in somewhat more detail, the scientific instruments.

Jaffe, Leonard D.↗

Nuclear Science Symposium, 30th, and Symposium on Nuclear Power Systems, 15th, San Francisco, CA, October 19-21, 1983, Proceedings

The range of disciplines covered includes physics instrumentation, data acquisition, FASTBUS, radiation detectors, scintillators, photomultipliers and optical detectors, subnanosecond 2-D imaging, medical and health instrumentation, reactor instrumentation, and space instrumentation. Cerenkov detectors, the prevention and rate capability of breakdown processes in wire chambers, and an interactive parallel processor for data analysis are studied. Attention is also given to bismuth germanate's role in gamma-ray spectroscopy, and the construction of a broadband universal sampling head is described. Gamma-ray imaging with a rotating hexagonal uniform redundant array, and broadband X-ray astronomical spectrometry are considered.

Nakamura, M.↗

Complex Attosecond Waveform Synthesis at FEL FERMI

Free-electron lasers (FELs) can produce radiation in the short wavelength range extending from the extreme ultraviolet (XUV) to the X-rays with a few to a few tens of femtoseconds pulse duration. These facilities have enabled significant breakthroughs in the field of atomic, molecular, and optical physics, implementing different schemes based on two-color photoionization mechanisms. In this article, we present the generation of attosecond pulse trains (APTs) at the seeded FEL FERMI using the beating of multiple phase-locked harmonics. We demonstrate the complex attosecond waveform shaping of the generated APTs, exploiting the ability to manipulate independently the amplitudes and the phases of the harmonics. The described generalized attosecond waveform synthesis technique with an arbitrary number of phase-locked harmonics will allow the generation of sub-100 as pulses with programmable electric fields.

47 OTHER INSTRUMENTATION↗

Measurement techniques and instruments suitable for life-prediction testing of photovoltaic arrays

Array failure modes, relevant materials property changes, and primary degradation mechanisms are discussed as a prerequisite to identifying suitable measurement techniques and instruments. Candidate techniques and instruments are identified on the basis of extensive reviews of published and unpublished information. These methods are organized in six measurement categories - chemical, electrical, optical, thermal, mechanical, and other physicals. Using specified evaluation criteria, the most promising techniques and instruments for use in life prediction tests of arrays were selected.

Noel, G. T.↗

Characterization of carbonaceous aerosols during TRACER-CAT

Absorbing aerosols (AA) have an important impact on the global radiation budget and cloud properties. The composition and properties of AA can vary substantially throughout the atmosphere, depending on the particle source and the influence of chemical aging. Uncertainties associated with the radiative effects of AA remain substantial. A key contributor to this uncertainty is understanding the extent to which coatings in general, and water uptake especially, alters absorption by AA particles and how this depends on particle composition. We deployed new and existing experimental tools during the Tracking Aerosol Convection Interactions Experiment (TRACER) campaign in Houston, TX as part of the Carbonaceous Aerosols Thrust (CAT) to provide detailed characterization of aerosol optical, chemical, and physical properties. Our TRACER-CAT measurements complemented and expanded on the planned TRACER instrumentation, allowing for more detailed characterization of aerosol properties of relevance to cloud development (a core focus of TRACER), such as the composition of particles that can act as cloud condensation nuclei, than would otherwise be available. Our measurements have allowed for assessment of the relationship(s) between AA optical properties (with a focus on absorption) and the chemical and physical characteristics (including the mixing state of black carbon (BC) containing particles). These field observations occurred in collaboration with Los Alamos National Laboratory in summer 2022 during the TRACER intensive operating period. The instrumentation we co-deployed provided for measurement of (i) multi-wavelength dry aerosol absorption, scattering, and extinction, (ii) the size-dependent composition and abundance of sub-micron aerosol, differentiating between those particles that do and do not contain BC, (iii) BC-specific concentrations and size distributions, (iv) particle size, and (v) the first field measurements at an ARM site of the influence of RH on multi-wavelength absorption by ambient AA. We have leveraged the natural variability of the atmosphere and of aerosol sources in the Houston region to (i) specifically disentangle contributions to light absorption from BC, absorbing organic carbon (brown carbon), and coatings on BC, (ii) characterize the mixing state of BC and assess the factors that give rise to compositional differences between BC-containing and BC-free aerosol, and (iii) establish how water uptake influences absorption and how any such effect depends on particle composition and BC mixing state. Overall, our study contributed to the mission of the Atmospheric System Research program in multiple ways. Through the deployment of complementary, advanced instrumentation for characterization of a wide range of aerosol properties our work helped to maximize the scientific impact of the TRACER campaign. Our work also allowed for development of new insights into the relationship(s) between aerosol composition, hygroscopicity, and the mixing state of BC with aerosol optical properties. Through this, our work has provided knowledge that can improve understanding and model representation of aerosol processes as they affect the Earth’s radiation budget.

54 ENVIRONMENTAL SCIENCES↗

Recent Advances in Vertically Aligned Nanocomposites with Tunable Optical Anisotropy: Fundamentals and Beyond

Developing reliable and tunable metamaterials is fundamental to next-generation optical-based nanodevices and computing schemes. In this review, an overview of recent progress made with a unique group of ceramic-based functional nanocomposites, i.e., vertically aligned nanocomposites (VANs), is presented, with the focus on the tunable anisotropic optical properties. Using a self-assembling bottom-up deposition method, the as-grown VANs present great promise in terms of structural flexibility and property tunability. Such broad tunability of functionalities is achieved through VAN designs, material selection, growth control, and strain coupling. The as-grown multi-phase VAN films also present enormous advantages, including wafer scale integration, epitaxial quality, sharp atomic interface, as well as designable materials and geometries. This review also covers the research directions with practical device potentials, such as multiplex sensing, high-temperature plasmonics, magneto-optical switching, as well as photonic circuits.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Thermalization of the Kerr index of refraction in acetone and methanol using femtosecond pump-probe scattering spectroscopy

Femtosecond time-resolved pump-probe scattering is used to temporally investigate the index thermalization Δn(t) of the molecular motions associated with the Kerr nonlinear index n 2 . This is done using an intense 300 fs 1034 nm pump pulse and temporally probed by a 517 nm and supercontinuum pulse in acetone and methanol. The optically pumped molecular states change the index of refraction and through the processes of Raman and Rayleigh scattering are shown to engage in a 4-step energy relaxation process. Here, the pump first initiates the Kerr effect as well as populate resonant vibrational molecular motions, which act as a “mother” energy state. The electronic component of the Kerr effect is shown to couple with these vibrational modes through the process of Born-Oppenheimer coupling, which can be measured through the Raman scattering of the probe. The “mother” coupled state then decays into “daughter” anharmonic non-resonant states, which then further decay into “granddaughter” and thermal bath states. The population of these states alter the index of refraction in time, Δn(t), and can be measured through the changing in the probe beam’s Rayleigh scattering. This thermalization process takes ~5.5 ps in acetone and ~3.7 ps in methanol. The scattering signals from each Δn(t) thermalization stage in the localized region, (“mother”, to “daughter”, to “granddaughter”, to the bath states, to the ground state), are fitted to theoretical decay equations that show the rise and fall times of the energy decay routes.

47 OTHER INSTRUMENTATION↗

Sensitive neutron transverse polarization analysis using a 3 He spin filter

Here we report an experimental implementation for neutron transverse polarization analysis that is capable of detecting a small angular change ($\ll$10 –3 rad) in neutron spin orientation. This approach is demonstrated for monochromatic beams, and we show that it could be extended to polychromatic neutron beams. Our approach employs a 3 He spin filter inside a solenoid with an analyzing direction perpendicular to the incident neutron polarization direction. The method was tested with polarized neutron beams and a spin rotator placed inside a μ -metal shield just upstream of the analyzer. No cryogenic superconducting shields or additional neutron spin manipulations are needed. With a counting detector, we experimentally show that the angular resolution δ θ = 1 / ( P n A N ) rad is only determined by the counting statistics for the total counts N and the product of the neutron polarization P n and the analyzing power A . With a high-flux neutron beam, 10 –6 rad angular sensitivity is feasible within a day. This simple, classical-quantum-limited transverse polarization analysis scheme may reduce the overall complexity of experimental implementation for applications requiring sensitive neutron polarimetry and improve the precision in fundamental science studies and polarized neutron imaging.

47 OTHER INSTRUMENTATION↗

Design and expected performance of a variable-radii sinusoidal spiral x-ray spectrometer for the National Ignition Facility

A novel high-resolution x-ray spectrometer for point-like emission sources has been developed using a crystal shape having both a variable major and a variable minor radius of curvature. This variable-radii sinusoidal spiral spectrometer (VR-Spiral) allows three common spectrometer design goals to be achieved simultaneously: 1. reduction of aberrations and improved spectral (energy) resolution, 2. reduction of source size broadening, and 3. use of large crystals to improve total throughput. The VR-Spiral concept and its application to practical spectrometer design are described in detail. This concept is then used to design a spectrometer for an extreme extended x-ray absorption fine structure experiment at the National Ignition Facility looking at the Pb L 3 absorption edge at 13.0352 keV. The expected performance of this VR-Spiral spectrometer, both in terms of energy resolution and spatial resolution, is evaluated through the use of a newly developed raytracing tool, xicsrt. Finally, the expected performance of the VR-Spiral concept is compared to that of spectrometers based on conventional toroidal and variable-radii toroidal crystal geometries showing a greatly improved energy resolution.

47 OTHER INSTRUMENTATION↗

High efficiency radio frequency antennas for amplifier free quantum sensing applications

Radio frequency (RF) signals are frequently used in emerging quantum applications due to their spin state manipulation capability. Efficient coupling of RF signals into a particular quantum system requires the utilization of carefully designed and fabricated antennas. Nitrogen vacancy (NV) defects in diamond are commonly utilized platforms in quantum sensing experiments with the optically detected magnetic resonance (ODMR) method, where an RF antenna is an essential element. We report on the design and fabrication of high efficiency coplanar RF antennas for quantum sensing applications. Single and double ring coplanar RF antennas were designed with -37 dB experimental return loss at 2.87 GHz, the zero-field splitting frequency of the negatively charged NV defect in diamond. The efficiency of both antennas was demonstrated in magnetic field sensing experiments with NV color centers in diamond. In conclusion, an RF amplifier was not needed, and the 0 dB output of a standard RF signal generator was adequate to run the ODMR experiments due to the high efficiency of the RF antennas.

47 OTHER INSTRUMENTATION↗

Experimental study on the startup of the annular wick type heat pipe using fiber optical temperature measurement technique

This study used optical fiber-distributed temperature sensors to measure the internal and external temperature distributions of a water-cooled heat pipe. The sensor technology used in this study is fiber optical distributed temperature sensing, a distributed sensing technique based on the naturally occurring Rayleigh backscatter in optical fibers. This measurement technique provides maximum spatial resolution for static and semi-static applications. Using this sensor, the temperature distribution of the heat pipe's internal, external, vapor core, and the wick was measured with a spatial resolution of 0.65 mm, a sampling frequency of 40 Hz, and a temperature resolution of 0.1 °C. Through the measured temperature distribution database, the starting phenomenon, the effective length trend, and the limitation onset were observed. From the results, it is found that a high-temperature peak appears at the evaporator if a high initial power (75 W) is imposed on the heat pipe, even after the heat pipe approaches the normal operating status. The peak is not observed in a slower startup (30 W initial power then slowly increased to 75 W). It is also found that the temperature distributions and effective condenser length of the heat pipe highly depend on the cooling conditions. There are variations in the temperature according to the radial direction of the horizontal heat pipe due to gravity. In conclusion, lead and lag of the temperature evolution were observed at the onset of the operating limitations.

42 ENGINEERING↗