Search NASA⌕ Search

SEARCH · Search NASA

Results for “Physics, Optics and optical instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

A beamline for ultrafast extreme ultraviolet magneto-optical spectroscopy in reflection near the shot noise limit

High harmonic generation (HHG) makes it possible to measure spin and charge dynamics in materials on femtosecond to attosecond timescales. However, the extreme nonlinear nature of the high harmonic process means that intensity fluctuations can limit measurement sensitivity. Here we present a noise-canceled, tabletop high harmonic beamline for time-resolved reflection mode spectroscopy of magnetic materials. We use a reference spectrometer to independently normalize the intensity fluctuations of each harmonic order and eliminate long term drift, allowing us to make spectroscopic measurements near the shot noise limit. Here, these improvements allow us to significantly reduce the integration time required for high signal-to-noise (SNR) measurements of element-specific spin dynamics. Looking forward, improvements in the HHG flux, optical coatings, and grating design can further reduce the acquisition time for high SNR measurements by 1–2 orders of magnitude, enabling dramatically improved sensitivity to spin, charge, and phonon dynamics in magnetic materials.

47 OTHER INSTRUMENTATION↗

Detector thickness effects on nanosecond-gated imager response

Hybrid CMOS multi-frame imagers with exposure times down to ~2 ns have made significant impacts in high energy density physics and inertial confinement fusion research. The detector thickness is a key parameter in both detector quantum efficiency and temporal response. The Icarus hybrid CMOS imager has been fabricated with Si detector thicknesses of 8, 25, and 100 µm. The temporal response of imaging sensors with exposure time down to 2 ns has been examined and compared to directly measured photodiode current. The 100-μm thick variant displays extended features related to charge carrier collection and is more susceptible to field collapse. Here, we also demonstrate charge collection time effects on spatial response.

47 OTHER INSTRUMENTATION↗

Optimization of neutron chopper and optics for CENTAUR, the SANS/WANS diffractometer at the spallation neutron source second target station

Herein this report presents the physics design and optimization of the neutron chopper and optics systems for the CENTAUR instrument, a multifunctional small-angle and wide-angle neutron scattering diffractometer for the Spallation Neutron Source Second Target Station. This instrument will offer a wide range of capabilities, including small-angle neutron scattering with wide Q coverage (e.g., 0.001–20 Å –1 ), providing a tool to investigate structures from atomic to mesoscopic scales simultaneously. To efficiently transport desired neutrons from the compact high-brightness cold source, several innovative designs are utilized: a time-zero chopper with a straight guide system for short-wavelength neutrons, octagonal guides for higher flux, and a correlation chopper to reduce inelastic scattering. The optimization process considers factors such as useable time-integrated flux, instrument resolution, brilliance transfer, divergence, and acceptance diagram uniformity. The overall design prioritizes flexibility to accommodate diverse user requirements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and construction of a quantum matter synthesizer

The quantum matter synthesizer (QMS) is a new quantum simulation platform in which individual particles in a lattice can be resolved and re-arranged into arbitrary patterns. The ability to spatially manipulate ultracold atoms and control their tunneling and interactions at the single-particle level allows full control of a many-body quantum system. We present the design and characterization of the QMS, which integrates into a single ultra-stable apparatus a two-dimensional optical lattice, a moving optical tweezer array formed by a digital micromirror device, and site-resolved atomic imaging. We demonstrate excellent mechanical stability between the lattice and tweezer array with relative fluctuations below 10 nm, diffraction-limited imaging at a resolution of 655 nm, and high-speed real-time control of the tweezer array at a 2.52 kHz refresh rate, which will be adopted to realize fast rearrangement of atoms. The QMS also features new technologies and schemes, such as nanotextured anti-reflective windows and all-optical long-distance transport of atoms.

47 OTHER INSTRUMENTATION↗

Time Projection Chamber (TPC) detectors for nuclear astrophysics studies with gamma beams

Gamma-Beams at the HIS facility in the USA and anticipated at the ELI-NP facility, now constructed in Romania, present unique new opportunities to advance research in nuclear astrophysics; not the least of which is resolving open questions in oxygen formation during stellar helium burning via a precise measurement of the 12C() reaction. Time projection chamber (TPC) detectors operating with low pressure gas (as an active target) are ideally suited for such studies. We look over the progress of the current research program and plans for the future at the HIS facility with the optical readout TPC (O-TPC) and the development of an electronic readout TPC for the ELI-NP facility (ELITPC).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Non-linear enhancement of ultrafast X-ray diffraction through transient resonances

Diffraction-before-destruction imaging with ultrashort X-ray pulses can visualize non-equilibrium processes, such as chemical reactions, with sub-femtosecond precision in the native environment. Here, a nanospecimen diffracts a single X-ray flash before it disintegrates. The sample structure can be reconstructed from the coherent diffraction image (CDI). State-of-the-art X-ray snapshots lack high spatial resolution because of weak diffraction signal. Bleaching effects from photo-ionization significantly restrain image brightness scaling. We find that non-linear transient ion resonances can overcome this barrier if X-ray laser pulses are shorter than in most experiments. We compared snapshots from individual ≈ 100 nm Xe nanoparticles as a function of pulse duration and incoming X-ray fluence. Our experimental results and Monte Carlo simulations suggest that transient resonances can increase ionic scattering cross sections significantly beyond literature values. This provides a novel avenue towards substantial improvement of the spatial resolution in CDI in combination with sub-femtosecond temporal precision at the nanoscale.

47 OTHER INSTRUMENTATION↗

Dynamical quantum phase transitions in interacting atomic interferometers

Particle-wave duality has allowed physicists to establish atomic interferometers as celebrated complements to their optical counterparts in a broad range of quantum devices. In particular, interactions give rise to multiparticle correlations unavailable in linear interferometers. Here, we show that interactions lead to dynamical quantum phase transitions (DQPTs) between NOON states in an atomic interferometer. These transition points result from zeros of the Loschmidt echo, which approach the real axis of the complex time plane in the large-particle-number limit, and signify pair condensates, another type of exotic quantum states featured with prevailing two-body correlations. Such DQPTs thus provide us with a new angle to understand many-body states emergent from quantum nonequilibrium dynamics. Further, our work also suggests interacting atomic interferometers as a new tool for creating highly entangled states to beat the standard quantum limit.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reflectance of rhenium as a function of pressure in a diamond anvil cell

We have measured the reflectance of rhenium in the visible region to pressures up to 100 GPa in a diamond anvil cell (DAC). By photographing the reflecting surface, we visually show that there are challenges to obtaining accurate values in a DAC for several reasons, including cupping of the diamonds and roughening of the surface with the increase in pressure. We propose some useful procedures, such as careful alignment of the incident light and using thin gaskets to minimize cupping of the diamonds as well as measurement in the central region of the diamond culet. We also show that knowledge of the reflectance of rhenium can overcome the problem of absorption of light by diamonds when studying the reflectance of materials at high pressure in a DAC.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

New method for the determination of photoabsorption from transmittance measurements in the extreme ultraviolet

We have developed a new method for the determination of photoabsorption at extreme ultraviolet wavelengths longer than 20 nm, where reliable refractive index values are sparse or non-existent. Our method overcomes the obstacle of multiple reflections that occur inside thin films in this spectral range, which up until now has prevented the accurate determination of photoabsorption from transmittance measurements. We have derived a mathematical expression that is independent of internal reflection amplitudes, while taking advantage of the transmittance oscillations stemming from such reflections. The method is validated on measurements of aluminum thin films. This advance will enable accurate refractive index values for many important materials for optical instrumentation, thus facilitating high-priority research on topics including coherent light sources, planetary and solar physics, and semiconductor manufacturing.

74 ATOMIC AND MOLECULAR PHYSICS↗

Photochemistry sample sticks for inelastic neutron scattering

Every material experiences atomic and molecular motions that are generally termed vibrations in gases and liquids or phonons in solid state materials. Optical spectroscopy techniques, such as Raman, infrared absorption spectroscopy, or inelastic neutron scattering (INS), can be used to measure the vibrational/phonon spectrum of ground state materials properties. A variety of optical pump probe spectroscopies enable the measurement of excited states or elucidate photochemical reaction pathways and kinetics. So far, it has not been possible to study photoactive materials or processes in situ using INS due to the mismatch between neutron and photon penetration depths, differences between the flux density of photons and neutrons, cryogenic temperatures for INS measurements, vacuum conditions, and a lack of optical access to the sample space. These experimental hurdles have resulted in very limited photochemistry studies using INS. Here we report on the design of two different photochemistry sample sticks that overcome these experimental hurdles to enable in situ photochemical studies using INS, specifically at the VISION instrument at Oak Ridge National Laboratory. We demonstrate the use of these new measurement capabilities through (1) the in situ photodimerization of anthracene and (2) the in situ photopolymerization of a 405 nm photoresin using 405 nm excitation as simple test cases. Furthermore, these new measurement apparatus broaden the science enabled by INS to include photoactive materials, optically excited states, and photoinitiated reactions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

MagAO Observations of the Binary Microlens OGLE-2014-BLG-1050 Prefer the Higher-mass Solution

We report adaptive optics (AO) follow-up imaging of OGLE-2014-BLG-1050, which is the second binary microlensing event with space-based parallax measurements. The degeneracy in microlens parallax π {sub E} led to two sets of solutions, either a ∼ (0.9, 0.35)M {sub ⊙} binary at ∼3.5 kpc or a ∼(0.2, 0.07)M {sub ⊙} binary at ∼1.1 kpc. We measure the flux blended with the microlensed source by conducting Magellan AO observations, and find that the blending is consistent with the predicted lens flux from the higher-mass solution. From the combination of the AO flux measurement together with previous lensing constraints, it is estimated that the lens system consists of a 1.05{sub −0.07}{sup +0.08} M{sub ⊙} primary and a 0.38{sub −0.06}{sup +0.07}M{sub ⊙} secondary at 3.43{sub −0.21}{sup +0.19} kpc.

47 OTHER INSTRUMENTATION↗

Intercomparison of airborne and surface-based measurements during the CLARIFY, ORACLES and LASIC field experiments

Data are presented from intercomparisons between two research aircraft, the FAAM BAe-146 and the NASA Lockheed P3, and between the BAe-146 and the surface-based DOE (Department of Energy) ARM (Atmospheric Radiation Monitoring) Mobile Facility at Ascension Island (8 S, 14.5W, a remote island in the mid-Atlantic). These took place from 17 August to 5 September 2017, during the African biomass burning season. The primary motivation was to give confidence in the use of data from multiple platforms with which to evaluate numerical climate models. The three platforms were involved in the CLouds-Aerosol-Radiation Interaction and Forcing for Year 2017 (CLARIFY-2017), ObseRvations of Aerosols above CLouds and their intEractionS (ORACLES), and Layered Atlantic Smoke and Interactions with Clouds (LASIC) field experiments. Comparisons from flight segments on six days where the BAe-146 flew alongside the ARM facility on Ascension Island are presented, along with comparisons from wing-tip to wing-tip flight of the P3 and BAe-146 on 18 th August 2017. The intercomparison flight sampled a relatively clean atmosphere overlying a moderately polluted boundary layer, while the 6 fly-bys of the ARM site sampled both clean and polluted conditions 2–4 km upwind. We compare and validate characterisations of aerosol physical, chemical, and optical properties, atmospheric radiation, and cloud microphysics between platforms. We assess the performance of measurement instrumentation in the field, under conditions where sampling conditions are not tightly controlled as in laboratory measurements where calibrations are performed. Solar radiation measurements compared well between airborne platforms. Optical absorption coefficient measurements compared well across all three platforms, even though absolute magnitudes were often low (< 10 Mm -1 ) and close to the sensitivity limits of measurement instrumentation thereby confounding assessments of the comparability of absorption Ångström exponent characterisations. Aerosol absorption measurements from airborne platforms were more comparable than aircraft-to-ground observations. Scattering coefficient observations compared well between airborne platforms, but agreement with ground-based measurements was worse, potentially caused by small differences in sampling conditions or actual aerosol population differences. Chemical composition measurements followed a similar pattern, with better comparisons between the airborne platforms. Thermodynamics, aerosol, and cloud microphysical properties generally compared well.

54 ENVIRONMENTAL SCIENCES↗

Light-powered end-to-end neutron detection and imaging with an edge-deployed optical AI chip

Neutron detection is widely used in many applications including nuclear physics, nuclear energy, nuclear technologies and nuclear safeguards. Developing an end-to-end neutron detection and imaging workflow paves way towards fully automated processes for many applications. We implemented an automated workflow for neutron detection experiments which use a solid state image sensor to capture neutron hits as a digital image. We deploy the workflow to an edge-based optical neural network (ONN) to increase the radiation-hardness and lifetime of neutron detection instruments. We present a two-stage neural network framework for detection of neutrons at sub-pixel resolution. The first stage uses a region proposal network to efficiently detect and extract neutron hits from the input camera image. The second stage feeds the extracted hits into a fully connected neural network to predict the sub-pixel hit position. The performance of the two-stage framework is evaluated using the edge-based ONN. The results show that we can achieve above 96% neutron detection accuracy as well as sub-pixel and sub-micron position resolution, while enjoying the advantages of the ONN hardware including radiation-hardness, low energy consumption and high computing speed for integrated edge camera and hardware deployment, when compared with electronic counterparts.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-redshift quasars along the main sequence

The 4D Eigenvector 1 empirical formalism (4DE1) and its main sequence (MS) for quasars has emerged as a powerful tool for organising the diversity among quasar populations, as several key observational measures and physical parameters are systematically changing along it. Trends revealed by 4DE1 are very well established to explain all the diverse characteristics seen in low-redshift quasar samples. Nevertheless, the situation is far less clear when dealing with high-luminosity and high-redshift sources. Here, we aim to evaluate the behaviour of our sample of 22 quasars at high redshift (2.2 ≤ z ≤ 3.7) and high luminosity (47.39 ≤ L bol ≤ 48.36) in the context of the 4DE1. Our approach involves studying quasar physics through a spectroscopic exploration of UV and optical emission line diagnostics. We used new observations from the ISAAC instrument at ESO-VLT and primarily from the SDSS to cover the optical and the UV rest-frames, respectively. The emission lines were characterised both via a quantitative parametrisation of the line profiles and a decomposition of the emission line profiles using multicomponent fitting routines. We provide spectrophotometric properties and line profile measurements for Hβ+[O III]λλ4959,5007, as well as Si IVλ1397+O IV]λ1402, C IVλ1549+He IIλ1640, and the 1900 Å blend (including Al IIIλ1860, Si III]λ1892, and C III]λ1909). For six out of the 22 objects, a significantly blueshifted component on the Hβ profile is present. In 14 out of 22 cases, an Hβ outflowing component associated with [O III] is detected. The majority of [O III]λλ4959,5007 emission line profiles show blueshifted velocities higher than 250 km s -1 . We find extremely broad [O III]λλ4959,5007 emission that is comparable to the width of Hβ broad profile in some highly accreting quasars. The [O III]λλ4959,5007 and C IVλ1549 blueshifts show very high amplitudes and a high degree of correlation. The line widths and shifts are correlated for both [O III]λλ4959,5007 and C IVλ1549, suggesting that emission from outflowing gas is providing a substantial broadening effect to both lines. Otherwise, the links between C IVλ1549 centroid velocity at half intensity (c(1/2)), Eddington ratio (L/L Edd ), and bolometric luminosity are found to be in agreement with previous studies of high-luminosity quasars. Our analysis suggests that the behaviour of quasars of very high luminosity all along the main sequence is strongly affected by powerful outflows involving a broad range of spatial scales. The main sequence correlations remain valid at high redshift and high luminosity even if a systematic increase in line width is observed. Scaling laws based on UV Al IIIλ1860 and Hβ emission lines are equally reliable estimators of M BH .

79 ASTRONOMY AND ASTROPHYSICS↗